JICABLE : All proceedings
From Jicable'84 to Jicable'07
Please find herafter, the list of all proceedings from Jicable '84 to the last conference Jicable'07
RESEARCH : You may use the "search on this page" property of your browser to locate a relevant proceeding according to key words (limited to this page).
The first page of the proceeding is associated with the link
A search function is also available. It searches within the whole first page of all proceedings.
A full pdf version of any proceeding could be sent free of charges, upon nominative request by mail.
Low-voltage overhead networks and trappings using insulated conductors
PARIS Michel, SCHWAB Anne-Marie; EDF-DER; Clamart, France
Insulated cables for aerial networks with A.C. rated voltages up to 1 kV Specifications and installation rules
BECKER J., BOURJOT P, GASPARINI G.; Câblerie de Charleroi - CDC; Charleroi, Belgique
BORRAS FIGUERAS Tomas; SAENGER; Barcelona, Spain
BOURJOT Pierre; CEAT; Poissy, France
GASPARINI Georgio; CEAT CAVI; Torino, Italy
Distribution cables at Electricité de France. Technological evolutions of cables and accessories
SCHMELTZ Jacques; EDF Direction de la Distribution; Paris la Défense, France
FERRAN Jacques, LOUET Maurice; EDF Direction de la Distribution; Paris la Défense, France
Developments in medium voltage polymeric cables
ROSS Alec; Eastern Electric Board; Ipswich, UK.
Progress with XLPE insulated medium voltage cables in the Federal Republic of Germany
SCHUPPE Wolf Dieter; AEG KABEL; Monchengladbach, Germany
MV and HV crosslinked material insulated cables manufactured in different European countries. Typology - Use - Prospects
BECKER J.; Câblerie de Charleroi-CDC; Charleroi, Belgique
GASPARINI Georgio; CEAT CAVI; Torino, Italy
MONTEYS J.; ROQUE; Barcelona, Spain
ROY Daniel; CFG; Sens, France
A new one step crosslinking process for MV cables
HOCHSTRASSER U.P.; MAILLEFER; Ecublens Lausanne, Switzerland
Polyethylene insulated medium voltage cables with solid aluminium conductors. aluminium screens and aluminium neutrals
KARDOS George; Hungarian Cable Works; Budapest, Hungria
Some aspects of compatibility and short circuit characteristics of medium voltage polymeric cables
RATRA M.C.; Central Research Institute Bagalore-India; Bangalore, India
Performance of EPR insulated cables under different laying conditions and unusual thermal stresses
FARNETI F.; ENEL Centro di Ricerca Elettrica; Cologno Monzese, Italy
METRA P., PORTI NARI G.; CAVI PIRELLI; Milano, Italy
BERTANI E., MOSCA Walter; CESI; Milano, Italy
Thermomechanical behaviour and watertightness of MV polymer insulated cables
BOURJOT Pierre; CEAT; Poissy, France
GAUTHIER Pierre; TREFICABLE PIRELLI; Amfreville-la-mi-voie, France
PINET Alain; EDF-DER; Moret sur Loing, France
1984 - A4-1
Failure rate estimating tests of PE insulated power cables for voltages up to 12/20 kV
GARBARSKI Marek; ENERGOKABEL; Varsovie, Poland
GROBICKI Jan; ENERGOKABEL; Varsovie, Poland
1984 - A4-2
Reliability control of cables by tests in situ
MOHR P.F, SMAJLER Adolf J.; CABLERIE DATWYLER; Altdorf/UR, Switzerland
AC test methods used for 11 kV extruded cable in CEGB power stations
WILSON A., SWINGLER S.G; CEGB-CERL; Leatherhead, Surrey, UK
HALL L.; CEGB-SE Region; Dartford, Kent, UK
Quality evaluation of accessories for MV polymeric cables
DUCHATEAU Francis., PINET Alain; EDF-DER; Moret sur Loing, France
The influence of testing conditions on the electrical behaviour of contaminated insulation compound
MATEY Gabriel; BP CHEMICALS Chemicals and Plastics Laboratory; Meyrin, Switzerland
Water treeing and electrical treeing
FILIPPINI J.C., KOO J.Y., POGGI Y.; CNRS Laboratoire d'Electrostatique et de Matériaux Diélectriques; Grenoble, France.
LAURENT Christian, MAYOUX Christian, NOEL S.; Université Paul Sabatier Laboratoire de Génie Electrique; Toulouse, France
Measurement of water tree penetration by neutron activation analysis
CRICHTON B.H., GIVEN M.J., FARISH O.; University of Strathclyde Dept.of Electronic and Electrical Engg; Glasgow G1 1XW, UK
BANFORD H.M.; SCOTTISH UNIVERSITIES Research and Reactor Center; GLASGOW G1 1XW, UK
1984 - A5-4
Ageing of polyethylene power cables saturated with water
RYNKOWSKI Adam W, BORYN Henryk, WOJTAS Stanislaw; Technical University of Gdansk; Poland
Factors affecting the dielectric strength of extruded dielectric cables in wet environment
SILVER David A, LUKAC R.G.; PIRELLI CABLE; Union, NJ 07083, USA
Life estimation and improvement of water-tree resistivity of XLPE cables
NAGASAKI S., MATSUBARA H., YAMANOUCHI S., MATSUIKE T., FUKUNAGA S., KEISHI T.; Sumitomo Electric Industries; Osaka, Japan
Testing possibilities and results regarding water aging of PE/XLPE insulated medium voltage cables
FRANKE Hermann, HEUMANN Heinz, KAUBISCH Dieter; AEG KABEL; Monchengladbach, Germany
Water tree deterioration and counter measure of low and medium voltage XLPE cables
TANABE Teruyoshi, SAKURAI T., KIKUCHI K., FUKUDA T.; FURUKAWA ELECTRIC; Ichihora, Chiba, Japan
Influence of water on dielectric strength and rejuvenation of in-service aged URD cables
KATZ C., EAGER Jr G.S.; CABLE TECHNOLOGY LABS; New Brunswick, NJ, USA
LEBER Eric R.; AMERICAN PUBLIC POWER; Washington DC, USA
FISCHER Frank E.; ORANGE &ROCKLAND UTILITIES; Pearl River, NJ, USA
Advances in crosslinking polyethylene insulation for medium and high voltage cables
FISHER E-J.; UNION CARBIDE Wire & Cable Materials Export; Danbury, CT 06817, USA
Cable fire testing to meet realistic design criteria
BERRY D.L., KLAMERUS L.J.; SANDIA NATIONAL LABORATORIES; Albuquerque, NM 87185, USA
Cables having improved fire performance
PHILBRICK S.E., McCONNELL J.; PIRELLI GENERAL; Eastleigh, United Kingdom
New cables designed to limiting the risk of proceeding from a fire
KIRCHNER François; CEAT; Poissy, France
GUERZIO M.; CEAT CAVI; Torino, Italy
VILLAGRASA F.; GENERAL CABLE CEAT; Barcelona, Spain
Improvement of the behaviour of cables in fire. Application to nuclear power stations
BERETTA G.; CAVI PIRELLI; Milano, Italy
SIMON Claude; TREFICABLE PIRELLI; Saint Maurice, France.
Electric cables and their fire behaviour : evolution of design and future prospects
COTTART J.J., LECOQ Yves, VILLEMAGNE M.; THOMSON JEUMONT CABLES; Bohain, France
Cables with reduced smoke, toxicity and fire propagation
SABISTON A.D.; AEI CABLES; Gravesend, Kent, UK.
Irradiation cross-Linking applied to non halogenated cable manufacturing
BERTIER D., BRUNEAU C., JOLY B.; ACOME; Paris, France
Halogen-free crosslinkable materials. Application to electric cables and fire behaviour
DEMAY J.N. ,MALFROY J.; LES CABLES DE LYON; Lyon, France
Fireproof thermoplastic halogen-free material for insulated cables
ROSSIGNOL G., FAVRIE C.; SILEC; Montereau, France
Halogenated elastomers versatile cable jacket materials (the role of different classes of elastomers in the fire situation)
SWEET G.C.; DU PONT UK; Hemel Hempstead, UK
Reduced fire propagation and low smoke emission requirements for power station cables
BARBER M.D., PARTRIDGE P.F.; CEGB; GLOUCESTER, UK
GIBBONS J.A.M.; CEGB; Leatherhead, Surrey, UK
Cables with improved fire behaviour : recent tests results, applications in prospect
PAYS Michel, PARIS Michel,; EDF-DER; Moret sur Loing, France
Development of haloqen-free cables in the Paris métro
CHATIRICHVILI G.; RATP Service du Contrôle et du Laboratoire; Paris, France
Moisture barrier power cable with a plastic-metal laminate sheath
BOW Kenneth E.; DOW CHEMICAL; Granville, OH, USA
Performance of ethylene-propylene rubber insulation in medium and high voltage power cables
BROWN Morton; DU PONT DE NEMOURS; Wilmington, DE, USA
Cable belt new structure including semi conducting material and allowing simultaneously continuous earthing of the screens and protection against moisture and corrosion
BERTIER D., LEMOLTON J.; ACOME; Mortain, France
CLAUDE B.; TOTAL-CFR; Harfleur, France
1984 - B1-4
Crosslinking behaviour of EVA copolymers
QUAAS Gerwolf; BAYER; Leverkusen, Germany
Crosslinked polyethylene for high-voltage cables with synthetic insulation
CAILLOT C., PARIS M., PERRET J.; EDF-DER; Clamart, France
Materials testing of aged polymer insulated cables
BERNSTEIN Bruce S.; ELECTRIC POWER RESEARCH INSTITUTE; Washington DC, USA
Materials research on extruded power cables
AZAROFF Leonid V.; University of Connecticut Institute of Materials Science; STORRS, CT 06268, USA
Measurement and process control of internal stresses in LDPE power cables insulation
DE BELLET J.J., SCHIRATO P.; BP CHEMICALS Chemicals and Plastics Laboratory; Meyrin / Genève, Switzerland
Study of silane-crosslinked materials for cable insulation
de ZELICOURT Y., PRIGENT M.; LABORATOIRES DE MARCOUSSIS; Marcoussis, France
HAUDIN; CEMEF; Valbonne, France
SCHULTZ; Laboratoire de Recherches sur la Physico-Chimie des Interfaces; Mulhouse, France
Effect of temperature rise on leakage current and breakdown of XLPE cables
ABED Youssif A., EISH Taher D.; EL-MANSOURA UNIVERSITY; Egypt
Development of a new insulating material for DC XLPE cables
FUKAGAWA Hiromasa, NITTA Yoshitaka; CRIEPI-Central Research Institute of Electric; Tokyo, Japan
SEKII Yasuo; HITACHI CABLE WORKS; HITACHIJAPON
D.C. dielectric behaviour of low density polyethylene. Influence of pressure - utilization prospects
PERRET J., PAYS Michel; EDF-DER; Clamart, France
BUI AI, HOANG THE GIAM, GUERIN P.; Université Paul Sabatier Laboratoire de Génie Electrique; Toulouse, France
The potential of extruded XLPE for cryogenic power cables
RABINOWITZ Mario; ELECTRIC POWER RESEARCH INSTITUTE; Palo Alto, CA, USA
SOSNOWSKI Marek; CABLE TECHNOLOGY LABS; New Brunswick, NJ, USA
Review of Italian experience on M.V. submarine cables insulated with synthetic extruded materials
GIUSSANI Alberto, BRACCO Gianluigi; CAVI PIRELLI; Milano, Italy
Watertight medium voltage submarine cables
BAYARD Claude, GAUBERT J.B.; LES CABLES DE LYON; Bourg en Bresse, France
Testing of a high voltage XLPE cable for dynamic submarine application
SODEN J.E., TRAUT R.T.; SIMPLEX WIRE AND CABLE; USA
SAINT ONGE Hugues, TRAIN D.; Institut de Recherches d’Hydro-Québec; Varennes Québec, Canada
New high voltage terminals developed to meet high working temperatures
DEJEAN Pierre-Marcel, FRETIER P., REDOLAT Raymond; CGF; Sens, France
High-voltage accessories for XLPE insulated cables 52/170 kV. Design and experience of stress cones in EPDM rubber
HEDMAN Leif; KABELDON; Alingsas, Sweden
New type of prefabricated terminals for EHV synthetic insulated cables
AUCLAIR H., DHUICQ B.; SILEC; Montereau, France
Electrical dimensioning of cables joints with cross bonded sheaths
BERNARD G., DORISON E., PICHE F., SABOT A.; EDF-DER; Moret sur Loing, France
After laying test of HV and EHV cables
DORISON Eric, AUCOURT Christian; EDF-DER; Moret sur Loing, France
The experience in service for 66 kV XLPE insulated power cables
TAKENOUCHI K., NAKAGAWA H., NAKABASAMI T., KATSUMATA A.; TOKYO ELECTRIC POWER; Tokio, Japan
Development and installation of 154 kV XLPE cables
NAKAGAWA H., NAKABASAMI T.; TOKYO ELECTRIC POWER; Tokio, Japan
TANABE Teruyoshi; FURUKAWA ELECTRIC; Ichihora, Chiba, Japan
AIHARA M.; Showa Electric Wire & Cable; Kawasaki, Japan
KONDA A.; Sumitomo Electric Industries; Osaka, Japan
Actual installation of short distance 275 kV XLPE cables and technical development for long distance installation
WATANABE Y., NAKAGAWA H.; TOKYO ELECTRIC POWER; Tokio, Japan
SUGIYAMA K.; DAINICHI NIPPON CABLES; Tokyo, Japan
ONO M.; Fujikura Ltd; Tokyo, Japan
SEKII Yasuo; HITACHI CABLE WORKS; HITACHIJAPON
The synthetic extruded insulation cables in the power transmission network of Electricité de France
CUCHE M., ROYERE A.; EDF-CERT; Paris 08, France
LEPERS J.; EDF-CRTT; Boulogne Billancourt, France
EPR insulated cables for voltages ranging from 6/10 to 87/150 kV. Developments, tests and achievements
SCHMID M., SCHMIDT B.R., CONTALBRIGO E., LAURENT M.; CABLERIES ET TREFILERIES DE COSSONAY; Cossonay Gare, Switzerland
XLPE cable properties after long time service at E.H. voltage levels
WRETEMARK Sven, NELIN Göran; SIEVERTS KABELVERK; Sundbyberg, Sweden
Projects in the field of 225 kV EHV cables with low-density polyethylene insulation
FAVRIE Eugène; SILEC; Montereau, France
Development of 500 kV bulk power XLPE cable and accessories
TAKAOKA M., MOHTAI T., ONO M., KAJI I.; Fujikura Ltd; Tokyo, Japan
New catenary extrusion line designed for HV and EHV cables
MIDOZ Jacques; TREFICABLE PIRELLI; Saint Maurice, France.
Development of various snaking installation methods of cables in Japan
NAKAGAWA H., NAKABASAMI T.; TOKYO ELECTRIC POWER; Tokio, Japan
SUGIYAMA,K., SHIMADA A.; DAINICHI NIPPON CABLES; Tokyo, Japan
New solutions in connecting, tap-off, energizing and measuring in medium voltage work
SANDER Dieter; KARL PFISTERER; Stuttgart Germany
Terminations and joints for medium voltage XLPE insulated cables containing water
WIKMAR Kjell; KABELDON; Alingsas, Sweden
1984 - C-11
Material accessories for LV aerial bundled conductors
LIENART Jean-Pierre; MAUCO; Fontaine, France
Halogen-free fire resistive joints for low and medium voltage cables
BESSEl Herbert, JOHN Gunther; 3 M ELECTRICAL LABORATORIES; Hambourg, Germany
Accessories for halogen-free fire-retardant and fire-resistant cables
BEYERSDORFFER Kurt W., TAMPLIN P.; RAYCHEM; Putzbrunn / Munchen, RFA
Evolution of pulling and laying equipment
GATTEGNO Michel; GATTEGNO; Noisy le Sec, France
Termination and high voltage direct current cable suitable for the current supply of electrostatic fibers
DEJEAN Pierre-Marcel; CGF; Sens, France
BORRAS FIGUERAS Tomas; SAENGER; Barcelona, Spain
Application of mica-tapes in fire resistant cables
GAUER Peter; SWISS INSULATING WORKS; Breitenbach, Switzerland
Conductive and non conductive waterswellable nonwovens for longitudinal waterblocking
NIEUWHOF B.J.; FIRET; Veenendaal, The Netherlands
Insulation process of synthetic materials with a multiscrew two stages extruder
ARElAS Guy; EMS EXTRUSION; St Witz, France
1984 - C-19
The possible intervention of the field enhanced ion absorption effect in the phenomenon of water treeing
TOBAZEON R.; CNRS / Laboratoire d'Electrostatique et de Matériaux diélectriques; Grenoble, France.
Heat-shrink cable accessories for plastic cables up to 36 kV
HAVERKAMP Wolfgang, LE BAUT Pierre-Yves; RAYCHEM; Saint Ouen l'Aumone, France
Location of partial discharges in drum length cables
SMITH A.P.; AEI CABLES; Gravesend, Kent, UK.
Measuring and Locating of partial discharges in power cables
SZALOKY G.; HAEFELY; Basel, Switzerland
SCHWARZ M.; KABELWERKE BRUGG; Brugg, Switzerland
Carboxymethylcellulose and water tightness of cables
MOMBELLET Henri; HERCULES; Alizay, France
New connecting equipment for MV synthetic insulated cables
CHAZELAS E., ARETTE-HOURQUET D.; SILEC; Montereau, France
Preinsulated connection equipment for LV insulated bundled overhead lines
JACQUENET J., JOANNY G.; SIMEL; Gevrey Chambertin, France
Premoulded cable connector system for today and tomorrow
CHATTERJEE Shotu; AMERACE; Erembodegem, Belgique
Elastic moulded components for terminations of synthetic insulation power cables
BATAILLE C., DRUMONT C.; TREFICABLE PIRELLI; Saint Maurice, France.
Development of factory molded splices to meet the requirements of advanced synthetic insulated medium voltage cable designs
VARNER Wayne F.; 3 M; Saint Paul, MN, USA
Development of methods to estimate the residual life of XLPE cables deteriorated by water trees
FUKAGAWA Hiromasa, OKAMOTO T., HOZUMI N., SHIBATA T.; CRIEPI, Yokosuka Research Lab; Yokosuka, Japan
Diagnostic method for high voltage XLPE insulated cable in the field
HIRATAT., FUJIGAKI S.; Chubu Electric Power Co.; Nagoya, Japan
SUGIYAMA K., INAMI.M; Mitsubishi Cable Industries; Tokyo, Japan
TAKEHANA H.; Fujikura Ltd; Tokyo, Japan
Investigation on deterioration of 22 to 66 kV XLPE cables removed from actual service lines
MATSUURA K.; OSAKA UNIVERSITY; Japan
OHNO H., ISHIBASHI A; TOKYO ELECTRIC POWER; Tokio, Japan
YATSUKA K., HIROTSU K.; SUMITOMO ELECTRICINDUSTRIES; Osaka, Japan
KAJIKI 1., SHINAGAWA J.; Showa Electric Wire & Cable; Kawasaki, Japan
Present condition of XLPE cables used in Japan and cable fault analysis
JINNO M., KOBASHI K; Kansai Electric Power Co; Osaka, Japan
TANABE Teruyoshi, ASADA Y.; FURUKAWA ELECTRIC; Tokyo, Japan
Evaluation of long-term electric strength of polymer insulated HV and VHV cables
MESHCHANOV G.I., SHUVALOV M.Y.,GLEIZER S.E., MAKAROV L.E.; ALL UNION CABLE RESEARCH INSTITUTE; Moscow, USSR
Dielectric performances of the 20 kV XLPE cable used in France
PINET Alain, PAYS Michel; EDF-DER/ERMEL; Moret-sur-Loing, France
Comparative performances of EPDM versus XLPE as insulation for distribution cables
CHAN John C., HIIVALA Lauri J.; CANADA WIRE & CABLE; Toronto, Canada
Elevated temperature operation of XLPE distribution cable systems
ORTON Harry E., FLETCHER R.G., CARTLIDGE D.M., BRADLEY J.F., COLWELL M.J., WONG J.Y.; BC HYDRO RESEARCH AND DEVELOPMENT; Surrey, Canada
Comparison of thermal cycling effects on 11 kV XLPE insulated cables with solid and stranded aluminium conductors
HOWARD Roy S., ROSS Alex; EASTERN ELECTRIC BOARD; Ipswich, UK.
The use of self-adhesion tapes for MV and HV accessories
METZGER Gisèle, DUCHATEAU F.; EDF-DER/ERMEL; Clamart, France
Research on heat shrinkable accessories
WANG WEI; MINISTRY OF WATER RESOURCES AND ELECTRIC POWER; Wuhan, PR of China
High voltage transition joints between plastic and paper insulated cables of up to 41.5 kV rating using heat shrinkable components
HAVERKAMP Wolfgang L., HEY S.A., WILCK M.H.; RAYCHEM; München, Germany
A new generation of modular elastic MV cable termination
TARDIF Laurent; TREFICABLE PIRELLI; Saint Maurice, France.
VALLAURI U.; CAVI PIRELLI; Milano, Italy
FRANKS R.; PIRELLI GENERAL; Eastleigh, United Kingdom
Improved fire behavior security cables service voltage 1000 V
BOURJOT Pierre; FILERGIE; Poissy, France
Development of cables with improved fire performance characteristics
JOURNEAUX Terence L.; PIRELLI GENERAL; Southampton, UK.
BERETTA G.; CAVI PIRELLI; Milano, Italy
GAUTIER Pierre; TREFICABLE PIRELLI; Saint Maurice, France.
New halogen-free cables with reduced toxic gases
HASEGAWA Masatake, SUNAZUKA H., SEKIGUCHI Y.,KIMURA C., YOSHINO A.; Fujikura Ltd; Tokyo, Japan.
Fire performance of insulating and jacketing materials
O'NEILL Thomas J.; DU PONT UK; Hemel Hempstead, UK
RYAN J.D.; DU PONT DE NEMOURS & CO.; Wilmington, DE, USA
Fire resistance of cable installations
KULBOTTEN Harald, NYBERG Bjorn R.; EFI Norwegian Research Institute of Electricity Suppl; Trondheim, Norway
Water, temperature and space charge influence on the breakdown of XLPE cables under divergent fields
TAHER D. EISH, FAHTI M.H. YOLlSSE; MANSOURA UNIVERSITY Electrical Eng. Dpte; Egypt.
Accelerated ageing to predict watertree behaviour in extruded cables
STEENNIS Evert Frederik, VAN DE HEUVEL C.C., BOONE Wim; KEMA LABORATORIES; Arnhem, The Netherlands
Influence of water on XLPE insulated MV cables
GEERTS G., ROBERT Alain; Laborelec; Linkebeek, Belgium
Water treeing in XLPE insulated cables at 5U
MATEY Gabriel, NICOULAZ Francis; BP CHEMICALS; Meyrin, Switzerland
Long term ageing of water immersed XLPE Insulations
MARSH Timothy G., SMITH A.P., DRYSDALE J.; AEI CABLES; Gravesend, Kent, UK.
Characterization of extruded insulation cables with respect to effects of water
FARNETI F.; ENEL; Milano, Italy
METRA P.; CAVI PIRELLI; Milano, Italy
ORTIZ M.R.; PIRELLI BRASILEIRA; Sao Paulo, Brazil
Growth of water trees and their influence upon the breakdown strength of EPR materials
FAREMO HaJlvard; EFI; Trondheim, Norway
Ionic impurities in extruded cable insulation : analytical detection techniques, sources, nature and effects
MASHIKIAN Matthew S., GROEGER Joseph H.; University of Connecticut Electrical Insulation Research Center; Storrs, USA
Elemental and ionic impurities in cable insulation and shields
CRINE Jean Pierre, PELISSOU Serge, ST-ONGE Hugues; IREQ; Varennes Québec, Canada
ST-PIERRE J., KENNEDY G.; Ecole Polytechnique de Montréal; Québec, Canada
HOUDAYER A., HINRICHSEN P.,; UNIVERSITE DE MONTREAL; Québec, Canada
The role of N2 impregnation and ultraviolet, stabilizers in polymeric insulated high voltage cables
BAMJI Soli S., BULINSKI A.T., IDENSLEY R.J; NATIONAL RESEARCH COUNCIL; Ottawa, Canada
Influence of the manufacturing process of LDPE on its behaviour under electric stress
CHAPEAU F., ALQUIE C., LEWINiER J.; ESPC; Paris, France
AUCLAIR H., JOCTEUR R.; SILEC; Montereau, France
High voltage cable threshold fields and reliability
SIMON Claude; TREFICABLE PIRELLI; Saint Maurice, France.
A study on the development of a free strippable thermosetting outer semiconductive compound for power cable
BAE HUN-JAI, HAN KEE-MAN, CHOI JONG-CHEOL, PARK SEONG-KEUN; GOLD STAR CABLE; Seoul, Korea
The development of a water tree retardant XLPE insulatio
KIMURA Hitoshi, MUTO Hideji, IRIE Shinichi; FURUKAWAELECTRIC; Chiba, Japan.
