JICABLE : All proceedings

From Jicable'84 to Jicable'11

Please find herafter, the list of all proceedings from Jicable '84 to the last conference Jicable'11

RESEARCH : You may use the "search on this page" property of your browser to locate a relevant proceeding according to key words (limited to this page).

The first page of the proceeding is associated with the link

A search function is also available. It searches within the whole first page of all proceedings.

A full pdf version of any proceeding could be sent free of charges, upon nominative request by mail.

1984 - A1-1

Low-voltage overhead networks and trappings using insulated conductors

PARIS Michel, SCHWAB Anne-Marie; EDF-DER; Clamart, France

1984 - A1-2

Insulated cables for aerial networks with A.C. rated voltages up to 1 kV Specifications and installation rules

BECKER J., BOURJOT P, GASPARINI G.; Câblerie de Charleroi - CDC; Charleroi, Belgique

BORRAS FIGUERAS Tomas; SAENGER; Barcelona, Spain

BOURJOT Pierre; CEAT; Poissy, France

GASPARINI Georgio; CEAT CAVI; Torino, Italy

1984 - A1-3

Distribution cables at Electricité de France. Technological evolutions of cables and accessories

SCHMELTZ Jacques; EDF Direction de la Distribution; Paris la Défense, France

FERRAN Jacques, LOUET Maurice; EDF Direction de la Distribution; Paris la Défense, France

1984 - A1-4

Developments in medium voltage polymeric cables

ROSS Alec; Eastern Electric Board; Ipswich, UK.

1984 - A2-1

Progress with XLPE insulated medium voltage cables in the Federal Republic of Germany

SCHUPPE Wolf Dieter; AEG KABEL; Monchengladbach, Germany

1984 - A2-2

MV and HV crosslinked material insulated cables manufactured in different European countries. Typology - Use - Prospects

BECKER J.; Câblerie de Charleroi-CDC; Charleroi, Belgique

GASPARINI Georgio; CEAT CAVI; Torino, Italy

MONTEYS J.; ROQUE; Barcelona, Spain

ROY Daniel; CFG; Sens, France

1984 - A2-3

A new one step crosslinking process for MV cables

HOCHSTRASSER U.P.; MAILLEFER; Ecublens Lausanne, Switzerland

1984 - A2-4

Polyethylene insulated medium voltage cables with solid aluminium conductors. aluminium screens and aluminium neutrals

KARDOS George; Hungarian Cable Works; Budapest, Hungria

1984 - A3-1

Some aspects of compatibility and short circuit characteristics of medium voltage polymeric cables

RATRA M.C.; Central Research Institute Bagalore-India; Bangalore, India

1984 - A3-3

Performance of EPR insulated cables under different laying conditions and unusual thermal stresses

FARNETI F.; ENEL Centro di Ricerca Elettrica; Cologno Monzese, Italy

METRA P., PORTI NARI G.; CAVI PIRELLI; Milano, Italy

BERTANI E., MOSCA Walter; CESI; Milano, Italy

1984 - A3-4

Thermomechanical behaviour and watertightness of MV polymer insulated cables

BOURJOT Pierre; CEAT; Poissy, France

GAUTHIER Pierre; TREFICABLE PIRELLI; Amfreville-la-mi-voie, France

PINET Alain; EDF-DER; Moret sur Loing, France

1984 - A4-1

Failure rate estimating tests of PE insulated power cables for voltages up to 12/20 kV

GARBARSKI Marek; ENERGOKABEL; Varsovie, Poland

GROBICKI Jan; ENERGOKABEL; Varsovie, Poland

1984 - A4-2

Reliability control of cables by tests in situ

MOHR P.F, SMAJLER Adolf J.; CABLERIE DATWYLER; Altdorf/UR, Switzerland

1984 - A4-3

AC test methods used for 11 kV extruded cable in CEGB power stations

WILSON A., SWINGLER S.G; CEGB-CERL; Leatherhead, Surrey, UK

HALL L.; CEGB-SE Region; Dartford, Kent, UK

1984 - A4-4

Quality evaluation of accessories for MV polymeric cables

DUCHATEAU Francis., PINET Alain; EDF-DER; Moret sur Loing, France

1984 - A5-1

The influence of testing conditions on the electrical behaviour of contaminated insulation compound

MATEY Gabriel; BP CHEMICALS Chemicals and Plastics Laboratory; Meyrin, Switzerland

1984 - A5-2

Water treeing and electrical treeing

FILIPPINI J.C., KOO J.Y., POGGI Y.; CNRS Laboratoire d'Electrostatique et de Matériaux Diélectriques; Grenoble, France.

LAURENT Christian, MAYOUX Christian, NOEL S.; Université Paul Sabatier Laboratoire de Génie Electrique; Toulouse, France

1984 - A5-3

Measurement of water tree penetration by neutron activation analysis

CRICHTON B.H., GIVEN M.J., FARISH O.; University of Strathclyde Dept.of Electronic and Electrical Engg; Glasgow G1 1XW, UK

BANFORD H.M.; SCOTTISH UNIVERSITIES Research and Reactor Center; GLASGOW G1 1XW, UK

1984 - A5-4

Ageing of polyethylene power cables saturated with water

RYNKOWSKI Adam W, BORYN Henryk, WOJTAS Stanislaw; Technical University of Gdansk; Poland

1984 - A6-1

Factors affecting the dielectric strength of extruded dielectric cables in wet environment

SILVER David A, LUKAC R.G.; PIRELLI CABLE; Union, NJ 07083, USA

1984 - A6-2

Life estimation and improvement of water-tree resistivity of XLPE cables

NAGASAKI S., MATSUBARA H., YAMANOUCHI S., MATSUIKE T., FUKUNAGA S., KEISHI T.; Sumitomo Electric Industries; Osaka, Japan

1984 - A6-3

Testing possibilities and results regarding water aging of PE/XLPE insulated medium voltage cables

FRANKE Hermann, HEUMANN Heinz, KAUBISCH Dieter; AEG KABEL; Monchengladbach, Germany

1984 - A6-4

Water tree deterioration and counter measure of low and medium voltage XLPE cables

TANABE Teruyoshi, SAKURAI T., KIKUCHI K., FUKUDA T.; FURUKAWA ELECTRIC; Ichihora, Chiba, Japan

1984 - A6-5

Influence of water on dielectric strength and rejuvenation of in-service aged URD cables

KATZ C., EAGER Jr G.S.; CABLE TECHNOLOGY LABS; New Brunswick, NJ, USA

LEBER Eric R.; AMERICAN PUBLIC POWER; Washington DC, USA

FISCHER Frank E.; ORANGE &ROCKLAND UTILITIES; Pearl River, NJ, USA

1984 - A6-6

Advances in crosslinking polyethylene insulation for medium and high voltage cables

FISHER E-J.; UNION CARBIDE Wire & Cable Materials Export; Danbury, CT 06817, USA

1984 - A7-1

Cable fire testing to meet realistic design criteria

BERRY D.L., KLAMERUS L.J.; SANDIA NATIONAL LABORATORIES; Albuquerque, NM 87185, USA

1984 - A7-2

Cables having improved fire performance

PHILBRICK S.E., McCONNELL J.; PIRELLI GENERAL; Eastleigh, United Kingdom

1984 - A7-3

New cables designed to limiting the risk of proceeding from a fire

KIRCHNER François; CEAT; Poissy, France

GUERZIO M.; CEAT CAVI; Torino, Italy

VILLAGRASA F.; GENERAL CABLE CEAT; Barcelona, Spain

1984 - A7-4

Improvement of the behaviour of cables in fire. Application to nuclear power stations

BERETTA G.; CAVI PIRELLI; Milano, Italy

SIMON Claude; TREFICABLE PIRELLI; Saint Maurice, France.

1984 - A8-1

Electric cables and their fire behaviour : evolution of design and future prospects

COTTART J.J., LECOQ Yves, VILLEMAGNE M.; THOMSON JEUMONT CABLES; Bohain, France

1984 - A8-2

Cables with reduced smoke, toxicity and fire propagation

SABISTON A.D.; AEI CABLES; Gravesend, Kent, UK.

1984 - A8-3

Irradiation cross-Linking applied to non halogenated cable manufacturing

BERTIER D., BRUNEAU C., JOLY B.; ACOME; Paris, France

1984 - A8-4

Halogen-free crosslinkable materials. Application to electric cables and fire behaviour

DEMAY J.N. ,MALFROY J.; LES CABLES DE LYON; Lyon, France

1984 - A9-1

Fireproof thermoplastic halogen-free material for insulated cables

ROSSIGNOL G., FAVRIE C.; SILEC; Montereau, France

1984 - A9-2

Halogenated elastomers versatile cable jacket materials (the role of different classes of elastomers in the fire situation)

SWEET G.C.; DU PONT UK; Hemel Hempstead, UK

1984 - A9-3

Reduced fire propagation and low smoke emission requirements for power station cables

BARBER M.D., PARTRIDGE P.F.; CEGB; GLOUCESTER, UK

GIBBONS J.A.M.; CEGB; Leatherhead, Surrey, UK

1984 - A9-4

Cables with improved fire behaviour : recent tests results, applications in prospect

PAYS Michel, PARIS Michel,; EDF-DER; Moret sur Loing, France

1984 - A9-5

Development of haloqen-free cables in the Paris métro

CHATIRICHVILI G.; RATP Service du Contrôle et du Laboratoire; Paris, France

1984 - B1-1

Moisture barrier power cable with a plastic-metal laminate sheath

BOW Kenneth E.; DOW CHEMICAL; Granville, OH, USA

1984 - B1-2

Performance of ethylene-propylene rubber insulation in medium and high voltage power cables

BROWN Morton; DU PONT DE NEMOURS; Wilmington, DE, USA

1984 - B1-3

Cable belt new structure including semi conducting material and allowing simultaneously continuous earthing of the screens and protection against moisture and corrosion

BERTIER D., LEMOLTON J.; ACOME; Mortain, France

CLAUDE B.; TOTAL-CFR; Harfleur, France

1984 - B1-4

Crosslinking behaviour of EVA copolymers

QUAAS Gerwolf; BAYER; Leverkusen, Germany

1984 - B2-1

Crosslinked polyethylene for high-voltage cables with synthetic insulation

CAILLOT C., PARIS M., PERRET J.; EDF-DER; Clamart, France

1984 - B2-2

Materials testing of aged polymer insulated cables

BERNSTEIN Bruce S.; ELECTRIC POWER RESEARCH INSTITUTE; Washington DC, USA

1984 - B2-3

Materials research on extruded power cables

AZAROFF Leonid V.; University of Connecticut Institute of Materials Science; STORRS, CT 06268, USA

1984 - B2-4

Measurement and process control of internal stresses in LDPE power cables insulation

DE BELLET J.J., SCHIRATO P.; BP CHEMICALS Chemicals and Plastics Laboratory; Meyrin / Genève, Switzerland

1984 - B2-5

Study of silane-crosslinked materials for cable insulation

de ZELICOURT Y., PRIGENT M.; LABORATOIRES DE MARCOUSSIS; Marcoussis, France

HAUDIN; CEMEF; Valbonne, France

SCHULTZ; Laboratoire de Recherches sur la Physico-Chimie des Interfaces; Mulhouse, France

1984 - B3-1

Effect of temperature rise on leakage current and breakdown of XLPE cables

ABED Youssif A., EISH Taher D.; EL-MANSOURA UNIVERSITY; Egypt

1984 - B3-2

Development of a new insulating material for DC XLPE cables

FUKAGAWA Hiromasa, NITTA Yoshitaka; CRIEPI-Central Research Institute of Electric; Tokyo, Japan

SEKII Yasuo; HITACHI CABLE WORKS; HITACHIJAPON

1984 - B3-3

D.C. dielectric behaviour of low density polyethylene. Influence of pressure - utilization prospects

PERRET J., PAYS Michel; EDF-DER; Clamart, France

BUI AI, HOANG THE GIAM, GUERIN P.; Université Paul Sabatier Laboratoire de Génie Electrique; Toulouse, France

1984 - B3-4

The potential of extruded XLPE for cryogenic power cables

RABINOWITZ Mario; ELECTRIC POWER RESEARCH INSTITUTE; Palo Alto, CA, USA

SOSNOWSKI Marek; CABLE TECHNOLOGY LABS; New Brunswick, NJ, USA

1984 - B4-1

Review of Italian experience on M.V. submarine cables insulated with synthetic extruded materials

GIUSSANI Alberto, BRACCO Gianluigi; CAVI PIRELLI; Milano, Italy

1984 - B4-2

Watertight medium voltage submarine cables

BAYARD Claude, GAUBERT J.B.; LES CABLES DE LYON; Bourg en Bresse, France

1984 - B4-3

Testing of a high voltage XLPE cable for dynamic submarine application

SODEN J.E., TRAUT R.T.; SIMPLEX WIRE AND CABLE; USA

SAINT ONGE Hugues, TRAIN D.; Institut de Recherches d’Hydro-Québec; Varennes Québec, Canada

1984 - B5-1

New high voltage terminals developed to meet high working temperatures

DEJEAN Pierre-Marcel, FRETIER P., REDOLAT Raymond; CGF; Sens, France

1984 - B5-2

High-voltage accessories for XLPE insulated cables 52/170 kV. Design and experience of stress cones in EPDM rubber

HEDMAN Leif; KABELDON; Alingsas, Sweden

1984 - B5-3

New type of prefabricated terminals for EHV synthetic insulated cables

AUCLAIR H., DHUICQ B.; SILEC; Montereau, France

1984 - B5-4

Electrical dimensioning of cables joints with cross bonded sheaths

BERNARD G., DORISON E., PICHE F., SABOT A.; EDF-DER; Moret sur Loing, France

1984 - B5-5

After laying test of HV and EHV cables

DORISON Eric, AUCOURT Christian; EDF-DER; Moret sur Loing, France

1984 - B6-1

The experience in service for 66 kV XLPE insulated power cables

TAKENOUCHI K., NAKAGAWA H., NAKABASAMI T., KATSUMATA A.; TOKYO ELECTRIC POWER; Tokio, Japan

1984 - B6-2

Development and installation of 154 kV XLPE cables

NAKAGAWA H., NAKABASAMI T.; TOKYO ELECTRIC POWER; Tokio, Japan

TANABE Teruyoshi; FURUKAWA ELECTRIC; Ichihora, Chiba, Japan

AIHARA M.; Showa Electric Wire & Cable; Kawasaki, Japan

KONDA A.; Sumitomo Electric Industries; Osaka, Japan

1984 - B6-3

Actual installation of short distance 275 kV XLPE cables and technical development for long distance installation

WATANABE Y., NAKAGAWA H.; TOKYO ELECTRIC POWER; Tokio, Japan

SUGIYAMA K.; DAINICHI NIPPON CABLES; Tokyo, Japan

ONO M.; Fujikura Ltd; Tokyo, Japan

SEKII Yasuo; HITACHI CABLE WORKS; HITACHIJAPON

1984 - B6-4

The synthetic extruded insulation cables in the power transmission network of Electricité de France

CUCHE M., ROYERE A.; EDF-CERT; Paris 08, France

LEPERS J.; EDF-CRTT; Boulogne Billancourt, France

1984 - B6-5

EPR insulated cables for voltages ranging from 6/10 to 87/150 kV. Developments, tests and achievements

SCHMID M., SCHMIDT B.R., CONTALBRIGO E., LAURENT M.; CABLERIES ET TREFILERIES DE COSSONAY; Cossonay Gare, Switzerland

1984 - B7-1

XLPE cable properties after long time service at E.H. voltage levels

WRETEMARK Sven, NELIN Göran; SIEVERTS KABELVERK; Sundbyberg, Sweden

1984 - B7-2

Projects in the field of 225 kV EHV cables with low-density polyethylene insulation

FAVRIE Eugène; SILEC; Montereau, France

1984 - B7-3

Development of 500 kV bulk power XLPE cable and accessories

TAKAOKA M., MOHTAI T., ONO M., KAJI I.; Fujikura Ltd; Tokyo, Japan

1984 - B7-4

New catenary extrusion line designed for HV and EHV cables

MIDOZ Jacques; TREFICABLE PIRELLI; Saint Maurice, France.

1984 - B7-5

Development of various snaking installation methods of cables in Japan

NAKAGAWA H., NAKABASAMI T.; TOKYO ELECTRIC POWER; Tokio, Japan

SUGIYAMA,K., SHIMADA A.; DAINICHI NIPPON CABLES; Tokyo, Japan

1984 - C-1

New solutions in connecting, tap-off, energizing and measuring in medium voltage work

SANDER Dieter; KARL PFISTERER; Stuttgart Germany

1984 - C-10

Terminations and joints for medium voltage XLPE insulated cables containing water

WIKMAR Kjell; KABELDON; Alingsas, Sweden

1984 - C-11

Material accessories for LV aerial bundled conductors

LIENART Jean-Pierre; MAUCO; Fontaine, France

1984 - C-12

Halogen-free fire resistive joints for low and medium voltage cables

BESSEl Herbert, JOHN Gunther; 3 M ELECTRICAL LABORATORIES; Hambourg, Germany

1984 - C-13

Accessories for halogen-free fire-retardant and fire-resistant cables

BEYERSDORFFER Kurt W., TAMPLIN P.; RAYCHEM; Putzbrunn / Munchen, RFA

1984 - C-14

Evolution of pulling and laying equipment

GATTEGNO Michel; GATTEGNO; Noisy le Sec, France

1984 - C-15

Termination and high voltage direct current cable suitable for the current supply of electrostatic fibers

DEJEAN Pierre-Marcel; CGF; Sens, France

BORRAS FIGUERAS Tomas; SAENGER; Barcelona, Spain

1984 - C-16

Application of mica-tapes in fire resistant cables

GAUER Peter; SWISS INSULATING WORKS; Breitenbach, Switzerland

1984 - C-17

Conductive and non conductive waterswellable nonwovens for longitudinal waterblocking

NIEUWHOF B.J.; FIRET; Veenendaal, The Netherlands

1984 - C-18

Insulation process of synthetic materials with a multiscrew two stages extruder

ARElAS Guy; EMS EXTRUSION; St Witz, France

1984 - C-19

The possible intervention of the field enhanced ion absorption effect in the phenomenon of water treeing

TOBAZEON R.; CNRS / Laboratoire d'Electrostatique et de Matériaux diélectriques; Grenoble, France.

1984 - C-2

Heat-shrink cable accessories for plastic cables up to 36 kV

HAVERKAMP Wolfgang, LE BAUT Pierre-Yves; RAYCHEM; Saint Ouen l'Aumone, France

1984 - C-20

Location of partial discharges in drum length cables

SMITH A.P.; AEI CABLES; Gravesend, Kent, UK.

1984 - C-21

Measuring and Locating of partial discharges in power cables

SZALOKY G.; HAEFELY; Basel, Switzerland

SCHWARZ M.; KABELWERKE BRUGG; Brugg, Switzerland

1984 - C-22

Carboxymethylcellulose and water tightness of cables

MOMBELLET Henri; HERCULES; Alizay, France

1984 - C-3

New connecting equipment for MV synthetic insulated cables

CHAZELAS E., ARETTE-HOURQUET D.; SILEC; Montereau, France

1984 - C-5

Preinsulated connection equipment for LV insulated bundled overhead lines

JACQUENET J., JOANNY G.; SIMEL; Gevrey Chambertin, France

1984 - C-6

Premoulded cable connector system for today and tomorrow

CHATTERJEE Shotu; AMERACE; Erembodegem, Belgique

1984 - C-7

Elastic moulded components for terminations of synthetic insulation power cables

BATAILLE C., DRUMONT C.; TREFICABLE PIRELLI; Saint Maurice, France.

1984 - C-9

Development of factory molded splices to meet the requirements of advanced synthetic insulated medium voltage cable designs

VARNER Wayne F.; 3 M; Saint Paul, MN, USA

1987 - A10-1

Development of methods to estimate the residual life of XLPE cables deteriorated by water trees

FUKAGAWA Hiromasa, OKAMOTO T., HOZUMI N., SHIBATA T.; CRIEPI, Yokosuka Research Lab; Yokosuka, Japan

1987 - A10-2

Diagnostic method for high voltage XLPE insulated cable in the field

HIRATAT., FUJIGAKI S.; Chubu Electric Power Co.; Nagoya, Japan

SUGIYAMA K., INAMI.M; Mitsubishi Cable Industries; Tokyo, Japan

TAKEHANA H.; Fujikura Ltd; Tokyo, Japan

1987 - A10-3

Investigation on deterioration of 22 to 66 kV XLPE cables removed from actual service lines

MATSUURA K.; OSAKA UNIVERSITY; Japan

OHNO H., ISHIBASHI A; TOKYO ELECTRIC POWER; Tokio, Japan

YATSUKA K., HIROTSU K.; SUMITOMO ELECTRICINDUSTRIES; Osaka, Japan

KAJIKI 1., SHINAGAWA J.; Showa Electric Wire & Cable; Kawasaki, Japan

1987 - A10-4

Present condition of XLPE cables used in Japan and cable fault analysis

JINNO M., KOBASHI K; Kansai Electric Power Co; Osaka, Japan

TANABE Teruyoshi, ASADA Y.; FURUKAWA ELECTRIC; Tokyo, Japan

1987 - A10-5

Evaluation of long-term electric strength of polymer insulated HV and VHV cables

MESHCHANOV G.I., SHUVALOV M.Y.,GLEIZER S.E., MAKAROV L.E.; ALL UNION CABLE RESEARCH INSTITUTE; Moscow, USSR

1987 - A1-1

Dielectric performances of the 20 kV XLPE cable used in France

PINET Alain, PAYS Michel; EDF-DER/ERMEL; Moret-sur-Loing, France

1987 - A1-2

Comparative performances of EPDM versus XLPE as insulation for distribution cables

CHAN John C., HIIVALA Lauri J.; CANADA WIRE & CABLE; Toronto, Canada

1987 - A1-3

Elevated temperature operation of XLPE distribution cable systems

ORTON Harry E., FLETCHER R.G., CARTLIDGE D.M., BRADLEY J.F., COLWELL M.J., WONG J.Y.; BC HYDRO RESEARCH AND DEVELOPMENT; Surrey, Canada

1987 - A1-4

Comparison of thermal cycling effects on 11 kV XLPE insulated cables with solid and stranded aluminium conductors

HOWARD Roy S., ROSS Alex; EASTERN ELECTRIC BOARD; Ipswich, UK.

1987 - A2-1

The use of self-adhesion tapes for MV and HV accessories

METZGER Gisèle, DUCHATEAU F.; EDF-DER/ERMEL; Clamart, France

1987 - A2-2

Research on heat shrinkable accessories

WANG WEI; MINISTRY OF WATER RESOURCES AND ELECTRIC POWER; Wuhan, PR of China

1987 - A2-3

High voltage transition joints between plastic and paper insulated cables of up to 41.5 kV rating using heat shrinkable components

HAVERKAMP Wolfgang L., HEY S.A., WILCK M.H.; RAYCHEM; München, Germany

1987 - A2-4

A new generation of modular elastic MV cable termination

TARDIF Laurent; TREFICABLE PIRELLI; Saint Maurice, France.

VALLAURI U.; CAVI PIRELLI; Milano, Italy

FRANKS R.; PIRELLI GENERAL; Eastleigh, United Kingdom

1987 - A3-1

Improved fire behavior security cables service voltage 1000 V

BOURJOT Pierre; FILERGIE; Poissy, France

1987 - A3-2

Development of cables with improved fire performance characteristics

JOURNEAUX Terence L.; PIRELLI GENERAL; Southampton, UK.

BERETTA G.; CAVI PIRELLI; Milano, Italy

GAUTIER Pierre; TREFICABLE PIRELLI; Saint Maurice, France.

1987 - A3-3

New halogen-free cables with reduced toxic gases

HASEGAWA Masatake, SUNAZUKA H., SEKIGUCHI Y.,KIMURA C., YOSHINO A.; Fujikura Ltd; Tokyo, Japan.

1987 - A3-4

Fire performance of insulating and jacketing materials

O'NEILL Thomas J.; DU PONT UK; Hemel Hempstead, UK

RYAN J.D.; DU PONT DE NEMOURS & CO.; Wilmington, DE, USA

1987 - A3-5

Fire resistance of cable installations

KULBOTTEN Harald, NYBERG Bjorn R.; EFI Norwegian Research Institute of Electricity Suppl; Trondheim, Norway

1987 - A4-1

Water, temperature and space charge influence on the breakdown of XLPE cables under divergent fields

TAHER D. EISH, FAHTI M.H. YOLlSSE; MANSOURA UNIVERSITY Electrical Eng. Dpte; Egypt.

1987 - A4-2

Accelerated ageing to predict watertree behaviour in extruded cables

STEENNIS Evert Frederik, VAN DE HEUVEL C.C., BOONE Wim; KEMA LABORATORIES; Arnhem, The Netherlands

1987 - A4-3

Influence of water on XLPE insulated MV cables

GEERTS G., ROBERT Alain; Laborelec; Linkebeek, Belgium

1987 - A4-4

Water treeing in XLPE insulated cables at 5U

MATEY Gabriel, NICOULAZ Francis; BP CHEMICALS; Meyrin, Switzerland

1987 - A5-1

Long term ageing of water immersed XLPE Insulations

MARSH Timothy G., SMITH A.P., DRYSDALE J.; AEI CABLES; Gravesend, Kent, UK.

1987 - A5-2

Characterization of extruded insulation cables with respect to effects of water

FARNETI F.; ENEL; Milano, Italy

METRA P.; CAVI PIRELLI; Milano, Italy

ORTIZ M.R.; PIRELLI BRASILEIRA; Sao Paulo, Brazil

1987 - A5-3

Growth of water trees and their influence upon the breakdown strength of EPR materials

FAREMO HaJlvard; EFI; Trondheim, Norway

1987 - A6-1

Ionic impurities in extruded cable insulation : analytical detection techniques, sources, nature and effects

MASHIKIAN Matthew S., GROEGER Joseph H.; University of Connecticut Electrical Insulation Research Center; Storrs, USA

1987 - A6-2

Elemental and ionic impurities in cable insulation and shields

CRINE Jean Pierre, PELISSOU Serge, ST-ONGE Hugues; IREQ; Varennes Québec, Canada

ST-PIERRE J., KENNEDY G.; Ecole Polytechnique de Montréal; Québec, Canada

HOUDAYER A., HINRICHSEN P.,; UNIVERSITE DE MONTREAL; Québec, Canada

1987 - A6-3

The role of N2 impregnation and ultraviolet, stabilizers in polymeric insulated high voltage cables

BAMJI Soli S., BULINSKI A.T., IDENSLEY R.J; NATIONAL RESEARCH COUNCIL; Ottawa, Canada

1987 - A6-4

Influence of the manufacturing process of LDPE on its behaviour under electric stress

CHAPEAU F., ALQUIE C., LEWINiER J.; ESPC; Paris, France

AUCLAIR H., JOCTEUR R.; SILEC; Montereau, France

1987 - A7-1

High voltage cable threshold fields and reliability

SIMON Claude; TREFICABLE PIRELLI; Saint Maurice, France.

1987 - A7-2

A study on the development of a free strippable thermosetting outer semiconductive compound for power cable

BAE HUN-JAI, HAN KEE-MAN, CHOI JONG-CHEOL, PARK SEONG-KEUN; GOLD STAR CABLE; Seoul, Korea

1987 - A7-3

The development of a water tree retardant XLPE insulatio

KIMURA Hitoshi, MUTO Hideji, IRIE Shinichi; FURUKAWAELECTRIC; Chiba, Japan.

1987 - A7-4

Development of a new insulating material for power cables

KOJIMA Shinji, y AZAKI F.; NIPPON PETROCHEMICALS; Kawasaki, Japan

IKEDA M., OHKI Y.; WASEDA UNIVERSITY; Tokyo, Japan

HOZUMI N.; CENTRAL RESEARCH INSTITUTE OF ELECTRIC POWER INDUSTRY; Tokyo, Japan

1987 - A8-1

EPR high voltage cables

ORTIZ M.R.; PIRELLI BRASILlEIRA; Sao Paulo, Brazil

LANFRANCONI G.M., VECELLIO B.; CAVI PIRELLI; Milano, Italy

1987 - A8-2

New development for HV cables

AUCOURT C., DORISON E.; EDF-DER/ERMEL; Moret-sur-Loing, France

1987 - A8-3

HV cables with corrugated laminate aluminium sheath : construction, characteristics, laying advantages

FONDEUR Jean Hubert, DEJEAN Pierre M.; FILERGIE; Paron Sens, France

1987 - A8-4

Development of a rapid-fitting pre-moulded joint for extruded insulation cables up to 275 kV

PARMIGIANI Bruno, VALLAURI U.; CAVI PIRELLI; Milano, Italy

1987 - A8-5

Dévelopment in France of the 400 kV LOPE insulated cable

AUCLAIR Henri, DHUICQ, FAVRIE Eugène; SILEC; Montereau, France

1987 - A9-1

Evaluation of ageing in transmission and distribution extruded dielectric cables

CRINE Jean Pierre, ST-ONGE Hugues; IREQ; Varennes Québec, Canada

1987 - A9-2

Investigations of polyethylene insulation resistivity of power cables

WOJTAS Stanislaw; POLITECHNIKA GDANSKA; Gdanska, Poland

1987 - A9-3

Estimation of Life expectancy of polyethylene insulated cables

SRINIVAS N. Nagu; Detroit Edison Company; Detroit, USA

BERNSTEIN B.S.; EPRI; Washington DC, USA

1987 - A9-4

Long term ageing phenomena of XLPE cable

KITAI S., ASAI S., HIROTSU Kenichi; SUMITOMOELECTRIC INDUSTRIES; Osaka, Japan

1987 - A9-5

Characterization of the degree of cable ageing by a dual polarity breakdown test method

DIMA A., KATZ Carlos, EAGER Jr. G.S.; CABLE TECHNOLOGY LABS.; New Brunswick, NJ, USA

EATON R.; US DEPARTMENT OF ENERGY; Washington DC, USA

1987 - B1-1

The measurement of internal fields in insulators for high voltage cables - Possibilities opened by the pressure wave propagation method

ALQUIE C., LEWINER J.; ESPCI; Paris, France

1987 - B1-2

Comparative study of the behaviour of two polyethylene types under DC voltage, by the pressure wave method

CHAPEAU F.,DlTCHI T., ALQUIE C., LEWINER J.; ESPCI Laboratoire d'Electricité Générale; Paris, France

PERRET J., DALLE Bernard; EDF-DER/ERMEL; Clamart, France

1987 - B1-3

About a method to measure space charge density inside PE

TOUREILLE Alain; USTL; Laboratoire d'Electricité, MontpeIlier, France.

1987 - B1-4

Influence of conduction on the breakdown mechanism of polyethylene under hydrostatic pressure

HOANG-THE-GIAM, BUI AI, ANTONIU A.; Université Paul Sabatier; LGET, Toulouse, France

GUERIN P. ; LCIE; Fontenay aux Roses, France

PERRET J.; EDF-DER/ERMEL; Clamart, France

1987 - B2-1

Water treeing under DC voltage with polyethylenes for HV DC cables

FILIPPINI J.C., JANTZEN A.; CNRS Laboratoire d'Electrostatique et de Matériaux Diélectriques,; Grenoble, France.

DALLE B., DESCHAMPS L., PERRET J.; EDF-DER/ERMEL; Clamart, France

1987 - B2-2

Extruded synthetic insulations for development of HDVC energy cables

PAYS Michel, LOUIS Michel; EDF-DER/ERMEL; Moret-sur-Loing, France

1987 - B2-3

TOPIST, an innovative HVDC submarine cable

BALOG G.; STK; Okern, Norway

HERBRETEAU A.; TOTAL; Paris la Défense, France

LUONI Giuseppe; CAVI PIRELLI; Milano, Italy

TERRAMORSI G.; TREFICABLE PIRELLI; Saint Maurice, France.

1987 - B3-1

Influence of DC voltage application on dielectric performances of XLPE cables

HARASAWA K., SHIMAMURA Y.; TOKYO ELECTRICPOWER; Tokio, Japan

FUKAGAWA H.; CRIEPI; Yokosuka, Japan

SOMA Ken-Ichiro, MARUMO M.; Hitachi Cable Ltd; Ibaraki, Japan

1987 - B3-2

Cable covering failure detection

BALAN Gheorghe, MÂTHÉ Balazs; ICEMENERG; Bucharest, Rumania

1987 - B3-3

Development of digital cable fault locating instrument

SUZUKI Y., OHI S., ARAKANE M; Chubu Electric Power Co.; Nagoya, Japan

AIHARA M., FUJIWARA Y., SHINAGAWA Junichi; Showa Electric Wire & Cable; Kawasaki, Japan

1987 - B3-4

Scope of echometry for faults location on energy cables

PAYS Michel; EDF-DER/ERMEL; Moret-sur-Loing, France

1987 - B3-5

Thermal control of underground cables - hot spot detection

THEVENON Henri; LES CABLES DE LYON; Calais France.

1987 - B4-1

Power cables electromagnetic and thermal modelling

KLADAS A., PICHON L., RAZEK A.; ECOLE SUPERIEURE D'ELECTRICITE; LGEP, Gif Sur Yvette, France.

1987 - B4-2

Electromagnetic forces and installationmethods for single core cables

KLEVJER Gunnar, LERVIK Jens Kristian; EFI Norwegian Research Institute of Electricity Suppl; Trondheim, Norway

1987 - B4-3

A study on insulation shrinkback in cross-linked polyethylene cables

ASADA Yoshihisa, MARUYAMA Y.; FURUKAWAELECTRIC; Chiba, Japan

1987 - B4-4

The nature and distribution of water in steamcured XLPE cables

PELISSOU Serge, CRINE Jean Pierre, CASTONGUAY Jacques, HARIDOSS S.; IREQ; Varennes Québec, Canada

BOSE Tapan K., MERABET Mustapha; UNIVERSITE DU QUEBEC-Dpt. de Physique; Trois Rivières, Canada

TOBAZEON R.; CNRS/LEMD; Grenoble, France

1987 - B4-5

Experimental difficulties and significance of water-content measurements in cable insulations

GROEGER Joseph H., DAMON Dwighf H.; University of Connecticut Institute of Materials & Science; Storrs, USA

PELISSOU Serge, CRINE Jean Pierre, ST-ONGE Hugues; IREQ; Varennes Québec, Canada

1987 - B4-6

Microscopic failure in water-treeing and fatigue as revealed by transmission electron microscopy

ROSE L.J., ROSE V. ; BP CHEMICALS; Research & Development, Grangemouth, UK.

DE BELLET J.J.; BP CHEMICALS; Meyrin Switzerland

1987 - B4-7

Differential thermal analysis of electric ageing of polyethylene samples in water

GLUCHOWSKI S.; INSTYTUT PODSTAW ELEKTROTECHNIKI I ELEKTROTECHNOLOGII; Wroclaw, Poland

LAURENT C., MAYOUX C.; UNIVERSITE PAUL SABATIER; LGET, Toulouse, France

1987 - B4-8

Optimization of cable crosslinking process on dry curing Lines

SCHIRATO Philippe; BP CHEMICALS SUISSE; Meyrin, Switzerland

FRETIER P.; FILERGIE; Paron Sens, France

1987 - B4-9

Design consideration and thermal stability calculation of shields used in high voltage XLPE insulated power cables

OBRAZTOV Yu.V., SINYAKIN A.F., KHOLOONY S.O.; ALL UNION CABLE RESEARCH INSTITUTE; Moscow, Russia

1987 - B5-1

Water treeing retardant XLPE insulation grade with improved electrical endurance

FARKAS Andras A., SULTAN B-A, AHLSTRANO L-E; NESTE POLYETEN; Stenungsund, Sweden

1987 - B5-2

Development in semiconductive products for medium voltage XLPE power cable

BURNS Norman M. Jr,; Union Carbide Corporation; Somerset, NJ, USA

1987 - B5-3

Fire resistant halogen free materials for electric cables industry - Technical and economical situation

DUPONT, MONJARDET, SAUNIER; FILERGIE; Paron Sens, France

GUERZIO, PELATI, BONINO; CEAT CAVI; Torino, Italy

1987 - B5-4

Investigation on EVA grades for fire resistant halogen free thermoplastic cables

DRUOT Ph.; ATOCHEM; Orthez, France

1987 - B5-5

Water impervious on-jacket moisture barrier cable

GROSSER Brian K., BOW K.E.; DOW CHEMICAL; Granville, OH, USA

SMITH J.; DOW CHEMICAL EUROPE; Horgen, Suisse

NIEUWHOF B.J.; FIRET; Veenendaal, The Netherlands

1987 - B6-1

Taking into account of the overloading capacity of cables in the dimensioning of HV and VHV links

DHAUSSY M.; EDF-DPT/CERT; Paris la Défense, France

DORISON Eric; EDF-DER/ERMEL; Moret-sur-Loing, France

LEPERS J.; EDF-DPT/CRTT; Vitry, France

1987 - B6-2

Fault current rating of metallic cable screens

WHITE LM.; ELECTRICITY COUNCIL; London, UK.

PHILBRICK S.E.; PIRELLI GENERAL; Eastleigh, United Kingdom

HYDE H.B.; EAST MIDLANDS ELECTRICITY BOARD; Nottingham, UK

PRYER D.W.; BICC POWER CABLES; Wrexham, UK

1987 - B6-3

Thrusts and short circuit phenomena in extruded HV cable systems and methods to control the

LEUFKENS P.P., WILLEMS H.J.M.; VAN DER MAAREL P.C.M.; NKF KABEL, Delft, The Netherlands

1987 - B6-4

Recommendations for cables installation taking into account mechanical stress during laying process

GASPARINI Georgio; CEAT CAVI; Torino, Italy

ROY Daniel; FILERGIE; Paron Sens, France

1987 - B7-1

Experiences of mechanized laying for underground cables in rural area

KERN Bernard, HIRTH Bernard; ELECTRICITE DE STRASBOURG; France

1987 - B7-2

275 kV XLPE insulated cables for tunnel and shaft installations

BENNETT Harold Roy; PIRELLI GENERAL; Eastleigh, United Kingdom

GIBBONS J.A.M.; CENTRAL ELECTRICITY RESEARCH LA8S; Leatherhead, Surrey, UK

1987 - B7-3

Thermo-mechanical behaviour of 275 kV XLPE cable in tunnel

WATANABE Y., YAGISAWA K.; TOKYO ELECTRIC POWER; Tokio, Japan

HIYAMA S., NISHINOMA Masachiro; Fujikura Ltd; Tokyo, Japan

1987 - B7-4

Installing 225 kV synthetic insulation cables in very deep shafts

AUCLAIR Henri, BARSACQ M., FAVRIE Eugène; SILEC; Montereau, France

BHEEMAN L.; TAMIL NADU ELECTRICITY BOARD; India.

1987 - B8-1

Materials development for special cables

MURPHY Richard John; PIRELLI GENERAL; Eastleigh, United Kingdom

BERETTA G.; CAVI PIRELLI; Milano, Italy

1987 - B8-2

Cables with aluminium alloy conductor for aeronautic use

BASLY Michel, FERLIER Jean Pierre; FILOTEX; Draveil, France

1987 - B8-3

Extension of the field of the heating electrical cables

DELEAGE Pierre ; DELEAGE; Saint Malo, France

COUPPE Gérard; TREFICABLE PIRELLI; Saint Maurice, France.

