Scientific Program
SESSION A.0 : OPENING SESSION
Monday June 25, 2007 - 9:00 - 10:30 - Room : A
top of page
I.0
Opening Lecture by M. J-C Boudenot, Thalès Research & Technology
SESSION A.1 : HV / EHV CABLE SYSTEM - DEVELOPMENTS
Monday June 25, 2007 - 11:00 - 12:30 - Room : A
top of page
Chairman :
F. RÜTER - ABB Power Technologies(Sweden)
Rapporteur :
Y. MAUGAIN - RTE DDOP (France)
A1 - Session Report
A.1.1
Development of 400 kV class XLPE insulated power cable and accessories
KUWAKI A., HAYASHI K., EXSYM Corp., Kumagara, Saitama, Japan
KATO K., EXSYM Corp., Mito, Aichi, Japan
IMAI N., EXSYM Corp., Sagamihara, Kanagawa, Japan
A.1.2
400 kV XLPE insulated cable systems with dry plug-in outdoor terminations
KAUMANNS J., SCHRÖDER G., LEHNHÄEUSER J., STROOT V., WEINLEIN A., Südkabel, Mannheim, Germany
A.1.3
Development of one piece type joint (self pressurized joint) for 400 kV XLPE cables
FUDAMOTO K., WATANABE Y., , KISHI K., UOZUMI T., TERAYAMA A., J-Power Systems Corp., Osaka, Japan
A.1.4
French experience in aluminium laminated screens
LESUR F., EDF R&D, Moret-sur-Loing, France
ARGAUT P., SILEC CABLE, Montereau, France
BENARD L., PRYSMIAN, Paron, France
MIREBEAU P., NEXANS France, Calais, France
A.1.5
Development of the high voltage extruded cables: Italian experience
ZACCONE E., PRYSMIAN Cables & Systems, Milan, Italy
FARA A., ENEL, Rome, Italy
A.1.6
400 kV 2500mm² XLPE cable system prequalification and type test for Middle East environment
MATALLANA J., GAHUNGU F., DUVIVIER M., DUBOIS D., MIREBEAU P., NEXANS France, Calais, France
SESSION B.1 : LV / MV SYSTEMS (1)
Monday June 25, 2007 - 11:00 - 12:30 - Room : B
top of page
Chairman :
S. SALDIVAR - Conductores Monterrey (Mexico)
Rapporteur :
A. DOULET - ERD (France)
B1 - Session Report
I.2
Invited paper: nano technologies applied to cables.,
B.1.1
Investigation of the aging characteristics of CST termination made of silicone rubber at contamination area
NAKAMURA T., KOZASA Y., SATO A., KONDO T., Chubu Electric Power Co., Nagoya, Japan
OHTSUBO M., Sumitomo 3M, Sagamihara-Shi, Kanagawa, Japan
B.1.2
Evaluation of a replacement strategies of a medium voltage cable joint based on statistical failure analysis
JONGEN R.A., MORSHUIS P. H. F., SMIT J. J., Delft University of Technology, Netherlands
JANSSEN A.L.J., Nuon Assetmanagement, Arnhem, Netherlands
GULSKI E., Ksandr, Delft, Netherlands
C.5.1.8
Surge propagation and protection of underground distribution cables
LEE J-b, KIM J-y, PARK C-b, JUNG Y-a, Korea Elecctric Power Institute (KEPRI), South Korea
B.1.4
Emergency conditions applied to Triplex medium-voltage XLPE cables having flat strap neutrals
PÉLISSOU S., IREQ, Varennes, Canada
CÔTÉ J., ST-ANTOINE S., DALLAIRE J., Réseau de Distribution, Hydro-Québec, Montréal, Canada
B.1.5
New specification to check cable sheath resistance to termites
BRUMENT Y., LESUR F., EDF R&D, Moret-sur-Loing, France
SESSION A.2 : HV / EHV LARGE PROJECTS
Monday June 25, 2007 - 14:30 - 16:00 - Room : A
top of page
Chairman :
J. BECKER - BECKER Consult (Belgium)
Rapporteur :
P. ARGAUT - SILEC CABLE (France)
A2 - Session Report
A.2.1
Large projects of EHV underground cable systems
BJORLOW-LARSEN K., NEXANS
ZACCONE E., PRYSMIAN Cables & Systems, Milan, Italy
SHELL F., Brugg Kabel
WACHT W., NKT Cables, Germany
ARGAUT P., SAGEM
A.2.2
The St. John´s Wood - Elstree experience: testing a 20 km long 400 kV XLPE-insulated cable system after installation
SCHRÖDER G., Südkabel, Mannheim, Germany
PLATH R., IPH, Berlin, Germany
SUTTON S., National Grid, Warwick, UK
A.2.3
New 345 kV underground extruded cable system project in Connecticut
ARGAUT P., LUTON MH., SILEC CABLE, Montereau, France
TIRINZONI P., Northeast Utilities , Hartford, USA
LANNING J., New River Electrical Corp , Cloverdale , USA
MOSIER R., Power Delivery Consultants, Ballston Lake, NY, USA
A.2.4
87/150 (170) kV Koksijde-Slijkens link
LEROY Y., LIEMANS D., NEXANS Benelux, Charleroi, Belgium
GAHUNGU F., NEXANS France, Calais, France
A.2.5
Undergrounding and reorganization of the electrical system of the city of Madrid
ORELLA SÁENZ J., CABERO ALONSO R., Iberdrola Ingeniería y Construcción, Erandio, Spain
A.2.6
HV power cables installed in multi-purpose tunnels, a challengeable option!