Development of a new insulating material for power cables
KOJIMA Shinji, y AZAKI F.; NIPPON PETROCHEMICALS; Kawasaki, Japan
IKEDA M., OHKI Y.; WASEDA UNIVERSITY; Tokyo, Japan
HOZUMI N.; CENTRAL RESEARCH INSTITUTE OF ELECTRIC POWER INDUSTRY; Tokyo, Japan
EPR high voltage cables
ORTIZ M.R.; PIRELLI BRASILlEIRA; Sao Paulo, Brazil
LANFRANCONI G.M., VECELLIO B.; CAVI PIRELLI; Milano, Italy
New development for HV cables
AUCOURT C., DORISON E.; EDF-DER/ERMEL; Moret-sur-Loing, France
HV cables with corrugated laminate aluminium sheath : construction, characteristics, laying advantages
FONDEUR Jean Hubert, DEJEAN Pierre M.; FILERGIE; Paron Sens, France
Development of a rapid-fitting pre-moulded joint for extruded insulation cables up to 275 kV
PARMIGIANI Bruno, VALLAURI U.; CAVI PIRELLI; Milano, Italy
Dévelopment in France of the 400 kV LOPE insulated cable
AUCLAIR Henri, DHUICQ, FAVRIE Eugène; SILEC; Montereau, France
Evaluation of ageing in transmission and distribution extruded dielectric cables
CRINE Jean Pierre, ST-ONGE Hugues; IREQ; Varennes Québec, Canada
Investigations of polyethylene insulation resistivity of power cables
WOJTAS Stanislaw; POLITECHNIKA GDANSKA; Gdanska, Poland
Estimation of Life expectancy of polyethylene insulated cables
SRINIVAS N. Nagu; Detroit Edison Company; Detroit, USA
BERNSTEIN B.S.; EPRI; Washington DC, USA
Long term ageing phenomena of XLPE cable
KITAI S., ASAI S., HIROTSU Kenichi; SUMITOMOELECTRIC INDUSTRIES; Osaka, Japan
Characterization of the degree of cable ageing by a dual polarity breakdown test method
DIMA A., KATZ Carlos, EAGER Jr. G.S.; CABLE TECHNOLOGY LABS.; New Brunswick, NJ, USA
EATON R.; US DEPARTMENT OF ENERGY; Washington DC, USA
The measurement of internal fields in insulators for high voltage cables - Possibilities opened by the pressure wave propagation method
ALQUIE C., LEWINER J.; ESPCI; Paris, France
Comparative study of the behaviour of two polyethylene types under DC voltage, by the pressure wave method
CHAPEAU F.,DlTCHI T., ALQUIE C., LEWINER J.; ESPCI Laboratoire d'Electricité Générale; Paris, France
PERRET J., DALLE Bernard; EDF-DER/ERMEL; Clamart, France
About a method to measure space charge density inside PE
TOUREILLE Alain; USTL; Laboratoire d'Electricité, MontpeIlier, France.
Influence of conduction on the breakdown mechanism of polyethylene under hydrostatic pressure
HOANG-THE-GIAM, BUI AI, ANTONIU A.; Université Paul Sabatier; LGET, Toulouse, France
GUERIN P. ; LCIE; Fontenay aux Roses, France
PERRET J.; EDF-DER/ERMEL; Clamart, France
Water treeing under DC voltage with polyethylenes for HV DC cables
FILIPPINI J.C., JANTZEN A.; CNRS Laboratoire d'Electrostatique et de Matériaux Diélectriques,; Grenoble, France.
DALLE B., DESCHAMPS L., PERRET J.; EDF-DER/ERMEL; Clamart, France
Extruded synthetic insulations for development of HDVC energy cables
PAYS Michel, LOUIS Michel; EDF-DER/ERMEL; Moret-sur-Loing, France
1987 - B2-3
TOPIST, an innovative HVDC submarine cable
BALOG G.; STK; Okern, Norway
HERBRETEAU A.; TOTAL; Paris la Défense, France
LUONI Giuseppe; CAVI PIRELLI; Milano, Italy
TERRAMORSI G.; TREFICABLE PIRELLI; Saint Maurice, France.
Influence of DC voltage application on dielectric performances of XLPE cables
HARASAWA K., SHIMAMURA Y.; TOKYO ELECTRICPOWER; Tokio, Japan
FUKAGAWA H.; CRIEPI; Yokosuka, Japan
SOMA Ken-Ichiro, MARUMO M.; Hitachi Cable Ltd; Ibaraki, Japan
Cable covering failure detection
BALAN Gheorghe, MÂTHÉ Balazs; ICEMENERG; Bucharest, Rumania
Development of digital cable fault locating instrument
SUZUKI Y., OHI S., ARAKANE M; Chubu Electric Power Co.; Nagoya, Japan
AIHARA M., FUJIWARA Y., SHINAGAWA Junichi; Showa Electric Wire & Cable; Kawasaki, Japan
Scope of echometry for faults location on energy cables
PAYS Michel; EDF-DER/ERMEL; Moret-sur-Loing, France
Thermal control of underground cables - hot spot detection
THEVENON Henri; LES CABLES DE LYON; Calais France.
Power cables electromagnetic and thermal modelling
KLADAS A., PICHON L., RAZEK A.; ECOLE SUPERIEURE D'ELECTRICITE; LGEP, Gif Sur Yvette, France.
Electromagnetic forces and installationmethods for single core cables
KLEVJER Gunnar, LERVIK Jens Kristian; EFI Norwegian Research Institute of Electricity Suppl; Trondheim, Norway
A study on insulation shrinkback in cross-linked polyethylene cables
ASADA Yoshihisa, MARUYAMA Y.; FURUKAWAELECTRIC; Chiba, Japan
The nature and distribution of water in steamcured XLPE cables
PELISSOU Serge, CRINE Jean Pierre, CASTONGUAY Jacques, HARIDOSS S.; IREQ; Varennes Québec, Canada
BOSE Tapan K., MERABET Mustapha; UNIVERSITE DU QUEBEC-Dpt. de Physique; Trois Rivières, Canada
TOBAZEON R.; CNRS/LEMD; Grenoble, France
Experimental difficulties and significance of water-content measurements in cable insulations
GROEGER Joseph H., DAMON Dwighf H.; University of Connecticut Institute of Materials & Science; Storrs, USA
PELISSOU Serge, CRINE Jean Pierre, ST-ONGE Hugues; IREQ; Varennes Québec, Canada
Microscopic failure in water-treeing and fatigue as revealed by transmission electron microscopy
ROSE L.J., ROSE V. ; BP CHEMICALS; Research & Development, Grangemouth, UK.
DE BELLET J.J.; BP CHEMICALS; Meyrin Switzerland
Differential thermal analysis of electric ageing of polyethylene samples in water
GLUCHOWSKI S.; INSTYTUT PODSTAW ELEKTROTECHNIKI I ELEKTROTECHNOLOGII; Wroclaw, Poland
LAURENT C., MAYOUX C.; UNIVERSITE PAUL SABATIER; LGET, Toulouse, France
Optimization of cable crosslinking process on dry curing Lines
SCHIRATO Philippe; BP CHEMICALS SUISSE; Meyrin, Switzerland
FRETIER P.; FILERGIE; Paron Sens, France
Design consideration and thermal stability calculation of shields used in high voltage XLPE insulated power cables
OBRAZTOV Yu.V., SINYAKIN A.F., KHOLOONY S.O.; ALL UNION CABLE RESEARCH INSTITUTE; Moscow, Russia
Water treeing retardant XLPE insulation grade with improved electrical endurance
FARKAS Andras A., SULTAN B-A, AHLSTRANO L-E; NESTE POLYETEN; Stenungsund, Sweden
Development in semiconductive products for medium voltage XLPE power cable
BURNS Norman M. Jr,; Union Carbide Corporation; Somerset, NJ, USA
Fire resistant halogen free materials for electric cables industry - Technical and economical situation
DUPONT, MONJARDET, SAUNIER; FILERGIE; Paron Sens, France
GUERZIO, PELATI, BONINO; CEAT CAVI; Torino, Italy
Investigation on EVA grades for fire resistant halogen free thermoplastic cables
DRUOT Ph.; ATOCHEM; Orthez, France
Water impervious on-jacket moisture barrier cable
GROSSER Brian K., BOW K.E.; DOW CHEMICAL; Granville, OH, USA
SMITH J.; DOW CHEMICAL EUROPE; Horgen, Suisse
NIEUWHOF B.J.; FIRET; Veenendaal, The Netherlands
Taking into account of the overloading capacity of cables in the dimensioning of HV and VHV links
DHAUSSY M.; EDF-DPT/CERT; Paris la Défense, France
DORISON Eric; EDF-DER/ERMEL; Moret-sur-Loing, France
LEPERS J.; EDF-DPT/CRTT; Vitry, France
Fault current rating of metallic cable screens
WHITE LM.; ELECTRICITY COUNCIL; London, UK.
PHILBRICK S.E.; PIRELLI GENERAL; Eastleigh, United Kingdom
HYDE H.B.; EAST MIDLANDS ELECTRICITY BOARD; Nottingham, UK
PRYER D.W.; BICC POWER CABLES; Wrexham, UK
Thrusts and short circuit phenomena in extruded HV cable systems and methods to control the
LEUFKENS P.P., WILLEMS H.J.M.; VAN DER MAAREL P.C.M.; NKF KABEL, Delft, The Netherlands
Recommendations for cables installation taking into account mechanical stress during laying process
GASPARINI Georgio; CEAT CAVI; Torino, Italy
ROY Daniel; FILERGIE; Paron Sens, France
Experiences of mechanized laying for underground cables in rural area
KERN Bernard, HIRTH Bernard; ELECTRICITE DE STRASBOURG; France
275 kV XLPE insulated cables for tunnel and shaft installations
BENNETT Harold Roy; PIRELLI GENERAL; Eastleigh, United Kingdom
GIBBONS J.A.M.; CENTRAL ELECTRICITY RESEARCH LA8S; Leatherhead, Surrey, UK
Thermo-mechanical behaviour of 275 kV XLPE cable in tunnel
WATANABE Y., YAGISAWA K.; TOKYO ELECTRIC POWER; Tokio, Japan
HIYAMA S., NISHINOMA Masachiro; Fujikura Ltd; Tokyo, Japan
Installing 225 kV synthetic insulation cables in very deep shafts
AUCLAIR Henri, BARSACQ M., FAVRIE Eugène; SILEC; Montereau, France
BHEEMAN L.; TAMIL NADU ELECTRICITY BOARD; India.
Materials development for special cables
MURPHY Richard John; PIRELLI GENERAL; Eastleigh, United Kingdom
BERETTA G.; CAVI PIRELLI; Milano, Italy
Cables with aluminium alloy conductor for aeronautic use
BASLY Michel, FERLIER Jean Pierre; FILOTEX; Draveil, France
Extension of the field of the heating electrical cables
DELEAGE Pierre ; DELEAGE; Saint Malo, France
COUPPE Gérard; TREFICABLE PIRELLI; Saint Maurice, France.
Cables for mines : supply of bottom installations by HV cables
BLIGNY Jean, WIEDENKELLER J.G.; SILEC; Montereau, France
Optical fibers in power underground links
DUCHATEAU Francis; EDF-DER/ERMEL; Moret-sur-Loing, France
Submarine power cable incorporating telecommunications data and control links
MARSH Timothy G., BEER L.,J. SHACKLETON D.J.; AEI CABLES; Gravesend, Kent, UK.
Composite power and optical submarine cable
CANTEGRIT B., BAYARD C., TREZEGUET J.P.; LES CABLES DE LYON; Clichy, France.
Submarine composite cables for power and data transmission - Design philosophy
GIUSSANI A., LANFRANCONI G.M., OCCHINI Elio; CAVI PIRELLI; Milano, Italy
ion migration in aged power cable
RICHARDSON Colin G., MATEY G.; BP CHEMICALS; Meyrin, Switzerland
ROSE L.J.,; BP CHEMICALS; Grangemouth, U.K.
FINNEY RW.,; BP Research Centre; Sunbury -U.K.
Discharges in polymers
DANIKAS M.G.; ASEA Brown Boveri; Baden Switzerland.
Study of the kinetic of the degradation of LOCA cable materials. Influence of the radiation dose and of the dose rate
GUEGUEN V., AUDOUIN L.; ENSAM; Paris, France.
PINEL B.; EDF/DER; Clamart, France
SEYTRE G., PHELUT L; CNRS; Lyon, France
Procedure for the ageing studies concerning the polymeric cables
DUCHATEAU Francis & Co-authors; EDF/DER; Clamart, France
Membrane potential technique applied to the study of cable insulation modification
MONDIN Sylvie, AREFI F, AMOUROUX J.; ENSCP; Paris, France
LETELLIER P.; Université Paris 6; France
GOLDMAN M.; ESE; Gif-sur-Yvette, France
FEDOROFF M.,ROUCHAUD J.C.; CECM/CNRS; Vitry, France
LEGUENNEC P.; EDF/DER; Clamart, France
Long-term performance of silicone lubricants used for separable interface electrical connector
GROEGER Joseph H.; University of Connecticut; Storrs, USA
Wet electrical ageing characteristics of various furnace carbon blacks
LEFEBVRE Steven D. , SIFLEET William L.; CABOT Corporation; Corporation Billerica, USA
GROEGER Joseph H.; University of Connecticut; Storrs, USA
TOMME Marcel; CABOT Technical Center; Leiden, The Netherlands
Use of after laying test methods for the evaluation of the ageing of MV cables
BAUTZ R., KRÂHENBÜHL Francis, VELUZATG., WAVRE J. J; Cables Cortaillod; Cortaillod, Switzerland
Characterization of medium voltage cable splices aged in service
LAMARRE Laurent, CHINH DANG; Hydro-Québec; Varennes Québec, Canada
Degradation of LOPE insulation of 15 kV power cables in laboratory and service environment
BORYN H., WASILENKO E., WOJTAS S.; Technical University of Gdansk; Poland.
Remaining properties of PVC cables for power stations. Correlation between chemical and electrical performances
METZGER Gisèle, PAYS Michel; EDF/DER; France
High performance semiconductive compounds testing, production and experience
FARKAS A. Andras, NILSSON U.H., AKERMARK G.; NESTE POLYETEN; Stenungsund, Sweden
Semiconductive plastic coated metallic shielding and armouring materials for power cables
BOW Kenneth E.; Dow Chemical; Granville, OH, USA
BIERINGA L., SMITH John W.,ZUERCHER Karl; Dow Chemical Rheinwerk; Rheinmuenster, Germany
Development of functionalized poly-olefins based thermo-plastic elastomers (TPEs) and composites as Insulating material for medium voltage cables.
Preparation, characterization and Life time prediction by thermo analytical techniques
SANGHI L.K., BHATTACHARYYA AS.,MUKHERJEE B., SEN AK.; Fort Gloster Industries; Howrah, India
An improved medium voltage insulating material for terminations and other medium voltage electrical accessories
GRAEVE B.D., HAVERKAMP W.L., PENNECK R.J., TAMPLIN Paul; Raychem; Ottobrunn, Germany
New MV polymeric insulated power cable (XLPE) design
URTUBI José-Maria, ELEJALDE F.J.; IBERDUERO; Bilbao, Spain
AZPEITIA J.; CABLENOR; Vitoria, Spain
Laboratory investigation of failure of medium voltage XLPE cable joints
RATRA M. C., NAGAMANI H.N.; Central Power Research Institute; Bangalore, India
Compact derivation for LV underground network
MOPTY Yves, DUPONT André; SIMEL; Gevrey Chambertin, France
TARDIF Laurent, REDOLAT Raymond; Cables Pirelli; Saint Maurice, France
Cable terminal and connecting systems. Inner cone system connex
SCHUSTER Martin; PFISTERER; Stuttgart Germany
Development of flat by-pass cable best-suited for on-the-ground installation
FUTAMATSU.K., KUMAZAWA Takao; Chubu Electric Power; Nagoya, Japan
GOTO Y., HIYAMA S.; Hitachi Cable Ltd; Japan
KIDO K., HAGIWARA T.; Furukawa Electric; Japan
Machine-aided cable laying in French MV systems. Latest development
KASZOWSKI Daniel; Alcatel Câble; Clichy, France.
Study of the evaluation of operating reliability of polymeric 20 kV cables
GHITA Teodor, PADENCOV Delia, SANDULaura; MIMUEE, Research Institute for the Electrotechnical Industry; Bucharest, Rumania
1991 - A3-4
A method to estimate the service reliability of XLPE insulated power cables
BENES V.; Power Research Institute; Brno, Czechoslovakia.
Operation behaviour of underground LV and MV cables in Rumanla. Phenomena analysis and specific solutions for underground or underwater MV cables
operation
PISPIRIS C.S.; ICEMENERG; Bucharest, Rumania.
Temporary cable connections for 90 and 63 kV applications using EPDM insulation
MIDOZ Jacques; Cables Pirelli; Charenton-Ie-Pont., France
High voltage cables (86 kV A.C.) insulated with thermoplastic materials
COCIU Alina-Craita; ICPE-Research Institute of Electrotechnical Industry; Bucharest, Rumania.
Thermomechanical behaviour of HV and EHV cables with copper conductors
SCHOONAKKER P.,WILLEMS H.M.J.; NKF KABEL BV; Delft, The Netherlands
Thermomechanical behaviour of XLPE cables under normal and short-circuit conditions
HEAD J.G., CROCKETT A.E.; Pirelli General; Eastleigh, United Kingdom
WILSON A., WILLIAMS D.E.; National Grid; United Kingdom
Design method and analysis for thermo-mechanical behaviour of 275 kV XLPE cables
ISHII K., IWATA Z., INOUE T.; FurukawaElectric; Ichihara- Japan
Development of heat resisting type cable joints for 66-77 kV gas insulated transformers
KASE Toshio, TAKEDA Shouji, NAKADATEMasumi.; Toshiba; Kawasaki, Japan
YOSHIKAWA Hideo, SEMA Nobuyuki.; Showa Electric Wire & Cable; Kawasaki, Japan
Development of prefabricated joints for 154 kV XLPE cable
HAYASHI M.,AKIYAMA T., INOUE T.; TheKansai Electric Power; Osaka, Japan
INOUE H., FUDAMOTO K.; Sumitomo Electric Industries; Osaka, Japan
NAKANO T., GOTOH S.; The Furukawa Electric; Tokyo, Japan
A range of transition joints for 33 kV to 132 kV polymeric cables
ATTWOOD J.R, GREGORY Brian, SVOMA R; BICC CABLES; Erith, United Kingdom
Development of pre-fabricated joints for 275 kV XLPE cables
IMAI N.,ANDOH K.; Mitsubishi Cable Industries; Saitama, Japan
Installation of cables of 130/225 kV specified voltage in case of sub-fluvial crossing
SIN Sylvie; EDF/CERT; Paris, France
FAVRIE Eugène, BARSACQ M.; SILEC; Montereau, France
SAINT-MARTIN; HDI; Cergy-Pontoise, France
LATARGES; SPIE TRINDEL; Cergy-Pontoise, France
Installation of a 230 kV XLPE insulated cable at Ontario Hydr
FOTY S.M., GUPTA B.K., HORROCKS D.J., KUFFEL J.; Ontario Hydra; Toronto, Canada
Longitudinally water resistant cables
MARCIANO-AGOSTINELLI F., CINOUEMANIP.L.; Pirelli-Cable; Lexington, USA
KUCHTA Frank L.; Pirelli Cable; Greenwood, USA.
Resistance to sea water and evaluation of the aggression of the biological sea environment of the insulation and the sheath of energy cable used for
supplying off-shore platforms
NEDEA Mihail Adrian; ICPE- Research Institute for Electrotechnical Industry; Bucharest, Rumania
Longer Life cables by use of tree retardant XLPE Insulation and super-smooth shields
EICHHORN R.M.; Union Carbide Chemicals and Plastics; Somerset, NJ, USA
SCHÀDLlCH H.; Kabelmetal Electro Hannover; Germany
BOONE W.; Kema Laboratories; Arnhem, The Netherlands
Influence of water on synthetically Insulated MV cables and accessories
ROSEVEAR Robert D.; Pirelli General; Eastleigh, United Kingdom
WTR XLPE Insulation. Laboratory and field experience
MATEY Gabriel; BP CHEMICALS; Meyrin Switzerland.
SCHUPPE W.D., BANOWSKI 0.; AEGKABEL; Monchengladbach, Germany
The use of waterswellable materials in the design of power cables
DEBOER R.S., VOGEL P., LANTOR.; Firet Cable Wrappings; Veenendaal, The Netherlands
Water tree meter, an automatic equipment for water treeing measurements in insulation materials for cables
MARTEAU C., FILIPPINI Jean.; CNRS/LEMD; Grenoble, France
Test methods for assessing watertree resistant insulation
NAYBOUR R.D.; Electricity R & D Centre; Capenhurst, United Kingdom
Improved method for evaluation of water treeing properties of semiconductive materials
FARKAS A. Andras, NILSSON U.H.; Neste Polyeten; Stenungsund, Sweden
Model cable test for evaluating the ageing behaviour under water influence of compounds for medium voltage cables
LAND H.G., SCHÀDLlCH Hans.; Kabelmetal Electro; Hannover, Germany
International standardization activities for moisture impervious cables
BOW Kenneth E.; Dow Chemicals; Granville, OH, USA
SNOW Joseph H.; Anixter Bros; Angleton USA
WILKENS, William D.; Anixter Bros; Skokie, IL, USA
The effect of silver ions on the formation of water tree
FAN ZONG HUAI.; Shanghai Electric Cable Research Institute; P.R. China
LIU ZI YU; Xian Jiaotong University; P.R. China.
The influence on water treeing of ion-ion interactions in solution
CRICHTON B.H., HUIMIN LI., FOURACRE RA; CEPE University of Strathclyde; Glasgow , United Kingdom
Ageing phenomena at cable-shield interfaces affecting the propensity of the insulation to develop water trees
MASHIKIAN Matthew S., GROEGER Joseph H.; University of Connecticut; Storrs, USA
Evidence of continuous paths in the structure of water trees
MOREAU E., BOUDET A.; CEMES-LOE/CNRS; Toulouse, France
MAYOUX C., LAURENT C.; Laboratoire de GénieElectrique/CNRS; Toulouse, France
MONTAGNE PH.; ATO-CHEM; Orthez, France
BERDALA Jacques; Câbles Pirelli; Charenton-le-Pont, France
Medium voltage polymeric power cables. Clarification of the cause of water treeing and methods of its prevention
DEJEAN Pierre-Marcel; Câbles Pirelli; Sens, France
BANKS V.AA, GROOMBRIDGE AB.; BICC Cables; Clwyd- United Kingdom
AM. BOTELHO DOREGO; CQFM INIC IST; Lisboa, Portugal
PEDROSO Francisco, J. CELCAT; Pero Pinheiro; Portugal
MARCHESIE JW., GIVEN M.J., FOURACRE RA; University of Strathclyde; Glasgow G1 1XW, UK
LACABANNE C., MAYOUX Christian; Université Paul Sabatier; Toulouse, France
Average molecular weight between crosslinks and water tree growth in crosslinked polyethylene
SHAIKEVITCH A, HARIDOSS S.; AT Plastics; Brampton, Canada
ZHOUO.x., RUDIN A; University of Waterloo; Canada
A study on long-term characteristics of XLPE cables
KATSUTA Ginzo; TEPCO; Tokyo, Japan
The influence of crosslinking on the void formation in XLPE Insulation
SIMUNKOVA O., KOVACOVA 1.; Cables & Insulating Materials Research Institute; Bratislava, Czechoslovakia
A study on size effect in breakdown properties of HV XLPE cables
TANAKA Hideo, ICHIYANAGI N., MARUYAMA Y., TANABE T., IWATA Z.; The Furukawa Electric; Chiba, Japan
Influence of structural changes of XLPE on dielectric properties of cable insulation
KROLIKOWSKI Czeslaw, RAKOWSKA Aleksandra; Technical University of Poznan; Poland
Evaluation of long-term Insulation performance of EHV XLPE cables by a high frequency acceleration test
ISHIDA M., SUZUKI H., OKAMOTOT., FUKAGAWA H.; CRIEPI; Kanagawa-Ken, Japan.
XLPE behaviour under hydrostatic pressure and DC voltage. Tests on materials and full cables
HOANG-THE-GIAM, ESSOLBI R.; Laboratoire de Génie Electrique; Toulouse, France
ROY Daniel; Câbles Pirelli; Charenton-Ie-PontFrance
BALLON F., PAYS M.; EDF/DER; Moret-sur-Loing, France
Development of 10 kV submarine cable with high mechanical strength
Mc CONNELL Jim; Pirelli General; Eastleigh, United Kingdom
Gulongyu Lay 10 kV XLPE Submarine cables
HUANG Shi Sin; Xiamen Power Supply Bureau; Xiamen, PR of China
LI HanSun; Shangai Municipal Electric Power Bureau; Shanghai, P.R. China
PAULIN D.; Alcatel Câble; Calais- France
Detecting the breakdown causes of XLPE cable byPPD method
TANAKA Takeshi; TEPCO; Tokyo, Japan
WATANABE Masaru, YATSUKA Ken; Sumitomo Electric Industries; Osaka, Japan
Advances in Instrumentation for routine partial discharge measurements on HV power cables
HILDER David; Robinson Instrument; Runcorn, United Kingdom
DUFOUR François; Robinson Instruments; Sèvres, France
The development of automatic detecting system for the defects in XLPE insulated cables
IWATA l., SUZUKI H., SHIMADA M., UESUGIK; Furukawa Electric; Chiba, Japan
Development of advanced inspection method for extrusion molded joints
ICHIHARA M. YAMAMOTO M., ISHIHARA H.; Chubu Electric Power; Nagoya, Japan
FUKUI T., WATANABE K., GESSEI., SATO H.; Sumitomo Electric Industries; Osaka, Japan
Electrical treeing tests as a method to characterize insulating materials for cables
BOZZO R., CENTURIONI L.; Universita degli Studi di Genova; Italy
BELLINI V., BRAGAGNI A.; Tratos Cavi; Pieve S. Stefano, Italy.