1987 - B8-4

Cables for mines : supply of bottom installations by HV cables

BLIGNY Jean, WIEDENKELLER J.G.; SILEC; Montereau, France

1987 - B9-1

Optical fibers in power underground links

DUCHATEAU Francis; EDF-DER/ERMEL; Moret-sur-Loing, France

1987 - B9-2

Submarine power cable incorporating telecommunications data and control links

MARSH Timothy G., BEER L.,J. SHACKLETON D.J.; AEI CABLES; Gravesend, Kent, UK.

1987 - B9-3

Composite power and optical submarine cable

CANTEGRIT B., BAYARD C., TREZEGUET J.P.; LES CABLES DE LYON; Clichy, France.

1987 - B9-4

Submarine composite cables for power and data transmission - Design philosophy

GIUSSANI A., LANFRANCONI G.M., OCCHINI Elio; CAVI PIRELLI; Milano, Italy

1991 - A10-1

ion migration in aged power cable

RICHARDSON Colin G., MATEY G.; BP CHEMICALS; Meyrin, Switzerland

ROSE L.J.,; BP CHEMICALS; Grangemouth, U.K.

FINNEY RW.,; BP Research Centre; Sunbury -U.K.

1991 - A10-2

Discharges in polymers

DANIKAS M.G.; ASEA Brown Boveri; Baden Switzerland.

1991 - A10-3

Study of the kinetic of the degradation of LOCA cable materials. Influence of the radiation dose and of the dose rate

GUEGUEN V., AUDOUIN L.; ENSAM; Paris, France.

PINEL B.; EDF/DER; Clamart, France

SEYTRE G., PHELUT L; CNRS; Lyon, France

1991 - A10-4

Procedure for the ageing studies concerning the polymeric cables

DUCHATEAU Francis & Co-authors; EDF/DER; Clamart, France

1991 - A10-5

Membrane potential technique applied to the study of cable insulation modification

MONDIN Sylvie, AREFI F, AMOUROUX J.; ENSCP; Paris, France

LETELLIER P.; Université Paris 6; France

GOLDMAN M.; ESE; Gif-sur-Yvette, France

FEDOROFF M.,ROUCHAUD J.C.; CECM/CNRS; Vitry, France

LEGUENNEC P.; EDF/DER; Clamart, France

1991 - A10-6

Long-term performance of silicone lubricants used for separable interface electrical connector

GROEGER Joseph H.; University of Connecticut; Storrs, USA

1991 - A1-1

Wet electrical ageing characteristics of various furnace carbon blacks

LEFEBVRE Steven D. , SIFLEET William L.; CABOT Corporation; Corporation Billerica, USA

GROEGER Joseph H.; University of Connecticut; Storrs, USA

TOMME Marcel; CABOT Technical Center; Leiden, The Netherlands

1991 - A11-1

Use of after laying test methods for the evaluation of the ageing of MV cables

BAUTZ R., KRÂHENBÜHL Francis, VELUZATG., WAVRE J. J; Cables Cortaillod; Cortaillod, Switzerland

1991 - A11-2

Characterization of medium voltage cable splices aged in service

LAMARRE Laurent, CHINH DANG; Hydro-Québec; Varennes Québec, Canada

1991 - A11-3

Degradation of LOPE insulation of 15 kV power cables in laboratory and service environment

BORYN H., WASILENKO E., WOJTAS S.; Technical University of Gdansk; Poland.

1991 - A11-4

Remaining properties of PVC cables for power stations. Correlation between chemical and electrical performances

METZGER Gisèle, PAYS Michel; EDF/DER; France

1991 - A1-2

High performance semiconductive compounds testing, production and experience

FARKAS A. Andras, NILSSON U.H., AKERMARK G.; NESTE POLYETEN; Stenungsund, Sweden

1991 - A1-3

Semiconductive plastic coated metallic shielding and armouring materials for power cables

BOW Kenneth E.; Dow Chemical; Granville, OH, USA

BIERINGA L., SMITH John W.,ZUERCHER Karl; Dow Chemical Rheinwerk; Rheinmuenster, Germany

1991 - A1-4

Development of functionalized poly-olefins based thermo-plastic elastomers (TPEs) and composites as Insulating material for medium voltage cables.

Preparation, characterization and Life time prediction by thermo analytical techniques

SANGHI L.K., BHATTACHARYYA AS.,MUKHERJEE B., SEN AK.; Fort Gloster Industries; Howrah, India

1991 - A1-5

An improved medium voltage insulating material for terminations and other medium voltage electrical accessories

GRAEVE B.D., HAVERKAMP W.L., PENNECK R.J., TAMPLIN Paul; Raychem; Ottobrunn, Germany

1991 - A2-1

New MV polymeric insulated power cable (XLPE) design

URTUBI José-Maria, ELEJALDE F.J.; IBERDUERO; Bilbao, Spain

AZPEITIA J.; CABLENOR; Vitoria, Spain

1991 - A2-2

Laboratory investigation of failure of medium voltage XLPE cable joints

RATRA M. C., NAGAMANI H.N.; Central Power Research Institute; Bangalore, India

1991 - A2-3

Compact derivation for LV underground network

MOPTY Yves, DUPONT André; SIMEL; Gevrey Chambertin, France

TARDIF Laurent, REDOLAT Raymond; Cables Pirelli; Saint Maurice, France

1991 - A2-4

Cable terminal and connecting systems. Inner cone system connex

SCHUSTER Martin; PFISTERER; Stuttgart Germany

1991 - A3-1

Development of flat by-pass cable best-suited for on-the-ground installation

FUTAMATSU.K., KUMAZAWA Takao; Chubu Electric Power; Nagoya, Japan

GOTO Y., HIYAMA S.; Hitachi Cable Ltd; Japan

KIDO K., HAGIWARA T.; Furukawa Electric; Japan

1991 - A3-2

Machine-aided cable laying in French MV systems. Latest development

KASZOWSKI Daniel; Alcatel Câble; Clichy, France.

1991 - A3-3

Study of the evaluation of operating reliability of polymeric 20 kV cables

GHITA Teodor, PADENCOV Delia, SANDULaura; MIMUEE, Research Institute for the Electrotechnical Industry; Bucharest, Rumania

1991 - A3-4

A method to estimate the service reliability of XLPE insulated power cables

BENES V.; Power Research Institute; Brno, Czechoslovakia.

1991 - A3-5

Operation behaviour of underground LV and MV cables in Rumanla. Phenomena analysis and specific solutions for underground or underwater MV cables

operation

PISPIRIS C.S.; ICEMENERG; Bucharest, Rumania.

1991 - A4-1

Temporary cable connections for 90 and 63 kV applications using EPDM insulation

MIDOZ Jacques; Cables Pirelli; Charenton-Ie-Pont., France

1991 - A4-2

High voltage cables (86 kV A.C.) insulated with thermoplastic materials

COCIU Alina-Craita; ICPE-Research Institute of Electrotechnical Industry; Bucharest, Rumania.

1991 - A4-3

Thermomechanical behaviour of HV and EHV cables with copper conductors

SCHOONAKKER P.,WILLEMS H.M.J.; NKF KABEL BV; Delft, The Netherlands

1991 - A4-4

Thermomechanical behaviour of XLPE cables under normal and short-circuit conditions

HEAD J.G., CROCKETT A.E.; Pirelli General; Eastleigh, United Kingdom

WILSON A., WILLIAMS D.E.; National Grid; United Kingdom

1991 - A4-5

Design method and analysis for thermo-mechanical behaviour of 275 kV XLPE cables

ISHII K., IWATA Z., INOUE T.; FurukawaElectric; Ichihara- Japan

1991 - A5-1

Development of heat resisting type cable joints for 66-77 kV gas insulated transformers

KASE Toshio, TAKEDA Shouji, NAKADATEMasumi.; Toshiba; Kawasaki, Japan

YOSHIKAWA Hideo, SEMA Nobuyuki.; Showa Electric Wire & Cable; Kawasaki, Japan

1991 - A5-2

Development of prefabricated joints for 154 kV XLPE cable

HAYASHI M.,AKIYAMA T., INOUE T.; TheKansai Electric Power; Osaka, Japan

INOUE H., FUDAMOTO K.; Sumitomo Electric Industries; Osaka, Japan

NAKANO T., GOTOH S.; The Furukawa Electric; Tokyo, Japan

1991 - A5-3

A range of transition joints for 33 kV to 132 kV polymeric cables

ATTWOOD J.R, GREGORY Brian, SVOMA R; BICC CABLES; Erith, United Kingdom

1991 - A5-4

Development of pre-fabricated joints for 275 kV XLPE cables

IMAI N.,ANDOH K.; Mitsubishi Cable Industries; Saitama, Japan

1991 - A5-5

Installation of cables of 130/225 kV specified voltage in case of sub-fluvial crossing

SIN Sylvie; EDF/CERT; Paris, France

FAVRIE Eugène, BARSACQ M.; SILEC; Montereau, France

SAINT-MARTIN; HDI; Cergy-Pontoise, France

LATARGES; SPIE TRINDEL; Cergy-Pontoise, France

1991 - A5-6

Installation of a 230 kV XLPE insulated cable at Ontario Hydr

FOTY S.M., GUPTA B.K., HORROCKS D.J., KUFFEL J.; Ontario Hydra; Toronto, Canada

1991 - A6-1

Longitudinally water resistant cables

MARCIANO-AGOSTINELLI F., CINOUEMANIP.L.; Pirelli-Cable; Lexington, USA

KUCHTA Frank L.; Pirelli Cable; Greenwood, USA.

1991 - A6-2

Resistance to sea water and evaluation of the aggression of the biological sea environment of the insulation and the sheath of energy cable used for

supplying off-shore platforms

NEDEA Mihail Adrian; ICPE- Research Institute for Electrotechnical Industry; Bucharest, Rumania

1991 - A6-3

Longer Life cables by use of tree retardant XLPE Insulation and super-smooth shields

EICHHORN R.M.; Union Carbide Chemicals and Plastics; Somerset, NJ, USA

SCHÀDLlCH H.; Kabelmetal Electro Hannover; Germany

BOONE W.; Kema Laboratories; Arnhem, The Netherlands

1991 - A6-4

Influence of water on synthetically Insulated MV cables and accessories

ROSEVEAR Robert D.; Pirelli General; Eastleigh, United Kingdom

1991 - A6-5

WTR XLPE Insulation. Laboratory and field experience

MATEY Gabriel; BP CHEMICALS; Meyrin Switzerland.

SCHUPPE W.D., BANOWSKI 0.; AEGKABEL; Monchengladbach, Germany

1991 - A7-1

The use of waterswellable materials in the design of power cables

DEBOER R.S., VOGEL P., LANTOR.; Firet Cable Wrappings; Veenendaal, The Netherlands

1991 - A7-2

Water tree meter, an automatic equipment for water treeing measurements in insulation materials for cables

MARTEAU C., FILIPPINI Jean.; CNRS/LEMD; Grenoble, France

1991 - A7-3

Test methods for assessing watertree resistant insulation

NAYBOUR R.D.; Electricity R & D Centre; Capenhurst, United Kingdom

1991 - A7-4

Improved method for evaluation of water treeing properties of semiconductive materials

FARKAS A. Andras, NILSSON U.H.; Neste Polyeten; Stenungsund, Sweden

1991 - A7-5

Model cable test for evaluating the ageing behaviour under water influence of compounds for medium voltage cables

LAND H.G., SCHÀDLlCH Hans.; Kabelmetal Electro; Hannover, Germany

1991 - A7-6

International standardization activities for moisture impervious cables

BOW Kenneth E.; Dow Chemicals; Granville, OH, USA

SNOW Joseph H.; Anixter Bros; Angleton USA

WILKENS, William D.; Anixter Bros; Skokie, IL, USA

1991 - A8-1

The effect of silver ions on the formation of water tree

FAN ZONG HUAI.; Shanghai Electric Cable Research Institute; P.R. China

LIU ZI YU; Xian Jiaotong University; P.R. China.

1991 - A8-2

The influence on water treeing of ion-ion interactions in solution

CRICHTON B.H., HUIMIN LI., FOURACRE RA; CEPE University of Strathclyde; Glasgow , United Kingdom

1991 - A8-3

Ageing phenomena at cable-shield interfaces affecting the propensity of the insulation to develop water trees

MASHIKIAN Matthew S., GROEGER Joseph H.; University of Connecticut; Storrs, USA

1991 - A8-4

Evidence of continuous paths in the structure of water trees

MOREAU E., BOUDET A.; CEMES-LOE/CNRS; Toulouse, France

MAYOUX C., LAURENT C.; Laboratoire de GénieElectrique/CNRS; Toulouse, France

MONTAGNE PH.; ATO-CHEM; Orthez, France

BERDALA Jacques; Câbles Pirelli; Charenton-le-Pont, France

1991 - A8-5

Medium voltage polymeric power cables. Clarification of the cause of water treeing and methods of its prevention

DEJEAN Pierre-Marcel; Câbles Pirelli; Sens, France

BANKS V.AA, GROOMBRIDGE AB.; BICC Cables; Clwyd- United Kingdom

AM. BOTELHO DOREGO; CQFM INIC IST; Lisboa, Portugal

PEDROSO Francisco, J. CELCAT; Pero Pinheiro; Portugal

MARCHESIE JW., GIVEN M.J., FOURACRE RA; University of Strathclyde; Glasgow G1 1XW, UK

LACABANNE C., MAYOUX Christian; Université Paul Sabatier; Toulouse, France

1991 - A9-1

Average molecular weight between crosslinks and water tree growth in crosslinked polyethylene

SHAIKEVITCH A, HARIDOSS S.; AT Plastics; Brampton, Canada

ZHOUO.x., RUDIN A; University of Waterloo; Canada

1991 - A9-2

A study on long-term characteristics of XLPE cables

KATSUTA Ginzo; TEPCO; Tokyo, Japan

1991 - A9-3

The influence of crosslinking on the void formation in XLPE Insulation

SIMUNKOVA O., KOVACOVA 1.; Cables & Insulating Materials Research Institute; Bratislava, Czechoslovakia

1991 - A9-4

A study on size effect in breakdown properties of HV XLPE cables

TANAKA Hideo, ICHIYANAGI N., MARUYAMA Y., TANABE T., IWATA Z.; The Furukawa Electric; Chiba, Japan

1991 - A9-5

Influence of structural changes of XLPE on dielectric properties of cable insulation

KROLIKOWSKI Czeslaw, RAKOWSKA Aleksandra; Technical University of Poznan; Poland

1991 - A9-6

Evaluation of long-term Insulation performance of EHV XLPE cables by a high frequency acceleration test

ISHIDA M., SUZUKI H., OKAMOTOT., FUKAGAWA H.; CRIEPI; Kanagawa-Ken, Japan.

1991 - B10-1

XLPE behaviour under hydrostatic pressure and DC voltage. Tests on materials and full cables

HOANG-THE-GIAM, ESSOLBI R.; Laboratoire de Génie Electrique; Toulouse, France

ROY Daniel; Câbles Pirelli; Charenton-Ie-PontFrance

BALLON F., PAYS M.; EDF/DER; Moret-sur-Loing, France

1991 - B10-2

Development of 10 kV submarine cable with high mechanical strength

Mc CONNELL Jim; Pirelli General; Eastleigh, United Kingdom

1991 - B10-3

Gulongyu Lay 10 kV XLPE Submarine cables

HUANG Shi Sin; Xiamen Power Supply Bureau; Xiamen, PR of China

LI HanSun; Shangai Municipal Electric Power Bureau; Shanghai, P.R. China

PAULIN D.; Alcatel Câble; Calais- France

1991 - B1-1

Detecting the breakdown causes of XLPE cable byPPD method

TANAKA Takeshi; TEPCO; Tokyo, Japan

WATANABE Masaru, YATSUKA Ken; Sumitomo Electric Industries; Osaka, Japan

1991 - B1-2

Advances in Instrumentation for routine partial discharge measurements on HV power cables

HILDER David; Robinson Instrument; Runcorn, United Kingdom

DUFOUR François; Robinson Instruments; Sèvres, France

1991 - B1-3

The development of automatic detecting system for the defects in XLPE insulated cables

IWATA l., SUZUKI H., SHIMADA M., UESUGIK; Furukawa Electric; Chiba, Japan

1991 - B1-4

Development of advanced inspection method for extrusion molded joints

ICHIHARA M. YAMAMOTO M., ISHIHARA H.; Chubu Electric Power; Nagoya, Japan

FUKUI T., WATANABE K., GESSEI., SATO H.; Sumitomo Electric Industries; Osaka, Japan

1991 - B1-5

Electrical treeing tests as a method to characterize insulating materials for cables

BOZZO R., CENTURIONI L.; Universita degli Studi di Genova; Italy

BELLINI V., BRAGAGNI A.; Tratos Cavi; Pieve S. Stefano, Italy.

1991 - B2-1

New technique to detect short circuit current distribution on wire shielding of MV power cables

SENS MA, COSTA Eleilson B., DOSSANTOS P.; CEPEL; Rio de Janeiro, Brasil

TEIXEIRA Mario Daniel Junior, MOCARlEL JA; FICAP; Rio de Janeiro, Brasil

1991 - B2-2

Mechanical short-circuit testing for cable installations

KLEVJER G., LERVIK J.K.; Norwegian Electric Power Research Institute; Trondheim, Norway

TUNHEIM A.; Alcatel Kabel Norge; Olso, Norway.

VOLDHAUG Lars; EBNorsk Kabel; Drammen, Norway

1991 - B2-3

Voltage tests on three-core power cables

WASILENKO E.,WOJTAS S., BORYN H.; Technical University of Gdansk; Poland

1991 - B2-4

Development of synthetic HV cable terminations

LE PEURIAN S.; EDF/DER; Moret-sur-Loing, France

DEJEAN Pierre-Marcel; Cables Pirelli; Sens, France

ARGAUT P.; SILEC; Montereau, France

1991 - B2-5

Electrical testing of aged station cables

BRAUN J.M., GUPTA BK., LLOYD BA,MARRA R.M., SEDDING H.G, STONE G.C.; Ontario Hydro; Toronto, Canada

1991 - B2-6

Average impulse breakdown stress. Interpretation

THEVENON Henri; Alcatel Câble; Lyon, France

1991 - B3-1

Effect of DC testing on aged XLPE insulated cables with splices

SRINIVAS N. Nagu; Detroit Edison Company; Detroit, USA

BERNSTEIN B.S; Electric Power Research Institute; Washington DC, USA

1991 - B3-2

Investigation of alternative after laying tests for MV cables

KALKNER Wilfried, BACH R., PLATH R., ZHIYONG WEI; Technical University of Berlin; Germany

1991 - B3-3

A 50 Hz after laying test for high voltage extruded insulation cables

VERVEEN Arie N.; EWR; Leiden, The Netherlands

PAAP G.C; University of Technology; Delft, TheNetherlands.

1991 - B3-4

Diagnostic medium voltage cable test at 0.1 Hz

STEENNIS Evert Frederik,HETZELE.; KEMA; Arnhem, The Netherlands

VERHOEVEN C.W.J.; PNEM; HA'sHertogenbosch, The Netherlands

1991 - B4-1

Development of low smoke and fume cables and joints for the Channel tunnel

FRIDAY A, ROBERTS D.G., NICHOLLS AW.,; BICC Cables; Wrexham, United Kingdom

1991 - B4-2

Low smoke, non-corrosive fire retardant cable sheaths based on HNBR and EVM

MElSENHElMER Hermann; BAYER; Leverkusen, Germany

1991 - B4-3

LV cables with fire retardant sheath crosslinked at low temperature

AUDOUX Christian; Silec; Montereau, France

1991 - B4-4

Development and qualification of novel cables for LOCA environment

LEE Gun-joo, SOHN Ho-soung, BAE Hunjail, KWON Sung-dae, LEE Bek-young, LEE Chong-kook, PYUN Sun-ho; Gold StarCable; Seoul, Korea

1991 - B4-5

Low voltage PVC building wire and cables with improved flame resistance and with reduced emission of smoke

GARZA, Luis S., VIRKUS Jüri, FLORES Daniel; Conductores Monterrey; México

1991 - B5-1

The fire behaviour of electric cables, testing techniques : present situation and future trends in Italy

PIGINI A., VERCELLOTTI U.; CESI; Milano, Italy

FARNETI F. et al.; ENEL; Milano, Italy

1991 - B5-2

Fire resistant cables. Performance and test method developments

JOURNEAUX Terence L.; Pirelli General; Eastleigh, United Kingdom

1991 - B5-3

Protecting cables from Insect attack

FIELD A.W.; BICC Cables; Wrexham, United Kingdom

PHILBRICK S.E.; Pirelli General; Eastleigh United, Kingdom.

1991 - B6-1

Modelling of power transmission cables

ARGAUT P.; SILEC; Montereau, France

DORISON Eric; EDF/DER; Moret-sur-Loing, France

KARIMI C., ACHARD J.C., BLANCHET F., GERMAIN J., THIEBAUT E.; ESE; Gif-sur-Yvette, France

1991 - B6-2

A fine modelling of cables in harmonic or transient cases by inverse Laplace transform

JOHANNET P.; EDF/DER; Clamart, France

1991 - B6-3

Distribution and Influence of the zero-sequence short-circuit currents in the ground

DORISON Eric; EDF/DER; Moret-sur-Loing, France

1991 - B6-4

Thermal modelling of underground cables under transient conditions

PICHON Lionel, RAZEK A.; CNRS/LGEP/ESE; Gif-sur-Yvette, France

1991 - B6-5

Thermal conditions of cables in soil under layer with another thermal resistivity

SLANINKA Pavel; Slovak Technical University; Bratislava, Czechoslovakla.

1991 - B7-1

Calculation of the heat rate of cables for power transmission

ARGAUT P.; Silec; Montereau, France

PROTAT F., BOUVERETA-, MATHIEUN.,NGUYEN V.; ESE; Gif-sur-Yvette, France

1991 - B7-2

A user-friendly computer program for economic selection of cable sizes.

ANDERSG.J., VAINBERG Mark, HORROCKSD.J., HUGHES AR., FOTY S.M., MOTLIS J.; Ontario Hydra; Toronto, Canada

1991 - B7-3

Economic optimization of the conductor cross-section of power cables according IEC 20 A (CO) 131.A simplified method.

KASZOWSKI Daniel; Alcatel Câble; Clichy France

MIREBEAU Pierre; Câbles Pirelli; Saint-Maurice France

1991 - B7-4

Optimization criteria of the transmission capacity of HV and VHV cables.

DORISON Eric; EDF/DER; Moret-sur-Loing, France

LEPERS J.; EDF/CRTT; Paris, France

RIOT B.; Electricité de France-CERT.; Paris, France

1991 - B7-5

A study on the continuous permissible current rating in 22.9 kV CN/CV underground distribution power cables.

KOOJ.Y., KIM J.T., KIM J.B.; Hanyang-University; Seoul, Korea

1991 - B8-1

Measurement of space charge distribution in cable insulation using the pulsed electroacoustlc method.

FUKUNAGA K., MIYATA H., TAKAHASHI T., YOSHIDA S., NIWA T.; Fujikura Ltd; Tokyo, Japan

1991 - B8-2

Thermal wave method for evaluating the space charge in insulants : validation and application to various materials for HV cables.

TOUREILLE Alain, ABOU DAKKA M., SABIR A., CHERIFI A; LEM, USTL; Montpellier, France

1991 - B8-3

Direct measurement of space charge in synthetic cables by the pressure wave method

MAHDAVI S., ALOUIE C., LEWINER J.; ESPCI; Paris, France

1991 - B8-4

Comparison between the space charge distribution and the DC breakdown voltage of synthetic insulation.

BEZILLE J., BECKER J., JANAH H.; Alcatel Câble; France

PRIGENT M., PONS J.; Alcatel Alsthom Recherche; France

1991 - B8-5

Influence of the pressure on the space charge included in the cable insulations.

GARROS B., HOANG-THE-GIAM, BUIAI,; CNRS/LGET; Toulouse, France

TOUREILLE Alain; Laboratoire d'Electrotechnique, Université des Sciences et Techniques du Languedoc; Montpellier, France

ROY Daniel, BERDALA Jacques; Câbles Pirelli; Charenton-le-Pont, France

1991 - B8-6

Space charge under DC voltage, incidence on the after laying test of the VHV cable links.

ALOUIE C.; ESPCI; Paris, France

ARGAUT P.; Silec; Montereau, France

1991 - B9-1

Development of new materials for HVDC polymeric insulated cables.

KHALIL M. Salah; Danish Electrical Research Institute; Lyngby, Danemark

PROCIDA I.M., LOVSTROM SORENSEN P.; NKT Power Cables; Denmark

1991 - B9-2

Development of DC ± 250 kV XLPE cables and factory joints

MAEKAWA Y., YAMAGUCHI A.; Electric Power Development; Tokyo- Japan

YOSHIDA S.,WATANABE K., YAMANOUCHI H.,YOKOYAMA S.; Fujikura Ltd; Tokyo- Japan

1991 - B9-3

Research and development of DC XLPE cables

MAEKAWA Y., YAMAGUCHI A.; Electric Power Development; Tokyo, Japan

IKEDA C., SEKII Yasuo, HARAM.; Hitachi Cable Ltd; Hitachi, Japan

1991 - B9-5

Short time breakdown and life duration under DC voltage and pressure of HDPE

BENLIZIDIA F., FARKH M., HOANG-THE-GIAM, BUI-AI; CNRS/LGET; Toulouse, France

DALLE Bernard, DUCHATEAU F.; EDF/DER; Clamart, France

ROY Daniel, BERDALA Jacques; Câbles Pirelli; Charenton-le-Pont, France

1995 - A1-1

Recent developments in 400 and 500 kV XLPE cables

ARGAUT P., FAVRIE E.,; Silec; Montereau, France

1995 - A1-2

Extension of XLPE cables to 500 kV based on progress in technology

PESCHKE E., SCHROTH R., OLSHAUSEN R.; SIEMENS AG.; Berlin, Germany

1995 - A1-3

Prequalification test of 400 kV XLPE cable systems

HELLING K., HENNINGSEN CG.,POLSTER K.; BEWAG; Berlin, Germany

BOSOTTI O., MOSCA W., TELLARINI; CESI; Milano, Italy

1995 - A1-4

Development of an XLPE insulated cable system for 400 kV operations

ROSEVEAR Robert D., LARRIVE C.; Pirelli Cables; Eastleigh, United Kingdom

PARMIGIANI Bruno; Pirelli Cavi; Milano, Italy

DEJEAN Pierre-Marcel; Câbles Pirelli; Sens, France

1995 - A1-5

550 kV cables laid in tunnel for the Guangzhou pumping station

PAULIN D., LEGUE JL., VASSEUR E., COUQUET JM.; Alcatel Câble; Clichy / Calais, France

1995 - A1-6

A new generation of HV and EHV extruded cable systems

WILLEMS H., GEENE H., VERMEULEN M.; NKF Kabel; Delft, Pays Bas

1995 - A2-1

Mechanized laying of HV cables

DURAND P.; EDF/DEPT-CERT; Paris la Défense, France

LE PEURIAN S.; EDF/DER-ERMEL; Moret-sur-Loing, France

1995 - A2-2

Fluidized thermal backfill for increased ampacity of underground power cables

PARMAR D., RADHAKRISHNA H.S., STEINMANIS J.E.,; Geotherm Inc.,; Ontario, Canada

1995 - A2-3

Experience in on-line relaxation of XLPE insulated high voltage cables

KOUTI T.; Nokia Cables; Pikkala, Finland

KARPPOJ., HUOTARI P., HONGISTOA.,; Nokia-Maillefer; Vantaa, Finland

1995 - A2-4

Development and qualification of a submarine 90 kV cable system using extruded insulation for the electric supply of Guernsey island

LE PEURIAN S.; EDF/DER; Moret-sur-Loing, France

SIN Sylvie, DURAND P.; EDF/CERT; Paris, France

AUCLAIR H.; SILEC; Montereau, France

1995 - A2-5

Mechanical rating of single core cables in trefoil

KLEVJER G., KULBOTTEN H., LERVIK J.K.; EFI; Trondheim, Norway

1995 - A2-6

Remote monitoring and simulation of 138 kV underground power pipe type cable forced cooling system

NAMKUNG S.; Commonwealth Edison; Chicago, USA

1995 - A3-1

Dry terminations : applicability to EHV

ARGAUT P., LUTON M-H.; Silec; Montereau, France

1995 - A3-2

Composite EHV terminations for extruded cables

ARGAUT P., LUTON M-H.; Silec; Montereau, France

1995 - A3-3

Use of elastomeric material for manufacturing of HV and EHV accessories

SCHMID M., LAURENTM., GAILLE F.; Câbleries et Tréfileries de Cossonay; Cossonay, Switzerland

1995 - A3-4

Development of short term use repair joint for 275 kV XLPE insulated cable

TOYA A., KATSUTA G.; The TokyoElectric Power Co.; Tokyo, Japan

NAKANO T., ADACHI K.; The FurukawaElectric Co.; Tokyo, Japan

SHIIBA Y., NAKANISHI T.; SumitomoElectric Industries; Osaka, Japan

1995 - A3-5

Application of prefabricated joints to 154 kV XLPE cables in Korean power transmission system

CHOI C.S., KIM Y.; Taihan Electric WireCo.; Korea

KOOJ.; HanYang University; Kyungki,Korea

CHOI J.-H.; Korea Electric Power Corporation (KEPCO); Korea

HWANGS.C., GO C.S.,; LG Cable and Machinery Ltd,; Korea

1995 - A4-1

Development of a jointing machine for XLPE cables

MAYAMA S., MIZUTANI Y.,INOUEH., FUKUNAGA S.; Sumitomo Electric Ind.,; Osaka, Japan

1995 - A4-2

Prefabricated accessories for high voltage cables design, dimensioning and field experience

ONODI T.,; DATWYLER Ltd.,; Altdorf, Switzerland

1995 - A4-3

Outdoor and incorporated terminations for extruded synthetic cables up to 400 kV

GAHUNGU François; Alcatel Cable; Calais, France

DELCOUSTAL JM.,; GEC Alsthom; Aix-Ies-Bains, France

BROUET J.,; Alcatel Contracting; Clichy, France

1995 - A4-4

Development of HV and EHV single piece premoulded joint

VASSEUR E.,; Alcatel Câble; Calais, France

CHATTERJEE Shotu; Alcatel Euromold; Belgium

1995 - A4-5

Failure series analysis of wrap type cable joints on a 110 kV XLPE cable system

MENNEL H.,; VKW; Bregenz, Austria

1995 - A5-1

From gas insulated switch· gear to cross-country cables

KOCH H.; Siemens; Erlangen, Germany

COUSIN V.; GTMH; France

1995 - A5-2

420 kV three-phase compressed nitrogen insulated cable

THURIES E., PHAM V.D., ROUSSEL P., GUILLEN; GEC ALSTHOM T&D; Villeurbanne, France

1995 - A5-3

Coordination of three· phase gas insulated line (TPGIL) insulation with levels of affecting overvoltages and characteristics of ZnO arresters

KADOMSKAYA K.P., NABOKOV S.-L., VOITOVITCH RA.; Novosibirsk StateTechnical University; Novosibirsk, Russia

1995 - A5-4

Gas insulated cables : from the state of the art to feasibility for 400 kV transmission lines

AUCOURT C., BOISSEAU C., FELDMANN D.; EDF/DER; Moret-sur-Loing, France

1995 - A6-1

Effect of DC testing on XLPE insulated cables

SRINIVAS N. Nagu; Detroit Edison Company; Detroit, USA

BERNSTEIN B.S.,; EPRI; Washington DC, USA

1995 - A6-2

DC Testing of XLPE insulation

PARPAL J.L., GUDDEMI C., AMYOT N., DAVID E.; IREQ; Varennes Québec, Canada

1995 - A6-3

Study On detection for the defects of XLPE cable links

KOBAYASHI S., UCHIDAK, KAWASHIMA T.; Chubu Electric Power; Nagoya, Japan

HIROTSU K., INOUE H.; SumitomoElectric Industries; Osaka, Japan

TANAKA H., SAKUMA S.; The Furukawa Electric Co.; Tokyo, Japan

1995 - A6-4

An optical technique for insitu measurement of the concentration of the crosslinking by products in XLPE cables

BAMJI S.S., BULINSKI A.T.; NationalResearch Council of Canada; Ottawa, Canada

1995 - A6-5

Recommended after Laying test methods for HV XLPE Cable Line

KARASAKI T., TOYA A.; Tokyo ElectricCo.; Tokyo, Japan

JINNO M., ASARI K.; Kansai Electric Co.; Osaka, Japan

MIYATA E., SHIMOHIRO D.; Chubu Electric; Nagoya, Japan

YOSHIDA T.; Furukawa Electric Co; Tokyo,Japan

KAKUTA M.,; Mitsubishi Cable Ind. Ltd; Kumagaya, Japan

KOJIMA T.,; Furukura Ltd; Japan

1995 - A7-1

Some factors for the space charge formation of polyethylene

TAKAHASHI T., MIYATA H., NAKATUKA T., YOKYOYAMA A.; Fujikura Ltd; Tokyo, Japan

1995 - A7-2

Space charge distribution in single water-trees measured by laser-induced pressure pulse method

RENGEL U.,; Brugg Kabel; Brugg, Switzerland

1995 - A7-3

Study of the origin of space charge created during preparation of polyethylene plaques

VELLA N., TOUREILLE Alain; Laboratoire d'Electrotechnique de Montpellier; Montpellier, France

NILSSON U.H.; BOREALIS Polyeten; Stenunqsund, Sweden

1995 - A7-4

Space charge measurement in XLPE cable with 9 mm thick insulation

HOZUMI N., TAKEDA T., SUZUKI H., OKAMOTO T.; CRIEPI; Kanagawa, Japan

WATANABE Kazuo, WATANABE Akitoshi, MIYATA H.; Fujikura Ltd; Chiba, Japan

1995 - A7-5

Study of the electrode insulator interfaces by simultaneous measurement of external current and of space charge distributions

MORIN P., ALQUIÉ C., LEWINER J.,; ESPCI; Paris, France

1995 - A7-6

Measurement of space charge distributions under 50 Hz AC stress

BERT C., HENNION C.; HLP; Paris, France

LEWINER J., ALQUIÉ C.; ESCPI; Paris, France

HAMPTON N.; BICC Cables Ltd; Erith, UK

FREESTONE J.; BICC Cables; Clwyd, UK

VERNE S.; BICC plc; Herts, UK

1995 - A8-1

Oxidation and its effect on charge trapping in low density polyethylene

CARTWRIGHT GA, DAVIES A.E.; University of Southampton; Southampton, U.K.

SWINGLER S.G.; National Grid Co.; United Kingdom

1995 - A8-2

Influence of aging over the morphology of XLPE

ROBERTSON Ch.; Ecole Polytechnique de Montréal; Canada

FOURNIER D., LAMARRE L.; IREQ; Varennes Québec, Canada

1995 - A8-3

Electrical breakdown strength evolution of HV XLPE cable after long-term test. Correlation with physical properties

BEZILLE J., BECKER J., JANAH H.; Alcatel Câble; Calais, France

CHAN J., HARTLEY M.; Alcatel CanadaWire; Toronto, Canada

1995 - A8-4

Study on deterioration mechanism of XLPE cables

KAMINAGA K., YOSHIFUJI N.,; The TokyoElectric Power Co.; Yokohama, JAPAN

UOZUMI T., YORITA J., FUKUNAGA S.; Sumitomo Electric Ind.; Osaka, Japan

1995 - A8-5

Influence of temperature on accelerated aging of XLPE and EPR insulated cables under wet conditions

BERNSTEIN B.S., SAMM R.W.; Electric Power Research Institute; Palo Alto, CA, USA

1995 - A9-1

Performances of XLPE under high voltages stress

FOURMIGUÉ JM., VERDIEREN., DELOOF A,; EDF/DER; Moret-sur-Loing, France

BERDALA Jacques, DEJEAN Pierre-Marcel; Câbles PIRELLI; Sens, France

1995 - A9-2

Electrical treeing in mechanically stressed polyethylene

DAVID E., PARPAL JL., CRINE JP.,; IREQ; Varennes Québec, Canada

1995 - A9-3

Electroluminescence on XLPE

MATSUMOTOT., SUZUKI H.,MATSUKI M.,; Furukawa Electric Co.,; Chiba, Japan

BAMJI S.S., BULINSKI T.,; NATIONAL RESEARCH COUNCIL; Ottawa, Canada

1995 - A9-4

Thermal and electromechanical effects on dielectric strength of high density polyethylene under D.C. electrical field

HOANG THE GIAM, ESSOLBI R., ZEBOUCHI N., MALEC D., BUI AI.; Univ. P.Sabatier; Toulouse, France

1995 - A9-5

Qualification and life duration determination of thin sheeted extruded material under high electrical field

FOULON-BELKACEMI N., GOLDMAN M., GOLDMAN A.; CNRS/SUPELEC; Gif-sur-Yvette, France

GATELLET J.; Merlin Gerin; Grenoble, France

1995 - B10-1

Non-destructive control applied on power station cables : Assessment of the residual mechanical properties of cables

BERTRAND Y., PINEL B., BRINCOURT T.; EDF/DER; Moret-sur-Loing, France

1995 - B10-2

Cable fault prevention using dielectric enhancement technology

MOKRY S.; CPS; San Antonio, USA

CHATTERTON W.; Dow Corning Corporation; Auburn, USA

CARTER S.; Duke Power Company; Charlotte, USA

SIBBALD P.; EDON; Groningen, The Netherlands

CLEMMER J.; OG&E Electrical Services; Oklahoma City, USA

BERTINI G.,; UtilX Corporation; Kent, WA, USA

GEORGE P.,; Virginia Power Company; Richmond, USA

1995 - B10-3

Diagnosing power cable polyethylene insulation by electroluminescence monitoring

MARY D., LAURENT C., MAYOUX C.; Université Paul Sabatier; Toulouse, France

BERDALA Jacques; Câbles Pirelli; Paron, France

CLAVREUL R.,; EDF/DER; Moret-sur-Loing, France

1995 - B10-4

Plasma-induced surface luminescence as a tool for high voltage synthetic insulation characterisation

MARY D., MASSINES F.,LAURENTC., MAYOUXC.,; Université Paul Sabatier; Toulouse, France

JANAH H., BEZILLE J.; Alcatel Cable; Calais, France

1995 - B10-5

Thermal ageing monitoring of LOCA cables

CHAILAN JF., BOITEUX G., CHAUCHARD J., SEYTRE G.; Université C. Bernard,; Villeurbanne, France

PINEL B.; EDF/DER; Moret-sur-Loing, France

1995 - B10-6

Insulation diagnosis of XLPE cables by expert system using fuzzy interference

CHOI Y.C., KUBOTA H., OHYAMAR.I.; Tokai University; Kanagawa, Japan

KANEKO K.; Kyushu Tokai University; Kumamoto, Japan

LEE J.B.; Wonkwang University; Iri, Korea

1995 - B1-1

Laminated sheathed cable for replacement of lead sheathed cable in medium voltage applications

SMITH J., BOW K.; The Dow Chemical Co.; Granville, OH, USA

1995 - B1-2

Chemical and moisture resistant medium and low voltage cables

VOLTZ D., BOW K.; The Dow Chemical Co.,; Granville, OH, USA

1995 - B1-3

Development of dry-type transition joints for 22 kV CV cable and SL cable

YOKOSUKA K., YOKOYAMA T.,; Tokyo Electric Power Co.; Tokio, Japan

SAKURAI H., KASHIMOTO M., TAGO M.; The Furukawa Electric Co.,; Hiratsuka,Japan

1995 - B1-4

Development of underground MV network : cable environment and new electrical equipment for rural networks

BONIFACE P., BRINCOURT T., PRUNIERE J-Y.; EDF; France

1995 - B1-5

Technical and economical evaluation of different cable design for 1 kV distribution cables in Spain

MONJO J.,; UNESA; Spain

MONTEYS J., SARRO J., AZPEITIA J.; FACEL; Barcelona, Spain

1995 - B1-6

First field experience and evolution of cold shrinkable MV joints

LEQUEUX Jean-Michel; Câbles Pirelli; Marne-la-Vallée, France

PARMIGIANI Bruno, VALLAURI U.; Pirelli Cavi; Milano, Italy

1995 - B2-1

Development of new 12/20 kV protected aerial lines

DELAUNOIS G.; Câbleries de Lens; Noyelles, France

BACNUS R.; EDFGDF Services; Merignac, France

1995 - B2-2

Covered and insulated cables for overhead distribution

TARALLI C., GODINHO C.A.F., CUNHA AP.; Pirelli; Sao-Paulo, Brazil

1995 - B2-3

European and North American MV EPR power cable comparisons

DEL CORSO D.; BICC CEAT CAVI; Settimo, Italy

FLENNIKEN C.L.; BICC Cables; Indianapolis, USA

VERNE S.,; BICC; Londres, U.K.