DE WILD F. H., BOONE W., KEMA, Arnhem, Netherlands
SESSION B.2 : LV / MV SYSTEMS (2)
Monday June 25, 2007 - 14:30 - 16:00 - Room : B
top of page
Chairman :
J. ROVIRA - Grupo General Cables Sistemas (Spain)
Rapporteur :
S. TOGNALI - PRYSMIAN C&S (France)
B2 - Session Report
B.2.1
New high performance, environmentally friendly MV power cable insulations
EASTER M., General Cable, Indianapolis, USA
MASARELLA E., General Cable, Manlleu, Spain
ASPIAZU L., MAIZ G., Iberdrola, Bilbao, Spain
B.2.2
New concept in cables and accessories for low voltage underground distribution in Spain
MAÍZ G., AZPIAZU L., Iberdrola, Bilbao, Spain
RIERA J., Niled, Manresa, Spain
ROVIRA J., General Cable, Barcelona, Spain
B.2.3
Corrosion kinetics of LV cable galvanised steel screen
BRUMENT Y., EDF R&D, Moret-sur-Loing, France
GIFFARD P., LODEIRO M., BORDESELLE G., Draka Paricable France, France
BEUCHER E., CRITT Haute Normandie, France
B.2.4
A new pulling-cable software at Hydro-Quebec
TARNOWSKI J., IORDANESCU M., BERGERON F., RATEL G., VALIQUETTE D., IREQ, Varennes, Canada
B.2.5
Service experiences for MV cable network – optimistic or pessimistic state of the art?
RAKOWSKA A., Poznan University of Technology, Poznan, Poland
B.2.6
Harmonising MV cables: Results of the European project EUROMVCABLE
LESUR F., BRUMENT Y., EDF R&D, Moret-sur-Loing, France
SESSION A.3 : CABLES FOR THE FUTURE
Monday June 25, 2007 - 16:30 - 18:15 - Room : A
top of page
Chairman :
J-L PARPAL - Hydro Quebec (Canada)
Rapporteur :
Ch. AUCOURT - RTE (France)
A3 - Session Report
A.3.1
Superconducting cables - status and applications
SAUGRAIN JM., NEXANS France, Clichy, France
SCHMIDT F., NEXANS GmbH&Co.KG, Hannover, Germany
MIREBEAU P., NEXANS France, Calais, France
A.3.2
Installation and commissioning of TRIAX HTS cable
LINDSAY D. T., Southwire Company, Carrollton, USA
A.3.3
Installing a long-distance HTS cable
GESCHIERE A., PIGA E., Nuon, Duiven, Netherlands
WILLÉN D., NKT Cables, Brondby, Denmark
BARENDREGT P., NKT Cables, Köln, Germany
LYNCH N., Praxair, Danbury, USA
A.3.4
Development and demonstration of a long length transmission voltage cold dielectric superconducting cable to operate in the Long Island power authority grid
SCHMIDT F., NEXANS GmbH&Co.KG, Hannover, Germany
MAGUIRE J., American Superconductor, Westborough, USA
BRATT S., AIR LIQUIDE DTA, Sassenage, France
WELSH T., Long Island Power Authority, Hicksville, USA
LALLOUET N., NEXANS France, Calais, France
A.3.5
Potential of multilayer coating for improvement of the dielectric withstand in gas insulated cable
HAIROUR M., BESSEDE JL., AREVA T&D, Villeurbanne, France
MIKES E., AREVA T&D AG, Oberentfelden, Switzerland
A.3.6
Gas insulated transmission lines – under-ground bulk power transmission achieving a maximum of operational safety and reliability
KUNZE D., PÖHLER S., ALTER J., SIEMENS AG, Erlangen, Germany
BINDER E., TÜRK J., VERBUND Austrian Hydro Power, Salzburg, Austria
SESSION B.3 : INDUSTRIAL & SPECIAL CABLES
Monday June 25, 2007 - 16:30 - 18:00 - Room : B
top of page
Chairman :
F. KRÄHENBÜHL - NEXANS (Switzerland)
Rapporteur :
J-C. TOURAINE - PRYSMIAN C&S (France)
B3 - Session Report
B.3.1
Irradiation technologies and compounds for cables cross-linking – developments for flat and heat-trace cables<
ROUIF S., IONISOS, Dagneux, France
B.3.2
Electron beam curing of EVM and HNBR filled cable sheath compounds
LA ROSA M., WRANA C., LANXESS Deutschland, Leverkusen, Germany
B.3.3
Utilisation of ceramizing materials in fire resisting cables and accessories
WEIDER B., NEXANS Schweiz AG , Breitenbach, Switzerland
B.3.4
Ceramifying insulation materials for fire safety cables
ALEXANDER G., BARBER K., Olex Australia, Tottenham, Australia
B.3.5
Choices of flame retardant materials for cables with improved fire behaviour
DUPHIL D., POISSON B., ARGAUT P., SILEC CABLE, Montereau, France
BARBETA J., PASCUAL M.C., MARTINEZ J., General Cable, Manlleu, Spain
B.3.6
Use of nanofillers in high performance of MV cables under fire conditions.
CALVERAS D., GRABOLOSA J., General Cable, Manlleu, Spain
CANEROT I., SILEC CABLE, Montereau, France
B.3.7
Polymeric armor design of an improved protection to mechanical stresses and fluids for Oil and Gas Pretrochem (OGP) applications
CINQUEMANI P., PRYSMIAN Cables & Systems, USA
DE RAI L., FRIGERIO M., Milan, Italy
VEGGETTI P., PRYSMIAN Cables & Systems, Finland
SESSION A.4 : DIAGNOSTICS (1)
Tuesday June 26, 2007 - 9:00 - 10:30 - Room : A
top of page
Chairman :
A. RAKOWSKA - Poznan Univ. Of Technology (Poland)
Rapporteur :
P-M. DEJEAN - PRYSMIAN - PLURIDIS (France)
A4 - Session Report
A.4.1
Permanent on-line monitoring of MV power cables based on partial discharge detection and localisation - an update
STEENNIS F., VAN DER WIELEN P., KAPTEIN B., KEMA-TDT, Arnhem, Netherlands
A.4.2
On-site VHF partial discharge detection on power cable accessories
MEIJER S., AGORIS P. D., SMIT J. J., Delft University of Technology, Netherlands
SEITZ P. P., Seitz Instruments AG, Niederrohrdorf, Switzerland
HERMANS T. J.W.H., LAMBALLAIS L., PRYSMIAN C&S, Delft, Netherlands