New technique to detect short circuit current distribution on wire shielding of MV power cables
SENS MA, COSTA Eleilson B., DOSSANTOS P.; CEPEL; Rio de Janeiro, Brasil
TEIXEIRA Mario Daniel Junior, MOCARlEL JA; FICAP; Rio de Janeiro, Brasil
Mechanical short-circuit testing for cable installations
KLEVJER G., LERVIK J.K.; Norwegian Electric Power Research Institute; Trondheim, Norway
TUNHEIM A.; Alcatel Kabel Norge; Olso, Norway.
VOLDHAUG Lars; EBNorsk Kabel; Drammen, Norway
Voltage tests on three-core power cables
WASILENKO E.,WOJTAS S., BORYN H.; Technical University of Gdansk; Poland
Development of synthetic HV cable terminations
LE PEURIAN S.; EDF/DER; Moret-sur-Loing, France
DEJEAN Pierre-Marcel; Cables Pirelli; Sens, France
ARGAUT P.; SILEC; Montereau, France
Electrical testing of aged station cables
BRAUN J.M., GUPTA BK., LLOYD BA,MARRA R.M., SEDDING H.G, STONE G.C.; Ontario Hydro; Toronto, Canada
Average impulse breakdown stress. Interpretation
THEVENON Henri; Alcatel Câble; Lyon, France
Effect of DC testing on aged XLPE insulated cables with splices
SRINIVAS N. Nagu; Detroit Edison Company; Detroit, USA
BERNSTEIN B.S; Electric Power Research Institute; Washington DC, USA
Investigation of alternative after laying tests for MV cables
KALKNER Wilfried, BACH R., PLATH R., ZHIYONG WEI; Technical University of Berlin; Germany
A 50 Hz after laying test for high voltage extruded insulation cables
VERVEEN Arie N.; EWR; Leiden, The Netherlands
PAAP G.C; University of Technology; Delft, TheNetherlands.
Diagnostic medium voltage cable test at 0.1 Hz
STEENNIS Evert Frederik,HETZELE.; KEMA; Arnhem, The Netherlands
VERHOEVEN C.W.J.; PNEM; HA'sHertogenbosch, The Netherlands
Development of low smoke and fume cables and joints for the Channel tunnel
FRIDAY A, ROBERTS D.G., NICHOLLS AW.,; BICC Cables; Wrexham, United Kingdom
Low smoke, non-corrosive fire retardant cable sheaths based on HNBR and EVM
MElSENHElMER Hermann; BAYER; Leverkusen, Germany
LV cables with fire retardant sheath crosslinked at low temperature
AUDOUX Christian; Silec; Montereau, France
Development and qualification of novel cables for LOCA environment
LEE Gun-joo, SOHN Ho-soung, BAE Hunjail, KWON Sung-dae, LEE Bek-young, LEE Chong-kook, PYUN Sun-ho; Gold StarCable; Seoul, Korea
Low voltage PVC building wire and cables with improved flame resistance and with reduced emission of smoke
GARZA, Luis S., VIRKUS Jüri, FLORES Daniel; Conductores Monterrey; México
1991 - B5-1
The fire behaviour of electric cables, testing techniques : present situation and future trends in Italy
PIGINI A., VERCELLOTTI U.; CESI; Milano, Italy
FARNETI F. et al.; ENEL; Milano, Italy
1991 - B5-2
Fire resistant cables. Performance and test method developments
JOURNEAUX Terence L.; Pirelli General; Eastleigh, United Kingdom
Protecting cables from Insect attack
FIELD A.W.; BICC Cables; Wrexham, United Kingdom
PHILBRICK S.E.; Pirelli General; Eastleigh United, Kingdom.
Modelling of power transmission cables
ARGAUT P.; SILEC; Montereau, France
DORISON Eric; EDF/DER; Moret-sur-Loing, France
KARIMI C., ACHARD J.C., BLANCHET F., GERMAIN J., THIEBAUT E.; ESE; Gif-sur-Yvette, France
A fine modelling of cables in harmonic or transient cases by inverse Laplace transform
JOHANNET P.; EDF/DER; Clamart, France
Distribution and Influence of the zero-sequence short-circuit currents in the ground
DORISON Eric; EDF/DER; Moret-sur-Loing, France
Thermal modelling of underground cables under transient conditions
PICHON Lionel, RAZEK A.; CNRS/LGEP/ESE; Gif-sur-Yvette, France
Thermal conditions of cables in soil under layer with another thermal resistivity
SLANINKA Pavel; Slovak Technical University; Bratislava, Czechoslovakla.
1991 - B7-1
Calculation of the heat rate of cables for power transmission
ARGAUT P.; Silec; Montereau, France
PROTAT F., BOUVERETA-, MATHIEUN.,NGUYEN V.; ESE; Gif-sur-Yvette, France
A user-friendly computer program for economic selection of cable sizes.
ANDERSG.J., VAINBERG Mark, HORROCKSD.J., HUGHES AR., FOTY S.M., MOTLIS J.; Ontario Hydra; Toronto, Canada
Economic optimization of the conductor cross-section of power cables according IEC 20 A (CO) 131.A simplified method.
KASZOWSKI Daniel; Alcatel Câble; Clichy France
MIREBEAU Pierre; Câbles Pirelli; Saint-Maurice France
Optimization criteria of the transmission capacity of HV and VHV cables.
DORISON Eric; EDF/DER; Moret-sur-Loing, France
LEPERS J.; EDF/CRTT; Paris, France
RIOT B.; Electricité de France-CERT.; Paris, France
A study on the continuous permissible current rating in 22.9 kV CN/CV underground distribution power cables.
KOOJ.Y., KIM J.T., KIM J.B.; Hanyang-University; Seoul, Korea
Measurement of space charge distribution in cable insulation using the pulsed electroacoustlc method.
FUKUNAGA K., MIYATA H., TAKAHASHI T., YOSHIDA S., NIWA T.; Fujikura Ltd; Tokyo, Japan
Thermal wave method for evaluating the space charge in insulants : validation and application to various materials for HV cables.
TOUREILLE Alain, ABOU DAKKA M., SABIR A., CHERIFI A; LEM, USTL; Montpellier, France
Direct measurement of space charge in synthetic cables by the pressure wave method
MAHDAVI S., ALOUIE C., LEWINER J.; ESPCI; Paris, France
Comparison between the space charge distribution and the DC breakdown voltage of synthetic insulation.
BEZILLE J., BECKER J., JANAH H.; Alcatel Câble; France
PRIGENT M., PONS J.; Alcatel Alsthom Recherche; France
Influence of the pressure on the space charge included in the cable insulations.
GARROS B., HOANG-THE-GIAM, BUIAI,; CNRS/LGET; Toulouse, France
TOUREILLE Alain; Laboratoire d'Electrotechnique, Université des Sciences et Techniques du Languedoc; Montpellier, France
ROY Daniel, BERDALA Jacques; Câbles Pirelli; Charenton-le-Pont, France
Space charge under DC voltage, incidence on the after laying test of the VHV cable links.
ALOUIE C.; ESPCI; Paris, France
ARGAUT P.; Silec; Montereau, France
1991 - B9-1
Development of new materials for HVDC polymeric insulated cables.
KHALIL M. Salah; Danish Electrical Research Institute; Lyngby, Danemark
PROCIDA I.M., LOVSTROM SORENSEN P.; NKT Power Cables; Denmark
Development of DC ± 250 kV XLPE cables and factory joints
MAEKAWA Y., YAMAGUCHI A.; Electric Power Development; Tokyo- Japan
YOSHIDA S.,WATANABE K., YAMANOUCHI H.,YOKOYAMA S.; Fujikura Ltd; Tokyo- Japan
Research and development of DC XLPE cables
MAEKAWA Y., YAMAGUCHI A.; Electric Power Development; Tokyo, Japan
IKEDA C., SEKII Yasuo, HARAM.; Hitachi Cable Ltd; Hitachi, Japan
Short time breakdown and life duration under DC voltage and pressure of HDPE
BENLIZIDIA F., FARKH M., HOANG-THE-GIAM, BUI-AI; CNRS/LGET; Toulouse, France
DALLE Bernard, DUCHATEAU F.; EDF/DER; Clamart, France
ROY Daniel, BERDALA Jacques; Câbles Pirelli; Charenton-le-Pont, France
Recent developments in 400 and 500 kV XLPE cables
ARGAUT P., FAVRIE E.,; Silec; Montereau, France
Extension of XLPE cables to 500 kV based on progress in technology
PESCHKE E., SCHROTH R., OLSHAUSEN R.; SIEMENS AG.; Berlin, Germany
Prequalification test of 400 kV XLPE cable systems
HELLING K., HENNINGSEN CG.,POLSTER K.; BEWAG; Berlin, Germany
BOSOTTI O., MOSCA W., TELLARINI; CESI; Milano, Italy
Development of an XLPE insulated cable system for 400 kV operations
ROSEVEAR Robert D., LARRIVE C.; Pirelli Cables; Eastleigh, United Kingdom
PARMIGIANI Bruno; Pirelli Cavi; Milano, Italy
DEJEAN Pierre-Marcel; Câbles Pirelli; Sens, France
550 kV cables laid in tunnel for the Guangzhou pumping station
PAULIN D., LEGUE JL., VASSEUR E., COUQUET JM.; Alcatel Câble; Clichy / Calais, France
A new generation of HV and EHV extruded cable systems
WILLEMS H., GEENE H., VERMEULEN M.; NKF Kabel; Delft, Pays Bas
Mechanized laying of HV cables
DURAND P.; EDF/DEPT-CERT; Paris la Défense, France
LE PEURIAN S.; EDF/DER-ERMEL; Moret-sur-Loing, France
Fluidized thermal backfill for increased ampacity of underground power cables
PARMAR D., RADHAKRISHNA H.S., STEINMANIS J.E.,; Geotherm Inc.,; Ontario, Canada
Experience in on-line relaxation of XLPE insulated high voltage cables
KOUTI T.; Nokia Cables; Pikkala, Finland
KARPPOJ., HUOTARI P., HONGISTOA.,; Nokia-Maillefer; Vantaa, Finland
Development and qualification of a submarine 90 kV cable system using extruded insulation for the electric supply of Guernsey island
LE PEURIAN S.; EDF/DER; Moret-sur-Loing, France
SIN Sylvie, DURAND P.; EDF/CERT; Paris, France
AUCLAIR H.; SILEC; Montereau, France
Mechanical rating of single core cables in trefoil
KLEVJER G., KULBOTTEN H., LERVIK J.K.; EFI; Trondheim, Norway
Remote monitoring and simulation of 138 kV underground power pipe type cable forced cooling system
NAMKUNG S.; Commonwealth Edison; Chicago, USA
Dry terminations : applicability to EHV
ARGAUT P., LUTON M-H.; Silec; Montereau, France
Composite EHV terminations for extruded cables
ARGAUT P., LUTON M-H.; Silec; Montereau, France
Use of elastomeric material for manufacturing of HV and EHV accessories
SCHMID M., LAURENTM., GAILLE F.; Câbleries et Tréfileries de Cossonay; Cossonay, Switzerland
Development of short term use repair joint for 275 kV XLPE insulated cable
TOYA A., KATSUTA G.; The TokyoElectric Power Co.; Tokyo, Japan
NAKANO T., ADACHI K.; The FurukawaElectric Co.; Tokyo, Japan
SHIIBA Y., NAKANISHI T.; SumitomoElectric Industries; Osaka, Japan
Application of prefabricated joints to 154 kV XLPE cables in Korean power transmission system
CHOI C.S., KIM Y.; Taihan Electric WireCo.; Korea
KOOJ.; HanYang University; Kyungki,Korea
CHOI J.-H.; Korea Electric Power Corporation (KEPCO); Korea
HWANGS.C., GO C.S.,; LG Cable and Machinery Ltd,; Korea
Development of a jointing machine for XLPE cables
MAYAMA S., MIZUTANI Y.,INOUEH., FUKUNAGA S.; Sumitomo Electric Ind.,; Osaka, Japan
Prefabricated accessories for high voltage cables design, dimensioning and field experience
ONODI T.,; DATWYLER Ltd.,; Altdorf, Switzerland
Outdoor and incorporated terminations for extruded synthetic cables up to 400 kV
GAHUNGU François; Alcatel Cable; Calais, France
DELCOUSTAL JM.,; GEC Alsthom; Aix-Ies-Bains, France
BROUET J.,; Alcatel Contracting; Clichy, France
Development of HV and EHV single piece premoulded joint
VASSEUR E.,; Alcatel Câble; Calais, France
CHATTERJEE Shotu; Alcatel Euromold; Belgium
Failure series analysis of wrap type cable joints on a 110 kV XLPE cable system
MENNEL H.,; VKW; Bregenz, Austria
From gas insulated switch· gear to cross-country cables
KOCH H.; Siemens; Erlangen, Germany
COUSIN V.; GTMH; France
420 kV three-phase compressed nitrogen insulated cable
THURIES E., PHAM V.D., ROUSSEL P., GUILLEN; GEC ALSTHOM T&D; Villeurbanne, France
Coordination of three· phase gas insulated line (TPGIL) insulation with levels of affecting overvoltages and characteristics of ZnO arresters
KADOMSKAYA K.P., NABOKOV S.-L., VOITOVITCH RA.; Novosibirsk StateTechnical University; Novosibirsk, Russia
Gas insulated cables : from the state of the art to feasibility for 400 kV transmission lines
AUCOURT C., BOISSEAU C., FELDMANN D.; EDF/DER; Moret-sur-Loing, France
Effect of DC testing on XLPE insulated cables
SRINIVAS N. Nagu; Detroit Edison Company; Detroit, USA
BERNSTEIN B.S.,; EPRI; Washington DC, USA
DC Testing of XLPE insulation
PARPAL J.L., GUDDEMI C., AMYOT N., DAVID E.; IREQ; Varennes Québec, Canada
Study On detection for the defects of XLPE cable links
KOBAYASHI S., UCHIDAK, KAWASHIMA T.; Chubu Electric Power; Nagoya, Japan
HIROTSU K., INOUE H.; SumitomoElectric Industries; Osaka, Japan
TANAKA H., SAKUMA S.; The Furukawa Electric Co.; Tokyo, Japan
An optical technique for insitu measurement of the concentration of the crosslinking by products in XLPE cables
BAMJI S.S., BULINSKI A.T.; NationalResearch Council of Canada; Ottawa, Canada
Recommended after Laying test methods for HV XLPE Cable Line
KARASAKI T., TOYA A.; Tokyo ElectricCo.; Tokyo, Japan
JINNO M., ASARI K.; Kansai Electric Co.; Osaka, Japan
MIYATA E., SHIMOHIRO D.; Chubu Electric; Nagoya, Japan
YOSHIDA T.; Furukawa Electric Co; Tokyo,Japan
KAKUTA M.,; Mitsubishi Cable Ind. Ltd; Kumagaya, Japan
KOJIMA T.,; Furukura Ltd; Japan
Some factors for the space charge formation of polyethylene
TAKAHASHI T., MIYATA H., NAKATUKA T., YOKYOYAMA A.; Fujikura Ltd; Tokyo, Japan
Space charge distribution in single water-trees measured by laser-induced pressure pulse method
RENGEL U.,; Brugg Kabel; Brugg, Switzerland
Study of the origin of space charge created during preparation of polyethylene plaques
VELLA N., TOUREILLE Alain; Laboratoire d'Electrotechnique de Montpellier; Montpellier, France
NILSSON U.H.; BOREALIS Polyeten; Stenunqsund, Sweden
Space charge measurement in XLPE cable with 9 mm thick insulation
HOZUMI N., TAKEDA T., SUZUKI H., OKAMOTO T.; CRIEPI; Kanagawa, Japan
WATANABE Kazuo, WATANABE Akitoshi, MIYATA H.; Fujikura Ltd; Chiba, Japan
Study of the electrode insulator interfaces by simultaneous measurement of external current and of space charge distributions
MORIN P., ALQUIÉ C., LEWINER J.,; ESPCI; Paris, France
Measurement of space charge distributions under 50 Hz AC stress
BERT C., HENNION C.; HLP; Paris, France
LEWINER J., ALQUIÉ C.; ESCPI; Paris, France
HAMPTON N.; BICC Cables Ltd; Erith, UK
FREESTONE J.; BICC Cables; Clwyd, UK
VERNE S.; BICC plc; Herts, UK
Oxidation and its effect on charge trapping in low density polyethylene
CARTWRIGHT GA, DAVIES A.E.; University of Southampton; Southampton, U.K.
SWINGLER S.G.; National Grid Co.; United Kingdom
Influence of aging over the morphology of XLPE
ROBERTSON Ch.; Ecole Polytechnique de Montréal; Canada
FOURNIER D., LAMARRE L.; IREQ; Varennes Québec, Canada
Electrical breakdown strength evolution of HV XLPE cable after long-term test. Correlation with physical properties
BEZILLE J., BECKER J., JANAH H.; Alcatel Câble; Calais, France
CHAN J., HARTLEY M.; Alcatel CanadaWire; Toronto, Canada
Study on deterioration mechanism of XLPE cables
KAMINAGA K., YOSHIFUJI N.,; The TokyoElectric Power Co.; Yokohama, JAPAN
UOZUMI T., YORITA J., FUKUNAGA S.; Sumitomo Electric Ind.; Osaka, Japan
Influence of temperature on accelerated aging of XLPE and EPR insulated cables under wet conditions
BERNSTEIN B.S., SAMM R.W.; Electric Power Research Institute; Palo Alto, CA, USA
Performances of XLPE under high voltages stress
FOURMIGUÉ JM., VERDIEREN., DELOOF A,; EDF/DER; Moret-sur-Loing, France
BERDALA Jacques, DEJEAN Pierre-Marcel; Câbles PIRELLI; Sens, France
Electrical treeing in mechanically stressed polyethylene
DAVID E., PARPAL JL., CRINE JP.,; IREQ; Varennes Québec, Canada
Electroluminescence on XLPE
MATSUMOTOT., SUZUKI H.,MATSUKI M.,; Furukawa Electric Co.,; Chiba, Japan
BAMJI S.S., BULINSKI T.,; NATIONAL RESEARCH COUNCIL; Ottawa, Canada
Thermal and electromechanical effects on dielectric strength of high density polyethylene under D.C. electrical field
HOANG THE GIAM, ESSOLBI R., ZEBOUCHI N., MALEC D., BUI AI.; Univ. P.Sabatier; Toulouse, France
Qualification and life duration determination of thin sheeted extruded material under high electrical field
FOULON-BELKACEMI N., GOLDMAN M., GOLDMAN A.; CNRS/SUPELEC; Gif-sur-Yvette, France
GATELLET J.; Merlin Gerin; Grenoble, France
Non-destructive control applied on power station cables : Assessment of the residual mechanical properties of cables
BERTRAND Y., PINEL B., BRINCOURT T.; EDF/DER; Moret-sur-Loing, France
Cable fault prevention using dielectric enhancement technology
MOKRY S.; CPS; San Antonio, USA
CHATTERTON W.; Dow Corning Corporation; Auburn, USA
CARTER S.; Duke Power Company; Charlotte, USA
SIBBALD P.; EDON; Groningen, The Netherlands
CLEMMER J.; OG&E Electrical Services; Oklahoma City, USA
BERTINI G.,; UtilX Corporation; Kent, WA, USA
GEORGE P.,; Virginia Power Company; Richmond, USA
Diagnosing power cable polyethylene insulation by electroluminescence monitoring
MARY D., LAURENT C., MAYOUX C.; Université Paul Sabatier; Toulouse, France
BERDALA Jacques; Câbles Pirelli; Paron, France
CLAVREUL R.,; EDF/DER; Moret-sur-Loing, France
Plasma-induced surface luminescence as a tool for high voltage synthetic insulation characterisation
MARY D., MASSINES F.,LAURENTC., MAYOUXC.,; Université Paul Sabatier; Toulouse, France
JANAH H., BEZILLE J.; Alcatel Cable; Calais, France
Thermal ageing monitoring of LOCA cables
CHAILAN JF., BOITEUX G., CHAUCHARD J., SEYTRE G.; Université C. Bernard,; Villeurbanne, France
PINEL B.; EDF/DER; Moret-sur-Loing, France
Insulation diagnosis of XLPE cables by expert system using fuzzy interference
CHOI Y.C., KUBOTA H., OHYAMAR.I.; Tokai University; Kanagawa, Japan
KANEKO K.; Kyushu Tokai University; Kumamoto, Japan
LEE J.B.; Wonkwang University; Iri, Korea
Laminated sheathed cable for replacement of lead sheathed cable in medium voltage applications
SMITH J., BOW K.; The Dow Chemical Co.; Granville, OH, USA
Chemical and moisture resistant medium and low voltage cables
VOLTZ D., BOW K.; The Dow Chemical Co.,; Granville, OH, USA
Development of dry-type transition joints for 22 kV CV cable and SL cable
YOKOSUKA K., YOKOYAMA T.,; Tokyo Electric Power Co.; Tokio, Japan
SAKURAI H., KASHIMOTO M., TAGO M.; The Furukawa Electric Co.,; Hiratsuka,Japan
Development of underground MV network : cable environment and new electrical equipment for rural networks
BONIFACE P., BRINCOURT T., PRUNIERE J-Y.; EDF; France
Technical and economical evaluation of different cable design for 1 kV distribution cables in Spain
MONJO J.,; UNESA; Spain
MONTEYS J., SARRO J., AZPEITIA J.; FACEL; Barcelona, Spain
First field experience and evolution of cold shrinkable MV joints
LEQUEUX Jean-Michel; Câbles Pirelli; Marne-la-Vallée, France
PARMIGIANI Bruno, VALLAURI U.; Pirelli Cavi; Milano, Italy
Development of new 12/20 kV protected aerial lines
DELAUNOIS G.; Câbleries de Lens; Noyelles, France
BACNUS R.; EDFGDF Services; Merignac, France
Covered and insulated cables for overhead distribution
TARALLI C., GODINHO C.A.F., CUNHA AP.; Pirelli; Sao-Paulo, Brazil
European and North American MV EPR power cable comparisons
DEL CORSO D.; BICC CEAT CAVI; Settimo, Italy
FLENNIKEN C.L.; BICC Cables; Indianapolis, USA
VERNE S.,; BICC; Londres, U.K.
Design and installation of 22 kV power cables, for LUL
JOURNEAUX Terence L.; Pirelli Cables; Eastleigh, United Kingdom
FIELD C.J.; London Underground; London, U.K.