1995 - B2-4

Design and installation of 22 kV power cables, for LUL

JOURNEAUX Terence L.; Pirelli Cables; Eastleigh, United Kingdom

FIELD C.J.; London Underground; London, U.K.

CORBELLINI F.; Pirelli Construction; Eastleigh, United Kingdom

1995 - B2-5

PE and XLPE .médium voltage cables- Service experience and examination of insulation state

RAKOWSKA Alexandra; TU of Poznan; Poznan, Poland

1995 - B2-6

Developments in MV accessories

CROUZET G., CHARLES F.; Silec; Montereau, France

1995 - B3-1

The effect of preconditioning on the performance of MV-XLPE cables in long term water treeing tests

BENJAMINSEN J.T., FAREMOH.; EFI; Norway

OLSEN J.A.; EnFO; Norway

MIKKELSEN N.P.; EiselskabetBHHH; Danemark

OLSSON L.; Goteborg Energi AB; Sweden

1995 - B3-2

Electrical long-term test in Germany

KOBER H.; Felten & Guilleaume Energietechnik AG; Kain, Germany

1995 - B3-3

An accelerated ageing test on the basis of 500 Hz for water treeing in cables

BANKS V.A.A.; BICC Cables; Wrexham, UK

FAREMO H.; Norwegian ElectricPowerResearch Inst.; Trondheim, Norway

STEENNIS Evert Frederik; KEMA; Arnhem, The Netherlands

1995 - B3-4

Comparative long-term testing on 20 kV XLPE cables

SCHÂDLlCH H.; Alcatel Kabel; Hannover, Germany

1995 - B3-5

Long duration immersion tests of cross-linked polyethylene insulated MV cables

AUDOUX C.; Silec; Montereau, France

FONDEUR Jean-Hubert; Câbles Pirelli; France

LEROY JH.,PINET A.; EDF; France

SIMEON Eric; Alcatel Cable; France

1995 - B3-6

The behaviour of dry insulation medium voltage cables in a moist environment

URTUBI JM., REOLID G.; Iberdrola; Bilbao, Spain

SARDA J.; Asinel; Madrid, Spain

VALLS F.; Câbles Pirelli; Barcelona, Spain

1995 - B4-1

Material development for the new cold shrink technology

CHÉENNE-ASTORINO A., CHATTERJEE Shotu., DE SCHRIJVER I.; Euromold; Erembodegem, Belgium

MIREBEAU Pierre, ALADENIZE B.; Alcatel Alsthom Recherche; Marcoussis, France

1995 - B4-2

Materials for cables based on polymeric conductors

ALADENIZE B., ASSIERJC., GALAJ S.; Alcatel Alsthom Recherche; Marcoussis, France

MIREBEAU Pierre, JANAH H.; Alcatel Câble; Calais, France

1995 - B4-3

Parameters influencing the strippability of conductive compounds for insulation shields

FAGRELL O.; Borealis; Stenungsund, Sweden

1995 - B4-4

Peel test for semiconductive shields

CHINH.H., WHITEHOUSE R.S.; Cabot Corp.; Billerica, USA

1995 - B4-5

New Polyolefin polymers for low and medium voltage power cables

HEMPHILL J.; Dow Chemical Co.,; Freeport, USA

FANICHET L, LANDUCCI D.; Dow Europe; Horgen, Switzerland

1995 - B5-1

Crosslinking mechanisms in low density polyethylene

GUSTAFSSON B.; Borealis Polyeten; Stenungsund, Sweden

SMEDBERG A, HJERTBERG T.; Chalmers TU; Goteborg, Sweden

1995 - B5-2

Correlation between residual mechanical stresses and properties of XLPE insulated cables

CAMPUS A, DRUOT P.; Borealis; Anvers, Belgium

LENNARTSON H.; Borealis; Stenungsund, Sweden

1995 - B5-3

New insulating materials for HV cables

JANAH H., MIREBEAU Pierre; Alcatel Cable; Calais, France

GADESSAUD R, BARRAUD J:-Y., TRAN P.; Alcatel Alsthom Recherche; Marcoussis, France

BALOG G., PEDERSEN JR; Alcatel Kabel Norge; Halden, Norway

1995 - B5-4

The utilization of crosslinked plastic materials by means of the nuclear radiations in the construction of the cables

GAVRILA D.E.; University Politehnica; Bucarest, Romania

1995 - B5-5

Advantages of hot melt adhesives for overlap bonding and sealing in power cables

BUTTERBACH R.; Henkel KGaA; Düsseldorf, Germany

HEUCHER R.; HENKEL Corp.; La Grange, USA

1995 - B6-1

Simple monitoring method of underground cables

PISPIRIS C.S.; ICEMENERG; Bucarest, Romania

1995 - B6-2

Electric field measurements on MV and HV components with an electro-optic sensor

MAILAND M., ZAENGL W.; ETH Zürich; Zürich, Switzerland

AUMEIER W.; Raychem; Munich, Germany

1995 - B6-3

Behaviour of electric cables under fire conditions

FAVRIE C., BILES O.,; Silec; Montereau, France

1995 - B6-4

A critical assessment of IEC 332-3 (1992), the Italian standard CEl 20-22 (1987) and the requirements of EEC construction products directive from the fire

propagation point of view

FARNETI F.; ENEL; Milano, Italy

VERCELLOTTI U.; CESI; Milano, Italy

1995 - B7-1

Fire risk analysis on MV cable networks : the behaviour of joints in case of fault

FARA A., MIOLA G.; ENEL; Rome, Italy

VERCELLOTTI U.; CESI; Milano, Italy

1995 - B7-2

Characterisation techniques of non-ceramic outdoor insulation, application to cable terminations

FOURMIGUÉ JM., NOEL M., RIQUEL G., LE PEURIAN S.; EDF/DER; Moret-sur-Loing, France

1995 - B7-3

Electrical properties & recommended test methods for HV XLPE cable and accessory

KARASAKI T., TOYA A.; Tokyo Electric Co.; Tokyo, Japan

JINNO M., ASARI K.; Kansai Electric Co.; Osaka, Japan

MIYATA E., SHIMOHIRO D.; Chubu Electric; Nagoya, Japan

WATANABE M., FUDAMOTOK.; Sumitomo Electric Ind.; Osaka, Japan

OSOZAWA K., WATANABE Y.; Hitachi Cable Ltd; Hitachi, Japan

KIHARA T., SAKAGUCHI Y.; Showa Electric Wire & Cable; Kawasaki, Japan

1995 - B7-4

New design of UHV water graded cable test terminations

MOHAUPT Peter, GLEYVOD R.; Haefely Trench; Basel, Switzerland

1995 - B8-1

A review of electrical accelerated ageing data for extruded dielectric cables

PARPAL J.L., DANG C., CRINE JP.; IREQ; Varennes Québec, Canada

1995 - B8-2

Characteristics of field aged medium-voltage cables

PELISSOU Serge; IREQ; Varennes Québec, Canada

1995 - B8-3

Assessment of cable condition by propagation characteristics spectroscopy (PCS)

MASHIKIAN Matthew S., FOSTER S.,; University of Connecticut; Connecticut, USA

1995 - B8-4

Investigations of accelerated ageing of XLPE insulated HV cables under conditions of long-term tests and actual use

VASILIEV N., MAVRIN M., OBRAZTSOV Y., OVSIENKO V,. SHUVALOV M.,; VNIIKP; Moscow, Russia

1995 - B8-5

Development of service life prediction methods for oil-filled cables

POPKOV V.I., PRIVALOV I.N., SHATALIN GA.; HVDC Power Transmission Research Institute; St Petersburg, Russia

1995 - B8-6

Diagnostic field testing of paper-insulated lead-covered MV cable

HETZEL E.; KEMA; Arnhem, The Netherlands

Mac KINLAY R.; EATL; Capenhurst, U.K.

1995 - B9-1

The limits of an ageing study on polyethylene material

DUCHATEAU Francis & Co-authors; EDF/DER/ERMEL; Moret-sur-Loing, France

1995 - B9-2

Optimization of physical and chemical procedures for the study of polyethylene ageing, insulation for power cables

DUCHATEAU Francis & Co-authors; EDF/DER/ERMEL; Moret-sur-Loing, France

1995 - B9-3

Examination and diagnostics of service aged 11 kV XLPE insulated cables

NAYBOUR R.D., ROBINSON G.; EA Technology; Capenhurst, U.K.

1995 - B9-4

Investigation of XLPE insulations after high stress ageing

SCHÂDLlCH H., KLASSJ.; Alcatel Kabel; Hannover, Germany

1995 - B9-5

Dissipation factor of accelerated aged XLPE power cables

NILSSON U.H.; BOREALIS Polyeten; Stenungsund, Sweden

MARSDEN E.; Borealis Compounds Inc.,; Port Murray, USA.

FAREMO H.; EFI; Trondheim, Norway

1995 - B9-6

Diagnostic techniques for service-aged XLPE insulated medium voltage cables

KUSCHEL M., PLATH R., STEPPUTAT L, KALKNER W.; TU of Berlin; Germany

1995 - C

Radial and angular study of XLPE in HV cables by the thermal step method

CASTELLON J., MALRIEU S.; LEM; Montpellier, France

1995 - D1-1

Processing of high smoothness furnace blacks for semiconducting shields

GREENE S.;Cabot Corp.,; Billerica, USA

RICHARDSON Colin G., GRUETTER H.; BUSS; Basel, Switzerland

1995 - D1-2

Design for an electric cable for coal cutting machine 5 kV

MUSQUIN M.; Silec; Montereau, France

SALZMANN H.; HBL; Merlebach, France

1995 - D1-3

Cables for nuclear power stations

JOURNEAUX Terence L.; Pirelli Cables; Eastleigh, United Kingdom

1995 - D1-4

Insulation of high temperature cables for car applications

BENARD Laurent, COLOMBIER Serge, GALCERA Thierry; Câbles Pirelli; Sens, France

LEPATEY M.; Sté Française des Plastiques; Angy, France

1995 - D1-5

Cable for provisional supply transformer integrated in tow

DEMAYJ-N., CARRIERE R,; Alcatel Câble; Lyon, France

1995 - D1-6

Development of halogen free flame-retardant cables for nuclear power plants

AIDA F., YOSHIDA, MINAMI M., NAKAYAK., TAMUKAI K.; Showa Electric Wire & Cable; Kawasaki, Japan

1995 - D2-1

Pulling forces of 25 . kV distribution cables layed in conduits

ORDANESCU M., TARNOWSKI J., NOURRY J.; IREQ; Varennes Québec, Canada

1995 - D2-10

Optimization of the insertion of insulated HV and EHV cables in overhead lines

DORISON Eric, FANG R.; EDF/DER; Moret-sur-Loing, France

1995 - D2-11

Thermal performance of underground power cables with constant and cyclic currents in presence of moisture migration in the surrounding soil

FREITAS D., PRATA A.; Federal University of Santa Catarina; Florianopolis, Brazil

DE LIMA A.; Pirelli SA.; Santo André, Brazil

1995 - D2-12

Forecasting & probabilistic rating of underground power cables

BLACKWELL A, DAVIES A.; University of Southampton; Southampton, UK

LARSEN S.T.; The National Grid Co.; UK

1995 - D2-13

Optimization of expansion loops of 120 kV XLPE cables

TARNOWSKI J., IORDANESCU M., HARDY C., NOURRY J.; IREQ; Varennes Québec, Canada

1995 - D2-14

Study of electric field in critical zones of HV cables by 3D finite elements methods

MORALES N., FERNANDEZ J., ASENJO E., VALDENEGRO A.; University of Chile; Santiago, Chile

1995 - D2-15

A practical model for the lifetime prediction of LOCA (EPDM. CSPE) and (PVC) cables in nuclear power stations

PINEL B., BOUTAUD F.; EDF/DER; Moret-sur-Loing, France

1995 - D2-16

Plasticizers diffusion kinetic for PVC cables : correlation between electrical properties and plasticizers migration

BENHABILES K., PINEL B.; EDF/DER; Moret-sur-Loing, France

1995 - D2-2

On the field distribution in a coaxial DC power cable

COELHO R.,; Alcatel Alsthom Recherche; Marcoussis, France

MIREBEAU Pierre; Alcatel Câble; Calais, France

1995 - D2-3

Thermal analysis of high voltage cables with XLPE insulation based on non-linear thermal characteristics of materials

LARINA E.T., OVSIENKO V., SHUVALOV; VNIIKP; Moscow, Russia

1995 - D2-4

Evaluation and optimization of transmission capacities of power link

ARGAUT P., LESUR F.,; Silec; Montereau, France

1995 - D2-5

Full-scale study of thermal behaviour of MV tri-polar cables laid in conduits

DARDEL B., VELUZAT G., KRÂHENBÜHL F.; Câbles Cortaillod; Cortaillod, Switzerland

1995 - D2-6

Determination of the internal thermal resistivity of a three-core insulated paper cable

BRINCOURT T., LEROY J-H.; EDF/DER; Moret-sur-Loing, France

1995 - D2-7

Magnetic field modelling and management for transmission underground cables

FARAG A.S., AL-SHEHRI A.M., BAKHASHWAIN J.; King Fahd Univ. Of Petroleum & MineraIs; Dhahran, Saudi Arabia

CHENG T.C., ZHENG G., CURCI V., GHAEMI M., KHAJAVI M.; University of Southern California; Los Angeles, USA

1995 - D2-8

Rating of cables on riser poles

ANDERS G.; Ontario Hydro Technologies; Toronto, Canada

1995 - D2-9

Investigations on breakdown strength of polyethylene at very fast transients

GARROS B.; Alcatel Alsthom Recherche; Marcoussis, France

LAND H.G.; Alcatel Kabel; Hannover, Germany

PEDERSEN J.R.,; Alcatel Kabel Norge; Halden, Norway

1995 - D3-1

Partial discharge location as a cable operating tool

MASHIKIAN Matthew S.; University of Connecticut; Connecticut, USA

VALDES G., GONZALEZ V.; Florida Power & Light Co.; USA

KATZ C.;Cable Technology Labs.; New Brunswick, NJ, USA

1995 - D3-2

Development of a partial discharge automatic-monitoring system for EHV XLPE insulated cable lines

TOYA A., GOTO T.; Tokyo Electric Power Co.; Tokyo, Japan

ENDOH T., SUZUKI H., TAKAHASHI K.; Hitachi Cable Ltd; Ibaraki, Japan

1995 - D3-3

Partial discharge in medium voltage extruded cable joints

LAMARRE Laurent, MORIN R.; IREQ; Varennes Québec, Canada

1995 - D3-4

HF partial discharge detection of HV extruded cable accessories

PULTRUM E.; KEMA; Arnhem, The Netherlands

VAN RIET M.J.M.; NUON; Duiven, The Netherlands

1995 - D3-5

Ultra-wide bandwidth PD measurements application to open air testing of 230 kV XLPE cables

BRAUN JM., HORROCKS D.J., LEVINE JP., SEDDING H.G.; Ontario Hydro Tech.; Toronto, Canada

HIIVALA L., HARTLEY M.; Alcatel CanadaWire; Toronto, Canada

1995 - D3-6

Measurement and location of partial discharges during on-site testing of XLPE cables with impulse voltages

KRAGE 1., STREHL T., KALKNER W.; TU of Berlin; Germany

1995 - E-1

Investigation of the effects of electrode type and temperature on the remanent electric field in low density polyethylene using the thermal step method

KHALIL M.S.; Sultan Qaboos University; Muscat, Sultanate of Oman

CHERIFI A.; Université de Caen; Octeville, France

TOUREILLE Alain, REBOUL J.-P.; Université de Montpellier Il; Montpellier, France

1995 - E-2

Characterization and diagnostic of HV and VHV cables by the thermal step method

TOUREILLE Alain; Univ. Montpellier Il; Montpellier, France

SANTANA José, BERDALA Jacques; Câbles Pirelli; Sens, France

1995 - E-3

Space charge measurement of HV and EHV XLPE cables submitted to ageing under high stress

SANTANA José, BERDALA Jacques; Câbles Pirelli; Sens, France

TOUREILLE Alain; Université Montpellier Il; Montpellier, France

1995 - E-4

Influence of annealing on the electric behaviour of low density polyethylene

MORIN P., ALQUIÉ C., LEWINER J.; ESPCI; Paris, France

ARGAUT P.; SILEC; Montereau, France

1995 - E-5

Results of tests using continuous high voltage on low density polyethylene insulation

BOURGEAT X.; EDF/DER; Moret-sur-Loing, France

LUTON M-H.; SILEC; Montereau, France

1995 - E-6

Evidence of a strong correlation between space charge build· up and breakdown in cable insulators under DC stress

ZHANG Y., LEWINER J., ALQUIÉ C.; ESPCI; Paris, France

HAMPTON N.; BICC Cables Ltd; Erith, UK

1995 - E-7

Precursor phenomena on the breakdown of polyethylene

VELLA N., TOUREILLE Alain; Lab. d'Electrotechnique de Montpellier; Montpellier, France

ZEBOUCHI N., HOANG THEGIAM; Lab. de Génie Electrique; Toulouse, France

1995 - F-1

Effects of the UV radiation on PE and crosslinked polyethylene (XLPE) cables aged in humid environment

PENTEADO RA, ENGELSTEIN E.; COPEL/LAC; Paranà, Brazil

DAS-GUPTA DK,; University of Wales; Bangor, U.K.

1995 - F-2

Generation of colored trees under the influence of additives and impurities

TOYA A., KARASAKI T.; Tokyo Electric Power Co.; Tokio, Japan

TANIMOTO G., AIDA F.; Showa Electric Wire & Cable; Kawasaki, Japan

1995 - F-3

Water diffusion through sheaths and its effects on cable constructions

GEURTS W.S.M., STEENNIS E.F., POORTS C.J.H.M., MEIJER G.J.; KEMA; Arnhem, The Netherlands

1995 - F-4

Medium voltage polymeric power cables. Clarification of the cause of water treeing and methods of its prevention

DEJEAN Pierre-Marcel; Câbles Pirelli; Sens, France

BANKS VAA,; BICC Câbles; Clwyd,U.K.

MAYOUX C., MARTINEZ J.; Université Paul Sabatier; Toulouse, France

FOURACRE RA,; University of Strathclyde; Glasgow, U.K.

PEDROSO F.; CEL-CAT Morelana; Pero Pinheiro, Portugal

1995 - F-5

Water treeing acceleration vs. right temperature gradient

RYNKOWSKI AW.; TU of Gdansk; Poland

1995 - F-6

Light emission and electrical tree initiation in highly-stressed XLPE cable insulation

KABIR F., BRAUN JM., DENSLEY J.; Ontario Hydro; Toronto, Canada

HAMPTON N.; BICC Cables Ltd; Erith, UK

VERNE S.; BICC Plc; Hemel Hempstead, UK

1995 - F-7

Characterisation test on MV XLPE insulated cables

SISWADI; PT PLN; Jakarta, lndonesla

1999 - A10-1

Halogen free new recyclable cable with low toxic gas emission

YOSHINO A., SAWADA H., SUZUKI J., HASEGAWA M., MURAYAMA M., SHINMOTO T.; Fujikura Ltd.,; Tokyo, Japan

1999 - A10-2

Development of recyclable low-voltage insulated cable

YUKAWA H., OHASHI T, SAKASHITA H., KAMINO K.; The Kansai Electric Power Co. Inc; Osaka, Japan

HIURA T, SHIRATSUCHI N.; Sumitomo Electric Ind.; Osaka, Japan

1999 - A10-3

Consideration of environmental impacts in the cable design

BRIX S.; Alcatel Kabel; Nürnberg, Germany

DUBOTS P, NOËL B., PARASIE Y.; Alcatel; Paris, France

1999 - A10-4

Life cycle analysis of power cables in Norway

GJAERDE «c, SOLVANG E., VERLO T.; SINTEF Energy Research; Trondheim, Norway

1999 - A10-5

Shielding technique to reduce magnetic fields from buried cables

ARGAUT P, DAURELLE J.Y.; SAGEM SA; Montereau, France

PROTAT E, SAVINA K., WALLAERT C.A.; SUPELEC; Gif sur Yvette, France

1999 - A10-6

Cables and electromagnetic compatibility into aircraft

BRAIDOTTI V., ZANINELLI D.; Politecnico di Milano; Italy

1999 - A1-1

Completion of 500 kV XLPE cable links for the Okutataragi power generating station

SAKAGUCHI Yasuo, MIYAZAKI Toshihiro, ASAI Shinya; Sumitomo Electric Industries Ltd.; Osaka, Japan

NISHI Minori, NAKAZAWA Makoto, OKADA Masahiko; The Kansai Electric Power Co. lnc.,; Hyogo, Japan

1999 - A1-2

400 kV XLPE cables for the extension of Cleuson-Dixence Hydro power plants

WYLER c., BIOLLEY c.. HEIZMANN T, MARRO A,; Alcatel Cable Suisse SA; Cortaillod, Switzerland

NICOLET A.; Aménagement Cleuxon-Dixence; Sion, Switzerland

1999 - A1-3

The high voltage cables in the Ivorian power system

DIARRASSOUBA A,; Compagnie Ivoirienne d'Électricité; Abidjan, Ivory Coast

1999 - A1-4

Installation of 400 kV XLPE cables in the NESA supply area

CHRISTENSEN P, LAGERSTEDT K., OKHOLM A.; NESA A/S; Gentofte, Denmark

1999 - A1-5

Design of new 150 kV XLPE cable system for the Belgian electrical network

COUNESON P, BRUS B.; Tractebel; Bruxelles, Belgium

ARGAUT P, MARTIN B.; SAGEM SA; Montereau, France

1999 - A1-6

Construction of long distance 500 kV XLPE cable line

OHATA K, TSUCHIYA S.; Tokyo Electric Power Co. Ltd.,; Tokyo, Japan

SHINAGAWA N.; The Furukawa Electric Co. Ltd.,; Tokyo, Japan

FUKUNAGA S.; Sumitomo Electric Industries Ltd.,; Tokyo, Japan

OSOZAWA K.; Hitachi Cable Ltd; Tokyo, Japan

YAMANOUCHI H.; Fujikura Ltd.; Tokyo, Japan

1999 - A2-1

The design of power cables to operate at high electrical stress

DEMARIA G.; BICC Ceat Cavi; Italy

GREGORY B., GRIFFITHS c.t.. HAMPTON R.N., MAINWARING S.P.; BICC Cables Ltd; Erith, UK

1999 - A2-2

State of the art in EHV XLPE cable systems

BOLZA A,; Pirelli Cavi S.p.A,; Italy

KUNZE D.; Pirelli Cable and Systems;

NORMAN S.; Pirelli Cavi e Sistemi; Milano, Italy

POHLER S.; Pirelli Kabel und Systems; Germany

1999 - A2-3

Prequalification testing of 290/500 (525) kV extruded cable system at IREQ

PARPAL J.L.; Hydro-Québec (lREQ),; Québec, Canada

BEZILLE J., GAHUNGU F., BECKER J., MIREBEAU P.; Alcatel Cable; Calais, France

CARDINAELS J.,; Alcatel Euromold; Erembodegem, Belgium

MEURER D.,; Alcatel; Germany

1999 - A2-4

Qualification of a new technical step cable system for the 90 kV network

BEZILLE J., COELHO D., GAHUNGU F., MIREBEAU P.; Alcatel Cable; Calais, France

CARDINAELS J.; Alcatel Euromold; Erembodegem, Belgium

1999 - A2-5

Qualification test program of 115 kV rated, 3500 kcmil and 138 kV rated, 1500 kcmil high-pressure gas-filled cables

AHMED N., SRINIVAS N.; Detroit Edison Company; Detroit, USA

KUCHTA Frank L., CINQUEMANI P.; Pirelli Cable Corporation; Lexington, USA

1999 - A2-6

Technological advances in reliable HV XLPE foil laminate cable systems

FORD A,; Formerly with London Electricity; United Kingdom

GREGORY B., KING S.M., SVOMA R.; BICC Cables Ltd; United Kingdom

1999 - A3-1

Gas-insulated transmission lines (GIL). Type tests and prequalification

SCHÜETTE A, KOCH H.; Siemens AG; Erlangen, Germany

1999 - A3-2

Optimized gas-insulated transmission line

GUILLEN M.; Alstom T&D; Villeurbanne, France

BERTRAND M.; Alstom T&D; Aix les Bains, France

1999 - A3-3

Long term test of a directly buried GIL prototype

BOURDET M., HOPKINS M.; ABB Énergie; La Défense, France

FELDMANN D.; EDF DER; Moret sur Loing, France

MAUGAIN Yves; EDF Production Transport; Courbevoie, France

1999 - A3-4

Development of a high temperature superconductivity power delivery system

HUGHEY R.L.; Southwire; Carrollton, USA

1999 - A3-5

Latest development of high temperature super conductor (HTSC) cable systems

LADIE PL., NASSI M., NORMAN S.R.; Pirelli Cavi e Sistemi; Milano, Italy

SCHROTH R.G.; Pirelli Kabel und Systems; Berlin, Germany

1999 - A3-6

Pirelli-EDF DEVELOPMENT on superconducting cables

LADIE PL., NASSI M., NORMAN S.R., CARACINO P.; Pirelli Cavi e Sistemi; Milano, Italy

COVOET M., BOISSEAU C., SIROT P.F.; EDF DER; Moret sur Loing, France

1999 - A3-7

Design of a high temperature superconducting cable termination

HATHAWAY G.M., DAVIES A.E.; University of Southampton; Hampshire, United Kingdom

SWINGLER S.G.; The National Grid; Leatherhead, Surrey, UK

1999 - A3-8

European superconducting power link project

VERHAEGE T., HERRMANN P.F.; Alcatel; Marcoussis, France

BOCK J., BAECKER M.; Aventis; Hürth, Germany

MOULAERT G.; Laborelec; Linkebeek, Belgium

FREYHARDT H.C., USOSKIN A.; ZFW GmbH; Gbttingen, Germany

LEHTONEN J., PAASI J.; TUT; Tampere, Finland

1999 - A4-1

Thermomechanical modelling of 345 kV XLPE cables in duct

TARNOWSKI J, IORDANESCU M., AWARD R., ROYER C.; Hydro-Québec (lREQ),; Québec, Canada

1999 - A4-2

Thermomechanical behaviour of 400 kV synthetic cables

BRINCOURT T, DORISON E.; EDF DER; Moret sur Loing, France

1999 - A4-3

New mechanised laying techniques of MV cables with geosynthetic protection

BRINCOURT T.; EDF DER; Moret sur Loing, France

ROBIN J.C.; MARAIS; Miré, France

BOUCHER M.,; RIMAUDIERE; Mios, France

LEFLAIVE E., PUIG J.; Ingénieurs Conseil; France

1999 - A4-4

Cable laying : State of art for the laying of HV and EHV cable systems

MAUGAIN Yves; EDF Production Transport; Courbevoie, France

HUDSON P.; Pirelli Construction; Eastleigh, United Kingdom

1999 - A4-5

Installation of a new technical step 90 kV cable system. A real experience on the French network

BERDALA Jacques, DEJEAN Pierre-Marcel, MANSOUR Jawdat; Câbles Pirelli; Sens, France

MAXAN A.; Câbles Pirelli; Saint Maurice, France

1999 - A4-6

Installation of 220 kV XLPE cables in a tunnel installation whilst Minimising electromagnetic induction in communication cables

GREGORY B.; BICC Supertention & Subsea Cables; Erith, UK

MONTEYS J.; BICC General Cables; Barcelona, Spain

BARRIS S.; Enher-Hec;

MENDEZ J.M.; Consultant;

1999 - A4-7

400 kV insulated cable Link installation carried out at the Chaira pumped storage power plant in Bulgaria

LAVANTUREUX P., DEGUINES P., GAHUNGU F.; Alcatel Cable; France

TODOROV T,; Nationalna Elektricheska Kompania; Sestrimo, Bulgaria

1999 - A4-8

The mechanical laying of underground high voltage cables (63 and 90 kV) in France

FIGARET Christophe; EEE; Nîmes, France

1999 - A5-1

170 kV common termination system for cables with extruded insulation

DE RIDDER E.; Alcatel Euromold; Erembodegem, Belgium

MONSEN O.B.; Alcatel Norge; Oslo, Norway

1999 - A5-2

Development of prefabricated joint for 500 kV XLPE cable

OKADA M.; The Kansai Electric Power Co. Inc; Osaka, Japan

SATO M.,; Sumitomo Electric Ind. Ltd.,; Osaka, Japan

YAMASHITA Y.; The Furukawa Electric Co. Ltd.,; Chiba, Japan

HARA M.,; Hitachi Cable Ltd; Ibaraki, Japan

NIINOBE Hiroshi; Fujikura Ltd.,; Chiba, Japan

1999 - A5-3

Development of high stress cable and accessories for EHV XLPE cable systems in Korea

YOON H.H., KWAK B.M.; KEPCO; Seoul, South Korea

OH J.O., CHOI S.G., HUH G.D., PARK W.K.; LG Cable; Korea

1999 - A5-4

Development of synthetic and composite terminations for HV and EHV extruded cables

LE PEURIAN S.; EDF DER; Moret sur Loing, France

JUNG M.; EDF Production Transport; Courbevoie, France

1999 - A5-5

Operating experience with lapped high voltage cable joints made from EPR tapes

JENNI A.; Hivotec Ltd; Binningen, Switzerland

RENGEL U., MEIER A.; Brugg Kabel AG; Brugg, Switzerland

OSLEY J.; MOS Engineering AG; Mellingen, Switzerland

1999 - A5-6

Development of sheath-interrupter for EHV cables

YUKIHIRO K., TAKAYUKI K.; Chubu Electric Power Co. lnc.,; Nagoya, Japan

KOICH K., TOSHIMITSU T,; Hitachi Cable Ltd; Japan

1999 - A5-7

Development of block molded joint for 275 kV XLPE cable and its application to actual line

TSUCHIYA S., YONEMOTO N.; Tokyo Electric Power Co. Ltd.,; Tokyo, Japan

SHIMOMURA T, NAKAMURA S.; Mitsubishi Cable Ind. Ltd.,; Tokyo, Japan

1999 - A6-1

Eddy current losses

ARGAUT P., LESUR F.; SAGEM SA; Montereau. France

1999 - A6-2

Advanced topics in rating of power cables

ANDERS G. BRAUN J.M., VAINBERG M., RIZETTO; Ontario Hydro Technoloqies; Toronto, Canada

BRAKELMANN; Gerhard-Mercartor-Universitat; Duisburg, Germany

1999 - A6-3

Using the finite element method for complex cable ampacity calculations : A more accurate and much more flexible alternative to the conventional analytical

methods

CHAABAN M. LEDUC J.; Hydro Québec (IREQ); Québec, Canada

1999 - A6-4

The additional losses in the metallic screens of high voltage cables

DEJEAN Pierre-Marcel; Câbles Pirelli; Sens, France

FONTANA M. REMY C. ZACCONE E.; Pirelli Cavi S.p.A.; Milano, Italy

1999 - A6-5

Sirolex : A finite element computer program for the thermal analysis, design and monitoring of underground and aerial high and medium voltage insulated

cable systems

KEMP R.C. ; CSIRO National Measurement Laboratory; Lindfield, Australia

BARBER K.W., BARNEWALL G.D. JANSEN M. MUXWORTHY M. PIECHOTA R. SOETOPO Y,; Olex Cables; Tottenham, Australia

1999 - A6-6

Simplified expressions for the evaluation of the cyclic ratings of low voltage and medium voltage cables in non sinusoidal conditions

CARAMIA P, CARPINELLI G. VERDE P.; University of Cassino; Italy

1999 - A7-1

Transmission capacity design of underground power cables

OKADA M.; The Kansai Electric Power Co. inc; Osaka, Japan

KARASAKI T.; Tokyo Electric Power Co. inc; Tokyo, Japan

FURUHATA H.; Chubu Electric Power Co. inc; Aichi-Ken. Japan

IMAJO N.; Central Research Institute of Electric Power Industry; Kanagawa-Ken, Japan

MITANI M.; Sumitomo Electric Industries Ltd; Osaka, Japan

SAKUMA S.,; Furukawa Electric Co. Ltd; Tokyo, Japan

1999 - A7-2

Potential overheating in the event of a cable crossing

THEVENON Henri; Consultant; Lyon, France

COUQUET JM.,; Alcatel Cable; Calais, France

1999 - A7-3

Thermal design of controlled backfills

ARGAUT, P., LESUR F.; SAGEM SA,; Montereau, France

MERMET G., PROTAT F., SPORREL U.; SUPELEC; Gif sur Yvette, France

1999 - A7-4

Pipe-type cables : retrofitting and ampacity

ARGAUT, P, LESUR F; SAGEM SA; Montereau, France

1999 - A7-5

New applications of extruded solid dielectric cables

CARTENSSEN P, LEIJON M.; ABB Corporate Research; vasteras, Sweden

JOHANNESSON K.; ABB High yoltage Cables AB; Karlskrona, Sweden

SÖRQVIST T.; ABB Generation AB; vasteras. Sweden

1999 - A8-1

Research of property of low-smoke halogen-free flame-retardant power cable

PING S.; Shenyang Cable Works; China

1999 - A8-2

Updated status of the FIPEC project (Fire Performance of Electrical Cables)

VAN HEES P; Swedish National Testing & Research Institute, Fire Technology; Sweden

BREULET H.; Institut Scientifique de Service Public; Belgium

VERCELLOTTI U.; CESI; Milano, Italy

GRAYSON S., GREEN A.; Interscience Communications; United Kingdom

1999 - A8-3

Water tree accelerated ageing tests for MV XLPE cables

STEENNIS Evert Frederik, GEURTS W.S.M., MEIJER G.J.; KEMA; Arnhem, The Netherlands

1999 - A8-4

Development of oil sampling devices for energized oil filled cable system

OKADA M., TANAKA N., TAMURA K., TSUJI T.; The Kansai Electric Power Co. Inc; Osaka, Japan

IWAMOTOT; Sumitomo Electric Industries Ltd; Japan

HATA Toshio; The Kansai Tech. Co; Japan

1999 - A8-5

Leak detection in high pressure pipe-type cables using artificial neutral networks

ANDERS G.J., BRAUN J.M., FISCHER D., RIZZETTO S., VAINBERG M.; Ontario HydraTechnologies; Toronto, Canada

GHAFURIAN R., TANG L.; Consolidated Edison Co.,; New York, USA

1999 - A9-1

On-site partial discharge diagnostics of medium voltage power cables

GULSKI Edward, SMIT J.J.; Delft University of Technology; Delft, The Netherlands

SElTZ P.N.; Seitz Instruments &Co.,; Switzerland

KONING R.F.F.; NKF Kabel BV,; The Netherlands

TURNER M.; Haefely Trench AG,; Switzerland

1999 - A9-2

On-site AC test after installation for long HV and EHV cables

VAN SCHAIK N., DE LIGT C. PULTRUM E.; KEMA; Arnhem, The Netherlands

1999 - A9-3

Partial discharge measurement with freely oscillating resonance voltage

ONODI T, Dàtwyler AG.; Altdorf; Switzerland

1999 - A9-4

Advanced measuring system for the analysis of dielectric parameters including PD events

LEMKE E., STREHL T.; Lemke Diagnostics GmbH; Volkersdorf, Germany

1999 - A9-5

Achievements in operation of XLPE cables in Japan

OHATA K.; Tokyo Electric Power Co; Tokyo, Japan

NAKAGAWA S.; Kansai Electric Power Co; Osaka, Japan

FURUHATA H.; Chubu Electric Power Co; Nagoya, Japan

1999 - B10-1

The influence of semiconductive screen materials on electrical performance

HAMPTON R.N., MOODY S.M.; BICC Cables Ltd; Erith, UK

FREESTONE J.; BICC Cables Corp; Indianapolis, USA

1999 - B10-2

New grading material for terminations and joints

MOHAUPT Peter; High Voltage Engineering Ltd.,; Basel, Switzerland

GLEYVOD R.; High Voltage Engineering Ltd; Basel, Switzerland

RODER R.; CELLPACK AG,; Wohlen, Switzerland

1999 - B10-3

New polyethylene compounds for cable jacketing applications

HENSCHKE O.,BARTSCHEK K., AARTS M.; DOW BSL Olefinverbund GmbH; Merseburg, Germany

1999 - B10-4

Advanced polyethylene jacketing compounds for medium and high voltage cable applications

GAU Y,; Union Carbide Europe SA; Meyrin, Switzerland

PERSON TJ.; Union Carbide Corporation; Somerset, NJ, USA

KMIEC C.J.; Union Carbide Corporation; Somerset, NJ, USA

1999 - B10-5

Medium and high voltage cables having laminate sheaths with coated copper

BOW Kenneth E.; The Dow Chemical Company; Midland, USA

1999 - B1-1

Long term wet ageing of extruded dielectric cables

VAll J. , NOYES R.P., BANKS V.A A.; BICC Cables Energy; Wrexham, United Kingdom

HAMPTON R.N.; BICC Cables Ltd; Erith, UK

1999 - B1-2

Evaluation of important aspects for the long term service performance of axially and radially water tight XLPE

FAREMO H., BENJAMINSEN J.T.; SINTEF Energy Research; Norway

STEEN A,; Nordhordland; Norway

OLSEN J.A.; Hadeland Energiverk; Norway

1999 - B1-3

Moisture penetration in XLPE and PlLC cables

GEURTS W.S.M., ROSS R., MEGENS M.G.M., STEENIS E.F.; KEMA; Arnhem, The Netherlands

1999 - B1-4

Local effects of water entering XLPE insulation through damaged sheaths

JORGENSEN H.J.; DEFU; lyngby, Denmark

JENSEN A,; NKT Cables; Denmark

STROBECH E.; NKT Research Center; Denmark

URSIN C.; CU Test & Development; Denmark

1999 - B1-5

Water penetration in the insulation of medium voltage cables

PELISSOU Serge; Hydra-Québec (lREQ),; Québec, Canada

ST-ANTOINE S.; Hydra-Québec (Distribution),; Québec, Canada

1999 - B2-1

Progress in quality of XLPE insulation for medium voltage cables

RAKOWSKA Alexandra, HAJDROWSKI K.; Poznan University of Technology; Poznan, Poland

1999 - B2-2

Technical advancements in the underground medium voltage cable specifications of the USA largest investor owned utilities