A.4.3
Continuous on-line monitoring of PDS in HV cables
ZHANG H., PHUNG B/T., LIU Z., BLACKBURN T.R., University of New South Wales, Sydney, Australia
A.4.4
Partial discharge detection in power cables: practical limits as a function of cable length
CAVALLINI A., MONTANARI G. C., University of Bologna, Italy
CHANDRASEKAR S., Sona College of Technology, Tamilnadu, India
A.4.6
New approach for high voltage cable on-site testing
RETHMEIER K., MOHAUPT P., BAUR Pruef- und Messtechnik, Sulz, Austria
BERGMANN V., SEIFERT S., KALKNER W., Technische Universitaet Berlin, Germany
SESSION B.4 : HV / EHV CABLES - UPGRADING
Tuesday June 26, 2007 - 9:00 - 10:30 - Room : B
top of page
Chairman :
S. SAKUMA - VISCAS (Japan)
Rapporteur :
P. MIREBEAU - NEXANS FRANCE (France)
B4 - Session Report
B.4.1
Health index, a tool for asset management
DORISON E., LESUR F., MEURICE D., EDF R&D, Moret-sur-Loing, France
B.4.2
Evaluation of the condition and the performance of underground high voltage fluid filled links at Hydro-Québec
ROYER C., AWAD R., Hydro-Québec, Montreal, Canada
B.4.3
Upgrading and uprating of underground existing systems
LESUR F., EDF R&D, Moret-sur-Loing, France
B.4.4
Renewal works of underground transmission system in KEPCO
KAYA T., FUJIWARA E., MATSUMURA M., Power System Engineering, Osaka, Japan
B.4.5
Re-evaluation of 150 kV cable capacity
VAN HOUWELINGEN D., ENECO-Netbeheer, Rotterdam, Netherlands
B.4.6
Modern cable systems in steel pipes - new designed XLPE-insulated cables substituting paper-insulated pipe-type cables
AUE V., ROSEBROCK W., NEXANS GmbH&Co.KG, Hannover, Germany
B.4.7
Increased voltage for the HVDC light product range – a complete solution
JEROENSE M., BERGKVIST M., GUSTAFSSON A., ABB Power Systems, Karlskrona, Sweden
RAPP H., SÖRQVIST T., SVAHN J., ABB Power Products, Alingsås, Sweden
SESSION A.5 : DIAGNOSTICS (2)
Tuesday June 26, 2007 - 11:00 - 12:30 - Room : A
top of page
Chairman :
W. BOONE - KEMA Nederland BV (Netherlands)
Rapporteur :
A. DENAT - CNRS - LEMD (France)
A5 - Session Report
A.5.1
US experience on condition assessment of various types of taped cable systems by dissolved gas analysis based on a novel sampling and analysis technique
SINGH N., SINGH S. K., REYES R. R., MOREL O. E., Detroit Edison Company, Detroit, USA
ZENGER W., Pacific Gas & Electric, California, USA
A.5.2
Remarkable tan delta suppression of oil filled cable insulation with extremely degraded tan delta oil
TAKAHASHI T., NAKAJIMA T., VISCAS Corporation, Ichihara, Japan
NAKADE M., IDE K., Tokyo Electric Power Company, Yokohama, Japan
A.5.4
Diagnostic for paper cable condition assesment
ESPILIT T., ZORZI F., REGAUDIE V., GAUDIN C., EDF R&D, Moret-sur-Loing, France
TAMBRUN R., EDF DRE, Paris, France
A.5.5
Application of optical fiber current sensors to underground cables
NASUKAWA S., KONDO R., YAMAGUCHI T., Tokyo Electric Power CO., Tokyo, Japan
AMANO K., FUJIKURA Ltd, Tokyo, Japan
YAMADA T., Takaoka Electric Mfg. Co. , Tokyo, Japan
A.5.6
Thermal transient analysis of underground cables
DESMET J., PUTMAN D., VANALME G., Hogeschool West-Vlaanderen, Kortrijk, Belgium
BELMANS R., K.U.Leuven, Belgium
CLOET E., ELIA, Brussel, Belgium
SESSION C.5.1 : CABLE SYSTEMS
Tuesday June 26, 2007 - 11:00 - 12:30 - Room : C-Posters Session
top of page
Chairman :
A. VALDENEGRO- Univ. de Chile (Chile)
Rapporteur :
P. GIFFARD - DRAKA PARICABLE (France)
C.5.1 - Session Report
C.5.1.1
High Performance MV Cable Semi Conducting Shields
EASTER M., General Cable, Indianapolis, USA
CANEROT I., SILEC CABLE, Montereau, France
C.5.1.2
Compounding of semiconductives for high voltage cables
RICHARDSON C. G., Buss AG, Pratteln, Switzerland
C.5.1.3
Stabilizer concepts for Silane crosslinked polyethylene cable applications
HERBST H., CIBA Specialty Chemicals, Basel, Switzerland
FAGOURI C., CIBA Specialty Chemicals, Tarrytown, USA
C.5.1.4
Performance of modern cables in Central Europe
WALD D., BOREALIS Polymers NV, Mechelen, Belgium
SMEDBERG A., BOREALIS AB, Stenungsund, Sweden
C.5.1.5
Long-life XLPE insulated power cables
ORTON H., OCEI, Vancouver, BC, Canada
HARTLEIN R., HAMPTON R.N., Georgia Inst., ECE-NEETRAC, Atlanta, USA
RAMACHANDRAN R., The Dow Chemical Company, Somerset, USA
C.5.1.6
Development on recycling technology of XLPE
SEKIGUCHI Y., OHKAWA N., NOJO H., HASHIMOTO S., J-Power Systems Corp., Tokyo, Japan
C.5.1.7
Innovative bolted connector for LV and MV with stepless shear bolts
LAURENT H., PFISTERER, Illzach France
GROSS H., PFISTERER AG, Winterbach, Germany
C.5.1.8
Surge propagation and protection of underground distribution cables
LEE J.b., KIM J.Y., KIM B.S., PARK C.B., JUNG Y.H., KEPCO, Daejeon, South Korea
C.5.1.9
Advances in chemical rejuvenation: extending MV cable life 40 years
BERTINI G. J., VINCENT G. A., Novinium Inc., Kent, USA
C.5.1.10
Dielectric system for submarine electro hydraulic umbilical up to 35 kV
TEIXEIRA jr M. D., MDR Consultoria, Rio de Janeiro, Brazil
ABIB L., Marine Production Systems do Brasil, Rio de Janeiro, Brazil
C.5.1.11
A development of underground distribution cable for water-blocking and reducing protrusions