CORBELLINI F.; Pirelli Construction; Eastleigh, United Kingdom
PE and XLPE .médium voltage cables- Service experience and examination of insulation state
RAKOWSKA Alexandra; TU of Poznan; Poznan, Poland
Developments in MV accessories
CROUZET G., CHARLES F.; Silec; Montereau, France
The effect of preconditioning on the performance of MV-XLPE cables in long term water treeing tests
BENJAMINSEN J.T., FAREMOH.; EFI; Norway
OLSEN J.A.; EnFO; Norway
MIKKELSEN N.P.; EiselskabetBHHH; Danemark
OLSSON L.; Goteborg Energi AB; Sweden
Electrical long-term test in Germany
KOBER H.; Felten & Guilleaume Energietechnik AG; Kain, Germany
An accelerated ageing test on the basis of 500 Hz for water treeing in cables
BANKS V.A.A.; BICC Cables; Wrexham, UK
FAREMO H.; Norwegian ElectricPowerResearch Inst.; Trondheim, Norway
STEENNIS Evert Frederik; KEMA; Arnhem, The Netherlands
Comparative long-term testing on 20 kV XLPE cables
SCHÂDLlCH H.; Alcatel Kabel; Hannover, Germany
Long duration immersion tests of cross-linked polyethylene insulated MV cables
AUDOUX C.; Silec; Montereau, France
FONDEUR Jean-Hubert; Câbles Pirelli; France
LEROY JH.,PINET A.; EDF; France
SIMEON Eric; Alcatel Cable; France
The behaviour of dry insulation medium voltage cables in a moist environment
URTUBI JM., REOLID G.; Iberdrola; Bilbao, Spain
SARDA J.; Asinel; Madrid, Spain
VALLS F.; Câbles Pirelli; Barcelona, Spain
Material development for the new cold shrink technology
CHÉENNE-ASTORINO A., CHATTERJEE Shotu., DE SCHRIJVER I.; Euromold; Erembodegem, Belgium
MIREBEAU Pierre, ALADENIZE B.; Alcatel Alsthom Recherche; Marcoussis, France
Materials for cables based on polymeric conductors
ALADENIZE B., ASSIERJC., GALAJ S.; Alcatel Alsthom Recherche; Marcoussis, France
MIREBEAU Pierre, JANAH H.; Alcatel Câble; Calais, France
Parameters influencing the strippability of conductive compounds for insulation shields
FAGRELL O.; Borealis; Stenungsund, Sweden
Peel test for semiconductive shields
CHINH.H., WHITEHOUSE R.S.; Cabot Corp.; Billerica, USA
New Polyolefin polymers for low and medium voltage power cables
HEMPHILL J.; Dow Chemical Co.,; Freeport, USA
FANICHET L, LANDUCCI D.; Dow Europe; Horgen, Switzerland
Crosslinking mechanisms in low density polyethylene
GUSTAFSSON B.; Borealis Polyeten; Stenungsund, Sweden
SMEDBERG A, HJERTBERG T.; Chalmers TU; Goteborg, Sweden
Correlation between residual mechanical stresses and properties of XLPE insulated cables
CAMPUS A, DRUOT P.; Borealis; Anvers, Belgium
LENNARTSON H.; Borealis; Stenungsund, Sweden
New insulating materials for HV cables
JANAH H., MIREBEAU Pierre; Alcatel Cable; Calais, France
GADESSAUD R, BARRAUD J:-Y., TRAN P.; Alcatel Alsthom Recherche; Marcoussis, France
BALOG G., PEDERSEN JR; Alcatel Kabel Norge; Halden, Norway
The utilization of crosslinked plastic materials by means of the nuclear radiations in the construction of the cables
GAVRILA D.E.; University Politehnica; Bucarest, Romania
Advantages of hot melt adhesives for overlap bonding and sealing in power cables
BUTTERBACH R.; Henkel KGaA; Düsseldorf, Germany
HEUCHER R.; HENKEL Corp.; La Grange, USA
Simple monitoring method of underground cables
PISPIRIS C.S.; ICEMENERG; Bucarest, Romania
Electric field measurements on MV and HV components with an electro-optic sensor
MAILAND M., ZAENGL W.; ETH Zürich; Zürich, Switzerland
AUMEIER W.; Raychem; Munich, Germany
Behaviour of electric cables under fire conditions
FAVRIE C., BILES O.,; Silec; Montereau, France
A critical assessment of IEC 332-3 (1992), the Italian standard CEl 20-22 (1987) and the requirements of EEC construction products directive from the fire
propagation point of view
FARNETI F.; ENEL; Milano, Italy
VERCELLOTTI U.; CESI; Milano, Italy
Fire risk analysis on MV cable networks : the behaviour of joints in case of fault
FARA A., MIOLA G.; ENEL; Rome, Italy
VERCELLOTTI U.; CESI; Milano, Italy
Characterisation techniques of non-ceramic outdoor insulation, application to cable terminations
FOURMIGUÉ JM., NOEL M., RIQUEL G., LE PEURIAN S.; EDF/DER; Moret-sur-Loing, France
Electrical properties & recommended test methods for HV XLPE cable and accessory
KARASAKI T., TOYA A.; Tokyo Electric Co.; Tokyo, Japan
JINNO M., ASARI K.; Kansai Electric Co.; Osaka, Japan
MIYATA E., SHIMOHIRO D.; Chubu Electric; Nagoya, Japan
WATANABE M., FUDAMOTOK.; Sumitomo Electric Ind.; Osaka, Japan
OSOZAWA K., WATANABE Y.; Hitachi Cable Ltd; Hitachi, Japan
KIHARA T., SAKAGUCHI Y.; Showa Electric Wire & Cable; Kawasaki, Japan
New design of UHV water graded cable test terminations
MOHAUPT Peter, GLEYVOD R.; Haefely Trench; Basel, Switzerland
A review of electrical accelerated ageing data for extruded dielectric cables
PARPAL J.L., DANG C., CRINE JP.; IREQ; Varennes Québec, Canada
Characteristics of field aged medium-voltage cables
PELISSOU Serge; IREQ; Varennes Québec, Canada
Assessment of cable condition by propagation characteristics spectroscopy (PCS)
MASHIKIAN Matthew S., FOSTER S.,; University of Connecticut; Connecticut, USA
Investigations of accelerated ageing of XLPE insulated HV cables under conditions of long-term tests and actual use
VASILIEV N., MAVRIN M., OBRAZTSOV Y., OVSIENKO V,. SHUVALOV M.,; VNIIKP; Moscow, Russia
Development of service life prediction methods for oil-filled cables
POPKOV V.I., PRIVALOV I.N., SHATALIN GA.; HVDC Power Transmission Research Institute; St Petersburg, Russia
Diagnostic field testing of paper-insulated lead-covered MV cable
HETZEL E.; KEMA; Arnhem, The Netherlands
Mac KINLAY R.; EATL; Capenhurst, U.K.
The limits of an ageing study on polyethylene material
DUCHATEAU Francis & Co-authors; EDF/DER/ERMEL; Moret-sur-Loing, France
Optimization of physical and chemical procedures for the study of polyethylene ageing, insulation for power cables
DUCHATEAU Francis & Co-authors; EDF/DER/ERMEL; Moret-sur-Loing, France
Examination and diagnostics of service aged 11 kV XLPE insulated cables
NAYBOUR R.D., ROBINSON G.; EA Technology; Capenhurst, U.K.
Investigation of XLPE insulations after high stress ageing
SCHÂDLlCH H., KLASSJ.; Alcatel Kabel; Hannover, Germany
Dissipation factor of accelerated aged XLPE power cables
NILSSON U.H.; BOREALIS Polyeten; Stenungsund, Sweden
MARSDEN E.; Borealis Compounds Inc.,; Port Murray, USA.
FAREMO H.; EFI; Trondheim, Norway
Diagnostic techniques for service-aged XLPE insulated medium voltage cables
KUSCHEL M., PLATH R., STEPPUTAT L, KALKNER W.; TU of Berlin; Germany
Radial and angular study of XLPE in HV cables by the thermal step method
CASTELLON J., MALRIEU S.; LEM; Montpellier, France
Processing of high smoothness furnace blacks for semiconducting shields
GREENE S.;Cabot Corp.,; Billerica, USA
RICHARDSON Colin G., GRUETTER H.; BUSS; Basel, Switzerland
Design for an electric cable for coal cutting machine 5 kV
MUSQUIN M.; Silec; Montereau, France
SALZMANN H.; HBL; Merlebach, France
Cables for nuclear power stations
JOURNEAUX Terence L.; Pirelli Cables; Eastleigh, United Kingdom
Insulation of high temperature cables for car applications
BENARD Laurent, COLOMBIER Serge, GALCERA Thierry; Câbles Pirelli; Sens, France
LEPATEY M.; Sté Française des Plastiques; Angy, France
Cable for provisional supply transformer integrated in tow
DEMAYJ-N., CARRIERE R,; Alcatel Câble; Lyon, France
Development of halogen free flame-retardant cables for nuclear power plants
AIDA F., YOSHIDA, MINAMI M., NAKAYAK., TAMUKAI K.; Showa Electric Wire & Cable; Kawasaki, Japan
Pulling forces of 25 . kV distribution cables layed in conduits
ORDANESCU M., TARNOWSKI J., NOURRY J.; IREQ; Varennes Québec, Canada
Optimization of the insertion of insulated HV and EHV cables in overhead lines
DORISON Eric, FANG R.; EDF/DER; Moret-sur-Loing, France
Thermal performance of underground power cables with constant and cyclic currents in presence of moisture migration in the surrounding soil
FREITAS D., PRATA A.; Federal University of Santa Catarina; Florianopolis, Brazil
DE LIMA A.; Pirelli SA.; Santo André, Brazil
Forecasting & probabilistic rating of underground power cables
BLACKWELL A, DAVIES A.; University of Southampton; Southampton, UK
LARSEN S.T.; The National Grid Co.; UK
Optimization of expansion loops of 120 kV XLPE cables
TARNOWSKI J., IORDANESCU M., HARDY C., NOURRY J.; IREQ; Varennes Québec, Canada
Study of electric field in critical zones of HV cables by 3D finite elements methods
MORALES N., FERNANDEZ J., ASENJO E., VALDENEGRO A.; University of Chile; Santiago, Chile
A practical model for the lifetime prediction of LOCA (EPDM. CSPE) and (PVC) cables in nuclear power stations
PINEL B., BOUTAUD F.; EDF/DER; Moret-sur-Loing, France
Plasticizers diffusion kinetic for PVC cables : correlation between electrical properties and plasticizers migration
BENHABILES K., PINEL B.; EDF/DER; Moret-sur-Loing, France
On the field distribution in a coaxial DC power cable
COELHO R.,; Alcatel Alsthom Recherche; Marcoussis, France
MIREBEAU Pierre; Alcatel Câble; Calais, France
Thermal analysis of high voltage cables with XLPE insulation based on non-linear thermal characteristics of materials
LARINA E.T., OVSIENKO V., SHUVALOV; VNIIKP; Moscow, Russia
Evaluation and optimization of transmission capacities of power link
ARGAUT P., LESUR F.,; Silec; Montereau, France
Full-scale study of thermal behaviour of MV tri-polar cables laid in conduits
DARDEL B., VELUZAT G., KRÂHENBÜHL F.; Câbles Cortaillod; Cortaillod, Switzerland
Determination of the internal thermal resistivity of a three-core insulated paper cable
BRINCOURT T., LEROY J-H.; EDF/DER; Moret-sur-Loing, France
Magnetic field modelling and management for transmission underground cables
FARAG A.S., AL-SHEHRI A.M., BAKHASHWAIN J.; King Fahd Univ. Of Petroleum & MineraIs; Dhahran, Saudi Arabia
CHENG T.C., ZHENG G., CURCI V., GHAEMI M., KHAJAVI M.; University of Southern California; Los Angeles, USA
Rating of cables on riser poles
ANDERS G.; Ontario Hydro Technologies; Toronto, Canada
Investigations on breakdown strength of polyethylene at very fast transients
GARROS B.; Alcatel Alsthom Recherche; Marcoussis, France
LAND H.G.; Alcatel Kabel; Hannover, Germany
PEDERSEN J.R.,; Alcatel Kabel Norge; Halden, Norway
Partial discharge location as a cable operating tool
MASHIKIAN Matthew S.; University of Connecticut; Connecticut, USA
VALDES G., GONZALEZ V.; Florida Power & Light Co.; USA
KATZ C.;Cable Technology Labs.; New Brunswick, NJ, USA
Development of a partial discharge automatic-monitoring system for EHV XLPE insulated cable lines
TOYA A., GOTO T.; Tokyo Electric Power Co.; Tokyo, Japan
ENDOH T., SUZUKI H., TAKAHASHI K.; Hitachi Cable Ltd; Ibaraki, Japan
Partial discharge in medium voltage extruded cable joints
LAMARRE Laurent, MORIN R.; IREQ; Varennes Québec, Canada
HF partial discharge detection of HV extruded cable accessories
PULTRUM E.; KEMA; Arnhem, The Netherlands
VAN RIET M.J.M.; NUON; Duiven, The Netherlands
Ultra-wide bandwidth PD measurements application to open air testing of 230 kV XLPE cables
BRAUN JM., HORROCKS D.J., LEVINE JP., SEDDING H.G.; Ontario Hydro Tech.; Toronto, Canada
HIIVALA L., HARTLEY M.; Alcatel CanadaWire; Toronto, Canada
Measurement and location of partial discharges during on-site testing of XLPE cables with impulse voltages
KRAGE 1., STREHL T., KALKNER W.; TU of Berlin; Germany
Investigation of the effects of electrode type and temperature on the remanent electric field in low density polyethylene using the thermal step method
KHALIL M.S.; Sultan Qaboos University; Muscat, Sultanate of Oman
CHERIFI A.; Université de Caen; Octeville, France
TOUREILLE Alain, REBOUL J.-P.; Université de Montpellier Il; Montpellier, France
Characterization and diagnostic of HV and VHV cables by the thermal step method
TOUREILLE Alain; Univ. Montpellier Il; Montpellier, France
SANTANA José, BERDALA Jacques; Câbles Pirelli; Sens, France
Space charge measurement of HV and EHV XLPE cables submitted to ageing under high stress
SANTANA José, BERDALA Jacques; Câbles Pirelli; Sens, France
TOUREILLE Alain; Université Montpellier Il; Montpellier, France
Influence of annealing on the electric behaviour of low density polyethylene
MORIN P., ALQUIÉ C., LEWINER J.; ESPCI; Paris, France
ARGAUT P.; SILEC; Montereau, France
Results of tests using continuous high voltage on low density polyethylene insulation
BOURGEAT X.; EDF/DER; Moret-sur-Loing, France
LUTON M-H.; SILEC; Montereau, France
Evidence of a strong correlation between space charge build· up and breakdown in cable insulators under DC stress
ZHANG Y., LEWINER J., ALQUIÉ C.; ESPCI; Paris, France
HAMPTON N.; BICC Cables Ltd; Erith, UK
Precursor phenomena on the breakdown of polyethylene
VELLA N., TOUREILLE Alain; Lab. d'Electrotechnique de Montpellier; Montpellier, France
ZEBOUCHI N., HOANG THEGIAM; Lab. de Génie Electrique; Toulouse, France
Effects of the UV radiation on PE and crosslinked polyethylene (XLPE) cables aged in humid environment
PENTEADO RA, ENGELSTEIN E.; COPEL/LAC; Paranà, Brazil
DAS-GUPTA DK,; University of Wales; Bangor, U.K.
Generation of colored trees under the influence of additives and impurities
TOYA A., KARASAKI T.; Tokyo Electric Power Co.; Tokio, Japan
TANIMOTO G., AIDA F.; Showa Electric Wire & Cable; Kawasaki, Japan
Water diffusion through sheaths and its effects on cable constructions
GEURTS W.S.M., STEENNIS E.F., POORTS C.J.H.M., MEIJER G.J.; KEMA; Arnhem, The Netherlands
Medium voltage polymeric power cables. Clarification of the cause of water treeing and methods of its prevention
DEJEAN Pierre-Marcel; Câbles Pirelli; Sens, France
BANKS VAA,; BICC Câbles; Clwyd,U.K.
MAYOUX C., MARTINEZ J.; Université Paul Sabatier; Toulouse, France
FOURACRE RA,; University of Strathclyde; Glasgow, U.K.
PEDROSO F.; CEL-CAT Morelana; Pero Pinheiro, Portugal
Water treeing acceleration vs. right temperature gradient
RYNKOWSKI AW.; TU of Gdansk; Poland
Light emission and electrical tree initiation in highly-stressed XLPE cable insulation
KABIR F., BRAUN JM., DENSLEY J.; Ontario Hydro; Toronto, Canada
HAMPTON N.; BICC Cables Ltd; Erith, UK
VERNE S.; BICC Plc; Hemel Hempstead, UK
Characterisation test on MV XLPE insulated cables
SISWADI; PT PLN; Jakarta, lndonesla
Halogen free new recyclable cable with low toxic gas emission
YOSHINO A., SAWADA H., SUZUKI J., HASEGAWA M., MURAYAMA M., SHINMOTO T.; Fujikura Ltd.,; Tokyo, Japan
Development of recyclable low-voltage insulated cable
YUKAWA H., OHASHI T, SAKASHITA H., KAMINO K.; The Kansai Electric Power Co. Inc; Osaka, Japan
HIURA T, SHIRATSUCHI N.; Sumitomo Electric Ind.; Osaka, Japan
Consideration of environmental impacts in the cable design
BRIX S.; Alcatel Kabel; Nürnberg, Germany
DUBOTS P, NOËL B., PARASIE Y.; Alcatel; Paris, France
Life cycle analysis of power cables in Norway
GJAERDE «c, SOLVANG E., VERLO T.; SINTEF Energy Research; Trondheim, Norway
Shielding technique to reduce magnetic fields from buried cables
ARGAUT P, DAURELLE J.Y.; SAGEM SA; Montereau, France
PROTAT E, SAVINA K., WALLAERT C.A.; SUPELEC; Gif sur Yvette, France
Cables and electromagnetic compatibility into aircraft
BRAIDOTTI V., ZANINELLI D.; Politecnico di Milano; Italy
Completion of 500 kV XLPE cable links for the Okutataragi power generating station
SAKAGUCHI Yasuo, MIYAZAKI Toshihiro, ASAI Shinya; Sumitomo Electric Industries Ltd.; Osaka, Japan
NISHI Minori, NAKAZAWA Makoto, OKADA Masahiko; The Kansai Electric Power Co. lnc.,; Hyogo, Japan
400 kV XLPE cables for the extension of Cleuson-Dixence Hydro power plants
WYLER c., BIOLLEY c.. HEIZMANN T, MARRO A,; Alcatel Cable Suisse SA; Cortaillod, Switzerland
NICOLET A.; Aménagement Cleuxon-Dixence; Sion, Switzerland
The high voltage cables in the Ivorian power system
DIARRASSOUBA A,; Compagnie Ivoirienne d'Électricité; Abidjan, Ivory Coast
Installation of 400 kV XLPE cables in the NESA supply area
CHRISTENSEN P, LAGERSTEDT K., OKHOLM A.; NESA A/S; Gentofte, Denmark
Design of new 150 kV XLPE cable system for the Belgian electrical network
COUNESON P, BRUS B.; Tractebel; Bruxelles, Belgium
ARGAUT P, MARTIN B.; SAGEM SA; Montereau, France
Construction of long distance 500 kV XLPE cable line
OHATA K, TSUCHIYA S.; Tokyo Electric Power Co. Ltd.,; Tokyo, Japan
SHINAGAWA N.; The Furukawa Electric Co. Ltd.,; Tokyo, Japan
FUKUNAGA S.; Sumitomo Electric Industries Ltd.,; Tokyo, Japan
OSOZAWA K.; Hitachi Cable Ltd; Tokyo, Japan
YAMANOUCHI H.; Fujikura Ltd.; Tokyo, Japan
The design of power cables to operate at high electrical stress
DEMARIA G.; BICC Ceat Cavi; Italy
GREGORY B., GRIFFITHS c.t.. HAMPTON R.N., MAINWARING S.P.; BICC Cables Ltd; Erith, UK
State of the art in EHV XLPE cable systems
BOLZA A,; Pirelli Cavi S.p.A,; Italy
KUNZE D.; Pirelli Cable and Systems;
NORMAN S.; Pirelli Cavi e Sistemi; Milano, Italy
POHLER S.; Pirelli Kabel und Systems; Germany
Prequalification testing of 290/500 (525) kV extruded cable system at IREQ
PARPAL J.L.; Hydro-Québec (lREQ),; Québec, Canada
BEZILLE J., GAHUNGU F., BECKER J., MIREBEAU P.; Alcatel Cable; Calais, France
CARDINAELS J.,; Alcatel Euromold; Erembodegem, Belgium
MEURER D.,; Alcatel; Germany
Qualification of a new technical step cable system for the 90 kV network
BEZILLE J., COELHO D., GAHUNGU F., MIREBEAU P.; Alcatel Cable; Calais, France
CARDINAELS J.; Alcatel Euromold; Erembodegem, Belgium
Qualification test program of 115 kV rated, 3500 kcmil and 138 kV rated, 1500 kcmil high-pressure gas-filled cables
AHMED N., SRINIVAS N.; Detroit Edison Company; Detroit, USA
KUCHTA Frank L., CINQUEMANI P.; Pirelli Cable Corporation; Lexington, USA
Technological advances in reliable HV XLPE foil laminate cable systems
FORD A,; Formerly with London Electricity; United Kingdom
GREGORY B., KING S.M., SVOMA R.; BICC Cables Ltd; United Kingdom
Gas-insulated transmission lines (GIL). Type tests and prequalification
SCHÜETTE A, KOCH H.; Siemens AG; Erlangen, Germany
Optimized gas-insulated transmission line
GUILLEN M.; Alstom T&D; Villeurbanne, France
BERTRAND M.; Alstom T&D; Aix les Bains, France
Long term test of a directly buried GIL prototype
BOURDET M., HOPKINS M.; ABB Énergie; La Défense, France
FELDMANN D.; EDF DER; Moret sur Loing, France
MAUGAIN Yves; EDF Production Transport; Courbevoie, France
Development of a high temperature superconductivity power delivery system
HUGHEY R.L.; Southwire; Carrollton, USA
Latest development of high temperature super conductor (HTSC) cable systems
LADIE PL., NASSI M., NORMAN S.R.; Pirelli Cavi e Sistemi; Milano, Italy
SCHROTH R.G.; Pirelli Kabel und Systems; Berlin, Germany
Pirelli-EDF DEVELOPMENT on superconducting cables
LADIE PL., NASSI M., NORMAN S.R., CARACINO P.; Pirelli Cavi e Sistemi; Milano, Italy
COVOET M., BOISSEAU C., SIROT P.F.; EDF DER; Moret sur Loing, France
Design of a high temperature superconducting cable termination
HATHAWAY G.M., DAVIES A.E.; University of Southampton; Hampshire, United Kingdom
SWINGLER S.G.; The National Grid; Leatherhead, Surrey, UK
European superconducting power link project
VERHAEGE T., HERRMANN P.F.; Alcatel; Marcoussis, France
BOCK J., BAECKER M.; Aventis; Hürth, Germany
MOULAERT G.; Laborelec; Linkebeek, Belgium
FREYHARDT H.C., USOSKIN A.; ZFW GmbH; Gbttingen, Germany
LEHTONEN J., PAASI J.; TUT; Tampere, Finland
Thermomechanical modelling of 345 kV XLPE cables in duct
TARNOWSKI J, IORDANESCU M., AWARD R., ROYER C.; Hydro-Québec (lREQ),; Québec, Canada
Thermomechanical behaviour of 400 kV synthetic cables
BRINCOURT T, DORISON E.; EDF DER; Moret sur Loing, France
New mechanised laying techniques of MV cables with geosynthetic protection
BRINCOURT T.; EDF DER; Moret sur Loing, France
ROBIN J.C.; MARAIS; Miré, France
BOUCHER M.,; RIMAUDIERE; Mios, France
LEFLAIVE E., PUIG J.; Ingénieurs Conseil; France
Cable laying : State of art for the laying of HV and EHV cable systems
MAUGAIN Yves; EDF Production Transport; Courbevoie, France
HUDSON P.; Pirelli Construction; Eastleigh, United Kingdom
Installation of a new technical step 90 kV cable system. A real experience on the French network
BERDALA Jacques, DEJEAN Pierre-Marcel, MANSOUR Jawdat; Câbles Pirelli; Sens, France
MAXAN A.; Câbles Pirelli; Saint Maurice, France
Installation of 220 kV XLPE cables in a tunnel installation whilst Minimising electromagnetic induction in communication cables
GREGORY B.; BICC Supertention & Subsea Cables; Erith, UK
MONTEYS J.; BICC General Cables; Barcelona, Spain
BARRIS S.; Enher-Hec;
MENDEZ J.M.; Consultant;
400 kV insulated cable Link installation carried out at the Chaira pumped storage power plant in Bulgaria
LAVANTUREUX P., DEGUINES P., GAHUNGU F.; Alcatel Cable; France
TODOROV T,; Nationalna Elektricheska Kompania; Sestrimo, Bulgaria
The mechanical laying of underground high voltage cables (63 and 90 kV) in France
FIGARET Christophe; EEE; Nîmes, France
170 kV common termination system for cables with extruded insulation
DE RIDDER E.; Alcatel Euromold; Erembodegem, Belgium
MONSEN O.B.; Alcatel Norge; Oslo, Norway