DUDAS J.H.; Consultant; Longview, USA

COCHRAN W.H.,; Cinergy; Cincinnati, USA

1999 - B2-3

Extruded MV cables and accessories with increased electrical stress

SCHADLICH H., MEURER D.; Alcatel; Hannover, Germany

KRAHENBÜHL F.; Alcatel,; Cortaillod, Switzerland

CHANEL J.; Alcatel; Bourg en Bresse, France

SCHIAFFINO P.; Alcatel; Latina, Italy

DE RIDDER E.; Euromold; Erembodegem, Belgium

BECKER J.; Alcatel,; Charleroi, Belgium

LAURENT M.; Alcatel; Cossonay, Switzerland

1999 - B2-4

Modelling electric treeing in XLPE insulation using electric field concepts

GANGA S., NAGAMANI H.N., MOORCHING S.N.; Central Power Research Institute; Bangalore, India

1999 - B3-1

A review of the influence of frequency on accelerated aging of PE and XLPE cables

CRINE Jean Pierre; Technology Consultant; Brossard, Canada

JOW J.; Union Carbide; USA

1999 - B3-2

Aging of electrical underground distribution cable joints

AMYOT N., FOURNIER D.,; Hydra-Québec (IREQ),; Québec, Canada

1999 - B3-3

AC field ageing of power cables

PARPAL J.L.; Hydro-Québec (lREQ); Québec, Canada

MIREBEAU Pierre, COELHO D., JANAH H., GAHUNGU F,; Alcatel Cable; Calais, France

CARDINAELS J.; Alcatel; Belgium

MEURER D.; Alcatel; Germany

1999 - B3-4

Life estimation of water tree deteriorated XLPE cables by VLF (Very Low Frequency) voltage withstand test

UCHIDA K., KATO Y.; Chubu Electric Power Co., Inc; Aichi, Japan

TANAKA T., TANAKA A.; Tokyo Electric Power Co. Inc.; Yokahama, Japan

SAKAKIBARA H., TANAKA H.; The Furukawa Electric Co. Ltd.,; Chiba, Japan

1999 - B3-5

Water treeing as diffusion-with-reaction process

SHUVALOV Mikhail, MAVRIN M., OBRAZTSOV Yuri; JSC VNIIKP; Moscow, Russia

1999 - B4-1

New interpretation of long-term test results of MV cables : Material ageing or internal defect structure development

MORAWIETZ K.; Fraunhofer Institute for Mechanics of Materials; Halle, Germany

HEIDMANN G.; Kaiser KWO Kabel Energie GmbH; Berlin, Germany

RIECHERT U.; TU of Dresden; Germany

WUTZLER A.; Martin-Luther-University; Halle-Wittenberq, Germany

1999 - B4-2

Assessment under high dielectric field of the long term behaviour of power cable polyethylene insulant

CLAVREUL R.; EDF DER; Moret sur Loing, France

LUTON M.H.; SAGEM SA; Montereau, France

BERDALA Jacques; Câbles Pirelli; Sens, France

JANAH H.; Alcatel Cable France; Calais, France

LAURENSON P.; Borealis; Zwinjdrecht, Belgium

1999 - B4-3

The effect of temperature on dielectric characteristics of XLPE

TANAKA TI TANAKA A.,; Tokyo Electric Power Co.; Yokohama, Japan

SHIBATA T, HIROTSU K.; Sumitomo Electric Ind. Ltd; Osaka, Japan

1999 - B4-4

About electrical conductivity related to heterogeneous bulk structure of polyethylene

BERTIN C, GUASTAVINO J., MAYOUX C.; Laboratoire de Génie Électrique de Toulouse; France

DRUOT P.; Borealis AB; Stenungsund, Sweden & Singapore

1999 - B4-5

Evaluation of insulation degradation of stressed XLPE cables

GARROS B.; Alcatel CIT; Marcoussis, France

AUDRY C.; SAFT; Marcoussis. France

SCHADLICH H.; Alcatel Kabel; Hannover, Germany

MONTANARI Gian Carlo, BENCIVENNI L.; DIE, University of Bologna; Italy

1999 - B4-6

Practical tool for cable ageing monitoring : dynamic mechanical analysis (DMA)

BOUTAUD F.; EDF DER; Moret sur Loing, France

CHAILAN J.F'I VERNET J.L.; Institut des Sciences de l'Ingénieur; Université de Toulon et du Var, France

1999 - B5-1

Diagnosis of service aged XLPE cables. Presentation of a Nordic utility research project evaluating different on-site dielectric response diagnostic test

methods

FAREMO H.; SINTEF Energy Research; Trondheim, Norway

CHRISTENSEN J.S.; DEFU; Lyngby, Denmark

WERELIUS P.; KTH; Stockholm, Sweden

OBERGER K.; Elforsk AB; Stockholm, Sweden

MORTENSEN K.B.; CDP; Kvaloysletta, Norway

1999 - B5-2

Evaluation of different diagnostic methods for the French underground MV network

BRINCOURT T, REGAUDIE V.; EDF DER; Moret sur Loing, France

1999 - B5-3

Characteristics of long term deterioration of XLPE cable and its diagnostic techniques in Japan

OHATA K.; Tokyo Electric; Tokio, Japan

FURUHATA H.; Chubu Electric; Nagoya, Japan

NAKAGAWA S.; Kansai Electric Co.; Osaka, Japan

SAKAMOTO T,; Mitsubishi Cable; Kumagaya, Japan

EBINUMA Y.; Showa Electric; Sagamihara, Japan

YOSHIDA T.; Furukawa Electric; Tokyo, Japan

1999 - B5-4

MV Cable maintenance, practices and results

VAN SCHAIK N., BOONE W., HETZEL E.; KEMA; Arnhem, The Netherlands

GROTENHUIS B.J.; REMU; Utrecht, The Netherlands

1999 - B5-5

Discharge current method. A test procedure for plastic-insulated medium-voltage cables

MUHR M., WOSCHITZ R.; Institute of High Voltage Engineering; Graz, Austria

1999 - B5-6

The return voltage method, a diagnostic tool to assess water tree damage in PE- and XLPE cables, and the experiences from the method in Romania

KAMENKA D.; Hagenuk KMT,; Radeburg, Germany

PISPIRIS C.S.; ICEMENERG; Bucarest, Romania

1999 - B6-1

Study on diagnostic method for water treed XLPE cable by loss current measurement

YAGI Y., TANAKA H. MUTO H. KIMURA H.; The Furukawa Electric Co. Ltd.; Chiba. Japan

1999 - B6-2

Behavior and diagnostic techniques of initial defects on XLPE insulated cable systems

NAKAGAWA T.; Hitachi Cable Ltd; Tokyo, Japan

OHATA K.; Tokyo Electric Power Co.,; Tokyo, Japan

NAKAGAWA S.; Kansai Electric Power Co; Osaka, Japan

FURUHATA H.; Chubu Electric Power Co.,; Nagoya, Japan

ASAI S.; Sumitomo Electric Industries Ltd.,; Osaka, Japan

YAMANOUCHI H.; Fujikura Ltd.; Tokyo, Japan

1999 - B6-3

Medium voltage cable testing by partial discharge location: A comparative discussion of field generated diagnostic results

MASHIKIAN Matthew S., HAN C, ZIEGLER S.; IMCORPTtm; Storrs, USA

1999 - B6-4

Partial discharge, predictive cable testing experience and lessons learned

REDER W.; Ultra Power Technologies lnc.,; Minneapolis, USA

1999 - B6-5

On-Line partial discharge detection and classification by pattern recognition on HV terminations

PULTRUM E., ROSS R.; KEMA; Arnhem, The Netherlands

GULSKI Edward; Delft University of Technology; Delft, The Netherlands

VAN RIET M.J.M.; Nuon Technisch Bedrijf; Duiven, The Netherlands

1999 - B6-6

On-site partial discharge diagnosis and monitoring on HV power cables

GROSS D.W.; Power Diagnostix Systems GmbH; Aachen, Germany

1999 - B7-1

Installation of 500 kV DC PPLP-insulated oil-filled submarine cable

INOUE T.; The Kansai Electric Power Co. Lnc; Osaka, Japan

MITANI M.; Sumitomo Electric Industries Ltd.,; Osaka, Japan

SHIIGETOSHI L.; Fujikura Ltd; Tokyo, Japan

MAEKAWA Y.; Electric Power Development Co. Ltd; Tokyo, Japan

FUJII O.; The Furukawa Electric Co. Ltd; Tokyo, Japan

SHIMADA M.; Hitachi Cable Ltd; Ibaraki, Japan

1999 - B7-2

Rectification of submarine cables of Croatian 110 kV cross-island connection

SAINA Bruno; The Croatian National Electricity; Opatija, Croatia

TOMASOVIC L, MOSER J.; The Croatian National Electricity; Zagreb, Croatia

1999 - B7-3

Development of XLPE cable under DC voltage

SATORU M., TANAKAT., MUTO H.; The Furukawa Electric Co. Ltd.,; Chiba, Japan

TERASHIMA K., WATANABE C.; Electric Power Development; Tokyo, Japan

1999 - B7-4

Experience in service of submarine power cables 150 kV in Bali strait

SINISUKA N.I.; Bandung Institut Teknology Bandung (lTB),; Bandung, Indonesia

PRIYADI B. H.,; PT PLN (PERSERO),; Jakarta, Indonesia

1999 - B7-5

The development of an extruded HVDC cable system and its first application in the Gotland HVDC Iight project

BYGGETH M., JOHANNESSON K.; ABB High Voltage Cables; Karlskrona, Sweden

LILJEGREN C.; GEAB (Gotlands Energiverk AB),; Visby, Sweden

PALMQVIST L.; ABB Kabeldon AB; Alingsas, Sweden

AXELSSON U.; Vattenfall; Stockholm, Sweden

JONSSON J., TORNKVIST C.; ABB Corporate Research; Vasteras. Sweden

1999 - B7-6

Research and development of DC XLPE cable and associated factory joint

TERASHIMA K., ASANO M.; Electric Power Development Co. Ltd.,; Tokyo, Japan

WATANABE K, YOSHIDA M., KON H.; Fujikura Ltd.,; Chiba, Japan

1999 - B7-7

The stability of mass-impregnated paper AC cables operated at DC voltage

MORSHUIS Peter H. F., ROEFS R.J., SMIT J.J.; University of Technology; Delft, The Netherlands

CONTIN A.; DEEI University of Trieste; Italy

MONTANARI Gian Carlo; University of Bologna; Italy

1999 - B7-8

Field distribution in HVDC cables : dependence on insulating materials (see also C2.13.)

ALADENIZE B., COELHO R., ASSIER J.C; Alcatel CRC; Marcoussis, France

JANAH H., MIREBEAU Pierre; Alcatel Cable; Calais, France

1999 - B8-1

A new method for the measurement of power cables AC resistance

BOURGEAT X.; EDF DER; Moret sur Loing, France

SANTANA José., FUSTIER Abel., DEJEAN Piere-Marcel; Câbles Pirelli; France

1999 - B8-2

Real time thermal of HV cables

PRAGNELL B.; Pirelli Cables Ltd.,; Eastleigh, United Kingdom

GASPARI R.; Pirelli Cavi S.p.A.; ItaN

LARSEN S.T.; The National Grid Company; United kingdom

1999 - B8-3

Conductor temperature estimation of underground cables

CARAMIA P., LOSI A., Russor\/i.; Universita' degli Studi di Cassino; Cassino,ltaly

1999 - B8-4

Cable temperature monitoring

BALOG G., NERBY T.I., KALDHUSSAETER E.; Alcatel Kabel Norge; Halden, Norway

1999 - B8-5

Calculation method of power cables AC resistance with individually insulated strands

ARGAUT P., DAURELLE J.Y.; SAGEM SA; Montereau, France

1999 - B8-6

Optimising high voltage underground cable links

LE PEURIAN S; EDF DER; Moret sur Loing, France

JUNG M.; EDF Production Transport; Courbevoie, France

1999 - B9-1

Influence of admittance asymmetry of underground cables in compensated systems behaviour

RUZ F.; Universidad de Murcia; Spain

GARCIA M.; Universidad Politecnica de Valencia; Spain

1999 - B9-2

Sheath overvoltages affecting specially bonded underground links during single-phase faults

VO VAN HUY H., DORISON E.; EDF DER; Moret sur Loing, France

1999 - B9-3

About disturbances in power systems at the transients due to switching operations of cable dynamics

TUSALIU P., TUSALIU V, TUSALIU D., TUSALIU M.; University of Craiova; Romania

1999 - B9-4

Electrical transient conditions of buried cable systems.

ARGAUT P, DAURELLE J.Y.; SAGEM SA; Montereau, France

1999 - B9-5

Integration of underground cables in an overhead line

TASSY J.; EDF Production Transport; Courbevoie, France

BOURGEAT X.; EDF DER; Moret sur Loing, France

1999 - B9-6

Switching overvoltages in complex networks

IOAN S., HURDUBETIU S., ANGHELUTA B.; Bucharest Politehnica University; Bucharest, Romania

1999 - C10-1

Type testing of cables and accessories

BERLIJN S.M., GRUNTJES R.J.B., ROELOFS G.P.T; Kema Nederland; Arnhem, The Netherlands

1999 - C10-10

Improved diagnosis of MV paper-insulated cables using signal analysis

VILLEFRANCE R.; NESA A/S; Gentofte, Denmark

HOLBOELL J.T., SORENSEN J.Aa.; Technical University of Denmark; Denmark

JORGENSEN H.J.; DEFU; Denmark

1999 - C10-11

Influence of test voltage shape and frequency on PD-activity of defects in XLPE insulated medium voltage cables

PEPPER D., KALKNER W.; Technical University of Berlin; Germany

1999 - C10-12

Mie Scattering characteristics of defects in cross-linked polyethylene insulation of power cables

ZHAO H., TU D.; Xian Jiaotong University; Xi'an, China

LU Y, LIU L.; Harbin University of Science & Technolog; Harbin, China

1999 - C10-13

Practical experience in partial discharge site location of XLPE cables using a digital discharge detector

FAWCETT R., HILDER D.; Robinson Instruments; USA

LARZELERE B.; ECI; NY, USA

1999 - C10-2

Partial discharge measurement in transmission-class cable terminations

AHMED N., SRINIVAS N.; Detroit Edison Company; Detroit, USA

1999 - C10-3

A comparative experimental investigation on various after laying test methods employable to 22.9 kV CN/CV distribution power cables

KOO J.Y., LEE J.S.; Han Yang University; KyungGi-Do, Korea

KIM J.T.; Daejin University; KyungGi-Do, Korea

1999 - C10-4

Electrical and acoustical PD on-site diagnostics of service aged medium voltage power cables

WESTER F.J.; Energie Noord West; Alkmaar, The Netherlands

GULSKI Edward, SMIT J.J.; Delft University of Technology; Delft, The Netherlands

1999 - C10-5

The estimation of electrical performance from highly censored test data

HAMPTON R.N.; BICC Cables Ltd; Erith, UK

WALTON M.D.; BICC Cables Corp; USA

BERNSTEIN B.; EPRI; USA

1999 - C10-6

Numerical model for radial symmetric sensors for partial discharge detection on XLPE insulated high voltage cables

HEINRICH R., KALKNER W.; Technical University of Berlin; Germany

JOBAVA R., GHEONJIAN A.; Tbilisi State University; Tbilisi, Georgia

1999 - C10-7

Time and frequency domain based non-destructive diagnosis in comparison to destructive diagnosis of service-aged PE/XLPE insulated cables

KUSCHEL M., KALKNER W.; Technical University of Berlin; Germany

1999 - C10-8

Diagnosis on power cables for determination of remaining lifetime : Experiences with oscillating wave test

PFEIFFER W., TREDE T; Technical University of Darmstadt; Germany

1999 - C10-9

Condition assessment of medium voltage power cables in industrial environments by means of VLF techniques

DE NIGRIS M., VERCELOTTI U., ZAGLIANI F.; CESI; Milano, Italy

1999 - C2-1

Study of AC charging ability of XLPE insulating for power cable

AGNEL S., TOUREILLE A.; Laboratoire d'Électrotechnique de Montpellier,; France

PLATBROOD G., GEERTS G.; Laborelec; Linkebeek, Belgium

1999 - C2-10

Space charge in AC-poled XLPE for HV cables

NOTINGHER P jr., TOUREILLE Alain; Laboratoire d'Électrotechnique; Montpellier, France

SANTANA José.; Câbles Pirelli; Sens, France

ALBERTINI M.; Pirelli Cavi e Sistemi; Milano, Italy

1999 - C2-11

Life modelling of AC cable insulation based on space-charge inference

MAZZANTI G., MONTANARI G.C.; University of Bologna; Italy

DISSADO Leonard A.; Leicester University; United Kingdom

1999 - C2-12

Cross-linked polyethylene materials for DC power cables

BOSTROM J.O., CAMPUS A, NILSSON U.H.; Borealis AB; Stenungsund, Sweden

CARTENSEN P., GUSTAFSSON A.; ABB Corporate Research; vasteras. Sweden

FARKAS A. Andras, JOHANNESSON K.,; ABB High Voltage Cables AB; Karlskrona, Sweden

1999 - C2-13

Field distribution in HVDC cables : dependence on insulating materials (see also B7.8.)

ALADENIZE B., COELHO R., ASSIER J.C.; Alcatel CRC; Marcoussis, France

JANAH H., MIREBEAU Pierre; Alcatel Cable; Calais, France

1999 - C2-14

Elastic-wave methods for the measurement of space charge distributions : evolution and perspectives

PARIS O., lEWINER J.; ESPCI, laboratoire d'Électricité Générale; Paris, France

DITCHI T., HOlE S.; Université P. & M. Curie, laboratoire des Instruments et Systèmes; Paris, France

1999 - C2-15

Calculation of charge density and electric stress in XLPE compounds

DAVIES AE., CHEN G., WU X.; University of Southampton; United Kingdom

HAMPTON R.N.; BICC Cables Ltd; Erith, UK

SUTTON Simon, SWINGLER S.G.; National Grid Company; United Kingdom

1999 - C2-16

Space charge measurement in dispersive dielectrics

DAVIES AE., CHEN G.; University of Southampton; United Kingdom

VAZQUEZ A.; Universitat of Politecnica Catalunya; Spain

1999 - C2-2

Investigation of the effects of temperature variations on space charge formation in polyethylene

KHALIL M.S.; College of Engineering, Sultan Qabos University; Muscat, Sultanate of Oman

CHERIFI A, REBOUL J.M., CARIN R.; Université de Caen Basse-Normandie; Caen, France

1999 - C2-3

The effect of different screens and conditioning on the charge trap sites in XLPE cables

BETTERIDGE S., NOYES R.P., VAIL J.; BICC Cables Ltd; Wrexham, United Kingdom

1999 - C2-4

On the derivation of quantities from space charge measurements for the characterization of cable insulation performance

FABIANI Davide, MONTANARI Gian Carlo; DIE, University of Bologna; Italy

ALBERTINI M., PEREGO G.; Pirelli Cavi e Sistemi; Italy

1999 - C2-5

Correlation between the space charges and the discharge current on a 20 kV DC cables (XLPE)

FANJEAU O., TRUONG V.H., MALEC D.; Laboratoire de Génie Électrique; Toulouse, France

1999 - C2-6

Towards an understanding of space charges trapping in cable polyethylene

MEUNIER M., QUIRKE N.; Imperial College; London, United Kingdom

BINESTI D.; EDF DER; Moret sur Loing, France

1999 - C2-7

Correlation between conduction and space charge studies on laminar dielectrics under DC stress

AL-SAOUR, CHANG F., HAMPTON R.N., HOBDELL SB.,; BICC Cables Ltd; Erith, UK

1999 - C2-8

Theoretical and experimental study of space charge under DC polarisation up to breakdown in power cable insulator

ZEBOUCHI N.; ABB Corporate Research OY; Vasteras, Finland

THE GIAM H.; Laboratoire de Génie Électrique; Toulouse, France

1999 - C2-9

Nature of carrier traps in polyethylene and possible implication in aging process

AUGE J.L., MARY D., TEYSSEDRE G., LAURENT C.; Laboratoire de Génie Électrique; Toulouse, France

BERDALA Jacques; Câbles Pirelli; Sens, France

CLAVREUL R.; EDF DER; Moret sur Loing, France

1999 - C5-1

Quick method for direct measurements of all important parameters concerning water transport and diffusion in XLPE cables

URSIN C., FICH PERDERSEN T.; CU Test & Development Ltd.,; Copenhagen, Denmark

1999 - C5-2

Water treeing detection in 15 kV cables using the thermal step method

CASTELLON J., MALRIEU S.; Advanced Metrology for Electrical Engineering; Montpellier, France

TOUREILLE Alain; Laboratoire d'Électrotechnique de Montpellier; France

1999 - C5-3

Product and process development of a peroxide injection cable with enhanced resistance in wet operating conditions

ROVIRA J., VILLAGRASA F., MARTINEZ J.D.; BICC General Cables; Barcelona, Spain

MATEY Gabriel, LABBE D.; Products & Marketing Ltd.,; Geneva, Switzerland

1999 - C5-4

Development and application of a sample test for water treeing in medium voltage cables

LE POIDEVIN G., MCINTOSCH L.A, NAYBOUR R.D.; EA Technology; Chester, United Kingdom

1999 - C5-5

Water treeing in polyethylene insulation of power cables

KANISKIN V.A, POLONSKY YA,; St. Petersburg State Technical University; St. Petersburg, Russia

1999 - C5-6

Fourth generation dielectric enhancement technology

JENKINS K.A, BERTINI G.J.; UtilX Corporation; Kent, WA, USA

1999 - C5-7

Polymer modified XLPE as insulation in power cables

NILSSON U.H., CAMPUS A.; Borealis AB; Stenungsund, Sweden

MONTANARI Gian Carlo; University of Bologna; Italy

1999 - C5-8

Estimation of thermal loss of life of MV/LV cables taking into account moisture migration

CARAMIA P., LOSI A, RUSSO A., VERDE P.; University of Cassino; Italy

1999 - C6-1

Decomposition of high pressure SF6 and SF6-N2 (10-90) mixtures submitted to negative polarity corona discharges. Effect of the percentage of water added

VIAL L., CASANOVAS A.M., COLL L, CASANOVAS J.; Université Paul Sabatier; CPAT, Toulouse, France

CLAVREUL R.; EDF DER; Moret sur Loing, France

1999 - C6-10

Antioxidant concentration distribution measurement in XLPE cable insulation by PIXE Analysis, FTIR and UV spectroscopy

PARPAL J.L., GUDDEMI C.; Hydra-Québec (lREQ); Québec, Canada

HINRICHSEN; Université de Montréal; Canada

1999 - C6-11

Characterization of the dynamical structure of cable insulation

MENEGOTTO J., LACABANNE C.; Laboratoire Physique des Polymères; Toulouse, France

MAYOUX C.; Laboratoire de Génie Electrique; Toulouse, France

PLATBROOD G.; Laborelec; Linkebeek, Belgium

1999 - C6-12

Interface behaviour in HV and EHV accessories

GAHUNGU François, MIREBEAU Pierre; Alcatel Cable; Calais, France

ASSIER JC, GARROS B., ALADENIZE B., COELHO R.; Alcatel CRC; Marcoussis, France

CARDINAELS J,; Alcatel Euromold; Erembodegem Belgium

1999 - C6-2

Low density polyethylene microstructure observation under AC or DC high stress

BERTIN C, GUASTAVINO J., MAYOUX C, MARTINEZ-VEGA JJ.; Laboratoire de GénieÉlectrique; Toulouse, France

CAMPUS A.; Borealis AB; Stenungsund, Sweden

1999 - C6-3

Varistor composites for cable applications

RIEUX N. PERRIN S.; Alcatel Corporate Research Center; Marcoussis, France

PARASIE Y.; Alcatel Cable; Paris, France

1999 - C6-4

Electroluminescence in XLPE due to impulses superimposed on AC voltage

BAMJI S.S. BULINSKI A.T.; National Research Council of Canada; Ontario. Canada

TOHYAMA K.; Numazu College of Tech.,; Numazu, Japan

1999 - C6-5

The study of on-line relaxation effect on internal mechanical stresses and dielectric strength of HV cable insulation

SHUVALOV Mikhail, OBRAZTSOV Y. OVSIENKO V., KRUCHKOV A.; AII-Russian Scientific Research& Development Cable lnstitute; Moscow, Russia

HUOTARI P.; Nextram Technologies; Vantaa, Finland

1999 - C6-6

Optimization of cable terminations equipped with non-linear stress control tubes

PETRARCA C.; Università di Napoli "Frederico II"; Napoli, Italy

EGIZIANO L. TUCCI V.; Università di Salerno; Fisciano, Italy

VITELLI M.; Seconda Università di Napoli; Aversa, Italy

1999 - C6-7

Comparison between Lewis and Crine models for the electrical aging of extruded cables

CRINE Jean Pierre; Technology Consultant; Brossard, Canada

1999 - C6-8

Influence of a solid organic insulator on the arc decomposition and high energy spark decomposition of SF6 and SF6-N2 (10-90) mixtures

COLL I., CASANOVAS A.M ., VIAL L., GLEIZES A., CASANOVAS J.; Université Paul Sabatier; CPAT, Toulouse, France

CLAVREUL R.; EDF DER; Moret sur Loing, France

1999 - C6-9

An analysis of the interfacial region of HV cables using electrostatic force microscopy

BETTERIDGE S.; BICC Cables Ltd; Wrexham, United Kingdom

LEWIS lJ., LLEWELLYN J.P.; SEECS University of Walesl Banqor; United Kingdom

HAMPTON R.N.; BICC Cables Ltd; Erith, UK

1999 - C9-1

High performance conductor shields for HV/EHV solid dielectric power cables

REID C. G.; Union Carbide Corporation; Somerset, NJ, USA

1999 - C9-2

New potentialities of conducting polymers for cables

COTTEVIEILLE D., CARIOU F; Alcatel Corporate Research Center; Marcoussis, France

MIREBEAU Pierre; Alcatel Cable; Calais, France

DEMAY J.N.; Alcatel Cable; Lyon, France

PARASIE Y; Alcatel Cable; Paris, France

1999 - C9-3

Application of new ethylene elastomers in wire and cable

HEMPHILL J.,; Dupont Dow Elastomers; Freeport, USA

1999 - C9-4

XLPE insulation under thermomechanical stress - a model-like explanation of the behaviour of an intelligent material

GITSCHNER H.W.; Felten &Guilleaume Kabelwerke GmbH; Cologne, Germany

1999 - C9-5

Evaluation of a new EPDM insulation compound for HV cable accessories

GUSTAFSSON A.; ABB Kabeldon AB; Alingsas, Sweden

PALMQVIST L.; ABB Corporate Research; Vàsteras. Sweden

1999 - C9-6

Novel ambient curing and scorch retardant system for moisture crosslinkable polyethylene

FAGRELL O.; Borealis AB; Stenungsund, Sweden

1999 - C9-7

The development of a quality control technique to quantify the cleanliness of semiconductive materials

AKERMARK G., CAMPUS A., NILSSON U.H.; Borealis AB; Stenungsund, Sweden

MULLER K.B.; ABB Kabel und Draht GmbH; Mannheim, Germany

STUCKI F.; ABB Corporate Research; Baden-Dâttwil, Switzerland

1999 - C9-8

High performance HVDC polymer cable

TANAKA T, KUNII K.; Tokyo Electric Power Company; Yokohama, Japan

NAKATSUKA T, MIYATA H., TAKAHASHI T.; Fujikura Ltd; Tokyo, Japan

2003 - A10-1

Power drive rollers pulling improvements

HERBRETEAU A.; Omnium Technique du Câble; France

THEVENON Henri; Consultant; France

2003 - A10-2

Mechanical laying of HDPE ducts in rural area

MARTY L., LE CORGUILLE J.L.; RTE France; France

2003 - A10-3

Restraining the migration of HV cables in duct

TARNOWSKI J., IORDANESCU; Institut de Recherches d’Hydro-Québec; Canada

AWAD R.; Hydro-Québec; Canada

2003 - A10-4

Construction of 275 kV underground transmission line composed of continuous 2,500m long cable

HAYASHI N., SAITOU H., SHIMOHIRO D., KAWAI T.; Chubu Electric Power Co. Inc.; Nagoya, Japan

KAWAI T.; Chubu Electric Power Co. Inc.; Japan

ISHII N.; The Furukawa Electric Co. Ltd; Tokyo, Japan

HIRASAWA T.; VISCAS Corporation; Tokyo, Japan

WATANABE M., NAKAGAWA T; J-Power Systems Corp.; Japan

2003 - A10-5

Innovative installation method using water as a carrying fluid do install power cables in-pre lubricated ducts in trenches of reduced dimensions

TRICHARD C.; Netconcept; France

BLANC C.; Novoplastic; France

G. PLUMETTAZ; Plumettaz SA; Switzerland

2003 - A10-6

Increasing cable drum lengths

LESUR Frédéric; EDF R&D; Moret-sur-Loing, France

ARGAUT P., SACHER J.; SAGEM; Montereau, France

2003 - A1-1

Design and commissioning test of a 230- kV cross-linked polyethylene insulated cable system

KHAJAVI M.B.; Los Angeles Department of Water And Power; USA

ZENGER Walter; EPRI; USA

2003 - A1-2

Undergrounding the first 400 kV transmission line in Spain using 2 500 mm2 XLPE cables in a ventilated tunnel: the Madrid Barajas airport project

GRANADINO R., PORTILLO M.; Red Electrica de España; Spain

PLANAS J.; Pirelli Cables y Sistemas; Spain

SCHELL F.; ABB Energiekabel; Germany

2003 - A1-3

Pre-selection of cable type and cable manufacturers for the MetroGrid project in Sydney Australia

JONES S.J.; Transgrid; Australia

BUCEA G.; Transgrid; Australia

MAYER H.A.; Engineering Consultant; Australia

2003 - A1-4

Utility experience in establishing technical standards specification for powers cable projects: A case study from Gulf area

Dr. EL-HOSSEINY TAHA EL-SHIRBEENY; Abu Dhabi Water and Electricity Authority; United Arab Emirates

2003 - A1-5

Development of 275 kV XLPE cable with aluminium laminated tape and radial moisture Barrier

UMEDA K., MATSUURA K.; The Kansai Electric Power Co, Inc.; Japan

WATANABE M., SAKAGUCHI Y., OHIMO T.; J-Power Systems Corp.; Japan

2003 - A1-6

Real time monitoring of power cables by fibre optic technologies tests, applications and outlook

LUTON M-H.; Sagem; Montereau, France

ANDERS G.J., BRAUN J.M., FUJIMOTO N., RIZZETTO S.; Kinectrics Inc.; Canada

DOWNES J.A.; Sensa; UK

2003 - A2-1

Qualification of a highly electrically and mechanically stressed AC cable system

ERICSSON A., THUNWALL Bo.; ABB Power Technologies; Sweden

GUSTAFSSON A., SVAHN J.; ABB Power Technologies; Sweden

2003 - A2-2

120 kV cable installation at Beauharnois power station

CHOQUETTE M.; Hydro-Québec; Canada

CANAAN A.; Pirelli; Canada

2003 - A2-3

A new generation of optimised 120 kV cable systems at Hydro-Quebec

ROYER Christian, AWAD Ray, BOYER P., CHOQUETTE M., GIGNAC R., PARPAL Jean-Luc; Hydro-Québec; Canada

CANAAN A.; Pirelli; Canada

2003 - A2-4

Prequalification test of 400 kV XLPE cable system

KO E.G., CHOI S.G., JEON, S.I., YANG J.S., LEE I.H., PARK W.K.; LG Cable Ltd; Korea

WOUTER J.W.M. SLOOT, PULTRUM E.; KEMA; Arnhem, The Netherlands

2003 - A2-5

Large projects of EHV underground cable systems

BJORLOW-LARSEN Kjell; Nexans;

DEL BRENNA M.; Pirelli; Italy

KAUMANNS Johannes; ABB;

MEIER R.; Brugg Kabel AG; Switzerland

KIRCHNER M.; NKT Cables;

ARGAUT P.; Sagem; France

2003 - A2-6

The development of an ultrasound quality monitoring process for the manufacture of enhanced reliability HV and EHV XLPE cables

SMITH C.; IPEC Ltd; United Kingdom

GALLOWAY S., GREGORY B., LLOYD S., NOTMAN D.; Cable ConsultingInternational Ltd; United Kingdom

2003 - A3-1

New generation of GIL. Characteristics and applications

PONCHON Ph., BUES M., GIRODET A., LORAY F.; Alstom; France

2003 - A3-2

Experience with 2nd generation gas-insulated transmission lines GIL

KOCH H.; Siemens AG; Germany

2003 - A3-3

Very fast front overvoltage computation in GIL due to switching operations with disconnectors in GIS

CRISTESCU D.; Politehnica University of Bucharest; Romania

VASILIU Z.H., MICU C.; SC Electrica SA;

NICOARA B.; Eduperco Centre, Politehnica University of Bucharest; Romania

2003 - A3-4

Development project on HTS Cables

COEVOET M.; EDF R&D; France

LADIE P.; Pirelli Cavi e Systemi Energia; Italy

2003 - A3-5

Volume effect of partial discharge inception characteristics in high temperature superconducting cable

HAYAKAWA N., KOBAYASHI T., HAZEYAMA M., OKUBO H.; Nagoya University; Japan

TAKAHASHI T.; CRIEPI; Japan

YASUDA K.; Super-GM; Japan

2003 - A3-6

V-t characteristics at PD inception for LN2 impregnated HTS cable insulation system

HAYAKAWA N., HAZEYAMA M., KOBAYASHI T., OKUBO H.; Nagoya University; Japan

TAKAHASHI T.,; CRIEPI; Japan

YASUDA K.,; Super-GM; Japan

2003 - A4-1

Critical issues for the HV & EHV XLPE cables of today and tomorrow

CAMPUS A., HAMPTON R.N., SMEDBERG A., WALD D.; Borealis AB; Sweden

BOSTROM J.O.; Borealis Compounds LCC; USA

LENNARTSON H.; Borouge Pty; Hong kong Ltd.

2003 - A4-2

400 kV cables for bulk power transmission systems

DORISON Eric; EDF R&D; France

MAUGAIN Yves; RTE; France

2003 - A4-3

New 400 kV underground cable system project in Jutland (Denmark)

MIKKELSEN S.D.; Eltra; Denmark

ARGAUT P.; Sagem; France

2003 - A4-4

Development and prequalification of large conductor VHV cable systems

MOREAU L., GAHUNGU F., DUBOIS D., SY D., MIREBEAU Pierre; Nexans; France

2003 - A4-5

BC Hydro’s experience with a novel on-line monitoring system used on a 242 kV PPLP insulated cable system

CHERUKUPALLI S., KOJIMA T., MACPHAIL A., CHORE R., STRUYK E.; BC Hydro; Canada

KUMADA Y., NAKAJIMA T.; VISCAS Corporation; Japan

2003 - A4-6

Installation of a 220 kV XLPE cable in a deep shaft for a hydroelectric power plant

A. MARINI; Enel Produzione; Italy

BISLERI Cesare, ZACCONE Ernesto; Pirelli Cavi e Sistemi Energia SpA; Italy

2003 - A5-1

Development of factory-expanded cold-shrinkable joint for EHV XLPE cables

KOBAYASHI S., MUTO D., TANAKA S., LIZUKA H.; The Furukawa Electric Co. Ltd; Japan

NIINOBE Hiroshi; Fujikura Ltd; Japan

SUETSUGU M.; VISCAS Corporation; Japan

2003 - A5-2

Space charge distribution in two-layer dielectrics

LIANG L., XIA W., DEMIN T.; Xi’an Jiaotong University; Xi’an, China

2003 - A5-3

Development of cold shrinkable joints for 110~230 kV XLPE cable

NAKAMURA S., KUWAKI A., HAYASHI K., MIKAMI M.; Exsym Corporation; Japan

2003 - A5-4

Completion of prefabricated joint for 500 kV XLPE cable

KOBASHI K.; The Kansai Electric Power Co. Inc.; Japan

BAN S.; J-Power Systems Corp.; Japan

KANAOKA M.; J-Power Systems Corp.; Japan

YONEMURA T.; The Furukawa Electric Co. Ltd; Japan

NIINOBE Hiroshi; Fujikura Ltd.; Japan

2003 - A5-5

Test methods for SiR-accessories used in high voltage cables up to 400 kV

WEISSENBERG Werner; Brugg Kabel AG; Switzerland

KUSCHEL M.; SIEMENS AG; Germany

2003 - A6-1

Super compact rubber block joint with high dielectric constant layer

NIINOBE Hiroshi, KON H., TAKAHASHI T., WATANABE A., AKIMOTO S.; Fujikura Ltd.; Japan

UMEDA S.; VISCAS Corporation; Japan

IZUKA H.; The Furukawa Electric Co. Ltd.; Japan

2003 - A6-2

Anti-explosion protection for HV porcelain & composite terminations

GAHUNGU François; Nexans; France

CARDINAELS J.; Nexans Euromold; Belgium

STREIT P., ROLLIER D.; Nexans Switerland Cossonay; Switzerland

2003 - A6-3

Microvaristor based field grading elements for HV terminations

GRAMESPACHER H.; ABB Switzerland Ltd.; Swtizerland

DONZEL L., CHRISTEN T., GREUTER F.; ABB Switzerland; Switzerland

DONZEL L., CHRISTEN T., GREUTER F.; ABB Switzerland; Switzerland

2003 - A6-4

New dry outdoor terminations for HV extruded cables

DEJEAN Pierre-Marcel; Pirelli Câbles & Systèmes; France

GOEHLICH L.; Technical University Berlin; Germany

QUAGGIA Dario, PARMIGIANI Bruno; Pirelli Cavi e Sistemi Energia; Italy

2003 - A6-5

Plug-in type connection techniques using HV-connex on encapsulated components in high-voltage equipment up to Um = 245 kV

DEISTER P.F., SCHUSTER M.; Pfisterer Kontaktsysteme; Germany

2003 - A7-1

Subsea XLPE cables

HAMPTON R.N., RYDIN C., SMEDBERG A.; Borealis AB; Sweden

2003 - A7-2

Development of 500 kV DC XLPE cable system and its pre-qualification test

MARUYAMA S., ISHII N.; The Furukawa Electric Co. Ltd; Japan

YAMANAKA T., KIMURA T.; Electric Power Development Co. Ltd; Japan

TANAKA H.; VISCAS Corporation; Japan

2003 - A7-3

Development of DC extruded cables and factory joints in Japan

YAMANAKA T., KIMURA T.; Electric Power Development Co. Ltd; Japan

MURATA Y., HIROTA H.; J-Power Systems Corp.; Japan

SHIGETOSHI I.; Fujikura Ltd.; Japan

MARUYAMA S.; The Furukawa Electric Corp.; Japan

2003 - A7-4

The Murray Link project – the first commercial 150 kV extruded HVDC cable system

WORZYK T., JEROENSE M.; ABB Power Technologies; Sweden

FARR M.; TransEnergie Australia; Australia

SÖRQVIST T.; ABB Power Technologies; Sweden

2003 - A7-5

HVDC extruded cables: testing of cable systems aiming at VSC or LCC applications

JANAH H., MATALLANA J., SY D., MIREBEAU Pierre; Nexans; France

2003 - A7-6

Energy transmission on long three core/three foil XLPE power cables

BALOG G.E., EVENSET G.; Nexans Norway AS; Norway

RUDOLFSEN F.; Norconsult AS; Norway

2003 - A8-1

Transmission power cables partial discharge detection at damped AC voltages

GULSKI Edward, WESTER F.J., SMIT J.J.; Delft University of Technology; Delft, The Netherlands

GROOT E.R.S., WESTER Ph.; Nuon; The Netherlands

SEITZ Paul P.; Seitz Instruments AG; Switzerland

2003 - A8-2

Partial discharge diagnostics as part of CMB on MV power cables: Yes or No ?