LEE J.b., KIM J.Y., KIM B.S., SONG I., KEPCO, Daejeon, South Korea
C.5.1.111
European Work on LV ABC Accessories Standard
PORCHERAY G., Tyco Electronics SIMEL, France
C.5.1.12
Development of Pre-Molded Joint for 230 kV XLPE Power Cable
KIM H. J., KIM H. J., KIM S.Y., SONG J. H., Taihan Electric Wire, Seoul, South Korea
C.5.1.13
Transition joints
COURSET L., RTE CNER, Paris France
HONDAA P., EDF R&D, Moret-sur-Loing, France
C.5.1.14
Compact various transition joints for up to 154 kV power cable
YOKOYAMA S., TORAI Y., VISCAS Corporation, Tokyo, Japan
KANEKO S., VISCAS Corporation, Hirastuka, Japan
NIINOBE H., VISCAS Corporation, Ichihara, Japan
C.5.1.15
Upgrading quality of 275 kV Y - branch pre-fabricated transition joint
NAKANISHI T., J-Power Systems Corp., Osaka, Japan
C.5.1.16
Development of outdoor-sealing-end of prefabricated-composite-insulator for 66/7 kV XLPE cable
IWASAKI K., TANAKA A., TOYA A., Tokyo Electric Power CO., Tokyo, Japan
SATOU H., EXSYM Corp., Sagamihara, Kanagawa, Japan
ADACHI K., SEMA N., SWCC SHOWA Cable System, Kanagawa, Japan
C.5.1.17
Development of dry type out-door termination for 66 to 110 kV XLPE cable
OONO K., VISCAS Corporation, Ichihara, Japan
KANEKO S., TAKAOKA I., VISCAS Corporation, Hiratsuka, Japan
SESSION C.5.2 : CABLE INSTALLATION & RATING
Tuesday June 26, 2007 - 11:00 - 12:30 - Room : C-Posters Session
top of page
Chairman :
H. ORTON - ORTON Consulting ING (Canada)
Rapporteur :
A. CHAUVANCY - RTE CNER (France)
C.5.2 - Session Report
C.5.2.1
Modern fem-calculation tools – an ampacity calculation method for XLPE cables installed in ductbanks
KARLSTRAND J., HENNING G., ABB Power Systems, Karlskrona, Sweden
C.5.2.2
Application results of real-time ampacity estimation system and intelligent power cable system.
NAM S.H., LEE J.M., KIM C.S., KIM K.Y., LEE S.K., LS Cable, Anyang-si, South Korea
KIM H.L., KIM Y.S., LIM H.E., KEPCO, Seoul, South Korea
C.5.2.3
An adaptive monitor program for dynamic thermal rating of power cables
BRAKELMANN H., HIRSCH H., RÖHRICH A., SCHEIFFARTH H., STAMMEN J., University of Duisburg-Essen, Germany
C.5.2.4
HV cables operating in a dynamic rating regime, a beneficial option!
DE WILD F. H., BOONE W., KEMA, Arnhem, Netherlands
C.5.2.5
Development on the mortar material for cable systems in a directional drilling
NISHIYAMA Y., KOBAYASHI S., ISHIZONE T., ASHIZAWA Y., Chubu Electric Power Co., Nagoya, Japan
C.5.2.6
Sharing pipelines, tunnels, conduits, multipurpose structures, and rights of way among power cables, optical cables, gaslines, sewers, heating ducts, hot water pipes, and potable waterlines
JEYAPALAN J. K., Camp Dresser & McKee, Wethersfield, USA
C.5.2.7
Fire prevention method for 275 kV oil-filled cable joint in TEPCO
NASUKAWA S., TOYA A., Tokyo Electric Power CO., Tokyo, Japan
C.5.2.8
Development and its efficacy of sheath current reduction device on underground power cable systems
KANG J.W., YOON H.H., KWAK B.M., KEPCO, Daejeon, South Korea
C.5.2.9
Multiconductor cell analysis of power cable steady state
BENATO R., University of Padova, Italy
SESSION A.6 : HV / EHV CABLES - OPERATING CONSIDERATIONS
Tuesday June 26, 2007 - 14:30 - 16:00 - Room : A
top of page
Chairman :
A. GUSTAFSSON - ABB Power Systems (Sweden)
Rapporteur :
G. ROINEL - RTE CNER (France)
A6 - Session Report
I.2
Invited paper : Cigré Study Committee B1 (insulated Cables), by Fredrik RUTER, Chairman of SC B1
A.6.1
Facts for optimum utilisation of cable networks in power transmission
GRÜNBAUM R., ABB Power Technologies AB, Vasteras, Sweden
KARLSTRAND J., ABB Power Systems, Karlskrona, Sweden
A.6.2
Outsourcing preventive maintenance on underground power transmission cables
ALSHIBANI S., Ministry of Energy, Yarmouk, Kuwait
A.6.3
Failure prediction in 50 kV mass-insulated power cable systems
JONGEN R.A., MORSHUIS P. H. F., SMIT J. J., Delft University of Technology, Netherlands
JANSSEN A.L.J., Nuon Assetmanagement, Arnhem, Netherlands
GULSKI E., Ksandr, Delft, Netherlands
A.6.4
Fire hazard of MV / HV cables installed in tunnels
PHILIPPCZYK C., NKT Cables, Köln, Germany
VENO-POULSEN K., NKT Cables A/S, Asneas, Denmark
JOURNEAUX T., GRACIAS D., PRYSMIAN Cables & Systems, Eastleigh, UK
LOYENS W., BOREALIS AB, Stenungsund, Sweden
ROBINSON J., BOREALIS Polymers NV, Mechelen, Belgium
A.6.5
A dynamic rating system for a hybrid 150 kV transmission system
DE WILD F. H., KEMA, Arnhem, Netherlands
SMIT J. C., Nuon Tecno, Alkmaar, Netherlands
TREKOP R., Continuon netbeheer, Arnhem, Netherlands
SESSION B.6 : AGEING & DIAGNOSTICS
Tuesday June 26, 2007 - 14:30 - 16:00 - Room : B
top of page
Chairman :
P. LLOVERA - Inst. de Technologia Electrica (Spain)
Rapporteur :
E. DORISON - EDF R&D (France)
B6 - Session Report
B.6.2
Nuclear cables : lifetime simulation
MONCHY-LEROY C., EDF R&D, Moret-sur-Loing, France
THÉROND P., EDF SEPTEN, Villeurbanne, France
B.6.3
Time domain spectroscopy (TDS) as a diagnostic tool for MV XLPE underground lines
DRAPEAU JF., JEAN D., PARPAL JL., POTVIN C., LALANCETTE D., BERNIER S., L'ÉCUYER R., IREQ, Varennes, Canada