Development of prefabricated joint for 500 kV XLPE cable
OKADA M.; The Kansai Electric Power Co. Inc; Osaka, Japan
SATO M.,; Sumitomo Electric Ind. Ltd.,; Osaka, Japan
YAMASHITA Y.; The Furukawa Electric Co. Ltd.,; Chiba, Japan
HARA M.,; Hitachi Cable Ltd; Ibaraki, Japan
NIINOBE Hiroshi; Fujikura Ltd.,; Chiba, Japan
Development of high stress cable and accessories for EHV XLPE cable systems in Korea
YOON H.H., KWAK B.M.; KEPCO; Seoul, South Korea
OH J.O., CHOI S.G., HUH G.D., PARK W.K.; LG Cable; Korea
Development of synthetic and composite terminations for HV and EHV extruded cables
LE PEURIAN S.; EDF DER; Moret sur Loing, France
JUNG M.; EDF Production Transport; Courbevoie, France
Operating experience with lapped high voltage cable joints made from EPR tapes
JENNI A.; Hivotec Ltd; Binningen, Switzerland
RENGEL U., MEIER A.; Brugg Kabel AG; Brugg, Switzerland
OSLEY J.; MOS Engineering AG; Mellingen, Switzerland
Development of sheath-interrupter for EHV cables
YUKIHIRO K., TAKAYUKI K.; Chubu Electric Power Co. lnc.,; Nagoya, Japan
KOICH K., TOSHIMITSU T,; Hitachi Cable Ltd; Japan
Development of block molded joint for 275 kV XLPE cable and its application to actual line
TSUCHIYA S., YONEMOTO N.; Tokyo Electric Power Co. Ltd.,; Tokyo, Japan
SHIMOMURA T, NAKAMURA S.; Mitsubishi Cable Ind. Ltd.,; Tokyo, Japan
Eddy current losses
ARGAUT P., LESUR F.; SAGEM SA; Montereau. France
Advanced topics in rating of power cables
ANDERS G. BRAUN J.M., VAINBERG M., RIZETTO; Ontario Hydro Technoloqies; Toronto, Canada
BRAKELMANN; Gerhard-Mercartor-Universitat; Duisburg, Germany
Using the finite element method for complex cable ampacity calculations : A more accurate and much more flexible alternative to the conventional analytical
methods
CHAABAN M. LEDUC J.; Hydro Québec (IREQ); Québec, Canada
The additional losses in the metallic screens of high voltage cables
DEJEAN Pierre-Marcel; Câbles Pirelli; Sens, France
FONTANA M. REMY C. ZACCONE E.; Pirelli Cavi S.p.A.; Milano, Italy
Sirolex : A finite element computer program for the thermal analysis, design and monitoring of underground and aerial high and medium voltage insulated
cable systems
KEMP R.C. ; CSIRO National Measurement Laboratory; Lindfield, Australia
BARBER K.W., BARNEWALL G.D. JANSEN M. MUXWORTHY M. PIECHOTA R. SOETOPO Y,; Olex Cables; Tottenham, Australia
Simplified expressions for the evaluation of the cyclic ratings of low voltage and medium voltage cables in non sinusoidal conditions
CARAMIA P, CARPINELLI G. VERDE P.; University of Cassino; Italy
Transmission capacity design of underground power cables
OKADA M.; The Kansai Electric Power Co. inc; Osaka, Japan
KARASAKI T.; Tokyo Electric Power Co. inc; Tokyo, Japan
FURUHATA H.; Chubu Electric Power Co. inc; Aichi-Ken. Japan
IMAJO N.; Central Research Institute of Electric Power Industry; Kanagawa-Ken, Japan
MITANI M.; Sumitomo Electric Industries Ltd; Osaka, Japan
SAKUMA S.,; Furukawa Electric Co. Ltd; Tokyo, Japan
Potential overheating in the event of a cable crossing
THEVENON Henri; Consultant; Lyon, France
COUQUET JM.,; Alcatel Cable; Calais, France
Thermal design of controlled backfills
ARGAUT, P., LESUR F.; SAGEM SA,; Montereau, France
MERMET G., PROTAT F., SPORREL U.; SUPELEC; Gif sur Yvette, France
Pipe-type cables : retrofitting and ampacity
ARGAUT, P, LESUR F; SAGEM SA; Montereau, France
New applications of extruded solid dielectric cables
CARTENSSEN P, LEIJON M.; ABB Corporate Research; vasteras, Sweden
JOHANNESSON K.; ABB High yoltage Cables AB; Karlskrona, Sweden
SÖRQVIST T.; ABB Generation AB; vasteras. Sweden
Research of property of low-smoke halogen-free flame-retardant power cable
PING S.; Shenyang Cable Works; China
Updated status of the FIPEC project (Fire Performance of Electrical Cables)
VAN HEES P; Swedish National Testing & Research Institute, Fire Technology; Sweden
BREULET H.; Institut Scientifique de Service Public; Belgium
VERCELLOTTI U.; CESI; Milano, Italy
GRAYSON S., GREEN A.; Interscience Communications; United Kingdom
Water tree accelerated ageing tests for MV XLPE cables
STEENNIS Evert Frederik, GEURTS W.S.M., MEIJER G.J.; KEMA; Arnhem, The Netherlands
Development of oil sampling devices for energized oil filled cable system
OKADA M., TANAKA N., TAMURA K., TSUJI T.; The Kansai Electric Power Co. Inc; Osaka, Japan
IWAMOTOT; Sumitomo Electric Industries Ltd; Japan
HATA Toshio; The Kansai Tech. Co; Japan
Leak detection in high pressure pipe-type cables using artificial neutral networks
ANDERS G.J., BRAUN J.M., FISCHER D., RIZZETTO S., VAINBERG M.; Ontario HydraTechnologies; Toronto, Canada
GHAFURIAN R., TANG L.; Consolidated Edison Co.,; New York, USA
On-site partial discharge diagnostics of medium voltage power cables
GULSKI Edward, SMIT J.J.; Delft University of Technology; Delft, The Netherlands
SElTZ P.N.; Seitz Instruments &Co.,; Switzerland
KONING R.F.F.; NKF Kabel BV,; The Netherlands
TURNER M.; Haefely Trench AG,; Switzerland
On-site AC test after installation for long HV and EHV cables
VAN SCHAIK N., DE LIGT C. PULTRUM E.; KEMA; Arnhem, The Netherlands
Partial discharge measurement with freely oscillating resonance voltage
ONODI T, Dàtwyler AG.; Altdorf; Switzerland
Advanced measuring system for the analysis of dielectric parameters including PD events
LEMKE E., STREHL T.; Lemke Diagnostics GmbH; Volkersdorf, Germany
Achievements in operation of XLPE cables in Japan
OHATA K.; Tokyo Electric Power Co; Tokyo, Japan
NAKAGAWA S.; Kansai Electric Power Co; Osaka, Japan
FURUHATA H.; Chubu Electric Power Co; Nagoya, Japan
The influence of semiconductive screen materials on electrical performance
HAMPTON R.N., MOODY S.M.; BICC Cables Ltd; Erith, UK
FREESTONE J.; BICC Cables Corp; Indianapolis, USA
New grading material for terminations and joints
MOHAUPT Peter; High Voltage Engineering Ltd.,; Basel, Switzerland
GLEYVOD R.; High Voltage Engineering Ltd; Basel, Switzerland
RODER R.; CELLPACK AG,; Wohlen, Switzerland
New polyethylene compounds for cable jacketing applications
HENSCHKE O.,BARTSCHEK K., AARTS M.; DOW BSL Olefinverbund GmbH; Merseburg, Germany
Advanced polyethylene jacketing compounds for medium and high voltage cable applications
GAU Y,; Union Carbide Europe SA; Meyrin, Switzerland
PERSON TJ.; Union Carbide Corporation; Somerset, NJ, USA
KMIEC C.J.; Union Carbide Corporation; Somerset, NJ, USA
Medium and high voltage cables having laminate sheaths with coated copper
BOW Kenneth E.; The Dow Chemical Company; Midland, USA
Long term wet ageing of extruded dielectric cables
VAll J. , NOYES R.P., BANKS V.A A.; BICC Cables Energy; Wrexham, United Kingdom
HAMPTON R.N.; BICC Cables Ltd; Erith, UK
Evaluation of important aspects for the long term service performance of axially and radially water tight XLPE
FAREMO H., BENJAMINSEN J.T.; SINTEF Energy Research; Norway
STEEN A,; Nordhordland; Norway
OLSEN J.A.; Hadeland Energiverk; Norway
Moisture penetration in XLPE and PlLC cables
GEURTS W.S.M., ROSS R., MEGENS M.G.M., STEENIS E.F.; KEMA; Arnhem, The Netherlands
Local effects of water entering XLPE insulation through damaged sheaths
JORGENSEN H.J.; DEFU; lyngby, Denmark
JENSEN A,; NKT Cables; Denmark
STROBECH E.; NKT Research Center; Denmark
URSIN C.; CU Test & Development; Denmark
Water penetration in the insulation of medium voltage cables
PELISSOU Serge; Hydra-Québec (lREQ),; Québec, Canada
ST-ANTOINE S.; Hydra-Québec (Distribution),; Québec, Canada
Progress in quality of XLPE insulation for medium voltage cables
RAKOWSKA Alexandra, HAJDROWSKI K.; Poznan University of Technology; Poznan, Poland
Technical advancements in the underground medium voltage cable specifications of the USA largest investor owned utilities
DUDAS J.H.; Consultant; Longview, USA
COCHRAN W.H.,; Cinergy; Cincinnati, USA
Extruded MV cables and accessories with increased electrical stress
SCHADLICH H., MEURER D.; Alcatel; Hannover, Germany
KRAHENBÜHL F.; Alcatel,; Cortaillod, Switzerland
CHANEL J.; Alcatel; Bourg en Bresse, France
SCHIAFFINO P.; Alcatel; Latina, Italy
DE RIDDER E.; Euromold; Erembodegem, Belgium
BECKER J.; Alcatel,; Charleroi, Belgium
LAURENT M.; Alcatel; Cossonay, Switzerland
Modelling electric treeing in XLPE insulation using electric field concepts
GANGA S., NAGAMANI H.N., MOORCHING S.N.; Central Power Research Institute; Bangalore, India
A review of the influence of frequency on accelerated aging of PE and XLPE cables
CRINE Jean Pierre; Technology Consultant; Brossard, Canada
JOW J.; Union Carbide; USA
Aging of electrical underground distribution cable joints
AMYOT N., FOURNIER D.,; Hydra-Québec (IREQ),; Québec, Canada
AC field ageing of power cables
PARPAL J.L.; Hydro-Québec (lREQ); Québec, Canada
MIREBEAU Pierre, COELHO D., JANAH H., GAHUNGU F,; Alcatel Cable; Calais, France
CARDINAELS J.; Alcatel; Belgium
MEURER D.; Alcatel; Germany
Life estimation of water tree deteriorated XLPE cables by VLF (Very Low Frequency) voltage withstand test
UCHIDA K., KATO Y.; Chubu Electric Power Co., Inc; Aichi, Japan
TANAKA T., TANAKA A.; Tokyo Electric Power Co. Inc.; Yokahama, Japan
SAKAKIBARA H., TANAKA H.; The Furukawa Electric Co. Ltd.,; Chiba, Japan
Water treeing as diffusion-with-reaction process
SHUVALOV Mikhail, MAVRIN M., OBRAZTSOV Yuri; JSC VNIIKP; Moscow, Russia
New interpretation of long-term test results of MV cables : Material ageing or internal defect structure development
MORAWIETZ K.; Fraunhofer Institute for Mechanics of Materials; Halle, Germany
HEIDMANN G.; Kaiser KWO Kabel Energie GmbH; Berlin, Germany
RIECHERT U.; TU of Dresden; Germany
WUTZLER A.; Martin-Luther-University; Halle-Wittenberq, Germany
Assessment under high dielectric field of the long term behaviour of power cable polyethylene insulant
CLAVREUL R.; EDF DER; Moret sur Loing, France
LUTON M.H.; SAGEM SA; Montereau, France
BERDALA Jacques; Câbles Pirelli; Sens, France
JANAH H.; Alcatel Cable France; Calais, France
LAURENSON P.; Borealis; Zwinjdrecht, Belgium
The effect of temperature on dielectric characteristics of XLPE
TANAKA TI TANAKA A.,; Tokyo Electric Power Co.; Yokohama, Japan
SHIBATA T, HIROTSU K.; Sumitomo Electric Ind. Ltd; Osaka, Japan
About electrical conductivity related to heterogeneous bulk structure of polyethylene
BERTIN C, GUASTAVINO J., MAYOUX C.; Laboratoire de Génie Électrique de Toulouse; France
DRUOT P.; Borealis AB; Stenungsund, Sweden & Singapore
Evaluation of insulation degradation of stressed XLPE cables
GARROS B.; Alcatel CIT; Marcoussis, France
AUDRY C.; SAFT; Marcoussis. France
SCHADLICH H.; Alcatel Kabel; Hannover, Germany
MONTANARI Gian Carlo, BENCIVENNI L.; DIE, University of Bologna; Italy
Practical tool for cable ageing monitoring : dynamic mechanical analysis (DMA)
BOUTAUD F.; EDF DER; Moret sur Loing, France
CHAILAN J.F'I VERNET J.L.; Institut des Sciences de l'Ingénieur; Université de Toulon et du Var, France
Diagnosis of service aged XLPE cables. Presentation of a Nordic utility research project evaluating different on-site dielectric response diagnostic test
methods
FAREMO H.; SINTEF Energy Research; Trondheim, Norway
CHRISTENSEN J.S.; DEFU; Lyngby, Denmark
WERELIUS P.; KTH; Stockholm, Sweden
OBERGER K.; Elforsk AB; Stockholm, Sweden
MORTENSEN K.B.; CDP; Kvaloysletta, Norway
Evaluation of different diagnostic methods for the French underground MV network
BRINCOURT T, REGAUDIE V.; EDF DER; Moret sur Loing, France
Characteristics of long term deterioration of XLPE cable and its diagnostic techniques in Japan
OHATA K.; Tokyo Electric; Tokio, Japan
FURUHATA H.; Chubu Electric; Nagoya, Japan
NAKAGAWA S.; Kansai Electric Co.; Osaka, Japan
SAKAMOTO T,; Mitsubishi Cable; Kumagaya, Japan
EBINUMA Y.; Showa Electric; Sagamihara, Japan
YOSHIDA T.; Furukawa Electric; Tokyo, Japan
MV Cable maintenance, practices and results
VAN SCHAIK N., BOONE W., HETZEL E.; KEMA; Arnhem, The Netherlands
GROTENHUIS B.J.; REMU; Utrecht, The Netherlands
Discharge current method. A test procedure for plastic-insulated medium-voltage cables
MUHR M., WOSCHITZ R.; Institute of High Voltage Engineering; Graz, Austria
The return voltage method, a diagnostic tool to assess water tree damage in PE- and XLPE cables, and the experiences from the method in Romania
KAMENKA D.; Hagenuk KMT,; Radeburg, Germany
PISPIRIS C.S.; ICEMENERG; Bucarest, Romania
Study on diagnostic method for water treed XLPE cable by loss current measurement
YAGI Y., TANAKA H. MUTO H. KIMURA H.; The Furukawa Electric Co. Ltd.; Chiba. Japan
Behavior and diagnostic techniques of initial defects on XLPE insulated cable systems
NAKAGAWA T.; Hitachi Cable Ltd; Tokyo, Japan
OHATA K.; Tokyo Electric Power Co.,; Tokyo, Japan
NAKAGAWA S.; Kansai Electric Power Co; Osaka, Japan
FURUHATA H.; Chubu Electric Power Co.,; Nagoya, Japan
ASAI S.; Sumitomo Electric Industries Ltd.,; Osaka, Japan
YAMANOUCHI H.; Fujikura Ltd.; Tokyo, Japan
Medium voltage cable testing by partial discharge location: A comparative discussion of field generated diagnostic results
MASHIKIAN Matthew S., HAN C, ZIEGLER S.; IMCORPTtm; Storrs, USA
Partial discharge, predictive cable testing experience and lessons learned
REDER W.; Ultra Power Technologies lnc.,; Minneapolis, USA
On-Line partial discharge detection and classification by pattern recognition on HV terminations
PULTRUM E., ROSS R.; KEMA; Arnhem, The Netherlands
GULSKI Edward; Delft University of Technology; Delft, The Netherlands
VAN RIET M.J.M.; Nuon Technisch Bedrijf; Duiven, The Netherlands
On-site partial discharge diagnosis and monitoring on HV power cables
GROSS D.W.; Power Diagnostix Systems GmbH; Aachen, Germany
Installation of 500 kV DC PPLP-insulated oil-filled submarine cable
INOUE T.; The Kansai Electric Power Co. Lnc; Osaka, Japan
MITANI M.; Sumitomo Electric Industries Ltd.,; Osaka, Japan
SHIIGETOSHI L.; Fujikura Ltd; Tokyo, Japan
MAEKAWA Y.; Electric Power Development Co. Ltd; Tokyo, Japan
FUJII O.; The Furukawa Electric Co. Ltd; Tokyo, Japan
SHIMADA M.; Hitachi Cable Ltd; Ibaraki, Japan
Rectification of submarine cables of Croatian 110 kV cross-island connection
SAINA Bruno; The Croatian National Electricity; Opatija, Croatia
TOMASOVIC L, MOSER J.; The Croatian National Electricity; Zagreb, Croatia
Development of XLPE cable under DC voltage
SATORU M., TANAKAT., MUTO H.; The Furukawa Electric Co. Ltd.,; Chiba, Japan
TERASHIMA K., WATANABE C.; Electric Power Development; Tokyo, Japan
Experience in service of submarine power cables 150 kV in Bali strait
SINISUKA N.I.; Bandung Institut Teknology Bandung (lTB),; Bandung, Indonesia
PRIYADI B. H.,; PT PLN (PERSERO),; Jakarta, Indonesia
The development of an extruded HVDC cable system and its first application in the Gotland HVDC Iight project
BYGGETH M., JOHANNESSON K.; ABB High Voltage Cables; Karlskrona, Sweden
LILJEGREN C.; GEAB (Gotlands Energiverk AB),; Visby, Sweden
PALMQVIST L.; ABB Kabeldon AB; Alingsas, Sweden
AXELSSON U.; Vattenfall; Stockholm, Sweden
JONSSON J., TORNKVIST C.; ABB Corporate Research; Vasteras. Sweden
Research and development of DC XLPE cable and associated factory joint
TERASHIMA K., ASANO M.; Electric Power Development Co. Ltd.,; Tokyo, Japan
WATANABE K, YOSHIDA M., KON H.; Fujikura Ltd.,; Chiba, Japan
The stability of mass-impregnated paper AC cables operated at DC voltage
MORSHUIS Peter H. F., ROEFS R.J., SMIT J.J.; University of Technology; Delft, The Netherlands
CONTIN A.; DEEI University of Trieste; Italy
MONTANARI Gian Carlo; University of Bologna; Italy
Field distribution in HVDC cables : dependence on insulating materials (see also C2.13.)
ALADENIZE B., COELHO R., ASSIER J.C; Alcatel CRC; Marcoussis, France
JANAH H., MIREBEAU Pierre; Alcatel Cable; Calais, France
A new method for the measurement of power cables AC resistance
BOURGEAT X.; EDF DER; Moret sur Loing, France
SANTANA José., FUSTIER Abel., DEJEAN Piere-Marcel; Câbles Pirelli; France
Real time thermal of HV cables
PRAGNELL B.; Pirelli Cables Ltd.,; Eastleigh, United Kingdom
GASPARI R.; Pirelli Cavi S.p.A.; ItaN
LARSEN S.T.; The National Grid Company; United kingdom
Conductor temperature estimation of underground cables
CARAMIA P., LOSI A., Russor\/i.; Universita' degli Studi di Cassino; Cassino,ltaly
Cable temperature monitoring
BALOG G., NERBY T.I., KALDHUSSAETER E.; Alcatel Kabel Norge; Halden, Norway
Calculation method of power cables AC resistance with individually insulated strands
ARGAUT P., DAURELLE J.Y.; SAGEM SA; Montereau, France
Optimising high voltage underground cable links
LE PEURIAN S; EDF DER; Moret sur Loing, France
JUNG M.; EDF Production Transport; Courbevoie, France
Influence of admittance asymmetry of underground cables in compensated systems behaviour
RUZ F.; Universidad de Murcia; Spain
GARCIA M.; Universidad Politecnica de Valencia; Spain
Sheath overvoltages affecting specially bonded underground links during single-phase faults
VO VAN HUY H., DORISON E.; EDF DER; Moret sur Loing, France
About disturbances in power systems at the transients due to switching operations of cable dynamics
TUSALIU P., TUSALIU V, TUSALIU D., TUSALIU M.; University of Craiova; Romania
Electrical transient conditions of buried cable systems.
ARGAUT P, DAURELLE J.Y.; SAGEM SA; Montereau, France
Integration of underground cables in an overhead line
TASSY J.; EDF Production Transport; Courbevoie, France
BOURGEAT X.; EDF DER; Moret sur Loing, France
Switching overvoltages in complex networks
IOAN S., HURDUBETIU S., ANGHELUTA B.; Bucharest Politehnica University; Bucharest, Romania
Type testing of cables and accessories
BERLIJN S.M., GRUNTJES R.J.B., ROELOFS G.P.T; Kema Nederland; Arnhem, The Netherlands
Improved diagnosis of MV paper-insulated cables using signal analysis
VILLEFRANCE R.; NESA A/S; Gentofte, Denmark
HOLBOELL J.T., SORENSEN J.Aa.; Technical University of Denmark; Denmark
JORGENSEN H.J.; DEFU; Denmark
Influence of test voltage shape and frequency on PD-activity of defects in XLPE insulated medium voltage cables
PEPPER D., KALKNER W.; Technical University of Berlin; Germany
Mie Scattering characteristics of defects in cross-linked polyethylene insulation of power cables
ZHAO H., TU D.; Xian Jiaotong University; Xi'an, China
LU Y, LIU L.; Harbin University of Science & Technolog; Harbin, China
Practical experience in partial discharge site location of XLPE cables using a digital discharge detector
FAWCETT R., HILDER D.; Robinson Instruments; USA
LARZELERE B.; ECI; NY, USA
Partial discharge measurement in transmission-class cable terminations
AHMED N., SRINIVAS N.; Detroit Edison Company; Detroit, USA
A comparative experimental investigation on various after laying test methods employable to 22.9 kV CN/CV distribution power cables
KOO J.Y., LEE J.S.; Han Yang University; KyungGi-Do, Korea
KIM J.T.; Daejin University; KyungGi-Do, Korea
Electrical and acoustical PD on-site diagnostics of service aged medium voltage power cables
WESTER F.J.; Energie Noord West; Alkmaar, The Netherlands
GULSKI Edward, SMIT J.J.; Delft University of Technology; Delft, The Netherlands
The estimation of electrical performance from highly censored test data
HAMPTON R.N.; BICC Cables Ltd; Erith, UK
WALTON M.D.; BICC Cables Corp; USA
BERNSTEIN B.; EPRI; USA
Numerical model for radial symmetric sensors for partial discharge detection on XLPE insulated high voltage cables
HEINRICH R., KALKNER W.; Technical University of Berlin; Germany
JOBAVA R., GHEONJIAN A.; Tbilisi State University; Tbilisi, Georgia
Time and frequency domain based non-destructive diagnosis in comparison to destructive diagnosis of service-aged PE/XLPE insulated cables
KUSCHEL M., KALKNER W.; Technical University of Berlin; Germany
Diagnosis on power cables for determination of remaining lifetime : Experiences with oscillating wave test
PFEIFFER W., TREDE T; Technical University of Darmstadt; Germany
Condition assessment of medium voltage power cables in industrial environments by means of VLF techniques
DE NIGRIS M., VERCELOTTI U., ZAGLIANI F.; CESI; Milano, Italy
Study of AC charging ability of XLPE insulating for power cable
AGNEL S., TOUREILLE A.; Laboratoire d'Électrotechnique de Montpellier,; France
PLATBROOD G., GEERTS G.; Laborelec; Linkebeek, Belgium
Space charge in AC-poled XLPE for HV cables
NOTINGHER P jr., TOUREILLE Alain; Laboratoire d'Électrotechnique; Montpellier, France
SANTANA José.; Câbles Pirelli; Sens, France
ALBERTINI M.; Pirelli Cavi e Sistemi; Milano, Italy
Life modelling of AC cable insulation based on space-charge inference
MAZZANTI G., MONTANARI G.C.; University of Bologna; Italy
DISSADO Leonard A.; Leicester University; United Kingdom
Cross-linked polyethylene materials for DC power cables
BOSTROM J.O., CAMPUS A, NILSSON U.H.; Borealis AB; Stenungsund, Sweden
CARTENSEN P., GUSTAFSSON A.; ABB Corporate Research; vasteras. Sweden
FARKAS A. Andras, JOHANNESSON K.,; ABB High Voltage Cables AB; Karlskrona, Sweden
Field distribution in HVDC cables : dependence on insulating materials (see also B7.8.)