VAN SCHAIK N., STEENNIS E.F., ROSS R.; Kema T&D Testing Services; The Netherlands

KRUITHOF Marko; ENECO Energie; The Netherlands

2003 - A8-3

The Cenelec long term test for XLPE MV cables – Everything new and different ?

MEURER D., STÜRMER M.; Nexans Deutschland GmbH & Co. KG; Germany

2003 - A8-4

On-site AC testing and PD measurement of 345 kV/2500 mm2 XLPE cable systems for bulk power transmission

KAUMANNS Johannes, PLIETH E.; ABB Energiekabel GmbH; Germany

PLATH Ronald; IPH, High Voltage Lab.; Germany

2003 - A8-5

Experience with after laying test

PULTRUM E., VERHOEVEN S.A.M., VAN SCHAIK N.; Kema High Voltage Laboratory; The Netherlands

2003 - A8-6

Results of after-laying tests of 275 kV XLPE cable line

KOBAYASHI S.I., MORIMOTO N., KAWABE T., SHINODA A., SHIMOHIRO D.,KAWAI T.; Chubu Electric Power Co. Inc.; Japan

2003 - A9-1

Calculation of thermal ratings of cable systems using generalized matrix method

HIRANANDANI A.; DTE Energy; USA

2003 - A9-2

Effect of power cable installation on current rating, magnetic fields and reliability

de WILD F.H., MEIJER G.J., ROSS R.; KEMA-TDT; The Netherlands

2003 - A9-3

Ampacity program of IEC 60287 and JCS 168 E suitable for KEPCO

JEONG S.H., KIM D.K., CHOI S.B.; KERI; Korea

YOON H.H., TACK E.G.; Korea Electric Power Corporation (KEPCO); Korea

2003 - A9-4

Cable crossings

DORISON Eric; EDF R&D; France

2003 - A9-5

Determination of cable dynamic rating from distributed temperature sensing and hotspot temperature analysis

SU Qi, LI Hong-jie, TAN Kee Choon; Singapore PowerGrid; Singapore

2003 - A9-6

Cable rating using a computer analogue

LYALL J.S.; School of Electrical and Electronic Systems Engineering; Australia

2003 - B1-1

New MV cables used in France and improvements in laying techniques

DAVID J.M., MOREAU C.; EDF R&D; France

TAMBRUN R., ODDI M.; EDF DEGS DRE-MER; France

2003 - B1-2

Investigations of medium voltage polymeric cables aimed at a rationalised European standard

DAVID J.M.; EDF R&D; Moret-sur-Loing, France

PAPADOPULOS M.S.; The Electricity Association; United Kingdom

FARA A.; ENEL DDR-USA-UNI; Italy

MARCET F.; Iberdrola; Spain

BANKS V.A.A.; Pirelli Cables; United Kingdom

CENSIER B.; Pirelli; France

DIEFENBACH I.; RWE Eurotest GmbH; Germany

FONTANA M.; Pirelli Cavi; Italy

FANGAIN J.; Nexans France; France

2003 - B1-3

Measurement of the rigidity of polymeric cables

JORGENSEN H.J.; DEFU a.m.b.a.; Denmark

BENJAMINSEN J.T.; SINTEF Energy Research; Norway

NIELSEN N.H.; NKT Cables A/S; Denmark

LARSEN P.B., RYEN A.; Nexans Norway AS; Norway

ENGER S.; Draka Norsk Kabel; Norway

2003 - B1-4

Influence of some selected service conditions on properties of XLPE applied in insulated or covered overheads conductors

JANISZEWSKI S., RAKOWSKA A.; Poznan University of Technology; Poland

2003 - B1-5

New approach for MV underground connection

CHARLES F., PETRUS R., ARGAUT P.; Sagem S.A.; France

2003 - B1-6

20 years of experience with copolymer power cable insulation

CAMPUS A.; Borealis Polymers NV; Switzerland

ULRICH M.; ; Germany

2003 - B2-1

Laminate sheath power cable insulated with XLPE for flame retardant applications

BOW Kenneth E.; The Dow Chemical Company; USA

2003 - B2-2

Fire retardant mechanism intumescent EVA compositions

CAMINO G. & RIVA A.; Politechnico di Torino; Italy

AMIGOUËT P., BRAS PEREIRA P.; Nexans-NRC; France

2003 - B2-3

Compounding of flame retarded materials for the wire and cable industry

RICHARDSON Colin G.; Coperion Buss AG; Switzerland

2003 - B2-4

Study on low-smoke low-halogen and flame retardant PVC sheath composite

XIAOGANG S., XIJING C., YONGHUA Z., XIUFENG L.; Shandong Luneng Cable CO Ltd; China

2003 - B2-5

Advanced SZ-stranding technology for flexible conductors

MARIK J., ALTMANN E.; Rosendahl; Austria

2003 - B2-6

Special MV cable for long stator winding application Transrapid Shanghai

BUETHE H., LE DREN S., STEINBRINK D., ZAMZOW P. E.; Nexans Deutschland; Germany

2003 - B3-1

Decision support for condition assessment of power cables

GULSKI Edward, WESTER F.J., SMIT J.J.; Delft University of Technology; Delft, The Netherlands

DE FRIES F.; Nuon; The Netherlands

2003 - B3-2

Condition assessment of distribution PILC cables from electrical, chemical and dielectric measurements

BUCHHOLZ V., COLWELL M.; Powertech Labs Inc.; Canada

CHERUKUPALLI S.; BC Hydro; Canada

CRINE Jean Pierre; Consultant; Canada

KEEFE R.; EPRI; USA

2003 - B3-3

Influence of corroded conductors on the performance of medium voltage extruded cables

PELISSOU Serge; Hydro Québec (IREQ); Canada

COTÉ J., SAVAGE R., ST ANTOINE S.; Hydro-Québec (Distribution); Canada

2003 - B3-4

A multidiscipline 35 kV cable failure investigation

ORTON H., FURST G. & BATHO A.; Orton Consulting Engineers International Ltd; Canada

RAO A.; Powertech Labs; Canada

DE SALVIDAR C.; Conductores Monterrey; Mexico

GOMES MORANTE M.; Was with Hylsa; Mexico

2003 - B3-5

Diagnostics and maintenance of high-pressure fluid-filled paper cable

LINOIS P., ROBINOT G., ROIZARD T.; RTE; France

MEURICE D., WELSCH E.; EDF R&D; France

2003 - B4-1

Effects of sea salt sediment on 110 kV cable stations on the Croatian Adriatic coast

ALIJINOVIC S.; HEP Transmition; Croatia

2003 - B4-2

Environmental considerations for end of life disposal of cables

HELMESJÖ B.; Borealis; Sweden

HAGSTRÖM B.; IFP Research; Sweden

2003 - B4-3

Scraps recycling

BARIOZ C.; Nexans NRC; France

COSTERG T.; RIPS Nexans; France

2003 - B4-4

Innovative ways to build underground power cables and communication networks in strategic partnerships with utility pipe owners

JEYAPALAN Jey K.; Dr Jeyapalan & Associates , LLC; USA

2003 - B4-5

Environment conscious design of VHV transmission links by cable systems

MIREBEAU Pierre; Nexans France; France

ARGAUT P.; Sagem; France

DEJEAN Pierre-Marcel; Cables Pirelli; France

2003 - B5-1

New stabilizer concepts for polyethylene used in power cable applications

STRICKER F., KOLB M.; CIBA Specialty Chemicals; Switzerland

2003 - B5-2

The continuing evolution of semiconductive materials for power cable applications

LINDBOM L., NILSSON U., HAMPTON R. N., BROMAN C.,.EKLIND H.,NYLANDER P.; Borealis; Sweden

2003 - B5-3

New XLPE insulation for HV and EHV cables

CARONIA P.J., COGEN J.M.; Dow Chemical GmbH; USA

KJELLQVIST J.B.L., AARTS M.W.A.M.; Dow Europe GmbH; Switzerland

2003 - B5-4

New flexible TR-XLPE insulation for medium voltage power cables

GROSS L.H., CARONIA P.J.; Dow Chemical Company; USA

KJELLQVIST J.B.L.; Dow Europe GmbH; Switzerland

2003 - B5-5

Study on properties of rubber improved with nanomaterial used in cable

MAN X.,LIU Y. BINGLI Y., XIAOLONG C.; Xi’an Jiaotong University; China

2003 - B6-1

Survey of space charge evolution in high voltage cables submitted to AC voltage as part of the Artemis project

NOTINGHER P. jr., TOUREILLE Alain, AGNEL Serge, DIDON N.; LEM; France

CASTELLON J., MALRIEU S.; Am2e; France

2003 - B6-2

Space charge measurements and ageing evaluation in stressed cables

MONTANARI Gian Carlo; DIE-LIMAT, University of Bologna; Italy

DE ROBERTIS G., PALMIERI F.; TechImp Srl; Bologna, Italy

PEREGO G., ALBERTINI M., FRANCHI BONONI S.; Pirelli Cavi Energia SpA; Italy

2003 - B6-3

Study of AC electrical and thermal ageing of XLPE polyethylene by space charge measurements

AGNEL S., TOUREILLE A.; LEM Montpellier; France

PLATBROOD G.; Laborelec; Linkebeek, Belgium

2003 - B6-4

The influence of temperature on electrical conduction and space charge in LDPE

LAU W.S., CHEN G.; University of Southampton; UK

2003 - B6-5

The effect of voltage reversal and elevated temperature on space charge

FU M., CHEN G.; University of Southampton; UK

2003 - B6-6

Study of the effects of the temperature modulation on the lifetime of HV XLPE cables

PLATBROOD G.; Laborelec; Linkebeek, Belgium

JANAH H.; Nexans; France

CLOET E.; ELIA; Belgium

BECKER J.; Nexans; France

2003 - B7-1

Additives for the suppression of electrical treeing in polyethylene

LEEK, C., LE POIDEVIN G. J.; EA Technology; United Kingdom

TAIT P.J.T.; University of Manchester Institute of Science & Technology; United Kingdom

2003 - B7-2

Electrical aging and breakdown of crosslinked polyethylene cables

CRINE Jean Pierre; Consultant; Canada

ZENGER Walter; EPRI; USA

2003 - B7-3

Preventive diagnostic testing of high and medium voltage cables – Progress report

WEISSMUELLER G.; Technische Werke Ludwigshafen AG; Germany

ZUEHLKE L.; AVISO Netzdienste GmbH; Germany

2003 - B7-4

Electrical tests of overvoltage protection devices of H.V. cables with water penetration monitoring

GOEHLICH L., SCHAPER S., KALKNER W.; Technical University Berlin; Germany

DONAZZI F., GASPARI R.; Pirelli Cables & Systems; Italy

JAHNK V.; Lancier Monitoring GmbH; France

2003 - B7-5

Evaluation and modelling of thermo-electric ageing of XLPE insulated power cables: the ARTEMIS outcome

LAURENT C.; Laboratoire de Génie Electrique, Université P. Sabatier; France

CAMPUS A.; Borealis; Sweden

2003 - B9-1

Accelerated long term evaluation of MV-XLPE cables

BENJAMINSEN J.T., FAREMO H.; Sintef Energy; Research Norway

LARSEN P.B., A. RYEN, WOLDEN A.; Nexans Norway AS; Norway

2003 - B9-2

Assessment of cable performance as measured by a variety of accelerated ageing tests

BOSTROM J.O., MARSDEN J.O.; Borealis Compounds LCC; USA

HAMPTON N., NILSSON U.H.; Borealis AB; Sweden

2003 - B9-3

A new test method to evaluate the water treeing resistance of polymers for cable insulation

FILIPPINI C.; LEMD CNRS; France

RADU I.; LEMD; France

NOTINGHER P.; Politehnica University; Bucharest, Romania

CAMPUS A.; Borealis Polymers NV; Belgium

2003 - B9-4

Comparative evaluation by laboratory aging of 15 kV TR-XLPE & EP cables

KATZ C., FRYSZCZYN B.; CABLE TECHNOLOGY LABS; New Brunswick, NJ, USA

KEEFE R.; EPRI; USA

WALKER M.; Center Point Energy; USA

2003 - B9-5

Evaluation of tree retardant XLPE(TR-XLPE) and EPR insulated 35 kV cables after 17 years of field service

MENDELSOHN A., PERSON T.J.; The Dow Chemical Company; USA

SHATTUCK G.B.; Alabama Power; USA

HARTLEIN R.; Georgia Tech Neetrac; USA

2003 - B9-6

Investigation of electrochemical degradation in a service-aged, cable-cure restorated PE-insulated M.V. cables

BRÜGGEMANN M., KALKNER W.; Technische Universität Berlin; Germany

2003 - C10-1-1

Novel polymeric insulating compounds for HVDC applications

MENDELSOHN A., JOW J.; The Dow Chemical Company; USA

2003 - C10-1-2

Material solutions for extruded HVDC cables

NILSSON U.H., CAMPUS A., HAMPTON R.N.; Borealis AB; Sweden

BERGKVIST M., FARKAS A., JEROENSE M.; ABB Power Technology AB; Sweden

CARTENSEN P., JONSSON J., ZEBOUCHI N.; ABB Group Services Center AB; Sweden

2003 - C10-1-3

Materials for HVDC extruded cables

JANAH H., MATALLANA J., BRAME J.F., MIREBEAU Pierre; Nexans; France

OUREN S.; Nexans; Norway

2003 - C10-1-4

Effect of ageing on volume resistivity of different kinds of polyethylene cable insulation

RAKOWSKA Alexandra; Poznan University of Technology; Poland

HAJDROWSKI K.; Grupa Energetyczna ENEA S.A.; Poland

2003 - C10-1-5

Application of PPLP to DC MI cables

MITANI M., KATAKAI S., HIROTA H., MURATA Y.; J-Power Systems Corp.; Japan

HATA R.; Sumitomo Electric Industries Ltd; Japan

2003 - C10-1-6

Test of polymers for high voltage DC cables

RASMUSSEN C.N.; NKT Research A/S; Denmark

HOLBOELL J.T., HENRIKSEN M.; Technical University of Denmark; Denmark

2003 - C10-2-1

Acetylene black or other conductive carbon blacks in HV cable compounds. A historical fact or a technological requirement ?

PROBST N., GRIVEI E., VAN BELLINGEN C.; Erachem Comilog SA; Belgium

2003 - C10-2-2

Study on surface smoothness of extruded polyolefin compound contained high content of filler

XIUFENG L., XIAOGANG S., YONGHUA Z., ZHANGJIN.; Shangdong Luneng Taishan Cable Co. Ltd.; China

DARONG X.; Xi’an Jiaotong University; China

2003 - C10-2-3

Application of fifth-generation jacketing technology for improved performance

DAMMERT R.C.; Borealis AB; Sweden

KIRCHNER M., PHILIPPCZYK C.; NKT Cables; Germany

2003 - C10-2-4

Influence of the grain size on electrical and mechanical properties of non-linear materials

BAYON L., KOELBLIN C.; Nexans Research Center; France

2003 - C10-2-5

Strippable shields with improved thermal stability and faster cable extrusion rates

PANG K.P., PERSON T.J.; The Dow Chemical Company; USA

DE VOS S.V.N.; Dow Europe GmbH; Switzerland

2003 - C10-2-6

Material identity card methodology

KUNTZ M.; EDF R&D; France

GARRIGUES S.; RTE; France

2003 - C8-1-1

Use of numerical simulation to develop a new semiconductive layer for HV cables

THIZON E., POISSON B., ARGAUT P; SAGEM; France

2003 - C8-1-10

Partial discharge measurements on service aged medium voltage cables at different frequencies

VOIGT G.; University of Applied Sciences; Germany

MOHAUPT Peter; BAUR Prüf und Messtechnik; Austria

2003 - C8-1-11

An investigation on the applicability of the hybrid sensor for detecting high frequency partial discharge

KIM J.H., KOO J. Y.; Han Yang University; Korea

KIM J.T.; DaeJin University; Korea

2003 - C8-1-12

Sensitive PD detection on drained paper insulated cables

KUMM T., HEINRICH R., RETHMEIER K., JACOBSEN P., KALKNER W.; TechnicalUniversity Berlin; Germany

ZINBURG E.; GEW Rheinenergie AG; Germany

2003 - C8-1-13

Analysis of PD source locations in mixed insulated cable circuits

WESTER F.J., GROOT E.R.S.; NUON InfraCore; The Netherlands

GULSKI Edward, QUAK B., SMIT J.J.; Delft University of Technology; Delft, The Netherlands

2003 - C8-1-14

New designs for MV accessories: cold-shrinkable transition joints and evolution of separable cable connectors

CHATTERJEE Shotu, DE RIDDER E., CARDINAELS J.; Euromold Nexans; Belgium

2003 - C8-1-15

Tailor-made medium voltage cables

EFRAIMSSON L., JOHNSEN U; Ericsson Network Technologies; Energy, Sweden

2003 - C8-1-2

Design of single core cable installations exposed to short-circuit stresses

INSTANES A.; NDLO/SEA; Norway

ANDREASSEN R.; Oglaend System; Norway

KULBOTTEN H., LERVIK J.K.; SINTEF Energy Research; Norway

2003 - C8-1-3

Determination of cable dynamic rating from distributed temperature sensing and hotspot temperature analysis

SU Qi, LI Hong-jie, TAN Kee Choon; Singapore PowerGrid; Singapore

2003 - C8-1-4

Monitoring and dynamic rating of 120 kV XLPE insulated cable circuits at Hydro-Quebec

LEDUC J., BEAUCHEMIN R., CHAABAN M., CHOQUETTE M.; Hydro Québec (IREQ); Canada

2003 - C8-1-5

Real time ampacity estimation system for 345 kV transmission cable installed on tunnel

LEE S.K., NAM S.H., HONG J.Y., PARK W.K.; LG Cable; Korea

YOUN H.H.; Korea Electric Power Corporation (KEPCO); Korea

2003 - C8-1-6

Current rating of cables installed in tunnels

DORISON Eric, DE KEPPER B.; EDF R&D; France

PROTAT F., GURKAHRAMAN A., MASURE L.; SUPELEC; Gif sur Yvette, France

2003 - C8-1-7

On-site follow up of the characteristics of controlled backfill, using the TDR moisture-measurement method

GILLE A.; BEL Engineering; Belgium

GEERTS G.; ELIA; Belgium

XANTHOULIS D., FONDER N.; Agricultural University of Gembloux; Belgium

MELLA J.-P.; Nexans Benelux; Belgium

2003 - C8-1-8

Early detection of electrical tree through advanced PD measurement inference techniques

CAVALLINI A., CONTI M., MONTANARI G.C.; DIE, University of Bologna; Italy

PULETTI F.; TechImp; Italy

CONTIN A.; DEEI; University of Trieste, Italy

GUASTAVINO F.; DE; University of Genova, Italy

OMBELLO F.; Pirelli Cavi Energia SpA; Italy

2003 - C8-1-9

Detection of partial discharges in HV terminations using a capacitive sensor

HVIDSTEN S., LUNDGAARD L.; SINTEF Energy Research; Norway

2003 - C8-2-1

Modification of cable replacement criterion of isothermal relaxation current measurement system

KIM J.Y., SONG. I.K., HAN M.G.; Korea Electric Power Institute (KEPRI); Korea

YI Dong Young; Uiduk University; Korea

2003 - C8-2-2

Applications to cable diagnosis of new methodology for partial discharge inference

CAVALLINI A., FABIANI D., MONTANARI G.C.; DIE-LIMAT, University of Bologna; Italy

OMBELLO F., FRANCHI BONONI F.; Pirelli Cavi e Sistemi SpA; Italy

2003 - C8-2-3

Change with time in PD characteristics of a void in the semicon/polyethylene interface

KIM C.S., MIZUTANI T.; Nagoya University; Japan

KOBAYASHI S., MORIMOTO N., TSUJI S., SAITOU H.; Chubu Electric Power Co.; Nagoya, Japan

2003 - C8-2-4

Aspects and implications of on-line PD detection and localization of MV cable systems

STEENNIS Evert Frederik; Kema High Voltage Laboratory; The Netherlands

VAN DER WIELEN.P.C.J.M., VEEN J. WOUTERS P.A.A.F; Eindhoven University of Technology; The Netherlands

2003 - C8-2-5

Inductive directional couplers as new sensors for PD detection and localization on high voltage XLPE cable accessories

HEINRICH R.; Schaffner EMC-Systems GmbH; Germany

RETHMEIER K., KALKNER W.; Technical University Berlin; Germany

2003 - C8-2-6

Sensitive PD detection on high voltage XLPE cable lines using field coupling sensors

HEINRICH R.; Schaffner EMC-Systems GmbH; Germany

RETHMEIER K., KALKNER W.; Technical University Berlin; Germany

PLATH Ronald; IPH, High Voltage Lab.; Germany

WEISSENBERG Werner; Brugg Kabel AG;

2003 - C8-2-7

The analysis of the partial discharge pattern to the artificial defects introduced at the interface in an XLPE cable joint using laboratory model

LEE J.S., KIM J.T.; LG Cable. Ltd.; Korea

KOO J.Y.; Hanyang University; Korea

KIM J.T.; Daejin Univ.; Korea

2003 - C8-2-8

Application of damped AC voltages for PD diagnosis of distribution power cables

WESTER F.J.; NUNON InfraCore; The Netherlands

GULSKI Edward; Delft University of Technology; Delft, The Netherlands

SCHIKARSKI P.; Haefely Test AF; Switzerland

SEITZ Paul P.; Seitz Instruments AG; Switzerland

2003 - C8-2-9

Optimised cable end termination systems for laboratory tests on MV, HV and EHV

SCHIERIG S., PIETSCH, KUBAT M.; Highvolt Prüftechnik Dresden GmbH; Germany

2003 - C8-3-1

Microspectral analysis in UV-vis range as a tool for power cable insulation diagnosis

SHUVALOV Mikhail, OVSIENKO Vladimir, KORSAKOVA M.; All-Russian Cable R&D Institute; Russia

2003 - C8-3-10

Influence of electrochemical effects on vented tree initiation in accelerated tests

BRÜGGEMANN M., KALKNER W.; Technische Universität Berlin; Germany

BROMAN C., SMEDBERG A.; Borealis AB; Sweden

2003 - C8-3-2

Actual application of on-site diagnostic method for water treed XLPE cable by harmonics in AC loss current

TANAKA A., TOYA A., TSUJIMOTO T., NAKADE M.; Tokyo Electric Power Company; Japan

YAGI Y., ADACHI K.; The Furukawa Electric Co. Ltd.; Japan

TANAKA H.; VISCAS Corporation; Japan

2003 - C8-3-3

Condition assessment of triple extruded MV XLPE cables

BENJAMINSEN J.T., HVIDSTEN S.; SINTEF Energy Research; Norway

2003 - C8-3-4

On-site TSM measurements on HV cable loops as part of the Artemis project

CASTELLON J., MALRIEU S.; Am2e; France

NOTINGHER P. jr., TOUREILLE Alain; LEM; France

BECKER J.; Nexans; Belgium

DEJEAN Pierre-Marcel; Câbles Pirelli; France

JANAH H., MATALLANA J.; Nexans; France

VERITE J.C.; EDF R&D; France

2003 - C8-3-5

Diagnostic method for water tree aging XLPE cable with residual charge measurement

TOYA A., TANAKA A.; Tokyo Electric Power Company; Japan

OOTAKA I.; EXSYM Corporation; Japan

SAKAMOTO T.; Mitsubishi Cable Industries Ltd.; Japan

2003 - C8-3-6

The improved residual-charge measurement to diagnose the water-tree deteriorated power cable

KON H.; Fujikura Ltd; Japan

MIYAJIMA K., UCHIDA K.; Chubu Electric Co.; Japan

WATANABE K.; VISCAS Corporation; Japan

2003 - C8-3-7

The Raman spectroscopy analysis of electrically aged polyethylene

CHEN G., VAUGHAN A.S.; University of Southampton; UK

LIU X.Z.; Xian Jiaotong University; China

2003 - C8-3-8

Diagnostic of field aged cables and accessories by time-domain dielectric spectroscopy (TDDS)

AMYOT N., FOURNIER D., DRAPEAU J.F.; IREQ; Varennes Québec, Canada

DAVID E.; Ecole de Technologie Supérieure; Québec, Canada

2003 - C8-3-9

An analysis of the water treeing resistance of polymer compounds for cable insulation using the two needles method

TEISSEDRE G., FILIPPINI J.C.; LEMD; CNRS, France

NYLANDER P.; Borealis AB; Sweden

CAMPUS A.; Borealis polymers; Belgium

2007 - A10-1

Comparison of different analytical test methods to monitor crosslinking by-products in XLPE insulated cables

SMEDBERG Annika, BOSTRÖM Jan-Ove; BOREALIS AB; Stenungsund, Sweden

WALD Detlef, PETERS Rudi; BOREALIS Polymers NV; Mechelen, Belgium

2007 - A10-2

Breakdown caused by abrupt DC-Voltage grounding of XLPE cable insulation

IIDSTAD Erling, MAUSETH Frank; Norwegian University of Sc.and Tech. (NTNU); Trondheim, Norway

SELSJORD Mildrid, HEGERBERG Rolf; SINTEF Energy Research; Trondheim, Norway

SANDEN Bjørn; NEXANS Norway AS; Oslo, Norway

JEROENSE Marc; ABB Power Systems; Karlskrona, Sweden

LARSEN Jan Erik; Stattnett SF; Oslo, Norway

2007 - A10-3

New approach to measure conductor temperature during type test

PULTRUM Edwin, SLOOT Wouter, VERHOEVEN S.A.M.; KEMA; Arnhem, The Netherlands

2007 - A10-4

After-installation testing of HV/EHV extruded cable systems – procedures and experiences

HERRMANN Ulrich, KLUGE Andreas, PLATH Ronald; IPH; Berlin, Germany

2007 - A10-5

HV AC testing of super-long cables

SCHIERIG Stefan, COORS Peter; TU Dresden; Dresden, Germany

HAUSCHILD Wofgang; IEC, CIGRE, TU Dresden; Germany

2007 - A10-6

Type testing of a 13.2 kV, 69 MVA TRIAX HTS cable

WILLEN Dag, TRAEHOLT Chresten, THIDEMANN Carsten; nkt cables; Brondby, Denmark

JINDSAY David T, RODEN Mark, TOLBERT Jerry; Southwire Company; USA

2007 - A1-1

Development of 400 kV XLPE cable and accessories

KUWAKI Akihisa, HAYASHI Katsuyuki; XSYM Corp.; Saitama, Japan

KATO Kenji; EXSYM Corp,, Mito; Aichi, Japan

IMAI Noriaki; EXSYM Corp, Sagamihara; Kanagawa, Japan

2007 - A1-2

400 kV XLPE insulated cable systems with dry plug-in outdoor terminations

KAUMANNS Johannes, SCHRÖDER Gero, LEHNHÄUSER Jürgen, STROOT Volker, WEINLEIN Andreas; Südkabel; Mannheim, Germany

2007 - A1-3

Development of one piece type joint (self pressurized joint) for 400 kV XLPE cable

FUDAMOTO Koji, WATANABE Yoichi, KISHI Koji, UOZUMI Tsuyoshi, TERAYAMA Atsushi; J-Power Systems Corp.; Osaka, Japan

2007 - A1-4

French experience in aluminium laminated screens

LESUR Frédéric; EDF R&D; Moret-sur-Loing, France

ARGAUT Pierre; SILEC CABLE; Montereau, France

BENARD Laurent; PRYSMIAN; Paron, France

MIREBEAU Pierre; NEXANS France; Calais, France

2007 - A1-5

Development of the high voltage extruded cables: Italian experience

FARA Antonio; ENEL,; Rome, Italy

ZACCONE Ernesto; PRYSMIAN Cables & Systems; Milano, Italy

2007 - A1-6

400 kV 2500mm² XLPE cable system prequalification and type test for Middle East environment

MATALLANA Jérôme, GARHUNGU François, DUVIVIER Martine, DUBOIS David, MIREBEAU Pierre; NEXANS France; Calais, France

2007 - A2-1

Large projects of EHV underground cable systems

ARGAUT Pierre; SILEC CABLE; Montereau, France

BJORLOW-LARSEN Kjell; NEXANS Norway AS; Oslo, Norway

ZACCONE Ernesto; PRYSMIAN Cables & Systems; Milano, Italy

GUSTAFSSON Anders; ABB; Sweden

SHELL Fabian; Brugg Kabel; Germany

WACHT Wolker; NKT Cables; Germany

2007 - A2-2

The St. John's Wood - Elstree experience: testing a 20 km long 400 kV XLPE-insulated cable system after installation

SUTTON Simon; National Grid; Warwick, UK

PLATH Ronald; IPH, High Voltage Lab.; Berlin, Germany

SCHRÖDER Gero; Südkabel; Mannheim, Germany

2007 - A2-3

New 345 kV underground extruded cable system project in Connecticut

ARGAUT Pierre, LUTON Marie-Hélène; SILEC CABLE; Montereau, France

LANNING John; New River Electrical Corp; Cloverdale, USA

MOSIER Rachel; Power Delivery Consultants; Ballston Lake, NY, USA

TIRINZONI Peter; Northeast Utilities; Hartford, USA

2007 - A2-4

The 33 km long 87/150 (170) kV Koksijde-Slijkens link

LIEMANS Didier, LEROY Yves; NEXANS Benelux; Charleroi, Belgium

GAHUNGU François; NEXANS France; Calais, France

GILLE Alain; BEL Engineering; Belgium

MAMPAEY Bart; Elia; Belgium

2007 - A2-5

Undergrounding and reorganization of the electrical system of the city of Madrid

ORELLA Josu, BARRIOCANAL Mikel, ALONSO Roberto Cabero; Iberdrola Ingeniería y Construcción; Erandio, Spain

2007 - A2-6

HV power cables installed in multi-purpose tunnels, a challengeable option!

BOONE Wim, DE WILD Frank H.; KEMA Consulting; Arnhem, The Netherlands

2007 - A3-1

Superconducting cables - status and applications

SAUGRAIN Jean-Maxime; NEXANS France; Clichy, France

SCHMIDT Frank; NEXANS GmbH&Co.KG; Hannover, Germany

MIREBEAU Pierre; NEXANS France; Calais, France

2007 - A3-2

Installation and commissioning of TRIAX HTS cable

JINDSAY David T., RODEN Mark, DENMON Randy; Southwire Company; Carrollton, USA

WILLEN Dag; nkt cables; Denmark

MEHRABAN Ben,KERI Albert; American Electric Power; USA

2007 - A3-3

Installing a long-distance HTS cable

Alex Geschiere, Erika Piga; Nuon; Duiven, The Netherlands

WILLEN Dag; nkt cables; Brondby, Denmark

BARENDREGT Peter; nkt cables; Köln, Germany

ALBAUGH Kevin; Praxair; Danbury, USA

2007 - A3-4

Development and demonstration of a long length transmission voltage cold dielectric superconducting cable to operate in the Long Island Power Authority grid

SCHMIDT Frank; NEXANS GmbH&Co.KG; Hannover, Germany

MAGUIRE James; American Superconductor; Westborough, USA

BRATT Shawn; AIR LIQUIDE DTA; Sassenage, France

WELSH Tom; Long Island Power Authority; Hicksville, USA

LALLOUET Nicolas; NEXANS France; Calais, France

2007 - A3-5

Potential of multilayer coating for gas insulated dielectric withstand improvement

HAIROUR Mounir, BESSEDE Jean-Luc; AREVA T&D; Villeurbanne, France

MIKES Endre; AREVA T&D AG;

TOUREILLE Alain, AGNEL Serge, NOTINGHER Petru, CASTELLON Jerôme;; IES-GEM UM2; France

2007 - A3-6

Gas insulated transmission lines – underground power transmission achieving a maximum of operational safety and reliability

KUNZE Dirk, PÖHLER Stephan, ALTER Joachim; SIEMENS AG; Erlangen, Germany

BINDER Erich, TÜRK Jürgen; VERBUND Austrian Hydro Power; Salzburg, Austria

2007 - A4-1

Permanent on-line monitoring of MV power cables based on partial discharge detection and localisation - an update

STEENNIS Fred, Van DER WIELEN Peter, KAPTEIN Bartjan; KEMA-TDT; Arnhem, The Netherlands

HARMSEN Denny; CONTINUON; The Netherlands

KRUITHOF Marko; ENECO; The Netherlands

POSTMA André; ESSENT; The Netherlands

2007 - A4-2

On-site VHF partial discharge detection on power cable accessories

MEIJER Sander, JONGEN Rogier A., SMIT Johan J.; Delft University of Technology; Delft, The Netherlands

SEITZ Paul P.; Seitz Instruments AG; Niederrohrdorf, Switzerland

HERMANS Theo J.W.H., LAMBALLAIS Lawrence; PRYSMIAN C&S; Delft, The Netherlands

2007 - A4-3

Continuous on-line monitoring of PDS in HV cables

ZHANG Hao, PHUNG Toan, LIU Zhao, BLACKBURN Trevor; University of New South Wales; Sydney, Australia

2007 - A4-4

Partial discharge detection in power cables: practical limits as a function of cable length

CAVALLINI Andrea, MONTANARI Gian Carlo; University of Bologna; Italy

SUBRAMANIAM Chandrasekar; DEEE Sona College of Technology,; Tamilnadu, India

2007 - A4-6

New approach for high voltage cable on-site testing

BERGMANN Volker, KALKNER Wilfried; Technische Universitaet Berlin; Germany

MOHAUPT Peter; BAUR Prüf und Messtechnik; Sulz, Austria

2007 - A5-1

US experience on condition assessment of various types of taped cable systems by dissolved gas analysis based on a novel sampling and analysis technique

SINGH Nirmal, SINGH Sandeep K., REYES Rommy R., MOREL Oscar E.; Detroit Edison Company; Detroit, USA

ZENGER Walter; Pacific Gas & Electric; California, USA

2007 - A5-2

Remarkable tan delta suppression of oil filled cable insulation with extremely degraded tan delta oil

TAKAHASHI Tohru, NAKAJIMA Takenori; VISCAS Corporation; Ichihara, Japan

NAKADE Masahiko, IDE Kenichi; Tokyo Electric Power Company; Yokohama, Japan

2007 - A5-4

Diagnostic for paper cable condition assessment

ESPILIT Thierry, ZORZI Fabrice, REGAUDIE Vanessa, GAUDIN Christophe; EDF R&D; Moret-sur-Loing, France

TAMBRUN Roger; EDF DRE; Paris, France

2007 - A5-5

Application of optical fiber current sensors to underground cables

NASUKAWA Shinsuke, KONDO Reishi, KUROSAWA Kiyoshi; Tokyo Electric Power CO.; Tokyo, Japan

YAMAGUCHI Tatsushi; Toko Electric Corporation; Japan

AMANO Kazuo; Fujikura Ltd; Tokyo, Japan

YAMADA Toshiharu; Takaoka Electric MFG. Co; Tokyo, Japan

2007 - A5-6

Thermal transient analysis of underground cables

DESMET Jan, PUTMAN Dries, VANALME Greet; Hogeschool West-Vlaanderen; Kortrijk, Belgium

BELMANS Ronnie; K.U.Leuven; Belgium

CLOET Eric; ELIA,; Brussel, Belgium

2007 - A6-1

FACTS for optimum utilisation of cable networks in power systems

GRÜNBAUM Rolf; ABB Power Technologies AB; Vasteras, Sweden

KARLSTRAND Johan; ABB Power Systems; Karlskrona, Sweden

2007 - A6-2

Outsourcing preventive maintenance on underground power transmission cables

ALSHIBANI Salem M.; Cable Maintenance Section Head, Ministry of Energy; Yarmouk, Kuwait

SHARAF Ahmad; Senior Consulting Cable Engineer, Ministry of Energy; Yarmouk, Kuwait

2007 - A6-3

Failure prediction in 50 kV mass-insulated power cable systems

JONGEN Rogier A., MORSHUIS Peter H. F., SMIT Johan J.; Delft University of Technology; Delft, The Netherlands

JANSSEN Anton L.J.; Continuon Assetmanagement; Arnhem, The Netherlands

GULSKI Edward; Ksandr; Delft, The Netherlands

2007 - A6-4

Fire hazard of MV / HV cables installed in tunnels

PHILIPPCZYK Christian; NKT Cables GmbH; Köln, Germany

VENO-POULSEN Keld; NKT Cables A/S; Asneas, Denmark

JOURNEAUX Terry, GRACIAS Doug; PRYSMIAN Cables & Systems; Eastleigh, United Kingdom

LOYENS Wendy; BOREALIS AB; Stenungsund, Sweden

ROBINSON James; BOREALIS Polymers NV; Mechelen, Belgium

2007 - A6-5

Dynamic rating systems in general and in a hybrid 150 kV transmission system

DE WILD Frank H., BOONE Wim; KEMA Consulting; Arnhem, The Netherlands

Van DER GEEST Hans; CONTINUON; The Netherlands

SMIT Jacco; Nuon Tecno; Alkmaar, The Netherlands

2007 - A7-1

Sensitivity assessment for partial discharge measurements on solid dielectric transmission cables

SEDDING Howard, FENGER Mark; Kinectrics Inc.; Toronto, Canada

2007 - A7-2

On-line location of partial discharges in an electrical accessory of an underground power distribution network

LEONARD François, CANTIN Bruno; IREQ; Varennes Québec, Canada

FOURNIER Daniel; Hydro-Québec V-P Distribution; Montreal, Canada

2007 - A7-3

UHF-PD-monitoring and on-site-commissioning-test of 400 kV XLPE-insulated cable circuits at Jebel Ali / Dubai

WEISSENBERG Werner, WUNDERLIN Tony, SEKULA Oldrich; Brugg Kabel AG; Switzerland

STREHL Thomas, ELZE Heindrik, MARKALOUS Sacha; LEMKE DIAGNOSTICS; Germany

2007 - A7-4

Experience with PD measurements and commissioning tests

PULTRUM Edwin, KEISER Hans-Erik; KEMA; Arnhem, The Netherlands

2007 - A7-5

Practical issues regarding the use of dielectric measurements to diagnose the service health of MV cables

HERNANDEZ Jean C., HAMPTON Nigel, HARLEY Ronald, HARTLEIN Richard; NEETRAC, Georgia Institute; Atlanta, USA

2007 - A7-6

Evolution of space charge and internal electric field distributions in HVDC cable under long term testing

MATALLANA Jérôme, JANAH Hakim, MIREBEAU Pierre; NEXANS France,; Calais, France

SANDEN Bjørn; NEXANS Norway AS; Oslo, Norway

CASTELLON Jérôme, AGNEL Serge, NOTINGHER Petru jr, TOUREILLE Alain; LEM, Université de Montpellier; France

2007 - A8-1

Making remaining life predictions for power cables using reliability analyses

JEYAPALAN Jey K.; Dr Jeyapalan & Associates; New Milford, CT, USA

2007 - A8-2

Oil replacement by water in obsolete oil-filled power cables

DARDEL Boris, MATTMANN John-Peter, JAQUENOD Laurent, VAN RYSSELBERGHE Laurent, GEHRET Sébastien, KRÄHENBÜHL Francis; NEXANS Switzerland; Cortaillod, Switzerland

2007 - A8-3

Environmental impacts in rural area of a HV underground link

GOURIT Laurent, SERRES Etienne, CHEVALIER Peggy; RTE, National Centre for Grid Expertise; Paris, France

2007 - A8-4

Passive loops technique for electromagnetic fields mitigation: applications and theoretical considerations.