C.7.1.15
A Molecular approach to the electrical aging of XLPE cables
CRINE J.P., Technology Consultant, Canada
(also with Ecole Polytechnique de Montreal, Canada)
B.6.5
Development of an innovative residual-charge measurement technique for water-tree deteriorated XLPE cable
KON H., TANAKA H., VISCAS Corporation, Ichihara, Japan
TSUKAMOTO T., SATO H., ONUKI K., Tokyo Electric Power CO., Tokyo, Japan
B.6.6
Validating “diagnostic tests” for cables in service
PERKEL J., HAMPTON R.N., BEGOVIC M., HARTLEIN R., Georgia Inst., ECE-NEETRAC, Atlanta, USA
PERKEL J., HAMPTON R.N., BEGOVIC M., HARTLEIN R., Georgia Inst., ECE-NEETRAC, Atlanta, USA
SESSION A.7 : TESTING (1)
Tuesday June 26, 2007 - 16:30 - 18:00 - Room : A
top of page
Chairman :
E. STEENNIS - KEMA (Netherland)
Rapporteur :
J-C. VANNIER - SUPELEC (France)
A7 - Session Report
A.7.1
Sensitivity assessment for partial discharge measurements on solid dielectric transmission cables
FENGER M., SEDDING H., Kinectrics Inc., Toronto, Canada
A.7.2
On-line location of partial discharges in an electrical accessory of an underground power distribution network
CANTIN B., LÉONARD F., IREQ, Varennes, Canada
FOURNIER D., Hydro-Québec, Montreal, Canada
A.7.3
UHF-PD-monitoring and on-site-commissioning-test of 400 kV XLPE-insulated cable circuits at Jebel Ali / Dubai
WEISSENBERG W., KABA M., SEKULA O., Brugg Kabel AG, Switzerland
STREHL T., ELZE H., MARKALOUS S., LEMKE DIAGNOSTICS, Germany
A.7.4
Experience with PD measurements and commissioning tests
PULTRUM E., KEIZER HE., VERHOEVEN S.A.M., KEMA, Arnhem, Netherlands
A.7.5
Practical issues regarding the use of dielectric measurements to diagnose the service health of MV cables
HERNANDEZ J. C., HAMPTON R.N., HARLEY R., HARTLEIN R., Georgia Inst., ECE-NEETRAC, Atlanta, USA
A.7.6
Evolution of space charge and internal electric field distributions in HVDC cable under long term testing
MATALLANA J., JANAH H., MIREBEAU P., NEXANS France, Calais, France
SANDEN B., NEXANS Norway AS, Oslo, Norway
CASTELLON J., AGNEL S., NOTINGHER jr P., TOUREILLE A., LEM, Univ. de Montpellier, France
SESSION B.7 : HV / EHV DC CABLES
Tuesday June 26, 2007 - 16:30 - 18:00 - Room : B
top of page
Chairman :
M. SHULALOV - JSC "VNIIKP" (Russia)
Rapporteur :
TOUREILLE A - LEM Montpellier University (France)
B7 - Session Report
B.7.1
Development of extruded single core cables for deep waters
BERGKVIST M., HANSSON O., JEROENSE M., SONESSON C., ABB Power Systems, Karlskrona, Sweden
B.7.2
The Norned HVDC link – cable design and performance
WORZYK T., SJÖBERG M., ABB Power Systems, Karlskrona, Sweden
SKOG J.E., Statnett, Oslo, Norway
KOREMAN K., Tenne T, Arnhem, Netherlands
B.7.3
Development of DC +/- 250 kV coaxially-integrated return conductor extruded cable
HIRANO S., HARAGUCHI J., Electric Power Development, Tokyo, Japan
MIZUNO T., VISCAS Corporation, Ichihara, Japan
NAGOYA Y., VISCAS Corporation, Tokyo, Japan
B.7.4
Effect of semicon-insulation interface on space charge formation in HVDC polymeric cables
FABIANI D., MONTANARI G. C., University of Bologna, Italy
BODEGA R., PRYSMIAN C&S, Delft, Netherlands
DISSADO L.A., University of Leicester, UK
LAURENT C., TEYSSEDRE G., Université Paul Sabatier, Toulouse, France
CAMPUS A., NILSSON U. H. , BOREALIS AB, Stenungsund, Sweden
MORSHUIS P. H. F., Delft University of Technology, Netherlands
B.7.5
Measurement and modelling of space charge accumulation in polymeric HVDC cable systems
BODEGA R., PRYSMIAN C&S, Delft, Netherlands
MORSHUIS P. H. F., Delft University of Technology, Netherlands
PEREGO G., PRYSMIAN Cables & Systems, Milan, Italy
B.7.6
The use of model cables for evaluation of DC electrical properties of polymeric cable materials
NILSSON U. H., CAMPUS A., BOREALIS AB, Stenungsund, Sweden
MONTANARI G. C., University of Bologna, Italy
MORSHUIS P. H. F., Delft University of Technology, Netherlands
SESSION C.7.1 : AGEING
Tuesday June 26, 2007 - 16:30 - 18:00 - Room : C-Posters Session
top of page
Chairman :
G.C. MONTANARI - Bologna Univ. (Italia)
Rapporteur :
B. POISSON - SILEC CABLE (France)
C.7.1 - Session Report
C.7.1.1
A user-friendly tool for simulating the time-dependent field distribution in PE insulation on the basis of a physical approach
LE ROY S., BOUFAYED F., BAUDOIN F., TEYSSEDRE G., LAURENT C., Université Paul Sabatier, Toulouse, France
C.7.1.2
Computer simulation of measurements on XLPE cables
LYALL J., FOOTTIT F., Queensland University of Technology, Australia
C.7.1.3
Effect of cross-linking and antioxidant on the conductivity of the polyethylene
HOUABES M., University Badji Mokhtar of Annaba, Algeria
C.7.1.4
Annealing effect on the conductivity of XLPE insulation in power cable
BELANA J., ÒRRIT J., DIEGO J. A., MUDARRA M., Universidad de Catalunya, Barcelona, Spain
FRUTOS F., ACEDO M., Universidad de Sevilla, Spain
C.7.1.5
Effect of the dielectric strength test on dielectric properties
TAMUS Z. A., NÉMETH E., Budapest University of Technology, Hungary
C.7.1.6
Space charge measurements in XLPE insulated mid-voltage cable: correlation with cable performance.