ALADENIZE B., COELHO R., ASSIER J.C.; Alcatel CRC; Marcoussis, France
JANAH H., MIREBEAU Pierre; Alcatel Cable; Calais, France
Elastic-wave methods for the measurement of space charge distributions : evolution and perspectives
PARIS O., lEWINER J.; ESPCI, laboratoire d'Électricité Générale; Paris, France
DITCHI T., HOlE S.; Université P. & M. Curie, laboratoire des Instruments et Systèmes; Paris, France
Calculation of charge density and electric stress in XLPE compounds
DAVIES AE., CHEN G., WU X.; University of Southampton; United Kingdom
HAMPTON R.N.; BICC Cables Ltd; Erith, UK
SUTTON Simon, SWINGLER S.G.; National Grid Company; United Kingdom
Space charge measurement in dispersive dielectrics
DAVIES AE., CHEN G.; University of Southampton; United Kingdom
VAZQUEZ A.; Universitat of Politecnica Catalunya; Spain
Investigation of the effects of temperature variations on space charge formation in polyethylene
KHALIL M.S.; College of Engineering, Sultan Qabos University; Muscat, Sultanate of Oman
CHERIFI A, REBOUL J.M., CARIN R.; Université de Caen Basse-Normandie; Caen, France
The effect of different screens and conditioning on the charge trap sites in XLPE cables
BETTERIDGE S., NOYES R.P., VAIL J.; BICC Cables Ltd; Wrexham, United Kingdom
On the derivation of quantities from space charge measurements for the characterization of cable insulation performance
FABIANI Davide, MONTANARI Gian Carlo; DIE, University of Bologna; Italy
ALBERTINI M., PEREGO G.; Pirelli Cavi e Sistemi; Italy
Correlation between the space charges and the discharge current on a 20 kV DC cables (XLPE)
FANJEAU O., TRUONG V.H., MALEC D.; Laboratoire de Génie Électrique; Toulouse, France
Towards an understanding of space charges trapping in cable polyethylene
MEUNIER M., QUIRKE N.; Imperial College; London, United Kingdom
BINESTI D.; EDF DER; Moret sur Loing, France
Correlation between conduction and space charge studies on laminar dielectrics under DC stress
AL-SAOUR, CHANG F., HAMPTON R.N., HOBDELL SB.,; BICC Cables Ltd; Erith, UK
Theoretical and experimental study of space charge under DC polarisation up to breakdown in power cable insulator
ZEBOUCHI N.; ABB Corporate Research OY; Vasteras, Finland
THE GIAM H.; Laboratoire de Génie Électrique; Toulouse, France
Nature of carrier traps in polyethylene and possible implication in aging process
AUGE J.L., MARY D., TEYSSEDRE G., LAURENT C.; Laboratoire de Génie Électrique; Toulouse, France
BERDALA Jacques; Câbles Pirelli; Sens, France
CLAVREUL R.; EDF DER; Moret sur Loing, France
Quick method for direct measurements of all important parameters concerning water transport and diffusion in XLPE cables
URSIN C., FICH PERDERSEN T.; CU Test & Development Ltd.,; Copenhagen, Denmark
Water treeing detection in 15 kV cables using the thermal step method
CASTELLON J., MALRIEU S.; Advanced Metrology for Electrical Engineering; Montpellier, France
TOUREILLE Alain; Laboratoire d'Électrotechnique de Montpellier; France
Product and process development of a peroxide injection cable with enhanced resistance in wet operating conditions
ROVIRA J., VILLAGRASA F., MARTINEZ J.D.; BICC General Cables; Barcelona, Spain
MATEY Gabriel, LABBE D.; Products & Marketing Ltd.,; Geneva, Switzerland
Development and application of a sample test for water treeing in medium voltage cables
LE POIDEVIN G., MCINTOSCH L.A, NAYBOUR R.D.; EA Technology; Chester, United Kingdom
Water treeing in polyethylene insulation of power cables
KANISKIN V.A, POLONSKY YA,; St. Petersburg State Technical University; St. Petersburg, Russia
Fourth generation dielectric enhancement technology
JENKINS K.A, BERTINI G.J.; UtilX Corporation; Kent, WA, USA
Polymer modified XLPE as insulation in power cables
NILSSON U.H., CAMPUS A.; Borealis AB; Stenungsund, Sweden
MONTANARI Gian Carlo; University of Bologna; Italy
Estimation of thermal loss of life of MV/LV cables taking into account moisture migration
CARAMIA P., LOSI A, RUSSO A., VERDE P.; University of Cassino; Italy
Decomposition of high pressure SF6 and SF6-N2 (10-90) mixtures submitted to negative polarity corona discharges. Effect of the percentage of water added
VIAL L., CASANOVAS A.M., COLL L, CASANOVAS J.; Université Paul Sabatier; CPAT, Toulouse, France
CLAVREUL R.; EDF DER; Moret sur Loing, France
Antioxidant concentration distribution measurement in XLPE cable insulation by PIXE Analysis, FTIR and UV spectroscopy
PARPAL J.L., GUDDEMI C.; Hydra-Québec (lREQ); Québec, Canada
HINRICHSEN; Université de Montréal; Canada
Characterization of the dynamical structure of cable insulation
MENEGOTTO J., LACABANNE C.; Laboratoire Physique des Polymères; Toulouse, France
MAYOUX C.; Laboratoire de Génie Electrique; Toulouse, France
PLATBROOD G.; Laborelec; Linkebeek, Belgium
Interface behaviour in HV and EHV accessories
GAHUNGU François, MIREBEAU Pierre; Alcatel Cable; Calais, France
ASSIER JC, GARROS B., ALADENIZE B., COELHO R.; Alcatel CRC; Marcoussis, France
CARDINAELS J,; Alcatel Euromold; Erembodegem Belgium
Low density polyethylene microstructure observation under AC or DC high stress
BERTIN C, GUASTAVINO J., MAYOUX C, MARTINEZ-VEGA JJ.; Laboratoire de GénieÉlectrique; Toulouse, France
CAMPUS A.; Borealis AB; Stenungsund, Sweden
Varistor composites for cable applications
RIEUX N. PERRIN S.; Alcatel Corporate Research Center; Marcoussis, France
PARASIE Y.; Alcatel Cable; Paris, France
Electroluminescence in XLPE due to impulses superimposed on AC voltage
BAMJI S.S. BULINSKI A.T.; National Research Council of Canada; Ontario. Canada
TOHYAMA K.; Numazu College of Tech.,; Numazu, Japan
The study of on-line relaxation effect on internal mechanical stresses and dielectric strength of HV cable insulation
SHUVALOV Mikhail, OBRAZTSOV Y. OVSIENKO V., KRUCHKOV A.; AII-Russian Scientific Research& Development Cable lnstitute; Moscow, Russia
HUOTARI P.; Nextram Technologies; Vantaa, Finland
Optimization of cable terminations equipped with non-linear stress control tubes
PETRARCA C.; Università di Napoli "Frederico II"; Napoli, Italy
EGIZIANO L. TUCCI V.; Università di Salerno; Fisciano, Italy
VITELLI M.; Seconda Università di Napoli; Aversa, Italy
Comparison between Lewis and Crine models for the electrical aging of extruded cables
CRINE Jean Pierre; Technology Consultant; Brossard, Canada
Influence of a solid organic insulator on the arc decomposition and high energy spark decomposition of SF6 and SF6-N2 (10-90) mixtures
COLL I., CASANOVAS A.M ., VIAL L., GLEIZES A., CASANOVAS J.; Université Paul Sabatier; CPAT, Toulouse, France
CLAVREUL R.; EDF DER; Moret sur Loing, France
An analysis of the interfacial region of HV cables using electrostatic force microscopy
BETTERIDGE S.; BICC Cables Ltd; Wrexham, United Kingdom
LEWIS lJ., LLEWELLYN J.P.; SEECS University of Walesl Banqor; United Kingdom
HAMPTON R.N.; BICC Cables Ltd; Erith, UK
High performance conductor shields for HV/EHV solid dielectric power cables
REID C. G.; Union Carbide Corporation; Somerset, NJ, USA
New potentialities of conducting polymers for cables
COTTEVIEILLE D., CARIOU F; Alcatel Corporate Research Center; Marcoussis, France
MIREBEAU Pierre; Alcatel Cable; Calais, France
DEMAY J.N.; Alcatel Cable; Lyon, France
PARASIE Y; Alcatel Cable; Paris, France
Application of new ethylene elastomers in wire and cable
HEMPHILL J.,; Dupont Dow Elastomers; Freeport, USA
XLPE insulation under thermomechanical stress - a model-like explanation of the behaviour of an intelligent material
GITSCHNER H.W.; Felten &Guilleaume Kabelwerke GmbH; Cologne, Germany
Evaluation of a new EPDM insulation compound for HV cable accessories
GUSTAFSSON A.; ABB Kabeldon AB; Alingsas, Sweden
PALMQVIST L.; ABB Corporate Research; Vàsteras. Sweden
Novel ambient curing and scorch retardant system for moisture crosslinkable polyethylene
FAGRELL O.; Borealis AB; Stenungsund, Sweden
The development of a quality control technique to quantify the cleanliness of semiconductive materials
AKERMARK G., CAMPUS A., NILSSON U.H.; Borealis AB; Stenungsund, Sweden
MULLER K.B.; ABB Kabel und Draht GmbH; Mannheim, Germany
STUCKI F.; ABB Corporate Research; Baden-Dâttwil, Switzerland
High performance HVDC polymer cable
TANAKA T, KUNII K.; Tokyo Electric Power Company; Yokohama, Japan
NAKATSUKA T, MIYATA H., TAKAHASHI T.; Fujikura Ltd; Tokyo, Japan
Power drive rollers pulling improvements
HERBRETEAU A.; Omnium Technique du Câble; France
THEVENON Henri; Consultant; France
Mechanical laying of HDPE ducts in rural area
MARTY L., LE CORGUILLE J.L.; RTE France; France
2003 - A10-3
Restraining the migration of HV cables in duct
TARNOWSKI J., IORDANESCU; Institut de Recherches d’Hydro-Québec; Canada
AWAD R.; Hydro-Québec; Canada
Construction of 275 kV underground transmission line composed of continuous 2,500m long cable
HAYASHI N., SAITOU H., SHIMOHIRO D., KAWAI T.; Chubu Electric Power Co. Inc.; Nagoya, Japan
KAWAI T.; Chubu Electric Power Co. Inc.; Japan
ISHII N.; The Furukawa Electric Co. Ltd; Tokyo, Japan
HIRASAWA T.; VISCAS Corporation; Tokyo, Japan
WATANABE M., NAKAGAWA T; J-Power Systems Corp.; Japan
Innovative installation method using water as a carrying fluid do install power cables in-pre lubricated ducts in trenches of reduced dimensions
TRICHARD C.; Netconcept; France
BLANC C.; Novoplastic; France
G. PLUMETTAZ; Plumettaz SA; Switzerland
Increasing cable drum lengths
LESUR Frédéric; EDF R&D; Moret-sur-Loing, France
ARGAUT P., SACHER J.; SAGEM; Montereau, France
Design and commissioning test of a 230- kV cross-linked polyethylene insulated cable system
KHAJAVI M.B.; Los Angeles Department of Water And Power; USA
ZENGER Walter; EPRI; USA
Undergrounding the first 400 kV transmission line in Spain using 2 500 mm2 XLPE cables in a ventilated tunnel: the Madrid Barajas airport project
GRANADINO R., PORTILLO M.; Red Electrica de España; Spain
PLANAS J.; Pirelli Cables y Sistemas; Spain
SCHELL F.; ABB Energiekabel; Germany
Pre-selection of cable type and cable manufacturers for the MetroGrid project in Sydney Australia
JONES S.J.; Transgrid; Australia
BUCEA G.; Transgrid; Australia
MAYER H.A.; Engineering Consultant; Australia
Utility experience in establishing technical standards specification for powers cable projects: A case study from Gulf area
Dr. EL-HOSSEINY TAHA EL-SHIRBEENY; Abu Dhabi Water and Electricity Authority; United Arab Emirates
Development of 275 kV XLPE cable with aluminium laminated tape and radial moisture Barrier
UMEDA K., MATSUURA K.; The Kansai Electric Power Co, Inc.; Japan
WATANABE M., SAKAGUCHI Y., OHIMO T.; J-Power Systems Corp.; Japan
Real time monitoring of power cables by fibre optic technologies tests, applications and outlook
LUTON M-H.; Sagem; Montereau, France
ANDERS G.J., BRAUN J.M., FUJIMOTO N., RIZZETTO S.; Kinectrics Inc.; Canada
DOWNES J.A.; Sensa; UK
Qualification of a highly electrically and mechanically stressed AC cable system
ERICSSON A., THUNWALL Bo.; ABB Power Technologies; Sweden
GUSTAFSSON A., SVAHN J.; ABB Power Technologies; Sweden
120 kV cable installation at Beauharnois power station
CHOQUETTE M.; Hydro-Québec; Canada
CANAAN A.; Pirelli; Canada
A new generation of optimised 120 kV cable systems at Hydro-Quebec
ROYER Christian, AWAD Ray, BOYER P., CHOQUETTE M., GIGNAC R., PARPAL Jean-Luc; Hydro-Québec; Canada
CANAAN A.; Pirelli; Canada
Prequalification test of 400 kV XLPE cable system
KO E.G., CHOI S.G., JEON, S.I., YANG J.S., LEE I.H., PARK W.K.; LG Cable Ltd; Korea
WOUTER J.W.M. SLOOT, PULTRUM E.; KEMA; Arnhem, The Netherlands
Large projects of EHV underground cable systems
BJORLOW-LARSEN Kjell; Nexans;
DEL BRENNA M.; Pirelli; Italy
KAUMANNS Johannes; ABB;
MEIER R.; Brugg Kabel AG; Switzerland
KIRCHNER M.; NKT Cables;
ARGAUT P.; Sagem; France
The development of an ultrasound quality monitoring process for the manufacture of enhanced reliability HV and EHV XLPE cables
SMITH C.; IPEC Ltd; United Kingdom
GALLOWAY S., GREGORY B., LLOYD S., NOTMAN D.; Cable ConsultingInternational Ltd; United Kingdom
New generation of GIL. Characteristics and applications
PONCHON Ph., BUES M., GIRODET A., LORAY F.; Alstom; France
Experience with 2nd generation gas-insulated transmission lines GIL
KOCH H.; Siemens AG; Germany
Very fast front overvoltage computation in GIL due to switching operations with disconnectors in GIS
CRISTESCU D.; Politehnica University of Bucharest; Romania
VASILIU Z.H., MICU C.; SC Electrica SA;
NICOARA B.; Eduperco Centre, Politehnica University of Bucharest; Romania
Development project on HTS Cables
COEVOET M.; EDF R&D; France
LADIE P.; Pirelli Cavi e Systemi Energia; Italy
Volume effect of partial discharge inception characteristics in high temperature superconducting cable
HAYAKAWA N., KOBAYASHI T., HAZEYAMA M., OKUBO H.; Nagoya University; Japan
TAKAHASHI T.; CRIEPI; Japan
YASUDA K.; Super-GM; Japan
V-t characteristics at PD inception for LN2 impregnated HTS cable insulation system
HAYAKAWA N., HAZEYAMA M., KOBAYASHI T., OKUBO H.; Nagoya University; Japan
TAKAHASHI T.,; CRIEPI; Japan
YASUDA K.,; Super-GM; Japan
Critical issues for the HV & EHV XLPE cables of today and tomorrow
CAMPUS A., HAMPTON R.N., SMEDBERG A., WALD D.; Borealis AB; Sweden
BOSTROM J.O.; Borealis Compounds LCC; USA
LENNARTSON H.; Borouge Pty; Hong kong Ltd.
400 kV cables for bulk power transmission systems
DORISON Eric; EDF R&D; France
MAUGAIN Yves; RTE; France
New 400 kV underground cable system project in Jutland (Denmark)
MIKKELSEN S.D.; Eltra; Denmark
ARGAUT P.; Sagem; France
Development and prequalification of large conductor VHV cable systems
MOREAU L., GAHUNGU F., DUBOIS D., SY D., MIREBEAU Pierre; Nexans; France
BC Hydro’s experience with a novel on-line monitoring system used on a 242 kV PPLP insulated cable system
CHERUKUPALLI S., KOJIMA T., MACPHAIL A., CHORE R., STRUYK E.; BC Hydro; Canada
KUMADA Y., NAKAJIMA T.; VISCAS Corporation; Japan
Installation of a 220 kV XLPE cable in a deep shaft for a hydroelectric power plant
A. MARINI; Enel Produzione; Italy
BISLERI Cesare, ZACCONE Ernesto; Pirelli Cavi e Sistemi Energia SpA; Italy
Development of factory-expanded cold-shrinkable joint for EHV XLPE cables
KOBAYASHI S., MUTO D., TANAKA S., LIZUKA H.; The Furukawa Electric Co. Ltd; Japan
NIINOBE Hiroshi; Fujikura Ltd; Japan
SUETSUGU M.; VISCAS Corporation; Japan
Space charge distribution in two-layer dielectrics
LIANG L., XIA W., DEMIN T.; Xi’an Jiaotong University; Xi’an, China
Development of cold shrinkable joints for 110~230 kV XLPE cable
NAKAMURA S., KUWAKI A., HAYASHI K., MIKAMI M.; Exsym Corporation; Japan
Completion of prefabricated joint for 500 kV XLPE cable
KOBASHI K.; The Kansai Electric Power Co. Inc.; Japan
BAN S.; J-Power Systems Corp.; Japan
KANAOKA M.; J-Power Systems Corp.; Japan
YONEMURA T.; The Furukawa Electric Co. Ltd; Japan
NIINOBE Hiroshi; Fujikura Ltd.; Japan
Test methods for SiR-accessories used in high voltage cables up to 400 kV
WEISSENBERG Werner; Brugg Kabel AG; Switzerland
KUSCHEL M.; SIEMENS AG; Germany
Super compact rubber block joint with high dielectric constant layer
NIINOBE Hiroshi, KON H., TAKAHASHI T., WATANABE A., AKIMOTO S.; Fujikura Ltd.; Japan
UMEDA S.; VISCAS Corporation; Japan
IZUKA H.; The Furukawa Electric Co. Ltd.; Japan
Anti-explosion protection for HV porcelain & composite terminations
GAHUNGU François; Nexans; France
CARDINAELS J.; Nexans Euromold; Belgium
STREIT P., ROLLIER D.; Nexans Switerland Cossonay; Switzerland
Microvaristor based field grading elements for HV terminations
GRAMESPACHER H.; ABB Switzerland Ltd.; Swtizerland
DONZEL L., CHRISTEN T., GREUTER F.; ABB Switzerland; Switzerland
DONZEL L., CHRISTEN T., GREUTER F.; ABB Switzerland; Switzerland
New dry outdoor terminations for HV extruded cables
DEJEAN Pierre-Marcel; Pirelli Câbles & Systèmes; France
GOEHLICH L.; Technical University Berlin; Germany
QUAGGIA Dario, PARMIGIANI Bruno; Pirelli Cavi e Sistemi Energia; Italy
Plug-in type connection techniques using HV-connex on encapsulated components in high-voltage equipment up to Um = 245 kV
DEISTER P.F., SCHUSTER M.; Pfisterer Kontaktsysteme; Germany
Subsea XLPE cables
HAMPTON R.N., RYDIN C., SMEDBERG A.; Borealis AB; Sweden
Development of 500 kV DC XLPE cable system and its pre-qualification test
MARUYAMA S., ISHII N.; The Furukawa Electric Co. Ltd; Japan
YAMANAKA T., KIMURA T.; Electric Power Development Co. Ltd; Japan
TANAKA H.; VISCAS Corporation; Japan
Development of DC extruded cables and factory joints in Japan
YAMANAKA T., KIMURA T.; Electric Power Development Co. Ltd; Japan
MURATA Y., HIROTA H.; J-Power Systems Corp.; Japan
SHIGETOSHI I.; Fujikura Ltd.; Japan
MARUYAMA S.; The Furukawa Electric Corp.; Japan
The Murray Link project – the first commercial 150 kV extruded HVDC cable system
WORZYK T., JEROENSE M.; ABB Power Technologies; Sweden
FARR M.; TransEnergie Australia; Australia
SÖRQVIST T.; ABB Power Technologies; Sweden
HVDC extruded cables: testing of cable systems aiming at VSC or LCC applications
JANAH H., MATALLANA J., SY D., MIREBEAU Pierre; Nexans; France
Energy transmission on long three core/three foil XLPE power cables
BALOG G.E., EVENSET G.; Nexans Norway AS; Norway
RUDOLFSEN F.; Norconsult AS; Norway
Transmission power cables partial discharge detection at damped AC voltages
GULSKI Edward, WESTER F.J., SMIT J.J.; Delft University of Technology; Delft, The Netherlands
GROOT E.R.S., WESTER Ph.; Nuon; The Netherlands
SEITZ Paul P.; Seitz Instruments AG; Switzerland
Partial discharge diagnostics as part of CMB on MV power cables: Yes or No ?
VAN SCHAIK N., STEENNIS E.F., ROSS R.; Kema T&D Testing Services; The Netherlands
KRUITHOF Marko; ENECO Energie; The Netherlands
The Cenelec long term test for XLPE MV cables – Everything new and different ?
MEURER D., STÜRMER M.; Nexans Deutschland GmbH & Co. KG; Germany
On-site AC testing and PD measurement of 345 kV/2500 mm2 XLPE cable systems for bulk power transmission
KAUMANNS Johannes, PLIETH E.; ABB Energiekabel GmbH; Germany
PLATH Ronald; IPH, High Voltage Lab.; Germany
Experience with after laying test
PULTRUM E., VERHOEVEN S.A.M., VAN SCHAIK N.; Kema High Voltage Laboratory; The Netherlands
Results of after-laying tests of 275 kV XLPE cable line
KOBAYASHI S.I., MORIMOTO N., KAWABE T., SHINODA A., SHIMOHIRO D.,KAWAI T.; Chubu Electric Power Co. Inc.; Japan
Calculation of thermal ratings of cable systems using generalized matrix method
HIRANANDANI A.; DTE Energy; USA
Effect of power cable installation on current rating, magnetic fields and reliability
de WILD F.H., MEIJER G.J., ROSS R.; KEMA-TDT; The Netherlands
Ampacity program of IEC 60287 and JCS 168 E suitable for KEPCO
JEONG S.H., KIM D.K., CHOI S.B.; KERI; Korea
YOON H.H., TACK E.G.; Korea Electric Power Corporation (KEPCO); Korea
Cable crossings
DORISON Eric; EDF R&D; France
Determination of cable dynamic rating from distributed temperature sensing and hotspot temperature analysis
SU Qi, LI Hong-jie, TAN Kee Choon; Singapore PowerGrid; Singapore
Cable rating using a computer analogue
LYALL J.S.; School of Electrical and Electronic Systems Engineering; Australia
New MV cables used in France and improvements in laying techniques
DAVID J.M., MOREAU C.; EDF R&D; France
TAMBRUN R., ODDI M.; EDF DEGS DRE-MER; France
Investigations of medium voltage polymeric cables aimed at a rationalised European standard
DAVID J.M.; EDF R&D; Moret-sur-Loing, France
PAPADOPULOS M.S.; The Electricity Association; United Kingdom
FARA A.; ENEL DDR-USA-UNI; Italy
MARCET F.; Iberdrola; Spain
BANKS V.A.A.; Pirelli Cables; United Kingdom
CENSIER B.; Pirelli; France
DIEFENBACH I.; RWE Eurotest GmbH; Germany
FONTANA M.; Pirelli Cavi; Italy
FANGAIN J.; Nexans France; France
Measurement of the rigidity of polymeric cables
JORGENSEN H.J.; DEFU a.m.b.a.; Denmark
BENJAMINSEN J.T.; SINTEF Energy Research; Norway
NIELSEN N.H.; NKT Cables A/S; Denmark
LARSEN P.B., RYEN A.; Nexans Norway AS; Norway
ENGER S.; Draka Norsk Kabel; Norway
Influence of some selected service conditions on properties of XLPE applied in insulated or covered overheads conductors
JANISZEWSKI S., RAKOWSKA A.; Poznan University of Technology; Poland
New approach for MV underground connection
CHARLES F., PETRUS R., ARGAUT P.; Sagem S.A.; France
20 years of experience with copolymer power cable insulation
CAMPUS A.; Borealis Polymers NV; Switzerland
ULRICH M.; ; Germany
Laminate sheath power cable insulated with XLPE for flame retardant applications
BOW Kenneth E.; The Dow Chemical Company; USA
Fire retardant mechanism intumescent EVA compositions
CAMINO G. & RIVA A.; Politechnico di Torino; Italy
AMIGOUËT P., BRAS PEREIRA P.; Nexans-NRC; France
Compounding of flame retarded materials for the wire and cable industry
RICHARDSON Colin G.; Coperion Buss AG; Switzerland
Study on low-smoke low-halogen and flame retardant PVC sheath composite
XIAOGANG S., XIJING C., YONGHUA Z., XIUFENG L.; Shandong Luneng Cable CO Ltd; China
Advanced SZ-stranding technology for flexible conductors
MARIK J., ALTMANN E.; Rosendahl; Austria
Special MV cable for long stator winding application Transrapid Shanghai
BUETHE H., LE DREN S., STEINBRINK D., ZAMZOW P. E.; Nexans Deutschland; Germany
Decision support for condition assessment of power cables
GULSKI Edward, WESTER F.J., SMIT J.J.; Delft University of Technology; Delft, The Netherlands
DE FRIES F.; Nuon; The Netherlands
Condition assessment of distribution PILC cables from electrical, chemical and dielectric measurements
BUCHHOLZ V., COLWELL M.; Powertech Labs Inc.; Canada
CHERUKUPALLI S.; BC Hydro; Canada
CRINE Jean Pierre; Consultant; Canada
KEEFE R.; EPRI; USA
Influence of corroded conductors on the performance of medium voltage extruded cables
PELISSOU Serge; Hydro Québec (IREQ); Canada
COTÉ J., SAVAGE R., ST ANTOINE S.; Hydro-Québec (Distribution); Canada
A multidiscipline 35 kV cable failure investigation
ORTON H., FURST G. & BATHO A.; Orton Consulting Engineers International Ltd; Canada
RAO A.; Powertech Labs; Canada
DE SALVIDAR C.; Conductores Monterrey; Mexico
GOMES MORANTE M.; Was with Hylsa; Mexico
Diagnostics and maintenance of high-pressure fluid-filled paper cable
LINOIS P., ROBINOT G., ROIZARD T.; RTE; France
MEURICE D., WELSCH E.; EDF R&D; France
Effects of sea salt sediment on 110 kV cable stations on the Croatian Adriatic coast
ALIJINOVIC S.; HEP Transmition; Croatia
Environmental considerations for end of life disposal of cables
HELMESJÖ B.; Borealis; Sweden
HAGSTRÖM B.; IFP Research; Sweden
Scraps recycling
BARIOZ C.; Nexans NRC; France
COSTERG T.; RIPS Nexans; France
Innovative ways to build underground power cables and communication networks in strategic partnerships with utility pipe owners
JEYAPALAN Jey K.; Dr Jeyapalan & Associates , LLC; USA
Environment conscious design of VHV transmission links by cable systems
MIREBEAU Pierre; Nexans France; France
ARGAUT P.; Sagem; France
DEJEAN Pierre-Marcel; Cables Pirelli; France
New stabilizer concepts for polyethylene used in power cable applications
STRICKER F., KOLB M.; CIBA Specialty Chemicals; Switzerland
The continuing evolution of semiconductive materials for power cable applications
LINDBOM L., NILSSON U., HAMPTON R. N., BROMAN C.,.EKLIND H.,NYLANDER P.; Borealis; Sweden
New XLPE insulation for HV and EHV cables
CARONIA P.J., COGEN J.M.; Dow Chemical GmbH; USA
KJELLQVIST J.B.L., AARTS M.W.A.M.; Dow Europe GmbH; Switzerland
New flexible TR-XLPE insulation for medium voltage power cables
GROSS L.H., CARONIA P.J.; Dow Chemical Company; USA
KJELLQVIST J.B.L.; Dow Europe GmbH; Switzerland
Study on properties of rubber improved with nanomaterial used in cable
MAN X.,LIU Y. BINGLI Y., XIAOLONG C.; Xi’an Jiaotong University; China
Survey of space charge evolution in high voltage cables submitted to AC voltage as part of the Artemis project
NOTINGHER P. jr., TOUREILLE Alain, AGNEL Serge, DIDON N.; LEM; France
CASTELLON J., MALRIEU S.; Am2e; France
Space charge measurements and ageing evaluation in stressed cables
MONTANARI Gian Carlo; DIE-LIMAT, University of Bologna; Italy
DE ROBERTIS G., PALMIERI F.; TechImp Srl; Bologna, Italy
PEREGO G., ALBERTINI M., FRANCHI BONONI S.; Pirelli Cavi Energia SpA; Italy
Study of AC electrical and thermal ageing of XLPE polyethylene by space charge measurements
AGNEL S., TOUREILLE A.; LEM Montpellier; France
PLATBROOD G.; Laborelec; Linkebeek, Belgium
The influence of temperature on electrical conduction and space charge in LDPE
LAU W.S., CHEN G.; University of Southampton; UK
The effect of voltage reversal and elevated temperature on space charge
FU M., CHEN G.; University of Southampton; UK
Study of the effects of the temperature modulation on the lifetime of HV XLPE cables
PLATBROOD G.; Laborelec; Linkebeek, Belgium
JANAH H.; Nexans; France
CLOET E.; ELIA; Belgium
BECKER J.; Nexans; France
Additives for the suppression of electrical treeing in polyethylene
LEEK, C., LE POIDEVIN G. J.; EA Technology; United Kingdom
TAIT P.J.T.; University of Manchester Institute of Science & Technology; United Kingdom
Electrical aging and breakdown of crosslinked polyethylene cables
CRINE Jean Pierre; Consultant; Canada
ZENGER Walter; EPRI; USA
Preventive diagnostic testing of high and medium voltage cables – Progress report
WEISSMUELLER G.; Technische Werke Ludwigshafen AG; Germany
ZUEHLKE L.; AVISO Netzdienste GmbH; Germany
Electrical tests of overvoltage protection devices of H.V. cables with water penetration monitoring
GOEHLICH L., SCHAPER S., KALKNER W.; Technical University Berlin; Germany
DONAZZI F., GASPARI R.; Pirelli Cables & Systems; Italy
JAHNK V.; Lancier Monitoring GmbH; France
Evaluation and modelling of thermo-electric ageing of XLPE insulated power cables: the ARTEMIS outcome
LAURENT C.; Laboratoire de Génie Electrique, Université P. Sabatier; France
CAMPUS A.; Borealis; Sweden
Accelerated long term evaluation of MV-XLPE cables
BENJAMINSEN J.T., FAREMO H.; Sintef Energy; Research Norway
LARSEN P.B., A. RYEN, WOLDEN A.; Nexans Norway AS; Norway
Assessment of cable performance as measured by a variety of accelerated ageing tests
BOSTROM J.O., MARSDEN J.O.; Borealis Compounds LCC; USA
HAMPTON N., NILSSON U.H.; Borealis AB; Sweden
A new test method to evaluate the water treeing resistance of polymers for cable insulation
FILIPPINI C.; LEMD CNRS; France
RADU I.; LEMD; France
NOTINGHER P.; Politehnica University; Bucharest, Romania
CAMPUS A.; Borealis Polymers NV; Belgium
Comparative evaluation by laboratory aging of 15 kV TR-XLPE & EP cables
KATZ C., FRYSZCZYN B.; CABLE TECHNOLOGY LABS; New Brunswick, NJ, USA
KEEFE R.; EPRI; USA
WALKER M.; Center Point Energy; USA
Evaluation of tree retardant XLPE(TR-XLPE) and EPR insulated 35 kV cables after 17 years of field service
MENDELSOHN A., PERSON T.J.; The Dow Chemical Company; USA
SHATTUCK G.B.; Alabama Power; USA
HARTLEIN R.; Georgia Tech Neetrac; USA
Investigation of electrochemical degradation in a service-aged, cable-cure restorated PE-insulated M.V. cables
BRÜGGEMANN M., KALKNER W.; Technische Universität Berlin; Germany
Novel polymeric insulating compounds for HVDC applications
MENDELSOHN A., JOW J.; The Dow Chemical Company; USA
Material solutions for extruded HVDC cables
NILSSON U.H., CAMPUS A., HAMPTON R.N.; Borealis AB; Sweden
BERGKVIST M., FARKAS A., JEROENSE M.; ABB Power Technology AB; Sweden
CARTENSEN P., JONSSON J., ZEBOUCHI N.; ABB Group Services Center AB; Sweden
Materials for HVDC extruded cables
JANAH H., MATALLANA J., BRAME J.F., MIREBEAU Pierre; Nexans; France
OUREN S.; Nexans; Norway
Effect of ageing on volume resistivity of different kinds of polyethylene cable insulation
RAKOWSKA Alexandra; Poznan University of Technology; Poland
HAJDROWSKI K.; Grupa Energetyczna ENEA S.A.; Poland
Application of PPLP to DC MI cables
MITANI M., KATAKAI S., HIROTA H., MURATA Y.; J-Power Systems Corp.; Japan
HATA R.; Sumitomo Electric Industries Ltd; Japan
Test of polymers for high voltage DC cables
RASMUSSEN C.N.; NKT Research A/S; Denmark
HOLBOELL J.T., HENRIKSEN M.; Technical University of Denmark; Denmark
Acetylene black or other conductive carbon blacks in HV cable compounds. A historical fact or a technological requirement ?