MAIOLI Paolo, ZACCONE Ernesto; PRYSMIAN Cables & Systems; Milano, Italy

2007 - A8-5

Use of an Ecoconception Software to design a HV Cable Connection

MIREBEAU Pierre, DUVIVIER Martine; NEXANS France; Calais, France

BENARD Laurent, LEBOURDON François;PRYSMIAN; Paron, France

POILLEAUX Francis, POISSON Bernard; SILEC CABLE; Montereau, France

2007 - A8-6

Ecoconception, recycling and life cycle analysis in cable industry

BARBEAU Sophie, GOUDEAU Jacques; NEXANS Research Center; Lyon, France

DUPONT Isabelle; RIPS; Calais, France

DAMILO Serge; Nexans Mehun; France

2007 - A9-1

Challenges of the second submarine interconnection between Spain and Morocco

GRANADINO Ramon, PRIETO Juan, DENCHE Gregorio; Red Electrica de España; Madrid, Spain

MANSOURI Fatima; Office National de L'Electricité, Casablanca (ONE); Morocco

STENSETH Knut; NEXANS Norway AS; Oslo, Norway

COMELLINI Roberto; PRYSMIAN Cables & Systems; Milano, Italy

2007 - A9-2

Electrical and thermal design of umbilical cable

SHACKLETON Derek; Oceaneering Multiflex; Rosyth, UK

ABIB Luciana, BALENA Rosianita; Marine Production Systems do Brasil; Rio de Janeiro, Brazil

2007 - A9-3

Qualification, supply and installation of the world's first 420 kV XLPE submarine cable system in Norway

EVENSET Gunnar, KNUTSEN Bjørn; NEXANS Norway AS; Oslo, Norway

LARSEN Jan Erik, FAUDSTAD Kirsten; Stattnett SF; Oslo, Norway

2007 - A9-4

Advances in chemical rejuvenation of submarine cables

BERTINI Glen J.; Novinium Inc.; Kent, USA

2007 - A9-5

Subsea connections to high capacity offshore windfarms: issues to consider

SVOMA Roman, DICKINSON Mark, BROWN Craig; PowerSure Technology, Bexleyheath; London, UK

2007 - A9-6

Application of temperature sensing and dynamic strain monitoring to subsea cable technology

KLUTH Richard, SINGH Kuljit; Sensornet, Elstree; Hertfordshire, UK

SVOMA Roman; PowerSure Technology, Bexleyheath; London, UK

2007 - B10-1

Challenges and opportunities when installing HV cable in Australia and Sri Lanka

RAHMAN Naveed, BARBER Ken; Olex Australia; Tottenham, Australia

2007 - B10-2

Aluminium conductors in anti-robbery cables

ROSA Luiz Henrique, DE PAULA João Alves, UEDA Sidnei; NEXANS Brasil; São Paulo, Brazil

2007 - B10-3

Design of a 45 circuit duct bank

COATES Mark; ERA Technology Ltd; Leatherhead, Surrey, UK

O'SULLIVAN Liam G.; EDF Energy Networks; Bexleyheath, Kent, UK

2007 - B10-6

Barrier optimization algorithm applied to calculation of optimal loading of dissimilar cables in one trench

MOUTASSAM Wael; University of Toronto; Canada

ANDERS George J.; Kinectrics Inc.; Toronto, Canada

2007 - B1-1

Investigation of the aging characteristics of CST termination made of silicone rubber at contamination area

NAKAMURA Tatsuya, KOZASA Yoshihide, SATO Akiyoshi, KONDOH Taikichi; Chubu Electric Power Co.; Nagoya, Japan

2007 - B1-2

Evaluation of a replacement strategy of a medium voltage cable joint based on statistical failure analysis

JONGEN Rogier A., MORSHUIS Peter H.F., SMIT Johan J.; Delft University ofTechnology; Delft, The Netherlands

JANSSEN Anton; CONTINUON Assetmanagement; Arnhem, The Netherlands

GULSKI Edward; Ksandr; Delft, The Netherlands

2007 - B1-4

Emergency conditions applied to triplex medium-voltage XLPE cables having flat strap neutrals

PELISSOU Serge; IREQ; Varennes Québec, Canada

CÔTE Jacques, ST-ANTOINE Serge, DALLAIRE Julien; Réseau de Distribution, Hydro-Québec; Montréal, Canada

2007 - B1-5

A new specification to check cable sheath resistance to termites

BRUMENT Yves, LESUR Frédéric; EDF R&D; Moret-sur-Loing, France

PAULMIER Ivan; Centre Technique du Bois et de l'Ameublement; France

2007 - B2-1

New high performance, environmentally friendly MV power cable insulations

EASTER Mark; General Cable; Indianapolis, USA

CASALS Elisenda; General Cable; Manlleu, Spain

AZPIAZU Luciano, MAIZ Gonzalo; Iberdrola Distribucion Elactrica; Bilbao, Spain

2007 - B2-2

New concept in cables and accessories for low voltage underground distribution in Spain

CALVERAS Daniel; General Cable; Spain

AZPIAZU Luciano, MAIZ Gonzalo; Iberdrola, Bilbao; Spain

RIERA Joaquim; Niled; Manresa, Spain

2007 - B2-3

Corrosion kinetics of LV cable galvanised steel screen and solid aluminium neutral

BRUMENT Yves; EDF R&D; Moret-sur-Loing, France

GIFFARD Philippe; Draka Paricable France; France

BEUCHER Eric; CRITT Haute Normandie; France

2007 - B2-4

A new customized pulling-cable software

TARNOWSLI Janislaw, IORDANESCU Mircea, VALIQUETTE Denis, RATEL Gilles; IREQ; Varennes Québec, Canada

BERGERON François, TRINH Minh; Hydro-Québec; Canada

2007 - B2-5

Service experiences for MV cable network – optimistic or pessimistic state of the art?

RAKOWSKA Aleksandra; Poznan University of Technology; Poznan, Poland

2007 - B2-6

Harmonising MV cables: Results of the European project EUROMVCABLE

DAVID Jean-Marie, REGAUDIE Vanessa, LESUR Frédéric; EDF R&D; Moret-sur-Loing, France

FARA Antonio; ENEL; Italy

SIMEON Eric; Nexans; France

BENARD Laurent; PRYSMIAN; France

DIEFENBACH Ingo; RWE; Germany

2007 - B3-1

Irradiation technologies and compounds for cables cross-linking – developments for flat and heat-trace cables

ROUIF Sophie; IONISOS; Dagneux, France

2007 - B3-2

Evaluation of a Replacement Strategy of a Medium Voltage Cable Joint Based on Statistical Failure Analysis

JONGEN Rogier A., MORSHUIS Peter H.F., SMIT Johan J.; Delft University ofTechnology; Delft, The Netherlands

JANSSEN Anton L.J.; CONTINUON Assetmanagement; Arnhem, The Netherlands

GULSKI Edward; Ksandr; Delft, The Netherlands

2007 - B3-3

Utilisation of ceramizing materials in fire resisting cables and accessories

WEIDER Bruno; NEXANS Schweiz AG; Breitenbach, Switzerland

2007 - B3-4

Ceramifying insulation materials for fire safety cables

ALEXANDER Graeme, BARBER Kenneth, LEE Dong Churl; Olex Australia; Tottenham, Australia

MARNEY Donovan; CSIRO; Australia

2007 - B3-5

Choices of flame retardant materials for cables with improved behaviour in fire

DUPHIL Dominique, POISSON Bernard, ARGAUT Pierre; SILEC CABLE; Montereau, France

BARBETA Javier, PASCUAL M. Carmen, MARTINEZ Juan D.; General Cable Sistemas; Manlleu, Spain

2007 - B3-6

Use of nanofillers in high performance of MV cables under fire conditions.

GRABOLOSA Jordi, CALVERAS Daniel; General Cable Sistemas,; Manlleu, Spain

CANEROT Isabelle; SILEC CABLE; Montereau, France

2007 - B3-7

Polymeric armour design of an improved protection to mechanical stresses and fluids for Oil Gas and Petrochem (OGP) applications

CINQUEMANI Paul; PRYSMIAN Cables and Systems; USA

DE RAI Luca, FRIGERIO Marco; PRYSMIAN Cables & Systems; Milano, Italy

VEGETTI Paolo; PRYSMIAN Cables & Systems Oy; Finland

2007 - B4-1

Health index

DORISON Eric, LESUR Frédéric, MEURICE Dominique; EDF R&D; Moret-sur-Loing, France

ROINEL Giao; RTE; France

2007 - B4-2

Evaluation of the condition and the performance of underground fluid filled HV links at Hydro-Québec

ROYER Christian, AWAD Ray; Hydro-Québec; Montreal, Canada

2007 - B4-3

Upgrading and uprating of underground existing systems

LESUR Frédéric; EDF R&D; Moret-sur-Loing, France

2007 - B4-4

Renewal works of underground transmission system in KEPCO

FUJIWARA Eiji, HAYASHIDA Takeshi, MATSUMURA Masao; The Kansai Electric Power Co. Inc.; Japan

2007 - B4-5

Re-evaluation of 150 kV cable capacity

VAN HOUWELINGEN Dirk; ENECO-Netbeheer; Rotterdam, The Netherlands

VAN ROSSUM Jos; PRYSMIAN C&S; The Netherlands

2007 - B4-6

Modern cable systems in steel pipes - new designed XLPE-insulated cables substituting paper-insulated pipe-type cables

AUE Volker, ROSEBROCK Wilfried; NEXANS GmbH&Co.KG; Hannover, Germany

2007 - B4-7

Increased voltage for the HVDC light product range – a complete solution

JEROENSE Marc, BERGKVIST Mikael, GUSTAFSSON Anders; VERBUND Austrian Hydro Power; Karlskrona, Sweden

RAPP Hans, SÖRQVIST Torbjörn, SVAHN Jörgen; ABB Power Products, Alingsås; Alingsås, Sweden

2007 - B6-2

Nuclear cables and lifetime simulation

MONCHY-LEROY Carole; EDF R&D; Moret-sur-Loing, France

THEROND Patrice; EDF SEPTEN; Villeurbanne, France

2007 - B6-3

Time Domain Spectroscopy (TDS) as a diagnostic tool for MV XLPE underground lines

DRAPEAU Jean-François, JEAN Daniel, PARPAL Jean-Luc, POTVIN Carl, LALANCETTE Daniel, L'ÉCUYER Richard; IREQ; Varennes Québec, Canada

BERNIER Simon; Ecole de Technologie Supérieure (ETS); Canada

MAGNAN Yves; Hydro-Québec; Montmorency, Canada

2007 - B6-5

Development of an innovative residual-charge measurement technique for water-tree deteriorated XLPE cable

KON Hiroyuki, TANAKA Hideo; VISCAS Corporation; Ichihara, Japan

TSUKAMOTO Toyoshi, SATO Hideaki, ONUKI Koichi; Tokyo Electric Power CO,; Tokyo, Japan

2007 - B6-6

Validating cable diagnostic tests

BEGOVIC Miroslav, PERKEL Joshua; School of ECE, Georgia Institute,; USA

HAMPTON Nigel, HARTLEIN Richard; NEETRAC, Georgia Institute; Atlanta, USA

2007 - B7-1

Development of extruded single core cables for deep waters

BERGKVIST Mikael, HANSSON Ola, JEROENSE Marc, SONESSON Claes; ABB Power Systems; Karlskrona, Sweden

2007 - B7-2

The Norned HVDC link – cable design and performance

WORZYK Thomas, SJÖBERG Mats; ABB Power Systems; Karlskrona, Sweden

SKOG Jan-Erik; Statnett; Oslo, Norway

KOREMAN Kees; Tenne T; Arnhem, The Netherlands

2007 - B7-3

Development of DC +/- 250 kV coaxially-integrated return conductor extruded cable

HIRANO Seishi, HARAGUCHI Junichi;Electric Power Development; Tokyo, Japan

MIZUNO Takehiko; VISCAS Corporation; Ichihara, Japan

NAGOYA Yoshihisa; VISCAS Corporation; Tokyo, Japan

2007 - B7-4

Effect of semicon-insulation interface on space charge formation in HVDC polymeric cables

FABIANI Davide, MONTANARI Gian Carlo; DIE-LIMAT University of Bologna; Italy

DISSADO Leonard A.; Dept. of Engineering, University of Leicester; Leicester, UK

LAURENT Christian, TEYSSEDRE Gilbert; Université Paul Sabatier-Laplace; Toulouse, France

MORSHUIS Peter H. F., BODEGA Riccardo; Delft University of Technology; Delft, The Netherlands

CAMPUS Alfred, NILSSON Ulf H.; BOREALIS AB; Stenungsund, Sweden

2007 - B7-5

Measurement and modelling of space charge accumulation in polymeric HVDC cable systems

BODEGA Riccardo; PRYSMIAN C&S; Delft, The Netherlands

MORSHUIS Peter H. F.; Delft University of Technology; Delft, The Netherlands

PEREGO Gabriele; PRYSMIAN Cables & Systems; Milano, Italy

2007 - B7-6

The use of model cables for evaluation of DC electrical properties of polymeric cable materials

NILSSON Ulf H., CAMPUS Alfred; BOREALIS AB; Stenungsund, Sweden

MONTANARI Gian Carlo; University of Bologna; Italy

MORSHUIS Peter H. F.; Delft University of Technology; Delft, The Netherlands

2007 - B8-1

The use of insulated wires Milliken conductors in high voltage power transmission underground AC lines

David Dubois, Pierre Mirebeau; NEXANS France; Calais, France

2007 - B8-2

Thermal and electromagnetic modelling of power umbilicals

HENRIKSEN Thor, LERVIK Jens K.; SINTEF Energy Research; Trondheim, Norway

NORMANN Truls; Aker Kvaerner Subsea; Lysaker, Norway

2007 - B8-4

Current rating of cables installed in plastic ducts

MOREAU Christophe; EDF R&D; Moret sur Loing, France

COURSET Ludovic; RTE CNER; Paris France

2007 - B8-5

Verification of mechanical support for cables used on bridge structures at dilation point

ROUILLARD Vincent; Victoria University; Melbourne, Australia

PIECHOTA Roman, BARNEWALL Graeme, BARBER Ken; Olex Australia; Tottenham, Australia

2007 - B8-6

Measurements of thrust load in cable systems semi-rigidly installed in duct / manhole structures

BODEGA Riccardo, GEENE Henk T. F., VAN ROSSUM Joss C. M.; PRYSMIAN C&S; Delft, The Netherlands

FRENTZAS Frank, DE ANGELIS Angelo; ComEd Chicago; Chicago, USA

KELLEY Nathan; PRYSMIAN Power Cables and Systems; USA

2007 - B9-1

Sensitivity of PD inception to change of electrical design in polymeric insulated power cable systems

VAN DER WIELEN Peter, VAN SCHAIK Nico; KEMA-TDT; Arnhem, The Netherlands

TCZASZEJKO Tadeusz; Monash University; Clayton, Australia

2007 - B9-2

Tools for understanding the thermo-electrical behaviour of XLPE insulation in power cables and accessories

LE ROY Séverine, BAUDOIN Fulbert, TEYSSEDRE Gilbert, LAURENT Christian BOUFAYED Fakher; Laboratoire Plasma et Conversion d'Énergie, Université Paul Sabatier; Toulouse, France

DISSADO Leonard A.; University of Leicester; UK

MONTANARI Gian Carlo; University of Bologna; Italy

2007 - B9-3

Improvements in superabsorbent water blocking materials for new power cable applications

CZYPRYNA Stephen, EVERAERE Jacques; Geca Tapes b.v.; Bailleul, France

DELATTRE Michel; PGI Nordlys; Bailleul, France

2007 - B9-4

Energy cable modelling under power electronic converter constraints

WEENS Yannick, IDIR Nadir, FRANCHAUD Jean-Jacques, BAUSIERE Robert; Université des Sces et Techn. de Lille (USTL-L2EP); France

2007 - B9-5

Longitudinal induction voltage measurement on communication cables running parallel to overhead lines or power cables

SHARAFI Dean; Western Power Corporation; Perth, Australia

KLAPPER Ulrich; Omicron electronics, Klaus; Austria

2007 - B9-6

K-factor measurement of cables for optimum reliability of distance protection and fault locators

KLAPPER Ulrich; Omicron electronics, Klaus; Austria

FICKERT Lothar; Technical University of Graz (TU Gratz); Austria

2007 - B9-7

Sheath circulating current calculations and measurements of underground power cables

CHEN Xiaolin, WU Kai, CHENG Yonghong, YAN Li; State Key Lab. Of Electrical Insulation and Power Equipment (SKLEI) Xi'an Jiaotong University (XJTU); Shaanxi, China

2007 - C5-11

High Performance MV Cable Semi Conducting Shields

EASTER Mark; General Cable; Indianapolis, USA

CANEROT Isabelle; SILEC CABLE; Montereau, France

2007 - C5-1-10

Dielectric system for submarine electro hydraulic umbilical up to 35 kV

TEIXEIRA Mario Daniel Junior; MDR Consultoria; Rio de Janeiro, Brazil

ABIB Luciana; Marine Production Systems do Brasil; Rio de Janeiro, Brazil

2007 - C5-1-11

A development of underground distribution cable for water-blocking and reducing protrusions

LEE Jae-bong, KIM Ju-yong, SONG Il-keun; Korea Electric Power Institute (KEPRI); Daejeon, South Korea

KIM Byung-sook; Korea Electric Power Corporation (KEPCO); South Korea

PORCHERAY Gilles; Tyco Electronics SIMEL; France

2007 - C5-1-12

Development of Pre-Molded Joint for 230 kV XLPE Power Cable

KIM Hwa Jong, KIM Hyun Joo, KIM S.Y., SONG Jae Hyuk; E.HV. Acc'y R&D Center, Taihan Electric Wire Co.; Seoul, South Korea

2007 - C5-1-13

Transition joints

COURSET Ludovic; RTE CNER; Paris France

HONDAA Pierre; EDF R&D; Moret-sur-Loing, France

2007 - C5-1-14

Compact various transition joints for up to 154 kV power cable

NIINOBE Hiroshi; VISCAS Corporation; Ichihara, Japan

YOKOYAMA Shigekazu, TORAI Yasuo; VISCAS Corporation; Tokyo, Japan

KANEKO Satoshi; VISCAS Corporation; Hirastuka, Japan

2007 - C5-1-15

Upgrading quality of 275 kV Y - branch pre-fabricated transition joint

Tatsuo Nakanishi, Takehiro Nozaki, Tadashi Ohimo, Masaru Watanabe, Shunichirou Ban, Shigekatsu Yamada; J-Power Systems Corp.; Osaka, Japan

2007 - C5-1-16

Development of outdoor-sealing-end of prefabricated-composite-insulator for 66/77 kV XLPE cable

IWASAKI Kimihiro, TANAKA Atsushi, TOYA Atsushi; Tokyo Electric Power CO.; Tokyo, Japan

SATOU Hiromasa; EXSYM Corp,; Sagamihara, Kanagawa, Japan

ADACHI Kazuhisa, SEMA Nobuyuki; SWCC SHOWA Cable System Co; Kanagawa, Japan

2007 - C5-1-17

Development of dry type out-door terminations for 66 to 110 kV XLPE cable

OONO Kouichi; VISCAS Corporation; Ichihara, Japan

KANEKO Satoshi, TAKAOKA Isao; VISCAS Corporation; Hiratsuka, Japan

2007 - C5-12

Compounding of semiconductives for high voltage cables

RICHARDSON Colin G.; Buss AG; Pratteln, Switzerland

2007 - C5-13

Stabilizer concepts for Silane crosslinked polyethylene cable applications

HERBST Heinz; CIBA Specialty Chemicals; Basel, Switzerland

FAGOURI Chris; CIBA Specialty Chemicals; Tarrytown, USA

2007 - C5-14

Performance of modern cables in Central Europe

Detlef Wald; BOREALIS Polymers NV; Mechelen, Belgium

Annika Smedberg; BOREALIS AB; Stenungsund, Sweden

2007 - C5-15

Long-life XLPE insulated power cables

HAMPTON Nigel, HARTLEIN Richard; NEETRAC, Georgia Institute; Atlanta, USA

LENNARTSSON Hakan; Borouge Pty; Hong Konk

ORTON Harry; OCEI; Vancouver, BC, Canada

RAMACHANDRAN Ram; The Dow Chemical Company; Somerset, NJ, USA

2007 - C5-16

Development on recycling technology of XLPE

SEKIGUCHI Youitsu, OHKAWA Noriyuki, NOJO Hitoshi, HASHIMOTO Satoru; J-Power Systems Corp.; Tokyo, Japan

2007 - C5-17

Innovative bolted connector for LV and MV with stepless shear bolts

GROSS Hervé, FRANK Erich; PFISTERER KONTAKTSYSTEME GmbH & Co. KG,; Winterbach, Germany

2007 - C5-18

Surge propagation and protection of underground distribution cables

LEE Jae-bong, KIM Ju-yong, PARK Chul-bae, JUNG Yeon-ha; Korea Electric Power Institute (KEPRI); South Korea

2007 - C5-19

Advances in chemical rejuvenation: extending medium voltage cable life 40 years

BERTINI Glen J., VINCENT Gary A.; Novinium Inc.; Kent, USA

2007 - C5-21

Modern FEM tools – an example of cables installed in duct-banks

KARLSTRAND Johan, HENNING Gunnar;ABB Power Systems; Karlskrona, Sweden

2007 - C5-22

Application results of real-time ampacity estimation system and intelligent power cable system

NAM S.H., LEE J.M., KIM K.Y.,KIM C.S., LEE S.K., JEON S.I.; LS Cable; Anyang-si, South Korea

KIM H.L., KIM Y.S., LIM H.E.; KEPCO; Seoul, South Korea

2007 - C5-23

Adaptive monitoring program for dynamic thermal rating of power cables

BRAKELMANN Heinrich, HIRSCH Holger, RÖHRICH Armin, SCHEIFFARTH Hans-Peter, STAMMEN Jörg; University of Duisburg-Essen; Germany

2007 - C5-24

HV cables operating in a dynamic rating regime, a beneficial option!

DE WILD Frank H., BOONE Wim; KEMA; Arnhem, The Netherlands

2007 - C5-25

Development on the mortar material for cable systems in a directional drilling

NISHIYAMA Yoshinari, MASHIMA Hironori, UESAWA Makoto, SAITO Hiroshi, ISHIZONE Takeshi; Chubu Electric Power Co. Inc; Nagoya, Japan

MIZUNO Satoshi; Toenec Corp.; Japan

2007 - C5-26

Sharing pipelines, tunnels, multipurpose structures, and rights of way among cables, optical cables, gas lines, sewers, heating ducts, and waterlines

JEYAPALAN Jey K.; Dr Jeyapalan & Associates; New Milford, CT, USA

2007 - C5-27

Fire prevention method for 275 kV oil-filled cable joint in TEPCO

TOYA Atsushi, NASUKAWA Shinsuke; Tokyo Electric Power Company; Tokyo, Japan

2007 - C5-28

Development and efficacy of sheath current reduction devices on underground power cable systems

YOON Hyung-Hee, KANG Ji-Won, MYOUNG Keun-Sik; KEPRI; South Korea

KWAK Bang-Myung; KEPCO; Japan

2007 - C5-29

Multiconductor cell analysis of power cable steady state

BENATO Roberto; University of Padova; Italy

2007 - C7-11

A user-friendly tool for simulating the time-dependent field distribution in PE insulation on the basis of a physical approach

LE ROY Séverine, BOUFAYED Fakher, BAUDOIN Fulbert, TEYSSEDRE Gilbert, LAURENT Christian; Laboratoire Plasma et Conversion d'Énergie, Université Paul Sabatier; Toulouse, France

2007 - C7-1-10

Exploring the water treeing inhibition effect of antioxidants for XLPE insulation

MATEY Gabriel, LABBE Dennis; Products and Marketing Ltd; Geneva, Switzerland

2007 - C7-1-12

Study of thermally and water tree aged polyethylene by infrared spectroscopy, absorption currents and space charge measurements

STANCU Christina, NOTINGHER Petru; Politehnica University of Bucharest; Romania

NOTINGHER P. jr, CASTELLON Jérôme, AGNEL Serge, TOUREILLE Alain; LEM, Université de Montpellier 2; France

RAKOWSKA Aleksandra, SIODLA Krzysztof; Technical University of Poznan; Poland

2007 - C7-1-13

Water treeing at high hydrostatic pressure and temperatures

FAREMO Hallvard, HVIDSTEN Sverre, BENJAMINSEN Jan Tore; SINTEF Energy Research; Trondheim, Norway

BORNES Atle Harald; Statoil ASA; Bergen, Norway

2007 - C7-1-14

Improved understanding of extruded MV cable performance through the modification of existing approval protocols

HAMPTON Nigel, HARTLEIN Richard; NEETRAC, Georgia Institute; Atlanta, USA

2007 - C7-1-15

A molecular approach to the electrical aging of XLPE cables

CRINE Jean-Pierre; Technology Consultant lso with Ecole Polytechnique de Montréal; St Bruno, Canada

CRINE Jean-Pierre; Technology Consultant lso with Ecole Polytechnique de Montréal; St Bruno, Canada

2007 - C7-1-16

Kinetic modelling of phenol stabiliser efficiency in polyethylene submitted to nuclear environments

RICHAUD Emmanuel, COLIN Xavier, AUDOUIN Ludmila, VERDU Jacques; LIM-ENSAM de Paris; France

MONCHY-LEROY Carole; EDF R&D; Moret-sur-Loing, France

2007 - C7-1-17

A numerical method for 3D-description of scattered characteristic aging data from multistress aged XLPE-cable insulation

REUTER Mark, GOCKENBACH Ernst, BORSI Hossein; Schering Inst., Leibnitz Universität; Hannover, Germany

2007 - C7-1-18

Understanding and optimization of long term ageing in cable industry

STUHLDREIER Thomas, FOURNIER Jérôme; NEXANS Research Center; Lyon, France

PLANES Émilie; MATEIS UMR CNRS 5510 INSA Lyon; France

2007 - C7-1-19

Electrical and physico-chemical analysis of Belgium medium voltage cables data bank

CASTELLON Jérôme, AGNEL Serge, NOTINGHER Petru jr, TOUREILLE Alain; IES-UM2, Université de Montpellier; France

BEAUGUITTE Dimitri, PLATBROOD Gerard, TITS Yvan; Laborelec; Linkebeek, Belgium

2007 - C7-12

Development of diagnostic procedures for XLPE cables with water trees

FOOTTIT Frith, LYALL Jim, OYEGOKE Bolarin, BIRTHWHISTLE David; Queensland University of Technology (QUT); Australia

2007 - C7-13

Effect of cross-linking and antioxidant on the conductivity of the polyethylene

HOUABES M.; University Badji Mokhtar of Annaba; Algeria

2007 - C7-14

Annealing effect on the conductivity of XLPE insulation in power cable

BELANA Juan, ÒRRIT Jordi, DIEGO José Antonio, MUDARRA Miguel; Universidad de Catalunya (ETSEIAT); Barcelona, Spain

FRUTOS Fabián, ACEDO Miguel; Universidad de Sevilla (ETSII); Spain

2007 - C7-15

Effect of the dielectric strength test on dielectric properties

TAMUS Z. Á., NEMETH E. N; Budapest University of Technology; Hungary

2007 - C7-16

Space charge measurements in XLPE insulated mid-voltage cable: correlation with cable performance

TAMAYO Idalberto, ÒRRIT Jordi, DIEGO José Antonio; Universidad Politècnica de Catalunya (ETSEIAT); Barcelona, Spain

2007 - C7-17

Water treeing test results for different XLPE compounds obtained with needle techniques

SHUVALOV Mikhail, OVSIENKO Vladimir, OBRAZTOV Yuri; VNIIKP; Moscow, Russia

URBANCZYK Andrzej; BOREALIS; Poznan, Poland

BOSTRÖM Jan-Ove; BOREALIS AB; Stenungsund, Sweden

2007 - C7-18

Crosslinking and water treeing in polyethylene insulation

CIUPRINA Florin; ELMAT lab. Politehnica University of Bucharest; Romania

FILIPPINI Jean César, TEISSEDRE Gisèle; LEMD-CNRS / UJF; Grenoble, France

CAMPUS Alfred, SMEDBERG Annika; BOREALIS AB; Stenungsund, Sweden

2007 - C7-19

Initiation site analysis of vented water trees growing from the conductor screen of service and laboratory aged XLPE cable insulation

HVIDSTEN Sverre, FAREMO Hallvard, SELSJORD Mildrid; SINTEF Energy Karl; Stenungsund, Sweden

JÄGER Michael, SMEDBERG Annika, NILSSON Ulf H.; BOREALIS AB; Stenungsund, Sweden

KVANDE Stine; NTNU, Dept. of Physics; Trondheim, Norway

KALKNER Wilfried; Technische Universität Berlin; Germany

2007 - C7-2-1

Insulation diagnosis of high voltage power cables

GULSKI Edward, SMIT Johan J., CICHECKI Piotr; Delft University of Technology ; Delft, The Netherlands

DE VRIES Frank; Nuon Tecno, Alkmaar; The Netherlands

SEITZ Paul P., QUAK Ben; Seitz Instruments AG; Niederrohrdorf, Switzerland

PETZOLD Frank; SebaKMT; Baunach, Germany

2007 - C7-2-10

Novel method for on-site testing and diagnosis of transmission cables up to 250 kV

SEITZ Paul P., QUAK Ben; Seitz Instruments AG; Niederrohrdorf, Switzerland

GULSKI Edward, SMIT Johan J., CICHECKI Piotr; Delft University of Technology ; Delft, The Netherlands

DE VRIES Frank; Nuon Tecno; Alkmaar, The Netherlands

PETZOLD Frank; SebaKMT; Baunach, Germany

2007 - C7-2-11

Partial discharge diagnosis on live EHV power cable using planar UWB antenna

LWIN Kyaw-Soe, SHIN Dong-Hoon, YIM Youn-Chan, PARK Noh-Joon, PARK Dae-Hee; Wonkwang University; Iksan, South Korea

HWANG Doo-Hyun, LIM Jong-Cheon; Taihan Electric Wire; Seoul, South Korea

2007 - C7-2-12

Leak location in oil paper cables

LANDUCCI Laurent; RTE; Courbevoie, France

LANZARONE Lucien; RTE; Vitry-sur-Seine, France

Dominique Meurice; EDF R&D; Moret-sur-Loing, France

2007 - C7-2-13

Hydrogen elimination from a 225 kV HPOF pipe-type line

LINOIS Pierre; RTE-TENP - GIMR; Nanterre, France

BONNARDOT Gilles; RTE-TENP - GETSO; Guyancourt, France

GAZARIAN Serge; RTE-TENP; France

2007 - C7-2-14

Cable rejuvenation; past, present and future

STAGI William, CHATTERTON Wayne; UtilX Corporation; Kent, WA, USA

2007 - C7-2-15

Monitoring based maintenance for underground cables utilizing sensor networks

MIN Byoung-Woon, CHOI Ho-Woong, MYOUNG Hee-Chul, KIM Jung-Han; Hyundai Heavy Industries; Kyounggi, South Korea

NAM Sang-Bum; NeoTelecom; Seoul, South Korea

2007 - C7-2-16

Condition assessment of power cable systems in the energized state

SRINIVAS N. Nagu; UtilX Corporation; Kent, WA, USA

BERNSTEIN Bruce; Bruce S. Bernstein Consulting LLC; USA

2007 - C7-2-17

Diagnostic testing of MV accessories by Time Domain Spectroscopy (TDS)

POTVIN Carl, JEAN Daniel, LALANCETTE Daniel, PARPAL Jean-Luc, DRAPEAU Jean-François, L'ÉCUYER Richard; IREQ; Varennes Québec, Canada

BERNIER Simon; Ecole de Technologie Supérieure (ETS); Canada

2007 - C7-2-2

Wireless sensor network based partial discharges monitoring of underground cable systems

CHOI Ho-Woong, MIN Byoung-Woon, MYOUNG Hee-Chul, LEE Byoung-Ho; Hyundai Heavy Industries; Kyounggi, South Korea

CHO Sang-Moon; NeoTelecom Co.Ltd,; Seoul, South Korea

2007 - C7-2-3

Feasibility study on application of WIMAX technology to underground cables data acquisition

MYOUNG Hee-Chul, CHOI Ho-Woong, MIN Byoung-Woon, PARK Dong-Ho; Hyundai Heavy Industries; Kyounggi, South Korea

KIM Yong-Joo;NeoTelecom Co. Ltd,; Seoul, South Korea

2007 - C7-2-4

Advanced solution for on-site diagnosis of distribution power cables

GULSKI Edward, SMIT Johan J.; Delft University of Technology; Delft, The Netherlands

PETZOLD Frank; SebaKMT; Baunach, Germany

SEITZ Paul P., QUAK Ben; Seitz Instruments AG; Niederrohrdorf, Switzerland

DE VRIES Frank; Nuon Tecno; Alkmaar, The Netherlands

2007 - C7-2-5

Experiences with offline PD-diagnosis on MV cables – knowledge rules for asset decisions

PETZOLD Frank, BEIGERT Michael; SebaKMT; Baunach, Germany

GULSKI Edward; Delft University of Technology; Delft, The Netherlands

2007 - C7-2-6

Sensitivity verification procedure of VHF PD detection systems

MEIJER Sander, LADDE Ruben C., JONGEN Rogier A., SMIT Johan J.; Delft University of Technology (TU Delft); Delft, The Netherlands

HERMANS Theo J.W.H., LAMBALLAIS Lawrence; PRYSMIAN C&S; Delft, The Netherlands

2007 - C7-2-7

50 Hz Partial Discharge Diagnostics - Experience of N-Ergie AG. Minimizing cable failures by Reliability-Centered Maintenance of Networks

CHRISTL Hans-Jürgen; NexaTec GmbH; Germany

LINK Stefen; N-Ergie; Germany

Translation: Frank Verschraegen; IMCORP Europe BVBA; Lochristi, Belgium

2007 - C7-2-8

UHF Partial discharge diagnosis of plug-in cable terminations

DENISSOV Denis, KÖHLER Wolfgang, TENBOHLEN Stefan; University of Stuttgart; Germany

GRUND Ruben, KLEIN Thomas; PFISTERER Kontaktsysteme GmbH; Winterbach, Germany

2007 - C7-2-9

On-site partial discharge testing of distribution class cables using VLF and power frequency excitation

Detlev W. Gross, Markus Söller; Power Diagnostix Systems GmbH; Aachen, Germany

2011-A1-1

New technique to install power cables into ducts

Willem GRIFFIOEN - Plumettaz SA, Rotterdam; The Netherlands

Patrice BLANCHET - Plumettaz SA, Bex; Switzerland

Gérard PLUMETTAZ - Plumettaz SA, Singapore; Singapore

2011-A1-2

Transition technologies for HV cable systems

Volker AUE, Dietmar MEURER - Nexans Deutschland GmbH, Hannover; Germany

2011-A1-3

Oil filled cable leak location using PFT (Per-fluorocarbon tracing) - Non-intrusive oil filled cable leak location

Mike FAIRHURST - National Grid, Warwick; United Kingdom

Patrick KEELAN - PFT Tech, New York, NY; United States

2011-A1-4

First 220 kV city cable for retrofitting of steel pipe cables

Anika BOSSE, Tobias WOLLSCHLÄGER, Volker WASCHK - nkt cables GmbH, Köln; Germany

2011-A1-5

New repair method of a 380 kV fluid-filled cable, damaged by impact

Georg SVEJDA, Johannes VAVRA - Wienstrom, Vienna; Austria

Manfred WANDA - Prysmian, Vienna; Austria

Nick CRANE - Prysmian, Bishopstoke; United Kingdom

2011-A1-6

Improved installation methodologies for EHV cables in underground tunnels

Per CHRISTENSEN, Jesper Lykke NIELSEN - nkt cables, Broendby; Denmark

Alwyn HANEKOM, David CHEALE - Balfour Beatty Utility Solutions Ltd, Dartford; United Kingdom

2011-A2-1

Specification for extruded HVDC land cable systems

Rémi VATONNE, Nathalie BOUDINET, Jonathan BENETEAU, Pierre HONDAA, Frédéric LESUR - RTE, Paris; France

Gregorio DENCHE, José Manuel ARGUELLES ENJUANES - Red Eléctrica de España, S.A., Madrid; Spain

2011-A2-2

Key parameters for extruded DC cable qualification

Wilfried FRELIN, Philippe EGROT - EDF R&D, Moret-sur-Loing; France

2011-A2-3

Development of pre-molded accessories for HVDC extruded cable system

SAKAI Yasuhiro, NIINOBE Hiroshi, HIRASAWA Takayuki - VISCAS Corporation, Ichihara, Chiba; Japan

2011-A2-4

Development of a 270 kV XLPE cable system for HVDC applications

Mohamed MAMMERI, Marie Laure PAUPARDIN, Bernard POISSON - Silec Cable (General Cable), Montereau; France

2011-A2-5

Development of high performance polymeric materials for HVDC cables

Andreas FARKAS, Carl-Olof OLSSON, Gustavo DOMINGUEZ - ABB AB, High Voltage Cables, Karlskrona; Sweden

Villgot ENGLUND, Per-Ola HAGSTRAND, Ulf. H. NILSSON - Borealis AB, Stenungsund; Sweden

2011-A2-6

Evolution of the distributions of electric field and space charges in an extruded HVDC cable

Carl-Olof OLSSON - ABB AB, Corporate Research, Västerås; Sweden

Marc JEROENSE - ABB AB, High Voltage Cables, Karlskrona; Sweden

2011-A3-1

500 kV feed cable project for EXPO substation

JIANG Yun - Shanghai Municipale Electrical Power Company, Shanghai; China

JIANG Xiaojuan, WANG Zhigang - Power Grid Inspection & Maintenance Company, SMEPC (Shanghai Municipale Electrical Power Company), Shanghai; China

2011-A3-2

New 400 kV underground XLPE insulated cable system in UAE

SHIMIZU Toshio, AOKI Toshiji, KURATA Tatsuo - J-Power Systems Corporation, Osaka; Japan

SUKEGAWA Takuya, IGI Tsuyoshi - J-Power Systems Corporation, Hitachi, Ibaraki; Japan

MASHIO Shoji - J-Power Systems Corporation, Tokyo; Japan

2011-A3-3

Technical solution to completion of the world first 500 kV XLPE underground cable system in Shanghai

WONG Hai Ngiing, ABE Shunsuke, YAMAMOTO Shoji, TORAI Yasuo - VISCAS Corporation, Tokyo; Japan

JIANG Yun, YANG Wen Wei, FANG Hao - Shanghai Municipale Electrical Power Company, Shanghai; China

2011-A3-4

Prequalification test of 500 kV XLPE cable system in China

XIA Rong, YANG Liming - State Grid Electric Power Research Institute, Wuhan, Hubei province; China

YANG Rongkai - Quality Inspection and Test Center for Equipment of Electric Power, Wuhan, Hubei province; China

JIN Guangqi, LV Gengming - Shenyang Furukawa Cable Corp., LTD., Shenyang, Liaoning; China

TAKAO Nakano - VISCAS Corporation, Tokyo; Japan

2011-A3-5

Experience with developing and installing of a three core 150 kV power cable

Jacco SMIT, Arie STEENIS, Alex GESCHIERE - Liandon, Alkmaar; The Netherlands

Volker WASCHK, Jens WOLCKEN, Hendrik REITER - nkt cables GmbH, Köln; Germany

2011-A3-6

Development, qualification and experiences with 500 kV XLPE cable systems

Johannes KAUMANNS, Andreas WEINLEIN, Gero SCHROEDER, Volker STROOT - Suedkabel GmbH, Mannheim; Germany