TAMAYO I., ÒRRIT J., DIEGO J. A., Universidad de Catalunya, Barcelona, Spain
C.7.1.7
Water treeing test results for different XLPE compounds obtained with needle techniques
SHUVALOV M., OVSIENKO V., OBRAZTSOV Y., VNIIKP, Moscow, Russia
URBANCZYK A., BOREALIS, Poznan, Poland
BOSTRÖM JO., BOREALIS AB, Stenungsund, Sweden
C.7.1.8
Crosslinking and water treeing in polyethylene insulation
CIUPRINA F., University of Bucharest, Romania
FILIPPINI J., TEISSÈDRE G., LEMD - CNRS / UJF, Grenoble, France
CAMPUS A., SMEDBERG A., BOREALIS AB, Stenungsund, Sweden
C.7.1.9
Initiation site analysis of vented water trees growing from the conductor screen of service and laboratory aged XLPE cable insulation
JÄGER KM., SMEDBERG A., NILSSON U. H., BOREALIS AB, Stenungsund, Sweden
HVIDSTEN S., FAREMO H., SELSJORD M., SINTEF Energy Research, Trondheim, Norway
KVANDE S., NTNU, Dept. of Physics, Trondheim, Norway
C.7.1.10
Exploring the water treeing inhibition effect of antioxidants for XLPE insulation
MATEY G., LABBÉ D., Products and Marketing Ltd, Geneva, Switzerland
C.7.1.12
Study of thermally and water tree aged polyethylene by infrared spectroscopy, absorption currents and space charge measurements
STANCU C., NOTINGHER P. V., University Politehnica of Bucharest, Romania
NOTINGHER jr P., CASTELLON J., AGNEL S., TOUREILLE A., LEM, Univ. de Montpellier, France
RAKOWSKA A., SIODLA K., Poznan University of Technology, Poznan, Poland
C.7.1.13
Water treeing at high hydrostatic pressure and temperatures
FAREMO H., HVIDSTEN S., BENJAMINSEN J. T., SINTEF Energy Research, Trondheim, Norway
BØRNES A. H., Statoil ASA, Bergen, Norway
C.7.1.14
Improved understanding of MV cable performance through extensions of existing ageing protocols
HAMPTON R.N., HARTLEIN R., Georgia Inst., ECE-NEETRAC, Atlanta, USA
C.7.1.15
A molecular approach to the electrical aging of polymeric cables
CRINE JP., Technology Consultant, St Bruno, Canada
C.7.1.16
Kinetic modelling of phenol stabiliser efficiency in polyethylene submitted to nuclear environments
COLIN X., AUDOUIN L., VERDU J., ENSAM, Paris, France
MONCHY-LEROY C., EDF R&D, Moret-sur-Loing, France
C.7.1.17
A numerical method for 3D-description of scattered characteristic aging data from multistress aged XLPE-cable insulation
REUTER M., GOCKENBACH E., BORSI H., Schering Inst., Leibnitz Universität, Hannover, Germany
C.7.1.18
Understanding and optimization of long term ageing in cable industry
STUHLDREIER T., FOURNIER J., NEXANS Research Center, Lyon, France
C.7.1.19
Electrical and physico-chemical analysis of Belgium medium voltage cables data bank
CASTELLON J., AGNEL S., NOTINGHER jr P., TOUREILLE A., LEM, Univ. de Montpellier, France
BEAUGUITTE D., PLATBROOD G., TITS Y., LABORELEC, Linkebeek, Belgium
SESSION C.7.2 : DIAGNOSTIC & MAINTENANCE
Tuesday June 26, 2007 - 16:30 - 18:00 - Room : C-Posters Session
top of page
Chairman :
G. BOULBOL - LIBAN CABLES SAL (Lebanon)
Rapporteur :
B. DHUICK - SILEC CABLE (France)
C.7.2 - Session Report
C.7.2.1
Insulation diagnosis of high voltage power cables
GULSKI E., CICHECKI P., SMIT J. J., Delft University of Technology, Netherlands
DE VRIES F., Nuon Tecno, Alkmaar, Netherlands
SEITZ P. P. , QUAK B., Seitz Instruments AG, Niederrohrdorf, Switzerland
PETZOLD F., SebaKMT, Baunach, Germany
C.7.2.2
Wavelet analysis based scheme for fault detection and classification in underground power cable systems
CHOI H.W., MIN B.W., MYOUNG H.C., LEE B.H., Hyundai Heavy Industries, Kyounggi, South Korea
CHO S.M., NeoTelecom, Seoul, South Korea
C.7.2.3
Feasibility study on application of WIMAX technology to underground cables data acquisition
MYOUNG H.C., CHOI H.W., MIN B.W., PARK D.H., Hyundai Heavy Industries, Kyounggi, South Korea
KIM Y.J., NeoTelecom, Seoul, South Korea
C.7.2.4
Advanced solution for on-site diagnosis of distribution power cables
GULSKI E., SMIT J. J, Delft University of Technology, Netherlands
PETZOLD F., SebaKMT, Baunach, Germany
SEITZ P. P., QUAK B., Seitz Instruments AG, Niederrohrdorf, Switzerland
DE VRIES F., Nuon Tecno, Alkmaar, Netherlands
C.7.2.5
Experiences with PD offline diagnosis on MV cables – knowledge rules for asset decisions
PETZOLD F., BEIGERT M., SebaKMT, Baunach, Germany
GULSKI E., Delft University of Technology, Netherlands
C.7.2.6
Sensitivity verification procedure of VHF PD detection systems
MEIJER S., AGORIS P. D., SMIT J. J., Delft University of Technology, Netherlands
HERMANS T. J.W.H., LAMBALLAIS L., PRYSMIAN C&S, Delft, Netherlands
C.7.2.7
50 Hz Partial Discharge Diagnostics - experience of N-Ergie AG. Minimizing cable failures by reliability-centered maintenance of networks
VERSCHRAEGEN F., IMCORP Europe BVBA, Lochristi, Belgium
C.7.2.8
UHF Partial discharge diagnostic of plug-in cable terminations
GRUND R., KLEIN T., PFISTERER AG, Winterbach, Germany
DENISSOV D., University of Stuttgart, Ostfildern, Germany
C.7.2.9
On-site partial discharge testing of distribution class cables using VLF and power frequency excitation