PROBST N., GRIVEI E., VAN BELLINGEN C.; Erachem Comilog SA; Belgium
Study on surface smoothness of extruded polyolefin compound contained high content of filler
XIUFENG L., XIAOGANG S., YONGHUA Z., ZHANGJIN.; Shangdong Luneng Taishan Cable Co. Ltd.; China
DARONG X.; Xi’an Jiaotong University; China
Application of fifth-generation jacketing technology for improved performance
DAMMERT R.C.; Borealis AB; Sweden
KIRCHNER M., PHILIPPCZYK C.; NKT Cables; Germany
Influence of the grain size on electrical and mechanical properties of non-linear materials
BAYON L., KOELBLIN C.; Nexans Research Center; France
Strippable shields with improved thermal stability and faster cable extrusion rates
PANG K.P., PERSON T.J.; The Dow Chemical Company; USA
DE VOS S.V.N.; Dow Europe GmbH; Switzerland
Material identity card methodology
KUNTZ M.; EDF R&D; France
GARRIGUES S.; RTE; France
Use of numerical simulation to develop a new semiconductive layer for HV cables
THIZON E., POISSON B., ARGAUT P; SAGEM; France
Partial discharge measurements on service aged medium voltage cables at different frequencies
VOIGT G.; University of Applied Sciences; Germany
MOHAUPT Peter; BAUR Prüf und Messtechnik; Austria
An investigation on the applicability of the hybrid sensor for detecting high frequency partial discharge
KIM J.H., KOO J. Y.; Han Yang University; Korea
KIM J.T.; DaeJin University; Korea
Sensitive PD detection on drained paper insulated cables
KUMM T., HEINRICH R., RETHMEIER K., JACOBSEN P., KALKNER W.; TechnicalUniversity Berlin; Germany
ZINBURG E.; GEW Rheinenergie AG; Germany
Analysis of PD source locations in mixed insulated cable circuits
WESTER F.J., GROOT E.R.S.; NUON InfraCore; The Netherlands
GULSKI Edward, QUAK B., SMIT J.J.; Delft University of Technology; Delft, The Netherlands
New designs for MV accessories: cold-shrinkable transition joints and evolution of separable cable connectors
CHATTERJEE Shotu, DE RIDDER E., CARDINAELS J.; Euromold Nexans; Belgium
Tailor-made medium voltage cables
EFRAIMSSON L., JOHNSEN U; Ericsson Network Technologies; Energy, Sweden
Design of single core cable installations exposed to short-circuit stresses
INSTANES A.; NDLO/SEA; Norway
ANDREASSEN R.; Oglaend System; Norway
KULBOTTEN H., LERVIK J.K.; SINTEF Energy Research; Norway
Determination of cable dynamic rating from distributed temperature sensing and hotspot temperature analysis
SU Qi, LI Hong-jie, TAN Kee Choon; Singapore PowerGrid; Singapore
Monitoring and dynamic rating of 120 kV XLPE insulated cable circuits at Hydro-Quebec
LEDUC J., BEAUCHEMIN R., CHAABAN M., CHOQUETTE M.; Hydro Québec (IREQ); Canada
Real time ampacity estimation system for 345 kV transmission cable installed on tunnel
LEE S.K., NAM S.H., HONG J.Y., PARK W.K.; LG Cable; Korea
YOUN H.H.; Korea Electric Power Corporation (KEPCO); Korea
Current rating of cables installed in tunnels
DORISON Eric, DE KEPPER B.; EDF R&D; France
PROTAT F., GURKAHRAMAN A., MASURE L.; SUPELEC; Gif sur Yvette, France
On-site follow up of the characteristics of controlled backfill, using the TDR moisture-measurement method
GILLE A.; BEL Engineering; Belgium
GEERTS G.; ELIA; Belgium
XANTHOULIS D., FONDER N.; Agricultural University of Gembloux; Belgium
MELLA J.-P.; Nexans Benelux; Belgium
Early detection of electrical tree through advanced PD measurement inference techniques
CAVALLINI A., CONTI M., MONTANARI G.C.; DIE, University of Bologna; Italy
PULETTI F.; TechImp; Italy
CONTIN A.; DEEI; University of Trieste, Italy
GUASTAVINO F.; DE; University of Genova, Italy
OMBELLO F.; Pirelli Cavi Energia SpA; Italy
Detection of partial discharges in HV terminations using a capacitive sensor
HVIDSTEN S., LUNDGAARD L.; SINTEF Energy Research; Norway
Modification of cable replacement criterion of isothermal relaxation current measurement system
KIM J.Y., SONG. I.K., HAN M.G.; Korea Electric Power Institute (KEPRI); Korea
YI Dong Young; Uiduk University; Korea
Applications to cable diagnosis of new methodology for partial discharge inference
CAVALLINI A., FABIANI D., MONTANARI G.C.; DIE-LIMAT, University of Bologna; Italy
OMBELLO F., FRANCHI BONONI F.; Pirelli Cavi e Sistemi SpA; Italy
Change with time in PD characteristics of a void in the semicon/polyethylene interface
KIM C.S., MIZUTANI T.; Nagoya University; Japan
KOBAYASHI S., MORIMOTO N., TSUJI S., SAITOU H.; Chubu Electric Power Co.; Nagoya, Japan
Aspects and implications of on-line PD detection and localization of MV cable systems
STEENNIS Evert Frederik; Kema High Voltage Laboratory; The Netherlands
VAN DER WIELEN.P.C.J.M., VEEN J. WOUTERS P.A.A.F; Eindhoven University of Technology; The Netherlands
Inductive directional couplers as new sensors for PD detection and localization on high voltage XLPE cable accessories
HEINRICH R.; Schaffner EMC-Systems GmbH; Germany
RETHMEIER K., KALKNER W.; Technical University Berlin; Germany
Sensitive PD detection on high voltage XLPE cable lines using field coupling sensors
HEINRICH R.; Schaffner EMC-Systems GmbH; Germany
RETHMEIER K., KALKNER W.; Technical University Berlin; Germany
PLATH Ronald; IPH, High Voltage Lab.; Germany
WEISSENBERG Werner; Brugg Kabel AG;
The analysis of the partial discharge pattern to the artificial defects introduced at the interface in an XLPE cable joint using laboratory model
LEE J.S., KIM J.T.; LG Cable. Ltd.; Korea
KOO J.Y.; Hanyang University; Korea
KIM J.T.; Daejin Univ.; Korea
Application of damped AC voltages for PD diagnosis of distribution power cables
WESTER F.J.; NUNON InfraCore; The Netherlands
GULSKI Edward; Delft University of Technology; Delft, The Netherlands
SCHIKARSKI P.; Haefely Test AF; Switzerland
SEITZ Paul P.; Seitz Instruments AG; Switzerland
Optimised cable end termination systems for laboratory tests on MV, HV and EHV
SCHIERIG S., PIETSCH, KUBAT M.; Highvolt Prüftechnik Dresden GmbH; Germany
Microspectral analysis in UV-vis range as a tool for power cable insulation diagnosis
SHUVALOV Mikhail, OVSIENKO Vladimir, KORSAKOVA M.; All-Russian Cable R&D Institute; Russia
Influence of electrochemical effects on vented tree initiation in accelerated tests
BRÜGGEMANN M., KALKNER W.; Technische Universität Berlin; Germany
BROMAN C., SMEDBERG A.; Borealis AB; Sweden
Actual application of on-site diagnostic method for water treed XLPE cable by harmonics in AC loss current
TANAKA A., TOYA A., TSUJIMOTO T., NAKADE M.; Tokyo Electric Power Company; Japan
YAGI Y., ADACHI K.; The Furukawa Electric Co. Ltd.; Japan
TANAKA H.; VISCAS Corporation; Japan
Condition assessment of triple extruded MV XLPE cables
BENJAMINSEN J.T., HVIDSTEN S.; SINTEF Energy Research; Norway
On-site TSM measurements on HV cable loops as part of the Artemis project
CASTELLON J., MALRIEU S.; Am2e; France
NOTINGHER P. jr., TOUREILLE Alain; LEM; France
BECKER J.; Nexans; Belgium
DEJEAN Pierre-Marcel; Câbles Pirelli; France
JANAH H., MATALLANA J.; Nexans; France
VERITE J.C.; EDF R&D; France
Diagnostic method for water tree aging XLPE cable with residual charge measurement
TOYA A., TANAKA A.; Tokyo Electric Power Company; Japan
OOTAKA I.; EXSYM Corporation; Japan
SAKAMOTO T.; Mitsubishi Cable Industries Ltd.; Japan
The improved residual-charge measurement to diagnose the water-tree deteriorated power cable
KON H.; Fujikura Ltd; Japan
MIYAJIMA K., UCHIDA K.; Chubu Electric Co.; Japan
WATANABE K.; VISCAS Corporation; Japan
The Raman spectroscopy analysis of electrically aged polyethylene
CHEN G., VAUGHAN A.S.; University of Southampton; UK
LIU X.Z.; Xian Jiaotong University; China
Diagnostic of field aged cables and accessories by time-domain dielectric spectroscopy (TDDS)
AMYOT N., FOURNIER D., DRAPEAU J.F.; IREQ; Varennes Québec, Canada
DAVID E.; Ecole de Technologie Supérieure; Québec, Canada
An analysis of the water treeing resistance of polymer compounds for cable insulation using the two needles method
TEISSEDRE G., FILIPPINI J.C.; LEMD; CNRS, France
NYLANDER P.; Borealis AB; Sweden
CAMPUS A.; Borealis polymers; Belgium
Comparison of different analytical test methods to monitor crosslinking by-products in XLPE insulated cables
SMEDBERG Annika, BOSTRÖM Jan-Ove; BOREALIS AB; Stenungsund, Sweden
WALD Detlef, PETERS Rudi; BOREALIS Polymers NV; Mechelen, Belgium
Breakdown caused by abrupt DC-Voltage grounding of XLPE cable insulation
IIDSTAD Erling, MAUSETH Frank; Norwegian University of Sc.and Tech. (NTNU); Trondheim, Norway
SELSJORD Mildrid, HEGERBERG Rolf; SINTEF Energy Research; Trondheim, Norway
SANDEN Bjørn; NEXANS Norway AS; Oslo, Norway
JEROENSE Marc; ABB Power Systems; Karlskrona, Sweden
LARSEN Jan Erik; Stattnett SF; Oslo, Norway
New approach to measure conductor temperature during type test
PULTRUM Edwin, SLOOT Wouter, VERHOEVEN S.A.M.; KEMA; Arnhem, The Netherlands
After-installation testing of HV/EHV extruded cable systems – procedures and experiences
HERRMANN Ulrich, KLUGE Andreas, PLATH Ronald; IPH; Berlin, Germany
HV AC testing of super-long cables
SCHIERIG Stefan, COORS Peter; TU Dresden; Dresden, Germany
HAUSCHILD Wofgang; IEC, CIGRE, TU Dresden; Germany
Type testing of a 13.2 kV, 69 MVA TRIAX HTS cable
WILLEN Dag, TRAEHOLT Chresten, THIDEMANN Carsten; nkt cables; Brondby, Denmark
JINDSAY David T, RODEN Mark, TOLBERT Jerry; Southwire Company; USA
Development of 400 kV XLPE cable and accessories
KUWAKI Akihisa, HAYASHI Katsuyuki; XSYM Corp.; Saitama, Japan
KATO Kenji; EXSYM Corp,, Mito; Aichi, Japan
IMAI Noriaki; EXSYM Corp, Sagamihara; Kanagawa, Japan
400 kV XLPE insulated cable systems with dry plug-in outdoor terminations
KAUMANNS Johannes, SCHRÖDER Gero, LEHNHÄUSER Jürgen, STROOT Volker, WEINLEIN Andreas; Südkabel; Mannheim, Germany
Development of one piece type joint (self pressurized joint) for 400 kV XLPE cable
FUDAMOTO Koji, WATANABE Yoichi, KISHI Koji, UOZUMI Tsuyoshi, TERAYAMA Atsushi; J-Power Systems Corp.; Osaka, Japan
French experience in aluminium laminated screens
LESUR Frédéric; EDF R&D; Moret-sur-Loing, France
ARGAUT Pierre; SILEC CABLE; Montereau, France
BENARD Laurent; PRYSMIAN; Paron, France
MIREBEAU Pierre; NEXANS France; Calais, France
Development of the high voltage extruded cables: Italian experience
FARA Antonio; ENEL,; Rome, Italy
ZACCONE Ernesto; PRYSMIAN Cables & Systems; Milano, Italy
400 kV 2500mm² XLPE cable system prequalification and type test for Middle East environment
MATALLANA Jérôme, GARHUNGU François, DUVIVIER Martine, DUBOIS David, MIREBEAU Pierre; NEXANS France; Calais, France
Large projects of EHV underground cable systems
ARGAUT Pierre; SILEC CABLE; Montereau, France
BJORLOW-LARSEN Kjell; NEXANS Norway AS; Oslo, Norway
ZACCONE Ernesto; PRYSMIAN Cables & Systems; Milano, Italy
GUSTAFSSON Anders; ABB; Sweden
SHELL Fabian; Brugg Kabel; Germany
WACHT Wolker; NKT Cables; Germany
The St. John's Wood - Elstree experience: testing a 20 km long 400 kV XLPE-insulated cable system after installation
SUTTON Simon; National Grid; Warwick, UK
PLATH Ronald; IPH, High Voltage Lab.; Berlin, Germany
SCHRÖDER Gero; Südkabel; Mannheim, Germany
New 345 kV underground extruded cable system project in Connecticut
ARGAUT Pierre, LUTON Marie-Hélène; SILEC CABLE; Montereau, France
LANNING John; New River Electrical Corp; Cloverdale, USA
MOSIER Rachel; Power Delivery Consultants; Ballston Lake, NY, USA
TIRINZONI Peter; Northeast Utilities; Hartford, USA
The 33 km long 87/150 (170) kV Koksijde-Slijkens link
LIEMANS Didier, LEROY Yves; NEXANS Benelux; Charleroi, Belgium
GAHUNGU François; NEXANS France; Calais, France
GILLE Alain; BEL Engineering; Belgium
MAMPAEY Bart; Elia; Belgium
Undergrounding and reorganization of the electrical system of the city of Madrid
ORELLA Josu, BARRIOCANAL Mikel, ALONSO Roberto Cabero; Iberdrola Ingeniería y Construcción; Erandio, Spain
HV power cables installed in multi-purpose tunnels, a challengeable option!
BOONE Wim, DE WILD Frank H.; KEMA Consulting; Arnhem, The Netherlands
Superconducting cables - status and applications
SAUGRAIN Jean-Maxime; NEXANS France; Clichy, France
SCHMIDT Frank; NEXANS GmbH&Co.KG; Hannover, Germany
MIREBEAU Pierre; NEXANS France; Calais, France
Installation and commissioning of TRIAX HTS cable
JINDSAY David T., RODEN Mark, DENMON Randy; Southwire Company; Carrollton, USA
WILLEN Dag; nkt cables; Denmark
MEHRABAN Ben,KERI Albert; American Electric Power; USA
Installing a long-distance HTS cable
Alex Geschiere, Erika Piga; Nuon; Duiven, The Netherlands
WILLEN Dag; nkt cables; Brondby, Denmark
BARENDREGT Peter; nkt cables; Köln, Germany
ALBAUGH Kevin; Praxair; Danbury, USA
Development and demonstration of a long length transmission voltage cold dielectric superconducting cable to operate in the Long Island Power Authority grid
SCHMIDT Frank; NEXANS GmbH&Co.KG; Hannover, Germany
MAGUIRE James; American Superconductor; Westborough, USA
BRATT Shawn; AIR LIQUIDE DTA; Sassenage, France
WELSH Tom; Long Island Power Authority; Hicksville, USA
LALLOUET Nicolas; NEXANS France; Calais, France
Potential of multilayer coating for gas insulated dielectric withstand improvement
HAIROUR Mounir, BESSEDE Jean-Luc; AREVA T&D; Villeurbanne, France
MIKES Endre; AREVA T&D AG;
TOUREILLE Alain, AGNEL Serge, NOTINGHER Petru, CASTELLON Jerôme;; IES-GEM UM2; France
Gas insulated transmission lines – underground power transmission achieving a maximum of operational safety and reliability
KUNZE Dirk, PÖHLER Stephan, ALTER Joachim; SIEMENS AG; Erlangen, Germany
BINDER Erich, TÜRK Jürgen; VERBUND Austrian Hydro Power; Salzburg, Austria
Permanent on-line monitoring of MV power cables based on partial discharge detection and localisation - an update
STEENNIS Fred, Van DER WIELEN Peter, KAPTEIN Bartjan; KEMA-TDT; Arnhem, The Netherlands
HARMSEN Denny; CONTINUON; The Netherlands
KRUITHOF Marko; ENECO; The Netherlands
POSTMA André; ESSENT; The Netherlands
On-site VHF partial discharge detection on power cable accessories
MEIJER Sander, JONGEN Rogier A., SMIT Johan J.; Delft University of Technology; Delft, The Netherlands
SEITZ Paul P.; Seitz Instruments AG; Niederrohrdorf, Switzerland
HERMANS Theo J.W.H., LAMBALLAIS Lawrence; PRYSMIAN C&S; Delft, The Netherlands
Continuous on-line monitoring of PDS in HV cables
ZHANG Hao, PHUNG Toan, LIU Zhao, BLACKBURN Trevor; University of New South Wales; Sydney, Australia
Partial discharge detection in power cables: practical limits as a function of cable length
CAVALLINI Andrea, MONTANARI Gian Carlo; University of Bologna; Italy
SUBRAMANIAM Chandrasekar; DEEE Sona College of Technology,; Tamilnadu, India
New approach for high voltage cable on-site testing
BERGMANN Volker, KALKNER Wilfried; Technische Universitaet Berlin; Germany
MOHAUPT Peter; BAUR Prüf und Messtechnik; Sulz, Austria
US experience on condition assessment of various types of taped cable systems by dissolved gas analysis based on a novel sampling and analysis technique
SINGH Nirmal, SINGH Sandeep K., REYES Rommy R., MOREL Oscar E.; Detroit Edison Company; Detroit, USA
ZENGER Walter; Pacific Gas & Electric; California, USA
Remarkable tan delta suppression of oil filled cable insulation with extremely degraded tan delta oil
TAKAHASHI Tohru, NAKAJIMA Takenori; VISCAS Corporation; Ichihara, Japan
NAKADE Masahiko, IDE Kenichi; Tokyo Electric Power Company; Yokohama, Japan
Diagnostic for paper cable condition assessment
ESPILIT Thierry, ZORZI Fabrice, REGAUDIE Vanessa, GAUDIN Christophe; EDF R&D; Moret-sur-Loing, France
TAMBRUN Roger; EDF DRE; Paris, France
Application of optical fiber current sensors to underground cables
NASUKAWA Shinsuke, KONDO Reishi, KUROSAWA Kiyoshi; Tokyo Electric Power CO.; Tokyo, Japan
YAMAGUCHI Tatsushi; Toko Electric Corporation; Japan
AMANO Kazuo; Fujikura Ltd; Tokyo, Japan
YAMADA Toshiharu; Takaoka Electric MFG. Co; Tokyo, Japan
Thermal transient analysis of underground cables
DESMET Jan, PUTMAN Dries, VANALME Greet; Hogeschool West-Vlaanderen; Kortrijk, Belgium
BELMANS Ronnie; K.U.Leuven; Belgium
CLOET Eric; ELIA,; Brussel, Belgium
FACTS for optimum utilisation of cable networks in power systems
GRÜNBAUM Rolf; ABB Power Technologies AB; Vasteras, Sweden
KARLSTRAND Johan; ABB Power Systems; Karlskrona, Sweden
Outsourcing preventive maintenance on underground power transmission cables
ALSHIBANI Salem M.; Cable Maintenance Section Head, Ministry of Energy; Yarmouk, Kuwait
SHARAF Ahmad; Senior Consulting Cable Engineer, Ministry of Energy; Yarmouk, Kuwait
Failure prediction in 50 kV mass-insulated power cable systems
JONGEN Rogier A., MORSHUIS Peter H. F., SMIT Johan J.; Delft University of Technology; Delft, The Netherlands
JANSSEN Anton L.J.; Continuon Assetmanagement; Arnhem, The Netherlands
GULSKI Edward; Ksandr; Delft, The Netherlands
Fire hazard of MV / HV cables installed in tunnels
PHILIPPCZYK Christian; NKT Cables GmbH; Köln, Germany
VENO-POULSEN Keld; NKT Cables A/S; Asneas, Denmark
JOURNEAUX Terry, GRACIAS Doug; PRYSMIAN Cables & Systems; Eastleigh, United Kingdom
LOYENS Wendy; BOREALIS AB; Stenungsund, Sweden
ROBINSON James; BOREALIS Polymers NV; Mechelen, Belgium
Dynamic rating systems in general and in a hybrid 150 kV transmission system
DE WILD Frank H., BOONE Wim; KEMA Consulting; Arnhem, The Netherlands
Van DER GEEST Hans; CONTINUON; The Netherlands
SMIT Jacco; Nuon Tecno; Alkmaar, The Netherlands
Sensitivity assessment for partial discharge measurements on solid dielectric transmission cables
SEDDING Howard, FENGER Mark; Kinectrics Inc.; Toronto, Canada
On-line location of partial discharges in an electrical accessory of an underground power distribution network
LEONARD François, CANTIN Bruno; IREQ; Varennes Québec, Canada
FOURNIER Daniel; Hydro-Québec V-P Distribution; Montreal, Canada
UHF-PD-monitoring and on-site-commissioning-test of 400 kV XLPE-insulated cable circuits at Jebel Ali / Dubai
WEISSENBERG Werner, WUNDERLIN Tony, SEKULA Oldrich; Brugg Kabel AG; Switzerland
STREHL Thomas, ELZE Heindrik, MARKALOUS Sacha; LEMKE DIAGNOSTICS; Germany
Experience with PD measurements and commissioning tests
PULTRUM Edwin, KEISER Hans-Erik; KEMA; Arnhem, The Netherlands
Practical issues regarding the use of dielectric measurements to diagnose the service health of MV cables
HERNANDEZ Jean C., HAMPTON Nigel, HARLEY Ronald, HARTLEIN Richard; NEETRAC, Georgia Institute; Atlanta, USA
Evolution of space charge and internal electric field distributions in HVDC cable under long term testing
MATALLANA Jérôme, JANAH Hakim, MIREBEAU Pierre; NEXANS France,; Calais, France
SANDEN Bjørn; NEXANS Norway AS; Oslo, Norway
CASTELLON Jérôme, AGNEL Serge, NOTINGHER Petru jr, TOUREILLE Alain; LEM, Université de Montpellier; France
Making remaining life predictions for power cables using reliability analyses
JEYAPALAN Jey K.; Dr Jeyapalan & Associates; New Milford, CT, USA
Oil replacement by water in obsolete oil-filled power cables
DARDEL Boris, MATTMANN John-Peter, JAQUENOD Laurent, VAN RYSSELBERGHE Laurent, GEHRET Sébastien, KRÄHENBÜHL Francis; NEXANS Switzerland; Cortaillod, Switzerland
Environmental impacts in rural area of a HV underground link
GOURIT Laurent, SERRES Etienne, CHEVALIER Peggy; RTE, National Centre for Grid Expertise; Paris, France
Passive loops technique for electromagnetic fields mitigation: applications and theoretical considerations.