2011-A3-7

Return of experience of 380 kV power cable failures

Sander MEIJER - TenneT TSO bv, Arnhem; The Netherlands

Johan J. SMIT, Xiaolin CHEN - Delft University of Technology, Delft; The Netherlands

Wilfried FISCHER - 50Hertz Transmission GmbH, Berlin; Germany

Luigi COLLA - Terna S.p.A., Rome; Italy

2011-A4-1

Retrofitting of pipe-type cables

Pierre HONDAA, Martial GUILLEMIN, Frédéric LESUR - RTE, Paris; France

2011-A4-2

HVAC cables with ferromagnetic sheathings

Jacco SMIT - Liandon, Alkmaar; The Netherlands

Heiner BRAKELMANN, Jorg STAMMEN, Jan BRUEGGMANN - University Duisburg-Essen, Duisburg; Germany

Volker WASCHK - nkt cables GmbH, Köln; Germany

2011-A4-3

Towards smart grid approach: Data acquisition from on-line monitoring of high voltage XLPE/oil-filled transition joints

Luigi TESTA - Techimp, Bologna; Italy

Andrea CAVALLINI, Gian Carlo MONTANARI - University of Bologna, Bologna; Italy

Arie MAKOVOZ - ConEdison, New York, NY; United States

2011-A4-4

The impact of transmission cable system construction and design on commissioning test options and results

Steven CAMPBELL - General Cable / Silec Cable, Carrollton, Georgia; United States

Benjamin LANZ - IMCORP, Manchester, Connecticut; United States

2011-A4-5

Feasibility study and cable system optimization in application of 500 kV XLPE cable in Edmonton region of Alberta

Ali DARIANI - SNC LAVALIN T&D, Calgary Alberta; Canada

2011-A4-6

Recent experiences with AC High voltage test equipment and PD commissioning testing of XLPE cable systems rated 69 kV and above

Mark FENGER - Kinectrics Inc., Toronto, Ontario; Canada

2011-A5-1

Cable accessories workmanship - US perspective

Milan UZELAC, Steve WARTON - G&W Electric Company, Blue Island, IL; United States

Frank FRENTZAS - Exelon-Commonwealth Edison, Chicago, IL; United States

2011-A5-2

Development of dry outdoor termination with silicone gel for self-standing

MORI Anna, MARUICHI Shinji, NIINOBE Hiroshi, SUETSUGU Masahiro - VISCAS Corporation, Ichihara, Chiba; Japan

2011-A5-3

Dry terminations for high voltage cable systems

Pascal STREIT - Nexans Switzerland, Penthalaz; Switzerland

2011-A5-4

Remedial action and further quality assuring measures after a failure in a 400 kV GIS cable termination

Frank JAKOB, Frank KOWALOWSKI, Claus KUHN, Wilfried FISCHER - 50Hertz Transmission GmbH, Berlin; Germany

Sigurdur A. HANSEN - Suedkabel GmbH, Mannheim; Germany

2011-A5-5

Long time operational experience with 400 kV XLPE power cable systems in Berlin

Claus Georg HENNINGSEN, Wilfried FISCHER - 50Hertz Transmission GmbH, Berlin; Germany

2011-A5-6

Red Electrica's operating experience on 400 kV submarine and underground interconnection between Spain and Morocco

Rafael GARCÍA FERNÁNDEZ, Miguel Ángel PÉREZ LOUZAO, Maria Dolores LÓPEZ-MENCHERO CÓRDOBA - Red Eléctrica de España, S.A., Alcobendas; Spain

2011-A6-1

Offshore wind parks grids connection projects in German North Sea

Dongping ZHANG, Jochen JUNG, Thomas Jan LEBIODA - Tennet Offshore GmbH, Bayreuth; Germany

2011-A6-2

High capacity HVDC subsea link for the UK

Gareth PARKER - NGET, Warwick; United Kingdom

Paul CUNNINGHAM - Scottish Power, Glasgow, Scotland; United Kingdom

2011-A6-3

Cables for deep water applications

Marco BACCHINI, Marco MARELLI, Ambrogio ORINI - Prysmian PowerLink, Milan; Italy

2011-A6-4

Application of XLPE submarine power cable for extra high voltage

YANAGAWA Hiroyuki, MATSUNAGA Osamu, NAKAGAWA Toshihiro, ASAI Shinya - J-Power Systems Corporation, Hitachi, Ibaraki; Japan

KURATA Tatsuo - J-Power Systems Corporation, Osaka; Japan

MASHIO Shoji - J-Power Systems Corporation, Tokyo; Japan

2011-A6-5

HVAC power transmission to the Gjøa platform

Erik ERIKSSON, Marc JEROENSE, Magnus LARSSON-HOFFSTEIN, Claes SONESSON - ABB AB, High Voltage Cables, Karlskrona; Sweden

Knut-Aril FARNES, Rolf Ove RÅD, Karl Atle STENEVIK - Statoil AS, Stavanger; Norway

2011-A6-6

Corrosion behaviour of submarine power cables in seawater environments

Daniel ISUS, Juan de Dios MARTÍNEZ - General Cable Sistemas S.A., Manlleu, Barcelona; Spain

Virginia MADINA, Patricia SANTA COLOMA - TECNALIA, San Sebastián; Spain

2011-A7-1

Submarine cable metallic sheath diagnostic

Harry ORTON - Orton International Consulting, Vancouver, BC; Canada

Avaral RAO - Powertech, Vancouver, BC; Canada

David KUNG - Powertech, Vancouver, BC; Canada

David HICKS - Newfoundland Hydro, St Johns, NFLD; Canada

2011-A7-2

Influence of subsea conditions on the long term performance of AC XLPE cables

Kenneth JOHANSSON, Anna DAVIDSSON - Draka Sverige AB, Nässjö; Sweden

Martin JAKOBSSON, Ulf. H. NILSSON, Jan-Ove BOSTRÖM - Borealis AB, Stenungsund; Sweden

Hallvard FAREMO, Odd LILLEVIK - SINTEF Energy Research, Trondheim; Norway

2011-A7-3

Armouring loss in three-core submarine XLPE cables

Danijela PALMGREN, Johan KARLSTRAND, Gunnar HENNING - ABB, Karlskrona; Sweden

2011-A7-4

On the optimum burial depth of submarine power cables

Thomas WORZYK, Johan KARLSTRAND - ABB, Karlskrona; Sweden

2011-A7-5

Development and qualification of deepest water power umbilical

Arild FIGENSCHOU, Jan Ole DUNSERUD - Aker Solutions, Oslo; Norway

Daniel ISUS - Grupo General Cable Sistemas S.A., Manlleu, Barcelona; Spain

Emmanuel BIC - Silec Cable (General Cable), Montereau; France

2011-A7-6

Dielectric loss characterization of Hydro-Québec medium voltage (MV) submarine cables - Phase 1

Jean-François DRAPEAU - Institut de recherche d'Hydro-Québec (IREQ), Varennes, Québec; Canada

Bruno CANTIN - Hydro-Québec Distribution, Québec, QC; Canada

Nigel HAMPTON, Joshua PERKEL - NEETRAC, Atlanta, GA; United States

2011-A8-1

A measuring system of conductor AC and DC resistance

Karl-Erik RYDLER - SP Technical Research Institute of Sweden, Boras; Sweden

Mats SJOBERG, Jorgen SVAHN - ABB AB, Karlskrona; Sweden

2011-A8-2

Advanced measurement of AC resistance on skin-effect reduced large conductor power cables

Gero SCHROEDER, Johannes KAUMANNS - Suedkabel GmbH, Mannheim; Germany

Ronald PLATH - Ing.-Büro HPS Berlin, Berlin; Germany

2011-A8-3

New generation of on-site testing technology for transmission power cables

Rogier JONGEN, Paul SEITZ, Ben QUAK - Seitz Instruments AG, Niederrohrdorf; Switzerland

Frank De VRIES - Liandon BV, Alkmaar; The Netherlands

Piotr CICHECKI - Delft University of Technology, Delft; The Netherlands

2011-A8-4

A new approach for testing long HV and UHV cables

Peter MOHAUPT, Tobias MEHL - Mohaupt High Voltage GmbH, Mieders; Austria

2011-A8-5

Alternatives for HVAC testing of long HV cables in the factory and on-site

Frank SCHREITER, Stefan SCHIERIG, Peter COORS - HIGHVOLT Prüftechnik Dresden GmbH, Dresden, Saxony; Germany

2011-A8-6

Effectiveness of variable frequency resonant method for after-laying test on high voltage extruded cable

ZHAO Jiankang, OUYANG Benhong, RAO Wenbin, LI Wenjie, XIA Rong - State Grid Electric Power Research Institute, Wuhan, Hubei province; China

2011-A9-1

Working out extension of qualification procedures for HV and VHV cable systems

Pierre HONDAA - RTE, Paris; France

Éric DORISON - EDF R&D, Moret-sur-Loing; France

2011-A9-2

Results of robustness test on medium voltage joints

Christophe TOURCHER, Christophe MOREAU - EDF R&D, Moret-sur-Loing; France

Roger TAMBRUN - ERDF, Paris La Défense; France

2011-A9-3

Tests of outer protection for buried joints, experience and recommendation

Edwin PULTRUM, Pieter KUIJPERS, Wouter SLOOT - KEMA, Arnhem; The Netherlands

2011-A9-4

Development of technology and equipment of pre-qualification test for 500 kV XLPE cable systems

YANG Liming, XU Linhua, MENG Shaoxin, XIA Rong - State Grid Electric Power Research Institute, Wuhan, Hubei province; China

YANG Rongkai, HOU Junping - Quality Inspection and Test Center for Equipment of Electric Power, Wuhan, Hubei province; China

2011-A9-5

HV cable qualification for IEC 62067-2006 and ICEA S-108-720-2004

Caryn RILEY, Raymond C. HILL, Nigel R. HAMPTON - NEETRAC, Atlanta, GA; United States

2011-A9-6

Special heat cycle voltage test of 275 kV XLPE cable system

Bernardo DAVID, Nicola MOFFA, John McCORMACK, Peter BUTTERFIELD-ROSSI - Electranet, Adelaide, South Australia; Australia

KIM Jeong hyun - Taihan Electric Co, Seoul; Korea

HEO Hoi-deok - LS Cable Ltd, Gumi, Gyeongbuk; Korea

George BUCEA - Consultant, Sydney; Australia

Hans MAYER - Consultant, Melbourne, Victoria; Australia

Henry KENT - Energy Action, Sydney; Australia

2011-A10-1

Investigation on the technologies for defect localization and characterization on medium voltage underground lines

Gonzalo MAIZ - Iberdrola Distribución, Bilbao; Spain

Armando RODRIGO - Instituto Tecnológico de la Energía, Paterna; Spain

Pedro LLOVERA-SEGOVIA - Instituto de Tecnología Eléctrica - Universidad Politécnica de Valencia, Valencia; Spain

Lluis SALES - Prysmian Cables y Sistemas, Barcelona; Spain

Xavier BALZA - General Cable, Barcelona; Spain

2011-A10-2

First practical utility implementations of monitored withstand diagnostics in the USA

Chris FLETCHER - Duke Energy, Charlotte, NC; United States

Nigel HAMPTON, Joshua PERKEL - NEETRAC, Atlanta, GA; United States

Jean Carlos HERNANDEZ - Universidad de Los Andes, Mérida, Mérida; Venezuela

Jeff HESSE - Duke Energy, Cincinnatti, OH; United States

Mike PEARMAN - Georgia Power, Atlanta, GA; United States

Tim WALL - Alabama Power, Birmingham, AL; United States

Walter ZENGER - Pacific Gas & Electric, San Francisco, CA; United States

2011-A10-3

A new testing method of LV underground cable insulation

Janislaw TARNOWSKI, Jacques CÔTÉ, André GAUDREAU, Pierre GINGRAS, Mircea IORDANESCU - Hydro-Québec, Varennes, Québec; Canada

2011-A10-4

Integral cable condition assessment for the complete network

Alexander GERSTNER - Baur Prüf - und Messtechnik, Sulz; Austria

2011-A10-5

Effect of supply voltage frequency on testing medium voltage cable in the grid

Fabrice ZORZI, Thierry ESPILIT - EDF R&D, Moret-sur-Loing; France

Roger TAMBRUN - ERDF Direction Réseau, Paris La Défense; France

2011-A10-6

On-line screening of MV cable network grid through partial discharges measurements

Marco TOZZI, Andrea CAVALLINI, Gian Carlo MONTANARI - Techimp HQ srl, bologna; Italy

2011-B1-1

Impact of EMF on cable ratings and cable systems

Harry ORTON - OCEI, Vancouver, BC; Canada

Paolo MAIOLI - Prysmian Cables and Systems, Milan; Italy

Tim BARNES - Transgrid, Sydney; Australia

Heinrich BRAKELMANN - University Duisburg-Essen, Duisburg; Germany

Jarle BREMNES - Nexans Norway AS, Halden; Norway

Sudhakar CHERUKUPALLI - BC Hydro, Vancouver, BC; Canada

François COCHET - Nexans, Neuchatel; Switzerland

Jean HOEFFELMAN - Elia-Engineering, Brussels; Belgium

Frédéric LESUR - RTE-France, Paris; France

Julio LOPES - Inovatec Consultoria e Enginharia, Sao Paolo; Brazil

Josu ORELLA - IBERDROLA, Bilbao; Spain

Jacco SMIT - Liandon, Amsterdam; The Netherlands

2011-B1-2

EMF conductor management of cable systems

Frédéric LESUR - RTE, Paris; France

2011-B1-3

SC-IES-Cables: Single-core cables with integrated electromagnetic shielding

Heinrich BRAKELMANN, Jan BRUEGGMANN - University Duisburg-Essen, Duisburg; Germany

Volker WASCHK - nkt cables GmbH, Köln; Germany

2011-B1-4

Shielding of the electromagnetic field generated by HV underground cable lines

Paolo MAIOLI - Prysmian Cables & Systems, Milan; Italy

2011-B1-5

Ampacity derating effects of magnetic field management techniques used with underground transmission cables

John COOPER - Power Delivery Consultants, Tijeras, New Mexico; United States

David FUGATE - Electric Research & Management, Pittsburgh, Pennsylvania; United States

Tiebin ZHAO - Electric Power Research Institute, Charlotte, North Carolina; United States

2011-B1-6

Magnetic mitigation of HV cable junction zone

Aldo CANOVA - Dipartimento Ingegneria Elettrica, Politecnica di Torino, Turin; Italy

Luca GIACCONE - NoField srl - Incubatore di Imprese Politechnico di Torino, Turin; Italy

2011-B2-1

Evaluation of the magnetic induction on metal pipelines by AC power cable circuits

LIU Ying, MING LIU, CAO Xiaolong - Xi'an Jiaotong University, Xi'an, Shannxi; China

HAN Xiaopeng, ZHAO Rui - Beijing Electric Power Design Institute, Beijing; China

2011-B2-2

Cable systems in multi-purposes or shared structures

Jey JEYAPALAN - Cigre' WG-B1.08, Member from United States

Ray AWAD - Cigre' WG-B1.08, Member from; Canada

Ken BARBER, Colin PEACOCK - Cigre' WG-B1.08, Member from Australia

Roberto BENATO - Cigre' WG-B1.08, Member from Italy

Ian BUTT - Cigre' WG-B1.08, Member from United Kingdom

Frank De WILD - Cigre' WG-B1.08, Member from The Netherlands

GOTO Takeshi, SAKUMA Susumu, TAKAHASHI Yoshihisa - Cigre' WG-B1.08, Members from Japan

KIM Jeong-tae - Cigre' WG-B1.08, Member from Korea

Jordi MONTEYS - Cigre' WG-B1.08, Member from Spain

Christophe MOREAU - Cigre' WG-B1.08, Member from France

Kjell OBERGER - Cigre' WG-B1.08, Member from Sweden

Rudolph WOSCHITZ - Cigre' WG-B1.08, Member from Austria

Kok Thean YOOM - Cigre' WG-B1.08, Member from Singapore

2011-B2-3

275 kV XLPE cable bridge crossings - Design and construction issues

John McCORMACK, Nicola MOFFA, Raju UPADHYAYA - ElectraNet, Adelaide, South Australia; Australia

KIM Jeong hyun - Taihan Electric Co, Seoul; Korea

HEO Hoi-deok - LS Cable Ltd, Gumi, Gyeongbuk; Korea

Henry KENT - Energy Action, Sydney; Australia

2011-B2-4

Undergroud links across fields

Alexandre IRLE, Jean ISOARD - RTE, Paris La Défense; France

2011-B2-5

Development of new recyclable insulation material for power cable

KIM Jinman, HAN Bongsoo, KIM Youngjun - ILJIN Electric, Hwasung-si, Kyunggi-do; Korea

CHO Kyucheol, KU Kwanghoi, LEE Jaesun - SK Energy, Daejeon; Korea

KIM Dongmyung, JOUNG Jongman, KWON Taeho - KEPCO Research Institute, Daejeon; Korea

2011-B2-6

New technology for recycling of plastics from cable waste

Annika BOSS - Swerea IVF, Mölndal; Sweden

Jan-Ove BOSTRÖM, Per-Håkan NILSSON - Ineos ChlorVinyls, Stenungsund; Sweden

Andreas FARKAS - ABB AB, Karlskrona; Sweden

Alf ERIKSSON - Nexans IKO Sweden AB, Grimsås; Sweden

Erik RASMUSSEN - Stena Metall AB, Gothenburg; Sweden

Elin SVENNINGSSON - Draka Kabel Sverige AB, Nässjö; Sweden

Mattias DALESJÖ - Volvo 3P, Gothenburg; Sweden

Alf JOHANSSON - Volvo Car Corporation, Gothenburg; Sweden

2011-B3-1

Fire performance of HV and EHV XLPE insulated cables

James ROBINSON, Wendy LOYENS - Borealis Polymers NV, Beringen; Belgium

Graeme ALEXANDER - Olex Cables, Victoria; Australia

2011-B3-2

The role of the EU Construction Products Directive in supporting the application of improved low fire-hazard cables

Jan SCHUTTEN - Europacable, Brussels; Belgium

2011-B3-3

IEEE, API and IEC Standards update for testing, selection and installation of fire-rated circuit integrity cables

Arturo MALDONADO - A&M Technology Group LLC, Naples, Florida; United States

2011-B3-4

Study on the reaction to fire of medium voltage cables systems

Neus GENERÓ, Jacint ROVIRA, Juan de Dios MARTÍNEZ - Grupo General Cable Sistemas S.A., Manlleu, Barcelona; Spain

Saturnino MARTÍN, Gonzalo MAÍZ - IBERDROLA, Bilbao; Spain

Gregorio DENCHE - Red Eléctrica de España, S.A., Madrid; Spain

2011-B3-5

Fire performance cables under current overload conditions

Ivan IVANOV, Graeme ALEXANDER - Olex, a Nexans company, Melbourne, Victoria; Australia

Richard HOSIER, Ken BARBER - Nexans Asia Pacific, Singapore; Singapore

2011-B3-6

Fire equipment system in underground tunnels of KEPCO

PAIK Nam-yeol, KIM Hong-lae - KEPCO, Seoul; Korea

2011-B3-7

Assessment of the reaction to fire performance of electric cables under the EU construction products directive

Terence JOURNEAUX - Prysmian Cables & Systems Limited, Eastleigh; United Kingdom

2011-B4-1

HVDC XLPE cable systems applicable for higher temperature and polarity reversal operation

MURATA Yoshinao, ABE Kazutoshi, MATSUNAGA Osamu, ASAI Shinya, KATAKAI Shoshi - J-Power Systems Corporation, Hitachi, Ibaraki; Japan

MASHIO Shoji, SUIZU Makoto - J-Power Systems Corporation, Minato-ku, Tokyo; Japan

2011-B4-2

Electric field measurements on XLPE/EPDM 2-layer insulation systems under DC stress

Jérôme MATALLANA, Ludovic BOYER, Jean-François BRAME, Pierre MIREBEAU - Nexans France, Calais; France

Jérôme CASTELLON, Petru NOTINGHER, Serge AGNEL, Alain TOUREILLE - Institut d'Electronique du Sud - Université Montpellier 2, Montpellier; France

2011-B4-3

Dielectric characterization of non-linear materials subjected to high DC and transient stresses

Ludovic BOYER, Jérôme MATALLANA, Xavier MEERSSEMAN - Nexans France, Calais; France

Björn SONERUD - Nexans Norway AS, Halden; Norway

Arnaud ALLAIS - Nexans Research Centre, Lyon; France

Jérôme CASTELLON, Petru NOTINGHER - Institut d'Electronique du Sud - Université Montpellier 2, Montpellier; France

2011-B4-4

Further developed fully insulated high voltage aerial cables

Lars EFRAIMSSON, Bengt STRÖM, Thomas CARLQVIST - Ericsson AB, Falun; Sweden

2011-B4-5

Introduction of mitigation technique to control magnetic field radiated by underground cables

Kamal BEN HAMMADI, Fabien CHARLES, Bernard DHUICQ - Silec Cable (General Cable), Montereau; France

2011-B5-1

Study of a 100 km underground cable system to supply or deliver 135 MVA to or from a remote plant

Mark STEMMLE - Nexans Deutschland GmbH, Hannover; Germany

Ken BARBER - Nexans Asia-Pacific, Singapore; Singapore

2011-B5-2

Electrical studies performed to insert long AC cables in the French grid - First conclusions

Sébastien DENNETIERE, Jonathan DUFOUR, Alexandre PARISOT, Jean-Pierre TAISNE, Yannick VERNAY - RTE, Paris la Défense; France

2011-B5-3

Contribution to localization of a fault on a long extruded submarine cable by LV Time Domain Reflectometry

Alain HERBRETEAU - OTC, Avignon; France

Bernard DHUICQ - Silec Cable (General Cable), Montereau; France

2011-B5-4

Challenges during planning, development and performance at a 275 kV XLPE cable project in the city of Liverpool

Sebastian EBERT, Horst MEMMER, Johannes KAUMANNS, Andreas WEINLEIN, Gero SCHROEDER - Suedkabel GmbH, Mannheim; Germany

2011-B5-5

GIL for power transmission in specific site conditions

Alberto BERTINATO, Alain GIRODET - Alstom GRID, Villeurbanne; France

Mathieu BERNARD, Jean-Luc RAYON, Arnaud FICHEUX - Alstom GRID, Aix-Les-Bains; France

2011-B5-6

Pilot installation of a 380 kV directly buried gas insulated line (GIL)

Claus NEUMANN - Siemens AG, Erlangen; Germany

Stephan POEHLER - Amprion GmbH, Dortmund; Germany

2011-B6-1

Nuclear cables: Lifetime simulation and new approach for the study of polymer ageing

Carole MONCHY-LEROY - EDF R&D, Moret-sur-Loing; France

Patrice THÉROND - EDF SEPTEN, Villeurbanne; France

2011-B6-2

Condition assessment of transmission power cables

Edward GULSKI - onsite.hv.solutions AG, Luzern; Switzerland

Piotr CICHECKI, Johan J. SMIT - Delft University of Technology, Delft; The Netherlands

Frank De VRIES - Liandon, Alkmaar; The Netherlands

Jan PELLIS - Stedin, Rotterdam; The Netherlands

Frank WESTER - TenneT, Arnhem; The Netherlands

2011-B6-3

Development of external diagnosis for XLPE cable terminations

SUYAMA Hiroshi, KOHAMA Takaharu, MORISHITA Yukinobu - Chubu Electric Power Co., Inc., Nagoya; Japan

WATANABE Masao, NAGAYAMA Tadanori - Tohoku Electric Power Co., Inc., Sendai; Japan

ABE Kazutoshi, SUZUKI Hiroshi - J-Power Systems Corporation, Hitachi, Ibaraki; Japan

2011-B6-4

Ageing performance of the new type outdoor termination using composite insulator

IIDA Tomoo, SHIRO Tadahiko, TANIGOCHI Minoru - The Kansai Electric Power Co,. Inc., Osaka; Japan

HOMMA Hiroya - Central Research Institute of Electric Power Industry (CRIEPI), Yokosuka; Japan

INOUE Yoshiyuki, HAGISAWA Kazuhisa - J-Power Systems Corporation, Tokyo; Japan

2011-B6-5

Ageing UG systems: The SmartLife initiative

Hallvard FAREMO - SINTEF Energy Research, Trondheim; Norway

Frank De WILD - KEMA, Arnhem; The Netherlands

Éric DORISON - Électricité de France, Moret-sur-Loing; France

2011-B6-6

Improvement of an health index from ageing studies and field outcome

Benoît PULUHEN, Éric DORISON, Yves BRUMENT - EDF R&D, Moret-sur-Loing; France

2011-B7-1

US industry practices for MV cable fleet management

David LINDSAY, Matthew OLEARCZYK - EPRI, Charlotte, North Carolina; United States

2011-B7-2

Condition and life assessment of laminar dielectric cable systems through dissolved gas analysis based on field trials and extensive field data

Nirmal SINGH, Sandeep SINGH - DTE Energy, Detroit, MI; United States

Rommy REYES, Pierre LINOIS - RTE, Nanterre, Paris; France

Steve ECKROAD - EPRI, Charlotte, NC; United States

2011-B7-3

Condition monitoring of electrical cables using line resonance analysis (LIRA)

Franco Paolo FANTONI - Wirescan AS, Halden; Norway

2011-B7-4

Investigation of remained withstand voltage level and water tree degradation on aged and removed XLPE cable

TAKAHASHI Tosihiro, KURAISHI Takashi, TAKAHASHI Tsuguhiro, SUZUKI Hiroshi, OKAMOTO Tatsuki - Central Research Institute of Electric Power Industry (CRIEPI), Yokosuka; Japan

TANAKA Sachika, SHIRO Tadahiko, MATSUYA Yuuji - The Kansai Electric Power Co., Inc., Osaka; Japan

2011-B7-5

Evaluation results of PILC cables field aged 7 to 68 years

Vitaliy YAROSLAVSKY, Carlos KATZ - Cable Technology Laboratories, New Brunswick, NJ; United States

David LINDSAY, Matthew OLEARCZYK - Electric Power Research Institute, Charlotte, NC; United States

2011-B7-6

A study on the effect of performing VLF withstand tests on field aged degraded joints

Jean-François DRAPEAU, Simon BERNIER - Institut de recherche d'Hydro-Québec (IREQ), Varennes, Québec; Canada

Jacques CÔTÉ - Hydro-Québec Distribution, Montréal, Québec; Canada

2011-B8-1

Evaluation of PD measurements on MV cable systems by means of a web database

Frank PETZOLD - SebaKMT GmbH, Baunach; Germany

Steffen BÖTTCHER - FSG GmbH, Freital; Germany

2011-B8-2

Intelligent DTS and PD monitoring system for underground distribution network

KIM Juyong, CHO Jintae, SONG Ilkeun, LEE Jae-bong - KEPCO, Daejeon; Korea

CHOI Taesik - LS Cable Ltd, Anyang; Korea

2011-B8-3

Comparison of different methodologies to assess the lifetime of cable

Jean Christophe GARD, Karine BIC, Bernard POISSON - Silec Cable (General Cable), Montereau; France

Francisco ESPINOSA - General Cable, Manlleu, Barcelona; Spain

2011-B8-4

Optical PD detection in stress cones of HV cable accessories

Markus HABEL, Klaus VATERRODT, Gerd HEIDMANN - IPH - Institut "Prueffeld fuer elektrische Hochleistungstechnik" GmbH, Berlin; Germany

Wolfgang HABEL - Bundesanstalt fuer Materialforschung und -pruefung, Berlin; Germany

Ruben VOGELSANG, Werner WEISSENBERG, Oldrich SEKULA - Brugg Cables, Brugg; Switzerland

Daniel PEPPER - Beuth Hochschule fuer Technik, Berlin; Germany

Ronald PLATH - HPS Berlin, Berlin; Germany

Harald EMANUEL - Omicron, Klaus, Vorarlberg; Austria

2011-B8-5

PD monitoring of 132 kV XLPE cable outdoor terminations: Practical experience

Valentinas DUBICKAS, Andreas DERNFALK - STRI AB, Ludvika; Sweden

2011-B8-6

Critical review of three capacitor model for PD estimation in micro-voids of polymer insulated cables

Luigi TESTA - Techimp, Bologna; Italy

Andrea CAVALLINI, Gian Carlo MONTANARI - University of Bologna, Bologna; Italy

2011-B9-1

Continuous PD monitoring of HV XLPE cable lines

Wojciech KOLTUNOWICZ, Alija OBRALIC, Alexander BELKOV, Dietmar GISELBRECHT - Omicron Electronics, Klaus, Vorarlberg; Austria

2011-B9-2

The need for smart diagnostics in future smart grids - A practical example for MV cables

Peter Van der WIELEN - KEMA Nederland BV, Arnhem; The Netherlands

Fred STEENNIS - Eindhoven University of Technology, Eindhoven; The Netherlands

Denny HARMSEN - Alliander N.V., Arnhem; The Netherlands

Danny GELDTMEIJER - Enexis B.V., Rosmalen; The Netherlands

2011-B9-3

On-line partial discharges monitoring for MV cables with SCG - Practical experiences in the period 2007 to 2010

Fred STEENNIS, Ad KERSTENS - KEMA, Arnhem; The Netherlands

Theo Van RIJN, Piet SOEPBOER - Alliander, Arnhem; The Netherlands

Jan MOSTERD, Leon BOKMA - Westland Infra, Poeldijk; The Netherlands

Alfred ARTS - Enexis, Arnhem; The Netherlands

Nico Van DONK, Branko CARLI - Stedin, Rotterdam; The Netherlands

2011-B9-4

The thermo mechanical behavior of joints in MV cable systems exposed to high current loads

Fred STEENNIS - KEMA, Arnhem; The Netherlands

Piet SOEPBOER - Enexis, Arnhem; The Netherlands

Jan MOSTERD - Alliander, Arnhem; The Netherlands

Peter BUYS - Stedin, Rotterdam; The Netherlands

Piet OOSTERLEE - DELTA Netwerkbedrijf, Middelburg; The Netherlands

Leon BOKMA - Westland Infra, Poeldijk; The Netherlands

Ralf MEIER - Lovink Enertech, Terborg; The Netherlands

2011-B9-5

On-line PD spot testing and continuous monitoring for in service power cables - Techniques and field experiences

Malcolm SELTZER-GRANT, Lee RENFORTH, Ross MACKINLAY - HVPD Ltd, Manchester; United Kingdom

Denis DENISOV, Hubert SCHLAPP, Frank PETZOLD - SebaKMT, Baunach; Germany

2011-B9-6

Sensitivity assessment for field PD measurements for HV and EHV cable accessories via laboratory tests

Mark FENGER - Kinectrics Inc., Toronto, Ontario; Canada

Jody LEVINE - HydroOne Networks, Toronto, Ontario; Canada

2011-B10-1

Selecting the optimized conductor design

Riccardo BODEGA, Henk GEENE, Jos Van ROSSUM - Prysmian, Delft; The Netherlands

Ron Van den THILLARD - TenneT, Arnhem; The Netherlands

Jacco SMIT - Liandon, Alkmaar; The Netherlands

Mark Van VLIET - Joulz, Rotterdam; The Netherlands

2011-B10-2

Investigations into the design of EMF mitigation techniques

Matthieu CABAU, Nadja MARAZANOF, Frédéric LESUR, Nathalie BOUDINET, Anne CHAUVANCY, Rémi VATONNE - RTE, Paris; France

2011-B10-3

Development of cold-shrink HVCA in regard to the critical set of physical properties

Ivan JOVANOVIC, Milan UZELAC - G&W Electric Company, Blue Island, IL; United States

2011-B10-4

Evolution in method and performance for bonding the metal screen of UG HV power cable

David DUBOIS, Pierre MIREBEAU, Pascal STREIT - Nexans, Calais; France

NN NN - Silec Cable (General Cable), Montereau; France

MM MM - Prysmian, Sens; France

XX XX - RTE, Paris; France

YY YY - Électricité de France, Paris; France

2011-B10-5

Special bonding and earthing of cables for a 230 kV three phase system with four cables

Márcio COELHO - Procable Energia e Telecomunicações SA, Diadema, Sao Paulo; Brazil

Geraldo ALMEIDA - Techsys Tecnologia e Sistemas S/C Ltda, Santo André, Sao Paulo; Brazil

Luiz ZANETTA - University of Sao Paolo - USP, Sao Paolo; Brazil

2011-B10-6

Special sheath bonding system for HVAC cables

Heinrich BRAKELMANN, Tao DONG - University Duisburg-Essen, Duisburg; Germany

Volker WASCHK - nkt cables GmbH, Köln; Germany

2011-C1-1

15 year's experience of cold-shrinkable MV joints

Stéphane TOGNALI, Gérard LENCOT - Prysmian Câbles et Systèmes France, Gron; France

2011-C1-2

MV cable termination failure prevention: On-line diagnostic method application at ERDF

Thierry ESPILIT, Fabrice ZORZI - EDF R&D, Moret-sur-Loing; France

Roger TAMBRUN - ERDF Direction Réseau, Paris La Défense; France

2011-C1-3

Connection to MV cable aluminium screen

Christophe TOURCHER - EDF R&D, Moret-sur-Loing; France

Members of SYCABEL - SYCABEL, Paris; France

Roger TAMBRUN - ERDF, Paris La Défense; France

2011-C1-4

Experience with joint failures in new "smart grid" MV cable circuits

Jacco SMIT, Frank De VRIES - Liandon, Alkmaar; The Netherlands

Ger SEBREGTS - Liander, Arnhem; The Netherlands

2011-C1-5

Impact of filled-strand conductor on connector temperature for medium voltage joints

Thomas PARKER, Nigel R. HAMPTON - NEETRAC, Atlanta, GA; United States

2011-C1-6

Service experience and laboratory testing of MV XLPE cable accessories

Jan Tore BENJAMINSEN, Hallvard FAREMO, Sverre HVIDSTEN - SINTEF Energy Research, Trondheim; Norway

2011-C2-1

Cable with optimized screen sheath complex

Isabelle DENIZET, Cécile LELIEVRE, Bernard POISSON - Silec Cable (General Cable), Montereau; France

Rajae BENAKKI - General Cable, Manlleu, Barcelona; Spain

2011-C2-2

The influence of manufacturing technique to power frequency breakdown characteristics of XLPE power cable

YAN Mengkun, YANG Rongkai, MIAO Fugui - Quality Inspection and Test Center for Equipment of Electric Power, Wuhan, Hubei province; China

YANG Liming - State Grid Electric Power Research Institute, Wuhan, Hubei province; China

2011-C2-3

Improving distribution system reliability

Donald BAINBRIDGE - CitiPower & Powercor, Melbourne, Victoria; Australia

2011-C2-4

An enhanced TR-XLPE insulation for long life power cables

Paul CARONIA, Saurav SENGUPTA, Timothy PERSON - The Dow Chemical Company, Piscataway, NJ; United States

Steve CREE - Dow Europe GmbH, Horgen; Switzerland

2011-C2-5

Temperature factor impact on the cable service life of XLPE cable during the installation of cable accessories

LI Zhongqun, ZHAO Sen, WANG Wei - State Grid Electric Power Research Institute, Wuhan, Hubei province; China

LUO Jingsheng - Electric Power of Hangzhou, Hangzhou City; China

2011-C3-1

Non-destructive water-tree detection in XLPE cables

Willem BOONE - KEMA Nederland BV, Arnhem; The Netherlands

John DENSLEY - Arborlec Solutions, Mississauga; Canada

Sverre HVIDSTEN - SINTEF Energy Research, Trondheim; Norway

2011-C3-2

Tree-retardant crosslinked (TRXLPE) reduced insulation wall accelerated cable life test (ACLT) results

John T. SMITH III - General Cable Corporation, Scottsville, TX; United States

2011-C3-3

3 kHz accelerated growth of water trees in medium voltage extruded cables

Blandine HENNUY, Quentin DE CLERCK - Laborelec, Linkebeek; Belgium

Alain FRANÇOIS, Daniel TENRET - Ores, Louvain-La-Neuve; Belgium

Pieter LEEMANS, Joachim MARGINET - Eandis, Melle; Belgium

2011-C3-4

A new approach to avoid negative superposition errors for PD measurements on lengths of extruded power cable

Kay RETHMEIER, Alexander KRAETGE, Michael KRÜGER - Omicron, Klaus, Vorarlberg; Austria

2011-C3-5

A new method of adopting distributed PD measurement in series resonance frequency voltage resistance test of high voltage cable

ZHOU Lijun, JIANG Xiaojuan - Power Grid Inspection & Maintenance Company, SMEPC (Shanghai Municipale Electrical Power Company), Shanghai; China

2011-C3-6

Measuring partial discharges with enhanced noise reduction by use of multi-band PD bandpass filters

Kay RETHMEIER, Alexander KRAETGE, Michael KRÜGER - Omicron, Klaus, Vorarlberg; Austria

2011-C4-1

On-site testing with compact AC test-system at the first 500 kV XLPE cable project in South America

Andreas WEINLEIN, Gero SCHROEDER - Suedkabel GmbH, Mannheim; Germany

Harald GEYER - agea-kull ag, Derendingen; Switzerland

2011-C4-2

A methodology for the assessment of HVDC-XLPE cable insulation

Bertrand VISSOUVANADIN, Gilbert TEYSSEDRE, Séverine LE ROY, Christian LAURENT - Laboratoire LAPLACE, Toulouse; France

Isabelle DENIZET, Mohamed MAMMERI, Bernard POISSON - Silec Cable (General Cable), Montereau; France

2011-C4-3

On-line-monitoring of the conductor temperature in MV power cable production using ultrasonic diagnosis

Gregor BRAMMER, Armin SCHNETTLER - Institute for high voltage technologies, Aachen; Germany

2011-C4-4

Modern methods of installation and diagnostic testing of distribution power cables

Edward GULSKI - onsite.hv.solutions AG, Luzern; Switzerland

Frank De VRIES - Liandon, Alkmaar; The Netherlands

Piotr CICHECKI - onsite.hv.solutions Benelux B.V., Werkendam; The Netherlands

Johan J. SMIT - Delft University of Technology, Delft; The Netherlands

2011-C4-5

Challenges associated with the interpretation of dielectric loss data from power cable system measurements

Joshua PERKEL, Nigel HAMPTON - NEETRAC, Atlanta, GA; United States

Jean Carlos HERNANDEZ - Universidad de Los Andes, Mérida, Mérida; Venezuela

Jean-François DRAPEAU - Institut de recherche d'Hydro-Québec (IREQ), Montréal, Québec; Canada

John DENSLEY - Arborlec Solutions, Toronto, Ontario; Canada

2011-C4-6

Next generation 200 kV VLF field testing and diagnosing of high voltage power cables

Mohammad Eyad AL-SIBAI - High Voltage Inc., Copake, New York; United States

2011-C5-1

Progress in the field of nanodielectrics : potentiality for HV cable applications

Michel F. FRÉCHETTE - Institut de recherche d'Hydro-Québec (IREQ), Varennes, Québec; Canada

Arnaud ALLAIS, Lazhar KEBBABI - Nexans;

Jérôme CASTELLON - IES; France

Hugues COUDERC, Christele VANGA - ÉTS/IREQ; Canada

2011-C5-2

Effect of conductive inorganic filler on space charge characteristics in XLPE as a HVDC insulating material