GROSS D.W., SOELLER M., Power Diagnostix Systems GmbH, Aachen, Germany
C.7.2.10
Novel method for on-site testing and diagnosis of transmission cables up to 250 kV
SEITZ P. P., QUAK B., Seitz Instruments AG, Niederrohrdorf, Switzerland
GULSKI E., CICHECKI P., Delft University of Technology, Netherlands
DE VRIES F., Nuon Tecno, Alkmaar, Netherlands
PETZOLD F., SebaKMT, Baunach, Germany
C.7.2.11
Partial discharge diagnosis on live EHV power cable using planar UWB antenna
PARK N.J., SHIN D.H., LWIN K.S., YIM Y.C., PARK D.H., Wonkwang University, Iksan, South Korea
HWANG D.H., LIM J.C., Taihan Electric Wire, Seoul, South Korea
C.7.2.12
Leak location in oil paper cables
MEURICE D., EDF R&D, Moret-sur-Loing, France
LANZARONE L., RTE EDF Transport, Vitry-sur-Seine, France
LANDUCCI L., RTE EDF Transport, Courbevoie, France
C.7.2.13
Hydrogen elimination from a 225 kV HPOF pipe-type line
LINOIS P., RTE - TENP - GIMR, Nanterre, France
BONNARDOT G., RTE - TENP - GETSO, Guyancourt, France
C.7.2.14
Cable rejuvenation technology; past, present and future
STAGI W., CHATTERTON W., UtilX Corporation, Kent, USA
C.7.2.15
Monitoring based maintenance for underground cables utilizing sensor networks
MIN B.W., CHOI H.W., MYOUNG H.C., KIM J.H., Hyundai Heavy Industries, Kyounggi, South Korea
NAM S.B., NeoTelecom, Seoul, South Korea
C.7.2.16
Condition assessment of power cable systems in the energized state
SRINIVAS N., DTE Energy Technologies Inc, Novi, Michigan, USA
BERNSTEIN B., Bruce S. Bernstein Consulting LLC USA
C.7.2.17
Diagnostic Testing of MV Acessories by Time Domain Spectroscopy (TDS)
Affiliation
SESSION A.8 : CABLES & ENVIRONMENT
Wednesday June 27, 2007 - 9:00 - 10:30 - Room : A
top of page
Chairman :
A. GILLE - BEL Engineering (Belgium)
Rapporteur :
L. BENARD - PRYSMIAN C&S (France)
A8 - Session Report
A.8.1
Making remaining life predictions for power cables using reliability analyses
JEYAPALAN J. K., Camp Dresser & McKee, Wethersfield, USA
A.8.2
Oil replacement by water in unused oil-filled power cables
DARDEL B., MATTMANN J., JAQUENOD L., VAN-RYSSELBERGHE L., GEHRET S., KRÄEHENBÜEHL F., NEXANS Switzerland, Cortaillod, Switzerland
A.8.3
Environmental impacts in rural area of a HV underground link
GOURIT L., SERRES E., CHEVALIER P., RTE, National Centre for Grid Expertise, Paris, France
A.8.4
Passive loops technique for electromagnetic fields mitigation: applications and theoretical considerations.
MAIOLI P., ZACCONE E., PRYSMIAN Cables & Systems, Milan, Italy
A.8.5
Use of ecoconception software to design a HV cable connection
MIREBEAU P., NEXANS France, Calais, France
BENARD L., LEBOURDON F., PRYSMIAN, Paron, France
ARGAUT P., POILLEAUX F., POISSON B., SILEC CABLE, Montereau, France
A.8.6
Eco-conception, recycling and life cycle analysis in cable industry
BARBEAU S., GOUDEAU J., BURLET G., NEXANS Research Center, Lyon, France
SESSION B.8 : DESIGN (1)
Wednesday June 27, 2007 - 9:00 - 10:30 - Room : B
top of page
Chairman :
W. ZENGER - PG&E (USA)
Rapporteur :
F. LESUR - EDF R&D (France)
B8 - Session Report
B.8.1
The use of insulated wires Milliken conductors in high power transmission underground AC lines
DUBOIS D., MIREBEAU P., NEXANS France, Calais, France
B.8.2
Thermal and electromagnetic modelling of power umbilicals
KULBOTTEN H., LERVIK J. K., SINTEF Energy Research, Trondheim, Norway
NORMANN T., Aker Kvaerner Subsea, Lysaker, Norway
B.8.4
Current rating of cables installed in plastic ducts
MOREAU C., EDF R&D, Moret sur Loing, France
COURSET L., RTE CNER, Paris France
B.8.5
Verification of mechanical support for cables used on bridge structures at dilation point
ROUILLARD V., Victoria University, Melbourne, Australia
PIECHOTA R., Olex Australia, Tottenham, Australia
B.8.6
Measurements of thrust load in cable systems rigidly installed in duct / manhole structures
GEENE H. T. F., BODEGA R., VAN ROSSUM J. C. M., PRYSMIAN C&S, Delft, Netherlands
SESSION A.9 : SUBMARINE CABLES
Wednesday June 27, 2007 - 11:00 - 12:30 - Room : A
top of page
Chairman :
G. BALOG - NEXANS (Norway)
Rapporteur :
D. DUBOIS - NEXANS (France)
A9 - Session Report
A.9.1
Challenges of the second submarine interconnection between Spain and Morocco
GRANADINO R., PRIETO J., DENCHE G., Red Electrica de España, Madrid, Spain
MANSOURI F., Office National de L'Electricité, Casablanca, Morocco
STENSETH K., NEXANS Norway AS, Oslo, Norway
COMELLINI R., PRYSMIAN Cables & Systems, Milan, Italy
A.9.2
Electrical and thermal design of umbilical cable
SHACKLETON D., Oceaneering Multiflex, Rosyth, UK
ABIB L., Marine Production Systems do Brasil, Rio de Janeiro, Brazil
A.9.3
Qualification, supply and installation of the world's first 420 kV XLPE submarine cable system in Norway
EVENSET G., KNUTSEN B., NEXANS Norway AS, Oslo, Norway
LARSEN J. E., FAUGSTAD K., Stattnett SF, Oslo, Norway
A.9.4
Advances in chemical rejuvenation of submarine cables
BERTINI G. J., Novinium Inc., Kent, USA
A.9.5