MIZUNO Takehiko, TAKAHASHI Tohru - VISCAS Corporation, Ichihara, Chiba; Japan

HARADA Hiroshi, HAYASHI Nobuya, TANAKA Yasuhiro - Tokyo City University, Setagaya-ku, Tokyo; Japan

MAENO Takeshi - National Institute of Information and Communication Technolory, Koganei, Tokyo; Japan

2011-C5-3

Dielectric properties analysis of HDPE/SiO2 nanodielectric materials for future cable insulation

Jérôme CASTELLON, Laurent BANET, Ioana PREDA, Serge AGNEL, Alain TOUREILLE - Institut d'Électronique du Sud - Université Montpellier 2, Montpellier; France

Éric DAVID, Abdelkhalek SAMI - École de Technologie Supérieure - Université du Québec, Québec, QC; Canada

Michel F. FRÉCHETTE - Institut de recherche d'Hydro-Québec (IREQ), Québec, QC; Canada

2011-C5-4

Voltage stabilizing additive assessment in polyethylene insulation

Timothy PERSON, Bret NEESE - The Dow Chemical Company, Piscataway, NJ; United States

2011-C5-5

Dielectric response of polyethylene loaded with nano particules of Si02

Éric DAVID, Abdelkhalek SAMI - École de Technologie Supérieure - Université du Québec, Québec, QC; Canada

Michel F. FRÉCHETTE - Hydro-Québec's Research Institute, Québec, QC; Canada

2011-C5-6

PEA assessment of XLPE and semiconductive compounds for HVDC application: Measurements on plaques and mini-cables

Barry LENNON, Peter MORSHUIS - Delft University of Technology, Delft; The Netherlands

Timothy PERSON - The Dow Chemical Company, Piscataway, NJ; United States

Simon SUTTON - Dow Chemical Company Ltd, Staines; United Kingdom

2011-C6-1

Operation experience and further development of a high temperature superconducting power cable in the Long Island Power Authority grid

Frank SCHMIDT, Rainer SOIKA - Nexans Deutschland GmbH, Hannover; Germany

James MAGUIRE, Jie YUAN - American Superconductor Corporation, Devens, MA; United States

Shawn BRATT - Air Liquide Advanced Technologies US LLC, Newark, NJ; United States

Tom WELSH - Long Island Power Authority, Hicksville; United States

2011-C6-2

Development of 275 kV 3 kA HTS power cable

MUKOYAMA Shinichi, YAGI Masashi, YONEMURA Tokui, NOMURA Tomoya, TENG Jun - Furukawa Electric, Ichihara, Chiba; Japan

OHKUMA Takeshi, MARUYAMA Osamu - Superconductivity Resaerch Laboratory, Shinonome, Tokyo; Japan

AOKI Yuji - SWCC Showa Cable Systems, Sagamihara, Kanagawa; Japan

SAITOU Takashi - Fujikura, Sakura, Chiba; Japan

AMEMIYA Naoyuki - Kyoto University, Saikyo-ku, Kyoto; Japan

ISHIYAMA Atsushi - Waseda University, Shinjuku-ku, Tokyo; Japan

HAYAKAWA Naoyuki - Nagoya University, Chigusa-ku, Nagoya; Japan

2011-C6-3

A breakthrough in the development of long-length HTS cables with integrated FCL property

Irina MELNIK, Alex GESCHIERE - Alliander, Duiven; The Netherlands

Dag WILLÉN - nkt cables, Broendby; Denmark

Oleg CHEVTCHENKO - TU Delft, Delft; The Netherlands

2011-C6-4

Superconducting HVDC power cables: Concepts and potential

Rainer SOIKA, Erik MARZAHN, Frank SCHMIDT, Mark STEMMLE, Beate WEST - Nexans Deutschland GmbH, Hannover; Germany

Nicolas LALLOUET - Nexans France, Calais; France

2011-C6-5

HTS cable project in Yokohama

MASUDA Takato, YUMURA Hiroyasu, HIROTA Hirofumi - Sumitomo Electric Industries, Ltd., Osaka; Japan

HONJO Shoichi, HARA Tsukushi - Tokyo Electric Power Company, Yokohama; Japan

2011-C6-6

Novel grid concepts for urban area power supply

Mark STEMMLE - Nexans Deutschland GmbH, Hannover; Germany

Frank MERSCHEL - RWE Rheinland Westfalen Netz AG, Essen; Germany

Bernd R. OSWALD - Leibniz University of Hannover, Hannover; Germany

Mathias NOE - Karlsruhe Institute of Technology, Karlsruhe; Germany

2011-C7-1

Improvements of underground cable distribution systems in the area of Mexico City

Edgar ROBLES - Instituto de Investigaciones Electricas, Cuernavaca, Morelos; Mexico

Victor SIERRA - ECSA, Huixquilucan, Estado de México; Mexico

2011-C7-2

The research on temperature precision influenced by fiber loss based on distributed temperature system in cable monitoring

LIU Qianqian, WANG Wei, ZHAO Sen - WHVRI Power Electric Science and Technology Stock, Wuhan, Hubei province; China

2011-C7-3

Research on on-line temperature monitoring method for cable connector

XU Jun, SU Wenqun - Power Grid Inspection & Maintenance Company, SMEPC (Shanghai Municipale Electrical Power Company), shanghai; China

2011-C7-4

The necessity analysis of distributed fiber-optic temperature monitoring by Xiamen power cable alarm case study

YAN Youxiang, SU Xueyuan - Xiamen power Ultility, Xiamen, Fujian; China

XIAO Chuanqiang - SINDIA, Beijing; China

2011-C7-5

Low loss micro grid

Lars EFRAIMSSON, Johan ÅHMAN, Thomas CARLQVIST - Ericsson AB, Falun; Sweden

2011-C7-6

New characterization and design of power cables systems

Josu ORELLA, Jesus BESTEIRO, Virginia MACIAS - IBERDROLA, Bilbao; Spain

2011-C8-1

Factors affecting the optimal cable placement in duct banks or casings for best ampacity or power

Wael MOUTASSEM - University of Toronto, Ontario; Underground Systems Inc., New York, United States

George ANDERS - Kinectrics Inc., Toronto, Ontario; Canada

2011-C8-2

Finite element analysis of SIWO-KUL (trade mark) cables

Bruno WEIDER - Nexans Schweiz AG, Breitenbach; Switzerland

François COCHET - Nexans Suisse SA, Cortaillod; Switzerland

Yann BRETON - Nexans Research Center, Lyon; France

2011-C8-3

Current rating of cables installed in deep or ventilated tunnels

Éric DORISON - Électricité de France, Moret-sur-Loing; France

George ANDERS - Kinectrics Inc., Toronto, Ontario; Canada

2011-C8-4

Reduction in current carrying capacity due to cables crossing

Mohamed CHAABAN, Jean LEDUC - Institut de recherche d'Hydro-Québec (IREQ), Varennes, Québec; Canada

2011-C8-5

Research on ampacity testing for middle-voltage cross-linked polyethylene (XLPE) cable

CAI Chengliang, WANG Yongqin - Hubei Electric Power Testing and Research Institute, Wuhan, Hubei province; China

2011-C8-6

Research of upgrading ampacity for high voltage XLPE power cable

FAN Youbing, ZHAO Jiankang, LIU Songhua, MENG Shaoxin, RAO Wenbin - State Grid Electric Power Research Institute, Wuhan, Hubei province; China

2011-C9-1

Statistical feedback approach in cyclic rating factor sizing

Irina GARZULINO, Nicolas POUPARDIN, Anne CHAUVANCY, Frédéric LESUR, Xavier ROLLAND-NEVIERE - RTE, Paris; France

2011-C9-2

Dynamic rating of transmission cables

Erik JACOBSEN, Jonas Fabricius NIELSEN, Steen Beck NIELSEN - SEAS-NVE Holding, Haslev; Denmark

Sven SALWIN - nkt cables A/S, Copenhagen; Denmark

Karl-Heinz COHNEN, Andreas MOHRS - nkt cables GmbH, Köln; Germany

2011-C9-3

On-line ampacity determination of a 220 kV cable using an optical fibre based monitoring system

Michael SCHMALE - TenneT TSO GmbH, Bayreuth; Germany

Ralf PUFFER - RWTH Aachen University, Aachen; Germany

Ulrich GLOMBITZA - OSSCAD GmbH & Co. KG, Bergisch Gladbach; Germany

Henrik HOFF - AP Sensing GmbH, Boeblingen; Germany

2011-C9-4

Feasibility study report on dynamic cable rating system retrofitted to the existing 138 kV XLPE cable system

IGI Tsuyoshi, KOMEDA Hidehiko - J-Power Systems Corporation, Hitachi, Ibaraki; Japan

MASHIO Shoji - J-Power Systems Corporation, Tokyo; Japan

Jade WONG, Arnold WONG - ConEdison, New York, NY; United States

2011-C9-5

Real time load optimisation of cable based transmission grids

Rasmus Schmidt OLSEN, Unnur Stella GUDMUNDSDÓTTIR - Energinet.dk, Fredericia; Denmark

Joachim HOLBOELL - Technical University of Denmark, Kongens Lyngby; Denmark

2011-C9-6

Impact of moisture migration on the current rating of high operating temperature cables

James PILGRIM, David SWAFFIELD, Paul LEWIN - University of Southampton, Southampton; United Kingdom

Steve SWINGLER - Southampton Dielectric Consultants, Southampton; United Kingdom

Francis WAITE, David PAYNE - National Grid, Warwick; United Kingdom

2011-C10-1

Investigation into the benefits of installing high operating temperature cables in tunnels

James PILGRIM, David SWAFFIELD, Paul LEWIN - University of Southampton, Southampton; United Kingdom

Steve SWINGLER - Southampton Dielectric Consultants, Southampton; United Kingdom

Francis WAITE, David PAYNE - National Grid, Warwick; United Kingdom

2011-C10-2

A new backfill material with an extremely high thermal conductivity

Heinrich BRAKELMANN, Joerg STAMMEN - University Duisburg-Essen, Duisburg; Germany

Joerg DIETRICH - HeidelbergCement Geotechnik, Ennigerloh; Germany

Raymund BÖING - Heidelberg Beton, Heidelberg; Germany

Hans-Peter MAY - nkt cables GmbH, Köln; Germany

2011-C10-3

Backfill replacement saves underground transmission lines cost and postpones investments

Geraldo de ALMEIDA, Luis ZANETTA - University of Sao Paolo - USP, Sao Paolo; Brazil

Athayde MACEDO, Carla DAMASCENO - Ligth SESA, Rio de Janeiro; Brazil

2011-C10-4

Improved cooling of high voltage cables

Herbert NYFFENEGGER, Detlef WALD - Brugg Kabel AG, Brugg; Switzerland

Harry ORTON - Orton International Consulting, Vancouver, BC; Canada

2011-C10-5

Hybrid high capacity transmission circuits - Challenges for cables in series with EHV overhead lines

Glenn STAPLETON - Powerlink Queensland, Virginia, Queensland; Australia

Simon LLOYD - Cable Consulting International, Kent, WA; United Kingdom

2011-D1-1

Simulation of life cycle costing analysis to evaluate project of installation high voltage undersea cable 150 kV circuit III and IV Java-Bali

Ngapuli SINISUKA - Bandung Institute of Technology (ITB), Bandung; Indonesia

Iqbal FELANI, Novrizal ERDIANSYAH - Electricity Utility Company (PLN), Jakarta; Indonesia

2011-D1-2

Technical-economic analysis using aluminum instead of copper conductor for medium voltage cables and the practice in Zhejiang, China power grid

XUAN YuLong, SHAO XueJian - Hangzhou Electric Power Bureau, Hangzhou City; China

JIANG Wendong - Zhejiang Provincial Electric Power Bureau, Hangzhou City; China

2011-D1-3

Whole-life costs and environmental assessment of high voltage power cable systems

Gary STEVENS, Ben PHILPOT, Janet THOMAS - GnoSys UK Ltd, Guildford; United Kingdom

Ankit GOWADIA, Mike FAIRHURST - National Grid, Warwick; United Kingdom

2011-D1-4

Modern 3-core MV XLPE cables and their impact on TCO

Håkan BRINGSELL, Lars EFRAIMSSON, Thomas CARLQVIST - Ericsson AB, Falun; Sweden

2011-D1-5

Economical design of cable conductors

Frédéric LESUR, Victor LEJOUR - RTE, Paris; France

2011-D1-6

Overall cost comparison between cable and overhead lines including the costs for repair of random failures

Roberto BENATO - University of Padova, Padova; Italy

Domenico NAPOLITANO - Free Lance, Venezia; Italy

2011-D2-1

Monitoring facilities for outage reduction of 380 kV power cables

Sander MEIJER - TenneT TSO bv, Arnhem; The Netherlands

Johan J. SMIT - Delft University of Technology, Delft; The Netherlands

Rogier JONGEN - Seitz Instruments AG, Niederrohrdorf; Switzerland

Edward GULSKI - onsite.hv.solutions AG, Luzern; Switzerland

2011-D2-2

Development of the electric potential method for HPFF cable systems

NISHIKAWA Tsuyoshi, AIHARA Yasuhiko, TSUCHIYA Shinichi - Tokyo Electric Power Company, Chiyoda-ku, Tokyo; Japan

2011-D2-3

Underground cables maintenance and repair

Patrick DELCOURT, Joël BOUYER - RTE, Paris; France

2011-D2-4

Development of a simple method for condition assessment of oil filled XLPE terminations

Knut Brede LILAND, Sverre HVIDSTEN - SINTEF Energy Research, Trondheim; Norway

Geir BIRKENES, Frank MAUSETH - Department of Electric Power Engineering, NTNU, Trondheim; Norway

Eilert BJERKAN - Nortroll AS, Levanger; Norway

2011-D2-5

REE's power cable maintenance program

Rafael GARCÍA FERNÁNDEZ, Miguel Ángel PÉREZ LOUZAO - Red Eléctrica de España, S.A., Madrid; Spain

2011-D2-6

Materials and test methods for power cables exposed to heavy operating conditions

Christian CORNELISSEN - Nexans Deutschland, Moenchengladbach; Germany

2011-D3-1

Application of artificial intelligence to the problem of selecting the appropriate diagnostic for cable systems

Yamille DEL VALLE, Nigel HAMPTON - NEETRAC, Atlanta, GA; United States

2011-D3-2

Implementation of low and medium voltage cable ageing management at nuclear power plants

Gary TOMAN - Electric Power Research Institute, Charlotte, NC; United States

2011-D3-3

New technique for fault location in underground medium voltage cable

Lionel REYNAUD, Daniel PINEAU - Institut de recherche d'Hydro-Québec (IREQ), Varennes, Québec; Canada

Jacques CÔTÉ - Hydro-Québec Distribution, Montréal, Québec; Canada

2011-D3-4

Implementation of modern methods of on-site testing and diagnosis of HV power cables

Edward GULSKI - onsite.hv.solutions AG, Lucerna; Switzerland

Aleksandra RAKOWSKA, Krzysztof SIODLA - Poznan University of Technology, Poznan; Poland

Piotr CICHECKI - onsite.hv.solutions Benelux B.V., Delft; The Netherlands

Laurens D. POTS - BV Twentsche Kabelfabriek, Haaksbergen; The Netherlands

Johan J. SMIT - Delft University of Technology, Delft; The Netherlands

2011-D3-5

Hydro-Québec experience with infrared imaging for the maintenance of the underground medium voltage cable system

Jacques CÔTÉ, André BELLEMARE - Hydro-Québec, Montréal, Québec; Canada

2011-D3-6

Investigation into the downtown Vancouver outage of 14 july 2008

Khaled ABDOLALL, John VANDERMAAR - Powertech Labs Inc., Surre, BC; Canada

Dexter TARAMPI - BC Hydro, Vancouver, BC; Canada

2011-D3-7

Condition based maintenance of LV cable network of public lighting

Zoltán Ádám TAMUS, Norbert FEKETE - Budapest University of Technology and Economics, Budapest; Hungary

Tamás SCHACHINGER, Róbert EGYED - GA Hungary Ltd., Törökbalint; Hungary

2011-D4-1

Collective versus individual screening of "wet design" (Um <= 36 kV) power cores for multi-core cables

Jarle J BREMNES - Nexans Norway AS, Halden; Norway

Hallvard FAREMO - SINTEF Energy Research, Trondheim; Norway

2011-D4-2

Analysis of transmission capacity of Zhoushan-mainland 110 kV submarine cables

WU Mingxiang - Zhejiang Provincial Electric Power Test and Research Institute, Hangzhou City; China

2011-D4-3

The Hawon-Anjwa project: Development and installation of the AC 154 kV XLPE 3 cores fiber optic embedded submarine power cable system

KIM Nam-yu, KIM Sung-yun, JEON Seung-ik, KWUN Young-guk, LEE Kwang-yeol - LS Cable Ltd, Gumi, Gyeongbuk; Korea

2011-D4-4

Water drop discharges and surface flashover at the solid - solid interface of submarine connectors

Seyed Majid HASHEMINEZHAD, Erling ILDSTAD - Department of Electric Power Engineering, Norwegian Univ. of Technology and Science, Trondheim; Norway

2011-D4-5

The Oslo fjord project - The first project with long length 420 kV XLPE insulated submarine cables

Tor SKEIE, Jostein ELDERS, Alf Erik RØD - Nexans Norway AS, Halden; Norway

Bjørn SANDEN, Jørgen THON - Statnett, Oslo; Norway

2011-D4-6

Qualification of a long 345 kV submarine XLPE cable system

Johan KARLSTRAND, Danijela PALMGREN, Jörn ANTONISCHKI, Jonas JOHANSSON, Björn ZETTERVALL - ABB, Karlskrona; Sweden

2011-D6-1

Ultra low weight combined LV/FO cable for steep cable car pathway

Boris DARDEL, Marc BRESSENEL, Jean WITTWER, François COCHET - Nexans Suisse SA, Cortaillod; Switzerland

2011-D6-2

Influence of the additives on the water-treeing in XLPE insulated cables

Emeric LONG, Isabelle DENIZET, Bernard POISSON - Silec Cable (General Cable), Montereau; France

Elisenda CASALS - General Cable, Manlleu, Barcelona; Spain

2011-D6-3

Reliability evaluation of distribution cable diagnosis instruments with field test

PARK Noh-joon - Center for Advanced Electric Application, Wonkwang University, Iksan, Jeonbuk; Korea

PARK Dae-hee - Dept. of Electrical, Information & Communication Engineering, Wonkwang University, Iksan, Jeonbuk; Korea

2011-D6-4

The application of optical fiber composite low-voltage cable (OPLC) in smart grid of China

BAO Jicong, QIAO Xinxia, QIAN Ziming - Jiangsu Hengtong Power Cable Co., Ltd, Wujiang City, Jiangsu Province; China

2011-D6-5

Insulation state analysis and upgrading feasibility study of existing AC 10 kV XLPE distribution cables in Jiangsu grid of China

ZHANG Ziyang, FEI Yijun - Jiangsu Electric Power Research Institute Corporation LTD, Nanjing, Jiangsu; China

2011-D6-6

70 years of MV cables in Brazil: Reliability of cables, splices and potheads

Geraldo de ALMEIDA, Luiz ZANETTA - University of Sao Paolo - USP, Sao Paolo; Brazil

Ricardo BRANDÃO - AES Eletropaulo, Sao Paolo; Brazil

Walter PINHEIRO - Matrix Engenharia, Sao Paolo; Brazil

2011-E5-1-1

Effects of cross-linking method on insulation properties of cross-linked polyethylene

ZHU Xiao-hui, ZHOU Feng-zheng - Tianjin Electrical Power Research Institute, Tianjin; China

DU Bo-xue, GAO Yu - School of Electrical Engineering and Automation, Tianjin University, Tianjin; China

2011-E5-1-2

The effect of the peroxide ratio on crosslinking of cable materials

Amin SHABANI, Emmanuel RICHAUD, Xavier COLIN - Arts et Métiers ParisTech, Paris; France

Gregory MARQUE, Carole MONCHY-LEROY - EDF R&D, Moret-sur-Loing; France

2011-E5-1-3

Study of the stabilization of polyethylene and ethylene-propylene copolymers by a phenolic antioxydant

Wissam BANNOUF, Emmanuel RICHAUD, Xavier COLIN - Arts et Métiers ParisTech, Paris; France

Grégory MARQUE, Carole MONCHY-LEROY - EDF R&D, Moret-sur-Loing; France

2011-E5-1-4

Electric properties of XLPE model cables under AC and DC field at various temperatures

Le WANG, Davide FABIANI, Gian Carlo MONTANARI, Fabrizio PALMIERI - University of Bologna, Bologna; Italy

Ulf. H. NILSSON - Borealis AB, Stenungsund; Sweden

2011-E5-1-5

A new method for monitoring the antioxidant content in cable compounds during e-beam crosslinking

Matthias MEYER, Inge DUEMMLER - Nexans Research Center, Nuremberg; Germany

2011-E5-1-6

Development of a diagnosis technique for assessing the properties of nuclear aged cables

Domitille PITARD, Carole MONCHY-LEROY - EDF R&D, Moret-sur-Loing; France

Patrice THÉROND - EDF SEPTEN, Villeurbanne; France

2011-E5-1-7

Rapid qualification of power cables materials

Henryk HERMAN, Gary STEVENS, Janet THOMAS - GnoSys UK Ltd, Guildford; United Kingdom

2011-E5-1-8

The effect of water ingress on dielectric properties of polyethylene cable insulation

Simon BERNIER, Jean-François DRAPEAU - Institut de recherche d'Hydro-Québec (IREQ), Varennes, Québec; Canada

Éric DAVID - École de Technologie Supérieure - Université du Québec, Montréal, Québec; Canada

2011-E5-1-9

Analysis of the resistivity loss of aged PVC cables and effects on their dielectric strength

Pierre QUENNEHEN, Fabrice ZORZI, Thierry ESPILIT - EDF R&D, Moret-sur-Loing; France

Patrice THÉROND - EDF SEPTEN, Villeurbanne; France

Isabelle ROYAUD, Gérard SEYTRE - IMP/LMPB Université Lyon 1, Villeurbanne; France

Pascal RAIN - G2ELab, Grenoble; France

2011-E5-1-10

Evaluation of field rejuvenated medium-voltage extruded cables

Serge PÉLISSOU, Saleman ALIBHAY - Institut de recherche d'Hydro-Québec (IREQ), Varennes, Québec; Canada

2011-E5-1-11

Study on the maintenance policy based on RCM for power cable lines

ZHAO Jiangkang, LUO Junhua - State Grid Electric Power Research Institute of China, Wuhan, Hubei province; China

ZHANG Li - Power Grid Inspection & Maintenance Company, SMEPC (Shanghai Municipale Electrical Power Company), Shanghai; China

LI Honglei - East China Electric Power Test & Research Institute Co., Ltd., Shanghai; China

2011-E5-1-12

Underground cable description data management

Patrick DELCOURT, Joël BOUYER - RTE, Paris; France

2011-E5-1-13

Replacement strategies for customer minutes lost reduction in medium voltage cable networks

Peter BUYS, Dik Van HOUWELINGEN, Edward COSTER - Stedin BV, Rotterdam; The Netherlands

2011-E5-1-14

Evaluation of insulating systems quality for HVDC power cable design toward space charge criterion

Jérôme CASTELLON, Serge AGNEL, Alain TOUREILLE - Institut d'Électronique du Sud - Université Montpellier 2, Montpellier; France

Arnaud ALLAIS, Lorrene BAYON - Nexans Research Center, Lyon; France

2011-E5-1-15

On-line diagnostic system for SVL device on underground power cables

MYUNG Keun-Sik, YOON Huyng-hee, KIM Heung joo - KEPCO, Seoul; Korea

JEONG Jae ki, JEONG Yun-kee, CHOI Yun-Jong - HanbitEDS Co. Ltd, DaeJeon; Korea

2011-E5-2-1

Partial discharges (PD) automatic diagnosis tool for workers' safety in underground vaults

François LÉONARD, Lionel REYNAUD, Jacques BHERER, Daniel PINEAU, Didier MUSSARD, Sylvain POIRIER - Hydro-Québec, Québec, QC; Canada

2011-E5-2-2

Temperature dependency of tan delta measurements at 0.1 Hz in XLPE medium voltage power cables

Cuthbert NYAMUPANGEDENGU - University of the Witwatersrand, Johannesburg; South Africa

Jerry WALKER - Walmet Technologies (Pty) Ltd, Vereeniging; South Africa

2011-E5-2-3

Partial discharges pattern characteristics of 220 kV XLPE power cable joints with artificial defect

ZHANG Xuejin, PAN Leilei - Shanxi Taiyuan Electric Power Supply Company, Taiyuan; China

LUO Junhua, LI Wenjie, XIA Rong - State Grid Electric Power Research Institute, Wuhan, Hubei province; China

2011-E5-2-4

High frequency signal propagation in solid dielectric tape shielded power cables

Jun (Jim) GUO, Rick STAGI - Utilx Corporation, Kent, WA; United States

2011-E5-2-5

Dependency of the dissipation factor on the test-voltage and the ageing status of MV PILC cables

Ivana MLADENOVIC, Christian WEINDL - University of Erlangen-Nuremberg, Institute of Electrical Power Systems, Erlangen; Germany

2011-E5-2-6

A novel anti-interference method for partial discharges on-line measurement of HV power cables

LI Wenjie, LUO Junhua, ZHAO Jiankang, XIA Rong, MENG Shaoxin - State Grid Electric Power Research Institute, Wuhan, Hubei province; China

ZHANG Xuejin, PAN Leilei - Shanxi Taiyuan Electric Power Supply Company, Taiyuan; China

2011-E5-2-7

Electrical trees and partial discharges degradation characteristics in XLPE cable insulation at high temperature

FENG Yi - Beijing Electric Test and Research Institute, Beijing; China

CHEN Xiangrong, XU Yang, CAO Xiaolong - State Key Laboratory of Electrical Insulation and Power Equipment, Xi'an Jiaotong University, Xi'an; China

2011-E5-2-8

VLF tan-delta measurement on submarine cables in KEPCO

LEE Jae-bong, JUNG Yeon-ha - KEPCO Research Institute, Daejeon; Korea

KIM Sung-min, KWON Tae-joon - KEPCO Head Office, Seoul; Korea

2011-E5-2-9

Partial discharges feature selection and evaluation using an enhanced recursive feature elimination (RFE) algorithm

Jean Carlos HERNÁNDEZ, Jesús VELAZCO - Universidad de Los Andes, Mérida, Mérida; Venezuela

Joshua PERKER - Georgia Institute of Technology, Atlanta, GA; United States

2011-E5-2-10

Investigation of power frequency current transformer as partial discharges sensor in medium voltage cables

Faisal PEER MOHAMED, Wah Hoon SIEW, John SORAGHUN, Scott STRACHAN - University of Strathclyde, Glasgow, Scotland; United Kingdom

2011-E5-2-11

A new lumped model for electrical treeing in XLPE cable insulations

Abbas NAJAFIPOUR, Sayyed Mohammad SHAHRTASH - Iran University of Science and Technology (IUST), Tehran; Islamic Republic of Iran

2011-E5-2-12

PD signal compensation in cable terminals and classification for HV cable insulation assessment

Mohsen BAKHSHI ASHTIANI, Mohammad SHAHRTASH - Iran University of Science and Technology (IUST), Tehran; Islamic Republic of Iran

2011-E5-2-13

Pulse signal propagation characteristics on the aged XLPE cable

TAKAHASHI Tosihiro, KURAISHI Takashi, TAKAHASHI Tsuguhiro, SUZUKI Hiroshi, OKAMOTO Tatsuki - Central Research Institute of Electric Power Industry (CRIEPI), Yokosuka; Japan

2011-E5-2-14

Equipment for fast water trees resistance measurement of power cable insulations

Sorin GRIGORESCU, Mihai Gabriel PLOPEANU, Petru NOTINGHER - Politehnica University of Bucharest, Bucharest; Romania

Cristina STANCU - INCDIE ICPE CA, Bucharest; Romania

2011-E5-2-15

VLF tan-delta criteria for XLPE insulated power cables in KEPCO

LEE Jae-bong, JUNG Yeon-ha - KEPCO Research Institute, Daejeon; Korea

KIM Sung-min, KWON Tae-joon - KEPCO Head Office, Seoul; Korea

2011-E5-2-16

Experiences of diagnosis of HV cables with damped AC technique

Zoltán Ádám TAMUS, Richárd CSELKÓ - Budapest University of Technology and Economics, Budapest; Hungary

Tamás SCHACHINGER, Róbert EGYED - GA Hungary Ltd., Törökbalint; Hungary

2011-E5-2-17

Thermal step method - A non-destructive tool for lifetime estimation of treed cables insulation

Cristina STANCU - INCDIE ICPE CA, Bucharest; Romania

Petru NOTINGHER JR. - Universite Montpellier 2, Institut d'Électronique du Sud, Groupe Énergie et Matériaux, Montpellier; France

Petru V. NOTINGHER, Mihai Gabriel PLOPEANU - Politehnica University of Bucharest, Bucharest; Romania

2011-E7-1-1

The application of the Y-branch joints in TEPCO

WATANABE Kensuke, AIHARA Yasuhiko, TSUCHIYA Shinichi - Tokyo Electric Power Company, Chiyoda-ku, Tokyo; Japan

2011-E7-1-2

Environmentally sound lead-free insulation material for medium voltage energy cables

Amalendu SARKAR, John T. SMITH, III - General Cable Corporation, Indianapolis, Indiana; United States

2011-E7-1-3

Distribution of peroxide by-products along degassed XLPE HV cables

Christian ANDERSSON - Ericsson AB, Falun; Sweden

Martin JAKOBSSON, Annika SMEDBERG, Jan-Ove BOSTRÖM - Borealis AB, Stenungsund; Sweden

2011-E7-1-4

XLPE for medium and high voltage cables insulation: Determination of organic peroxide's decomposition products by the most suitable analysis

Alfredo DEFRANCISCI, Sandra GRIMALDI, Edwin-Jeoffrey COURTIAL - ARKEMA Centre de Recherche Rhône-Alpes, Pierre-Bénite; France

2011-E7-1-5

Prototype for detection of delaminations in the sheath system of high voltage power cables using ultrasonic diagnosis

Gregor BRAMMER, Armin SCHNETTLER - Institute for high voltage technologies, Aachen; Germany

2011-E7-1-6

Photoacoustics: An approach for on-line process control of degassing XLPE insulated high voltage cables

Hans BETTERMANN, Thomas GRETHE - Heinrich-Heine University of Duesseldorf, Duesseldorf; Germany

Anika BOSSE, Volker WASCHK - nkt cables GmbH, Köln; Germany

2011-E7-1-7

The research on XLPE cable insulation based on ground current method on-line monitoring technique

GU yonggang, ZHONG Pengjiao - WHVRI Power Electric Science and Technology Stock, Wuhan, Hubei province; China

WANG Wei - State Grid Electric Power Research Institute, Wuhan, Hubei province; China

2011-E7-1-8

A versatile system for electrical treeing tests under AC and DC stress using wire electrodes

Anette JOHANSSON, Stanislaw GUBANSKI, Markus JARVID, Mats ANDERSSON - Chalmers University of Technology, Gothenburg; Sweden

Björn SONERUD - Nexans Norway AS, Halden; Norway

Villgot ENGLUND - Borealis AB, Stenungsund; Sweden

Andreas FARKAS - ABB AB, Karlskrona; Sweden

2011-E.7.1.9

Experimental study on detection equivalence of partial discharges at damped AC voltages and 50 Hz AC voltages in 110 kV XLPE power cables

XIA Rong, ZHAO Jiankang - State Grid Electric Power Research Institute, Wuhan, Hubei province; China

Edward GULSKI - Delft University of Technology, Delft; The Netherlands

2011-E7-1-10

Partial discharges test and disassembly analyze of cable termination in Huanghoudian, Beijing

ZHAO Yu, LI Huachun, HUANG Heming, XUE Qiang - Power Cable Company of Beijing Electric Power Corporation, Beijing; China

JIANG Xiaoying - BeiJing Electric Power Cable Company, Beijing; China

2011-E7-1-11

Power frequency magnetic field test and analyse of HV cables in tunnel

LI Huachun, WANG Li, LIU Hao - BeiJing Electric Power Cable Company, Beijing; China

GUO Jianfu, ZHANG Wenxin - BeiJing Electric Power Cable Company, Beijing; China

2011-E7-1-12

Negative k-factor setting for power cables explained via sequence impedance measurements

Wernich DE VILLIERS, Ulrich KLAPPER - Omicron, Klaus, Vorarlberg; Austria

2011-E7-1-13

Various cable terminal defect types and environmental factors impact on the results of PD tests

TU Na, WANG Wei - WHVRI Power Electric Science and Technology Stock, Wuhan, Hubei province; China

2011-E7-1-14

Frequency characteristics of partial discharges in MV extruded cables using non-conventional sensors

LEE Young-jo, KIM Jong-yeol, SEO In-jin, KOO Ja-yoon - Hanyang University, Ansan, Gyeong-Gi; Korea

JEONG Jae-cheol, KIM Jeong-tae - Daejin University, Phochon, Gyeong-Gi; Korea

2011-E7-1-15

PD monitoring system of HV cables

Miguel Ángel SÁNCHEZ URÁN, Fernando GARNACHO VECINO, Javier ORTEGO, Jorge MORENO, Fernando ÁLVAREZ, Oscar PERPIÑAN - Polytechnik University of Madrid, Madrid; Spain

Julio GONZALO GARCÍA, José Luis VALLEJO DIEZ - GasNatural Fenosa, Madrid; Spain

2011-E7-1-16

Using after installation commissioning tests to assure power cable systems meet manufacturers' standards

Stefaan JESPERS - Cegelec, Brussels; Belgium

Massimo VANOSSI - Foster Wheeler Italiana, Corsico, Milan; Italy

Marco GREEN - IMCORP, Rendsburg; Germany

Benjamin LANZ - IMCORP, Manchester, Connecticut; United States

2011-E7-2-1

Silicone technology for reliable performance of joints and terminations for high voltage polymer power cables

Ruben VOGELSANG, Hansjörg GRAMESPACHER - Brugg Cables, Brugg; Switzerland

Hans-Jörg WINTER, Martin GRUNWALD - Wacker Chemie AG, Brughausen; Germany

2011-E7-2-2

Improving surface smoothness of semi conductive shields by blending ethylene copolymers

Laurent GERVAT, Sébastien QUINEBECHE - ARKEMA, Serquigny; France

Oliver HISSMANN - OCS, Witten; Germany

2011-E7-2-3

Influence of voids within electric fields in HVDC cables

Sebastián GUTIERREZ, Sancho IÑAKI, Luis FONTAN, Jose MALUMBRES - CEIT and Tecnun (University of Navarra), San Sebastián, Gipuzkoa; Spain

2011-E7-2-4

Investigation of the life curve for high voltage cable insulation

Mikhail Y. SHUVALOV, Vladimir L. OVSIENKO - Russian Cable Scientific Research and Development Institute (VNIIKP), Moscow; Russia

2011-E7-2-5

Selection research of protection earthing set-up of HV cable

ZHOU Li, ZHOU Zhicheng - Jiangsu Electric Power Research Institute Corporation LTD, Nanjing, Jiangsu; China

JI Wenlu - Nanjing Power Supply Company, Nanjing, Jiangsu; China

2011-E7-2-6

The investigation and application of multi-state monitoring system to high voltage cables and tunnels

ZHOU Zuochun, ZHANG Yanyan - Beijing Electric Test and Research Institute, Beijing; China

CONG Guang - BeiJing Electric Power Cable Company, Beijing; China

WANG Li, XUE Qiang, LI Huachun - Power Cable Company of Beijing Electric Power Corporation, Beijing; China

ZHANG Wenxin - Beijing Power Engineering Company, Beijing; China

2011-E7-2-7

AC withstand voltage test of 345 kV cable system

KIM Jae-seung, MIN Byeong-wook, KIM Tai-young - KEPCO, Seoul; Korea

2011-E7-2-8

Voltage stabilizers for XLPE cable insulation

Thomas HJERTBERG, Villgot ENGLUND - Borealis AB, Stenungsund; Sweden

2011-E7-2-9

Development and construction of 345 kV Power-Optical Fiber Composite XLPE 2500 mm2 with prefabricated joints

YOON Hyung-hee, PAIK Nam-yeol, LEE Koan-seong, KIM Soo-hwan, OH Jong-ok, LEE Seung-hyun - Korea Electric Power Corporation (KEPCO), Seoul; Korea

2011-E7-2-10

Study and application of cable network operation monitoring system in Beijing

WANG Li, LI Huachun, XUE Qiang - BeiJing Electric Power Cable Company, Beijing; China

ZHOU Zuochun, CONG Guang - BeiJing Electric Power Cable Company, Beijing; China

2011-E7-2-11

High temperature silicone elastomers for rolling stock cables

Bernard DALBE - Nexans Research Center, Lyon; France

2011-E7-2-12

Electrical, thermal and thermo-mechanical design of MV XLPE cables

Rohini BHATTACHARYYA - Dubai Cable Company Pvt. Ltd. (Ducab), Dubai; UAE

2011-E7-2-13

Study of 500 kV cable terminal insulation structure

WANG Wei, ZHAO Sen, LI Zhongqun - State Grid Electric Power Research Institute, Wuhan, Hubei province; China

WANG Xixing - WHVRI Power Electric Science and Technology Stock, Wuhan, Hubei province; China

2011-E7-2-14

Multiconductor cell analysis of shunt compensated cable lines

Roberto BENATO - University of Padova, Padova; Italy

2011-E7-2-15

Optimal design for power cable metal sheath voltage compensation device

WANG Guangming, ZHANG Xing, WANF Donghai, WANG Chunning - Nanjing Power Supply Company, Nanjing, Jiangsu; China

MA Hongzhong - HoHai University, Nanjing, Jiangsu; China

2011-E7-2-16

Sequence impedance computation by means of multiconductor method

Roberto BENATO, Leandro CACIOLLI, Ernesto ZACCONE - Prysmian Powerlink, Milan; Italy

2011-E7-2-17

Implementation of cable models for studies of compatibility of electric components in wind farms

Andrzej HOLDYK, Joachim HOLBOELL - Technical University of Denmark, Department of Electrical Engineering, Kongens Lyngby; Denmark

2011-E7-2-18

Performance tests on large conductors connectors

François GAHUNGU, Pierre MIREBEAU - Nexans, Calais; France

Pascal STREIT - Nexans, Cossonay; Switzerland

2011-E7-2-19

Performance analysis of optical fiber composite low-voltage cable

ZHANG Ye, CHEN xi, ZHAO daping, QI Liyan, HOU Jiyong, LIU Hao, WANG Peng, AN Huirong, WANG Shuling, JIA Meijian, XU Gaoxiong, FENG Xuebin - China Electric Power Research Institute, Beijing, Haidian; China

2011-E7-2-20

EMF mitigation using steel pipes : Effect on cable thermal rating

Thierry BOUCHER, Éric DORISON - EDF R&D, Moret-sur-Loing; France

2011-E7-2-21

P-Laser: 10.000 km of installed cables based on a worldwide new technology

Sergio BELLI, Gabriele PEREGO, Luigi CAIMI, Alberto BAREGGI, Vincenzo CRISCI, Giovanni POZZATI, Stefano FRANCHI, Marco ALBERTINI, Fabrizio DONAZZI, Ernesto ZACCONE, Agusti VALLS - Prysmian S.p.A., Milan; Italy

In your agenda

JICABLE'15

June 2015

ARCHIVES