Subsea connections to high capacity offshore windfarms: issues for consideration
SVOMA R., WILLIAMS L., PowerSure Technology, Bexleyheath, London, UK
A.9.6
Application of temperature sensing and dynamic strain monitoring to subsea cable technology
KLUTH R., Sensornet, Elstree, Hertfordshire, UK
SVOMA R., WILLIAMS L., PowerSure Technology, Bexleyheath, London, UK
SESSION B.9 : DESIGN (2)
Wednesday June 27, 2007 - 11:00 - 12:30 - Room : B
top of page
Chairman :
R. ROSEVEAR - Southampton Dielectric Consultants (UK)
Rapporteur :
Ch. MOREAU - EDF R&D (France)
B9 - Session Report
B.9.1
Sensitivity of PD inception to change of electrical design in polymeric insulated cable systems
VAN SCHAIK N., VAN DER WIELEN P., KEMA-TDT, Arnhem, Netherlands
CZASZEJKO T., Monash University, Clayton, Australia
B.9.2
Tools for understanding the thermo-electrical behaviour of XLPE insulation in power cables and accessories
LE ROY S., BAUDOIN F., TEYSSEDRE G., LAURENT C., Université Paul Sabatier, Toulouse, France
DISSADO L.A., University of Leicester, UK
MONTANARI G. C., University of Bologna, Italy
B.9.3
Improvements in superabsorbent water blocking materials for new power cable applications
CZUPRYNA S., EVERAERE J., Geca Tapes b.v., Bailleul, France
DELATTRE M., PGI Nordlys, Bailleul, France
B.9.4
Power cable modeling under power electronic converter constraints
WEENS Y., IDIR N., FRANCHAUD J.J., BAUSIERE R., Université des Sces et Techn. de Lille, France
B.9.5
Longitudinal induction voltage measurement on communication cables running parallel to overhead lines or power cables
SHARAFI D., Western Power Corporation, Perth, Australia
KLAPPER U., Omicron electronics, Klaus, Austria
B.9.6
K-factor measurement of cables for optimum reliability of distance protection and fault locators
KLAPPER U., Omicron electronics, Klaus, Austria
FICKERT L., Technical University of Graz, Austria
B.9.7
Sheath circulating current calculations and measurements of underground power cables
CHEN X., CHENG Y., WU K., Xi'an Jiaotong University, Xi'an, Shaanxi, China
SESSION A.10 : TESTING (2)
Wednesday June 27, 2007 - 14:30 - 16:00 - Room : A
top of page
Chairman :
J-Y. KOO- HANYANG Univ. (Korea)
Rapporteur :
P. PENSERINI - EDF R&D (France)
A10 - Session Report
A.10.1
Comparison of different analytical test methods to monitor crosslinking by-products in XLPE insulated cables
SMEDBERG A., BOSTRÖM JO., BOREALIS AB, Stenungsund, Sweden
WALD D., PETERS R., BOREALIS Polymers NV, Mechelen, Belgium
A.10.2
Breakdown caused by abrupt DC-voltage grounding of XLPE cable insulation
ILDSTAD E., MAUSETH F.., Norwegian University of Sc.and Tech., Trondheim, Norway
SELSJORD M., HEGERBERG R., SINTEF Energy Research, Trondheim, Norway
SANDEN B., NEXANS Norway AS, Oslo, Norway
JEROENSE M., ABB Power Systems, Karlskrona, Sweden
LARSEN J. E., Stattnett SF, Oslo, Norway
A.10.3
New approach to measure conductor temperature during type test
PULTRUM E., SLOOT W., VERHOEVEN S.A.M., KEMA, Arnhem, Netherlands
A.10.4
After-installation testing of HV / EHV extruded cable systems – procedures and experiences
PLATH R., HERRMANN U., IPH, Berlin, Germany
A.10.5
HV AC testing of super-long cables and gas-insulated lines in factory and on-site
SCHIERIG S., HAUSCHILD W., COORS P., TU Dresden, Dresden, Germany
A.10.6
Type testing of a 13.2 kV, 69 MVA TRIAX HTS cable
WILLÉN D., NKT Cables, Brondby, Denmark
SESSION B.10 : ECONOMY OF CABLE SYSTEMS
Wednesday June 27, 2007 - 14:30 - 16:00 - Room : B
top of page
Chairman :
M. de SIQUIERA CAMPOS ARAUJO - BRENNAND Energia (Brazil)
Rapporteur :
Ch. FAVRIE - SYCABEL (France)
B10 - Session Report
I.10.01
Economics of EHV Cable Systems
ALLEN S., ICF International, UK
I.10.02
Distribution lines ans cables in France: present situation and trends
HORVILLEUR J., ERD, France
I.10.03
Economical aspects for RTE grid
ROINEL G., RTE, France
B.10.1
Challenges & opportunities of installing HV cable in Australia & Sri Lanka
RAHMAN N., BARBER K., Olex Australia, Tottenham, Australia
B.10.2
Aluminium conductors in anti-robbery cables
DE PAULA J. A., ROSA L. H., UEDA S., NEXANS Brasil, São Paulo, Brazil
B.10.3
Design of a 45 circuit duct bank
COATES M., ERA Technology Ltd, Leatherhead, UK
O'SULLIVAN L., EDF Energy Networks, Bexleyheath/Kent, UK
B.10.6
Barrier optimization algorithm applied to calculation of optimal loading of dissimilar cables in one trench
ANDERS G. J., Kinectrics Inc., Toronto, Canada
MOUTASSAM W., University of Toronto, Canada
SESSION A.11 : CLOSING SESSION
Wednesday June 27, 2007 - 16:30 - 18:00 - Room : A
top of page
Round Table :
The Round Table was organized about the following topic:
"Long lenghts EHV electrical links by AC insulated power cables in the world"
with the following contributions:
Jicable Award
The Jicable'07 prize was awarded to Christian Royer and Ray Awad, Hydro-Quebec Canada, for their work (Session B4):
"Evaluation of the condition and the performance of underground fluid filled HV links at Hydro-Quebec"