MAIOLI Paolo, ZACCONE Ernesto; PRYSMIAN Cables & Systems; Milano, Italy
Use of an Ecoconception Software to design a HV Cable Connection
MIREBEAU Pierre, DUVIVIER Martine; NEXANS France; Calais, France
BENARD Laurent, LEBOURDON François;PRYSMIAN; Paron, France
POILLEAUX Francis, POISSON Bernard; SILEC CABLE; Montereau, France
Ecoconception, recycling and life cycle analysis in cable industry
BARBEAU Sophie, GOUDEAU Jacques; NEXANS Research Center; Lyon, France
DUPONT Isabelle; RIPS; Calais, France
DAMILO Serge; Nexans Mehun; France
Challenges of the second submarine interconnection between Spain and Morocco
GRANADINO Ramon, PRIETO Juan, DENCHE Gregorio; Red Electrica de España; Madrid, Spain
MANSOURI Fatima; Office National de L'Electricité, Casablanca (ONE); Morocco
STENSETH Knut; NEXANS Norway AS; Oslo, Norway
COMELLINI Roberto; PRYSMIAN Cables & Systems; Milano, Italy
Electrical and thermal design of umbilical cable
SHACKLETON Derek; Oceaneering Multiflex; Rosyth, UK
ABIB Luciana, BALENA Rosianita; Marine Production Systems do Brasil; Rio de Janeiro, Brazil
Qualification, supply and installation of the world's first 420 kV XLPE submarine cable system in Norway
EVENSET Gunnar, KNUTSEN Bjørn; NEXANS Norway AS; Oslo, Norway
LARSEN Jan Erik, FAUDSTAD Kirsten; Stattnett SF; Oslo, Norway
Advances in chemical rejuvenation of submarine cables
BERTINI Glen J.; Novinium Inc.; Kent, USA
Subsea connections to high capacity offshore windfarms: issues to consider
SVOMA Roman, DICKINSON Mark, BROWN Craig; PowerSure Technology, Bexleyheath; London, UK
Application of temperature sensing and dynamic strain monitoring to subsea cable technology
KLUTH Richard, SINGH Kuljit; Sensornet, Elstree; Hertfordshire, UK
SVOMA Roman; PowerSure Technology, Bexleyheath; London, UK
Challenges and opportunities when installing HV cable in Australia and Sri Lanka
RAHMAN Naveed, BARBER Ken; Olex Australia; Tottenham, Australia
Aluminium conductors in anti-robbery cables
ROSA Luiz Henrique, DE PAULA João Alves, UEDA Sidnei; NEXANS Brasil; São Paulo, Brazil
Design of a 45 circuit duct bank
COATES Mark; ERA Technology Ltd; Leatherhead, Surrey, UK
O'SULLIVAN Liam G.; EDF Energy Networks; Bexleyheath, Kent, UK
Barrier optimization algorithm applied to calculation of optimal loading of dissimilar cables in one trench
MOUTASSAM Wael; University of Toronto; Canada
ANDERS George J.; Kinectrics Inc.; Toronto, Canada
Investigation of the aging characteristics of CST termination made of silicone rubber at contamination area
NAKAMURA Tatsuya, KOZASA Yoshihide, SATO Akiyoshi, KONDOH Taikichi; Chubu Electric Power Co.; Nagoya, Japan
Evaluation of a replacement strategy of a medium voltage cable joint based on statistical failure analysis
JONGEN Rogier A., MORSHUIS Peter H.F., SMIT Johan J.; Delft University ofTechnology; Delft, The Netherlands
JANSSEN Anton; CONTINUON Assetmanagement; Arnhem, The Netherlands
GULSKI Edward; Ksandr; Delft, The Netherlands
Emergency conditions applied to triplex medium-voltage XLPE cables having flat strap neutrals
PELISSOU Serge; IREQ; Varennes Québec, Canada
CÔTE Jacques, ST-ANTOINE Serge, DALLAIRE Julien; Réseau de Distribution, Hydro-Québec; Montréal, Canada
A new specification to check cable sheath resistance to termites
BRUMENT Yves, LESUR Frédéric; EDF R&D; Moret-sur-Loing, France
PAULMIER Ivan; Centre Technique du Bois et de l'Ameublement; France
New high performance, environmentally friendly MV power cable insulations
EASTER Mark; General Cable; Indianapolis, USA
CASALS Elisenda; General Cable; Manlleu, Spain
AZPIAZU Luciano, MAIZ Gonzalo; Iberdrola Distribucion Elactrica; Bilbao, Spain
New concept in cables and accessories for low voltage underground distribution in Spain
CALVERAS Daniel; General Cable; Spain
AZPIAZU Luciano, MAIZ Gonzalo; Iberdrola, Bilbao; Spain
RIERA Joaquim; Niled; Manresa, Spain
Corrosion kinetics of LV cable galvanised steel screen and solid aluminium neutral
BRUMENT Yves; EDF R&D; Moret-sur-Loing, France
GIFFARD Philippe; Draka Paricable France; France
BEUCHER Eric; CRITT Haute Normandie; France
A new customized pulling-cable software
TARNOWSLI Janislaw, IORDANESCU Mircea, VALIQUETTE Denis, RATEL Gilles; IREQ; Varennes Québec, Canada
BERGERON François, TRINH Minh; Hydro-Québec; Canada
Service experiences for MV cable network – optimistic or pessimistic state of the art?
RAKOWSKA Aleksandra; Poznan University of Technology; Poznan, Poland
Harmonising MV cables: Results of the European project EUROMVCABLE
DAVID Jean-Marie, REGAUDIE Vanessa, LESUR Frédéric; EDF R&D; Moret-sur-Loing, France
FARA Antonio; ENEL; Italy
SIMEON Eric; Nexans; France
BENARD Laurent; PRYSMIAN; France
DIEFENBACH Ingo; RWE; Germany
Irradiation technologies and compounds for cables cross-linking – developments for flat and heat-trace cables
ROUIF Sophie; IONISOS; Dagneux, France
2007 - B3-2
Evaluation of a Replacement Strategy of a Medium Voltage Cable Joint Based on Statistical Failure Analysis
JONGEN Rogier A., MORSHUIS Peter H.F., SMIT Johan J.; Delft University ofTechnology; Delft, The Netherlands
JANSSEN Anton L.J.; CONTINUON Assetmanagement; Arnhem, The Netherlands
GULSKI Edward; Ksandr; Delft, The Netherlands
Utilisation of ceramizing materials in fire resisting cables and accessories
WEIDER Bruno; NEXANS Schweiz AG; Breitenbach, Switzerland
Ceramifying insulation materials for fire safety cables
ALEXANDER Graeme, BARBER Kenneth, LEE Dong Churl; Olex Australia; Tottenham, Australia
MARNEY Donovan; CSIRO; Australia
Choices of flame retardant materials for cables with improved behaviour in fire
DUPHIL Dominique, POISSON Bernard, ARGAUT Pierre; SILEC CABLE; Montereau, France
BARBETA Javier, PASCUAL M. Carmen, MARTINEZ Juan D.; General Cable Sistemas; Manlleu, Spain
Use of nanofillers in high performance of MV cables under fire conditions.
GRABOLOSA Jordi, CALVERAS Daniel; General Cable Sistemas,; Manlleu, Spain
CANEROT Isabelle; SILEC CABLE; Montereau, France
Polymeric armour design of an improved protection to mechanical stresses and fluids for Oil Gas and Petrochem (OGP) applications
CINQUEMANI Paul; PRYSMIAN Cables and Systems; USA
DE RAI Luca, FRIGERIO Marco; PRYSMIAN Cables & Systems; Milano, Italy
VEGETTI Paolo; PRYSMIAN Cables & Systems Oy; Finland
Health index
DORISON Eric, LESUR Frédéric, MEURICE Dominique; EDF R&D; Moret-sur-Loing, France
ROINEL Giao; RTE; France
Evaluation of the condition and the performance of underground fluid filled HV links at Hydro-Québec
ROYER Christian, AWAD Ray; Hydro-Québec; Montreal, Canada
Upgrading and uprating of underground existing systems
LESUR Frédéric; EDF R&D; Moret-sur-Loing, France
Renewal works of underground transmission system in KEPCO
FUJIWARA Eiji, HAYASHIDA Takeshi, MATSUMURA Masao; The Kansai Electric Power Co. Inc.; Japan
Re-evaluation of 150 kV cable capacity
VAN HOUWELINGEN Dirk; ENECO-Netbeheer; Rotterdam, The Netherlands
VAN ROSSUM Jos; PRYSMIAN C&S; The Netherlands
Modern cable systems in steel pipes - new designed XLPE-insulated cables substituting paper-insulated pipe-type cables
AUE Volker, ROSEBROCK Wilfried; NEXANS GmbH&Co.KG; Hannover, Germany
Increased voltage for the HVDC light product range – a complete solution
JEROENSE Marc, BERGKVIST Mikael, GUSTAFSSON Anders; VERBUND Austrian Hydro Power; Karlskrona, Sweden
RAPP Hans, SÖRQVIST Torbjörn, SVAHN Jörgen; ABB Power Products, Alingsås; Alingsås, Sweden
Nuclear cables and lifetime simulation
MONCHY-LEROY Carole; EDF R&D; Moret-sur-Loing, France
THEROND Patrice; EDF SEPTEN; Villeurbanne, France
Time Domain Spectroscopy (TDS) as a diagnostic tool for MV XLPE underground lines
DRAPEAU Jean-François, JEAN Daniel, PARPAL Jean-Luc, POTVIN Carl, LALANCETTE Daniel, L'ÉCUYER Richard; IREQ; Varennes Québec, Canada
BERNIER Simon; Ecole de Technologie Supérieure (ETS); Canada
MAGNAN Yves; Hydro-Québec; Montmorency, Canada
Development of an innovative residual-charge measurement technique for water-tree deteriorated XLPE cable
KON Hiroyuki, TANAKA Hideo; VISCAS Corporation; Ichihara, Japan
TSUKAMOTO Toyoshi, SATO Hideaki, ONUKI Koichi; Tokyo Electric Power CO,; Tokyo, Japan
Validating cable diagnostic tests
BEGOVIC Miroslav, PERKEL Joshua; School of ECE, Georgia Institute,; USA
HAMPTON Nigel, HARTLEIN Richard; NEETRAC, Georgia Institute; Atlanta, USA
Development of extruded single core cables for deep waters
BERGKVIST Mikael, HANSSON Ola, JEROENSE Marc, SONESSON Claes; ABB Power Systems; Karlskrona, Sweden
The Norned HVDC link – cable design and performance
WORZYK Thomas, SJÖBERG Mats; ABB Power Systems; Karlskrona, Sweden
SKOG Jan-Erik; Statnett; Oslo, Norway
KOREMAN Kees; Tenne T; Arnhem, The Netherlands
Development of DC +/- 250 kV coaxially-integrated return conductor extruded cable
HIRANO Seishi, HARAGUCHI Junichi;Electric Power Development; Tokyo, Japan
MIZUNO Takehiko; VISCAS Corporation; Ichihara, Japan
NAGOYA Yoshihisa; VISCAS Corporation; Tokyo, Japan
Effect of semicon-insulation interface on space charge formation in HVDC polymeric cables
FABIANI Davide, MONTANARI Gian Carlo; DIE-LIMAT University of Bologna; Italy
DISSADO Leonard A.; Dept. of Engineering, University of Leicester; Leicester, UK
LAURENT Christian, TEYSSEDRE Gilbert; Université Paul Sabatier-Laplace; Toulouse, France
MORSHUIS Peter H. F., BODEGA Riccardo; Delft University of Technology; Delft, The Netherlands
CAMPUS Alfred, NILSSON Ulf H.; BOREALIS AB; Stenungsund, Sweden
Measurement and modelling of space charge accumulation in polymeric HVDC cable systems
BODEGA Riccardo; PRYSMIAN C&S; Delft, The Netherlands
MORSHUIS Peter H. F.; Delft University of Technology; Delft, The Netherlands
PEREGO Gabriele; PRYSMIAN Cables & Systems; Milano, Italy
The use of model cables for evaluation of DC electrical properties of polymeric cable materials
NILSSON Ulf H., CAMPUS Alfred; BOREALIS AB; Stenungsund, Sweden
MONTANARI Gian Carlo; University of Bologna; Italy
MORSHUIS Peter H. F.; Delft University of Technology; Delft, The Netherlands
The use of insulated wires Milliken conductors in high voltage power transmission underground AC lines
David Dubois, Pierre Mirebeau; NEXANS France; Calais, France
Thermal and electromagnetic modelling of power umbilicals
HENRIKSEN Thor, LERVIK Jens K.; SINTEF Energy Research; Trondheim, Norway
NORMANN Truls; Aker Kvaerner Subsea; Lysaker, Norway
Current rating of cables installed in plastic ducts
MOREAU Christophe; EDF R&D; Moret sur Loing, France
COURSET Ludovic; RTE CNER; Paris France
Verification of mechanical support for cables used on bridge structures at dilation point
ROUILLARD Vincent; Victoria University; Melbourne, Australia
PIECHOTA Roman, BARNEWALL Graeme, BARBER Ken; Olex Australia; Tottenham, Australia
Measurements of thrust load in cable systems semi-rigidly installed in duct / manhole structures
BODEGA Riccardo, GEENE Henk T. F., VAN ROSSUM Joss C. M.; PRYSMIAN C&S; Delft, The Netherlands
FRENTZAS Frank, DE ANGELIS Angelo; ComEd Chicago; Chicago, USA
KELLEY Nathan; PRYSMIAN Power Cables and Systems; USA
Sensitivity of PD inception to change of electrical design in polymeric insulated power cable systems
VAN DER WIELEN Peter, VAN SCHAIK Nico; KEMA-TDT; Arnhem, The Netherlands
TCZASZEJKO Tadeusz; Monash University; Clayton, Australia
Tools for understanding the thermo-electrical behaviour of XLPE insulation in power cables and accessories
LE ROY Séverine, BAUDOIN Fulbert, TEYSSEDRE Gilbert, LAURENT Christian BOUFAYED Fakher; Laboratoire Plasma et Conversion d'Énergie, Université Paul Sabatier; Toulouse, France
DISSADO Leonard A.; University of Leicester; UK
MONTANARI Gian Carlo; University of Bologna; Italy
Improvements in superabsorbent water blocking materials for new power cable applications
CZYPRYNA Stephen, EVERAERE Jacques; Geca Tapes b.v.; Bailleul, France
DELATTRE Michel; PGI Nordlys; Bailleul, France
Energy cable modelling under power electronic converter constraints
WEENS Yannick, IDIR Nadir, FRANCHAUD Jean-Jacques, BAUSIERE Robert; Université des Sces et Techn. de Lille (USTL-L2EP); France
Longitudinal induction voltage measurement on communication cables running parallel to overhead lines or power cables
SHARAFI Dean; Western Power Corporation; Perth, Australia
KLAPPER Ulrich; Omicron electronics, Klaus; Austria
K-factor measurement of cables for optimum reliability of distance protection and fault locators
KLAPPER Ulrich; Omicron electronics, Klaus; Austria
FICKERT Lothar; Technical University of Graz (TU Gratz); Austria
Sheath circulating current calculations and measurements of underground power cables
CHEN Xiaolin, WU Kai, CHENG Yonghong, YAN Li; State Key Lab. Of Electrical Insulation and Power Equipment (SKLEI) Xi'an Jiaotong University (XJTU); Shaanxi, China
High Performance MV Cable Semi Conducting Shields
EASTER Mark; General Cable; Indianapolis, USA
CANEROT Isabelle; SILEC CABLE; Montereau, France
Dielectric system for submarine electro hydraulic umbilical up to 35 kV
TEIXEIRA Mario Daniel Junior; MDR Consultoria; Rio de Janeiro, Brazil
ABIB Luciana; Marine Production Systems do Brasil; Rio de Janeiro, Brazil
A development of underground distribution cable for water-blocking and reducing protrusions
LEE Jae-bong, KIM Ju-yong, SONG Il-keun; Korea Electric Power Institute (KEPRI); Daejeon, South Korea
KIM Byung-sook; Korea Electric Power Corporation (KEPCO); South Korea
PORCHERAY Gilles; Tyco Electronics SIMEL; France
Development of Pre-Molded Joint for 230 kV XLPE Power Cable
KIM Hwa Jong, KIM Hyun Joo, KIM S.Y., SONG Jae Hyuk; E.HV. Acc'y R&D Center, Taihan Electric Wire Co.; Seoul, South Korea
Transition joints
COURSET Ludovic; RTE CNER; Paris France
HONDAA Pierre; EDF R&D; Moret-sur-Loing, France
Compact various transition joints for up to 154 kV power cable
NIINOBE Hiroshi; VISCAS Corporation; Ichihara, Japan
YOKOYAMA Shigekazu, TORAI Yasuo; VISCAS Corporation; Tokyo, Japan
KANEKO Satoshi; VISCAS Corporation; Hirastuka, Japan
Upgrading quality of 275 kV Y - branch pre-fabricated transition joint
Tatsuo Nakanishi, Takehiro Nozaki, Tadashi Ohimo, Masaru Watanabe, Shunichirou Ban, Shigekatsu Yamada; J-Power Systems Corp.; Osaka, Japan
Development of outdoor-sealing-end of prefabricated-composite-insulator for 66/77 kV XLPE cable
IWASAKI Kimihiro, TANAKA Atsushi, TOYA Atsushi; Tokyo Electric Power CO.; Tokyo, Japan
SATOU Hiromasa; EXSYM Corp,; Sagamihara, Kanagawa, Japan
ADACHI Kazuhisa, SEMA Nobuyuki; SWCC SHOWA Cable System Co; Kanagawa, Japan
Development of dry type out-door terminations for 66 to 110 kV XLPE cable
OONO Kouichi; VISCAS Corporation; Ichihara, Japan
KANEKO Satoshi, TAKAOKA Isao; VISCAS Corporation; Hiratsuka, Japan
Compounding of semiconductives for high voltage cables
RICHARDSON Colin G.; Buss AG; Pratteln, Switzerland
Stabilizer concepts for Silane crosslinked polyethylene cable applications
HERBST Heinz; CIBA Specialty Chemicals; Basel, Switzerland
FAGOURI Chris; CIBA Specialty Chemicals; Tarrytown, USA
Performance of modern cables in Central Europe
Detlef Wald; BOREALIS Polymers NV; Mechelen, Belgium
Annika Smedberg; BOREALIS AB; Stenungsund, Sweden
Long-life XLPE insulated power cables
HAMPTON Nigel, HARTLEIN Richard; NEETRAC, Georgia Institute; Atlanta, USA
LENNARTSSON Hakan; Borouge Pty; Hong Konk
ORTON Harry; OCEI; Vancouver, BC, Canada
RAMACHANDRAN Ram; The Dow Chemical Company; Somerset, NJ, USA
Development on recycling technology of XLPE
SEKIGUCHI Youitsu, OHKAWA Noriyuki, NOJO Hitoshi, HASHIMOTO Satoru; J-Power Systems Corp.; Tokyo, Japan
Innovative bolted connector for LV and MV with stepless shear bolts
GROSS Hervé, FRANK Erich; PFISTERER KONTAKTSYSTEME GmbH & Co. KG,; Winterbach, Germany
Surge propagation and protection of underground distribution cables
LEE Jae-bong, KIM Ju-yong, PARK Chul-bae, JUNG Yeon-ha; Korea Electric Power Institute (KEPRI); South Korea
Advances in chemical rejuvenation: extending medium voltage cable life 40 years
BERTINI Glen J., VINCENT Gary A.; Novinium Inc.; Kent, USA
Modern FEM tools – an example of cables installed in duct-banks
KARLSTRAND Johan, HENNING Gunnar;ABB Power Systems; Karlskrona, Sweden
Application results of real-time ampacity estimation system and intelligent power cable system
NAM S.H., LEE J.M., KIM K.Y.,KIM C.S., LEE S.K., JEON S.I.; LS Cable; Anyang-si, South Korea
KIM H.L., KIM Y.S., LIM H.E.; KEPCO; Seoul, South Korea
Adaptive monitoring program for dynamic thermal rating of power cables
BRAKELMANN Heinrich, HIRSCH Holger, RÖHRICH Armin, SCHEIFFARTH Hans-Peter, STAMMEN Jörg; University of Duisburg-Essen; Germany
HV cables operating in a dynamic rating regime, a beneficial option!
DE WILD Frank H., BOONE Wim; KEMA; Arnhem, The Netherlands
Development on the mortar material for cable systems in a directional drilling
NISHIYAMA Yoshinari, MASHIMA Hironori, UESAWA Makoto, SAITO Hiroshi, ISHIZONE Takeshi; Chubu Electric Power Co. Inc; Nagoya, Japan
MIZUNO Satoshi; Toenec Corp.; Japan
Sharing pipelines, tunnels, multipurpose structures, and rights of way among cables, optical cables, gas lines, sewers, heating ducts, and waterlines
JEYAPALAN Jey K.; Dr Jeyapalan & Associates; New Milford, CT, USA
Fire prevention method for 275 kV oil-filled cable joint in TEPCO
TOYA Atsushi, NASUKAWA Shinsuke; Tokyo Electric Power Company; Tokyo, Japan
Development and efficacy of sheath current reduction devices on underground power cable systems
YOON Hyung-Hee, KANG Ji-Won, MYOUNG Keun-Sik; KEPRI; South Korea
KWAK Bang-Myung; KEPCO; Japan
Multiconductor cell analysis of power cable steady state
BENATO Roberto; University of Padova; Italy
A user-friendly tool for simulating the time-dependent field distribution in PE insulation on the basis of a physical approach
LE ROY Séverine, BOUFAYED Fakher, BAUDOIN Fulbert, TEYSSEDRE Gilbert, LAURENT Christian; Laboratoire Plasma et Conversion d'Énergie, Université Paul Sabatier; Toulouse, France
Exploring the water treeing inhibition effect of antioxidants for XLPE insulation
MATEY Gabriel, LABBE Dennis; Products and Marketing Ltd; Geneva, Switzerland
Study of thermally and water tree aged polyethylene by infrared spectroscopy, absorption currents and space charge measurements
STANCU Christina, NOTINGHER Petru; Politehnica University of Bucharest; Romania
NOTINGHER P. jr, CASTELLON Jérôme, AGNEL Serge, TOUREILLE Alain; LEM, Université de Montpellier 2; France
RAKOWSKA Aleksandra, SIODLA Krzysztof; Technical University of Poznan; Poland
Water treeing at high hydrostatic pressure and temperatures
FAREMO Hallvard, HVIDSTEN Sverre, BENJAMINSEN Jan Tore; SINTEF Energy Research; Trondheim, Norway
BORNES Atle Harald; Statoil ASA; Bergen, Norway
Improved understanding of extruded MV cable performance through the modification of existing approval protocols
HAMPTON Nigel, HARTLEIN Richard; NEETRAC, Georgia Institute; Atlanta, USA
A molecular approach to the electrical aging of XLPE cables
CRINE Jean-Pierre; Technology Consultant lso with Ecole Polytechnique de Montréal; St Bruno, Canada
CRINE Jean-Pierre; Technology Consultant lso with Ecole Polytechnique de Montréal; St Bruno, Canada
Kinetic modelling of phenol stabiliser efficiency in polyethylene submitted to nuclear environments
RICHAUD Emmanuel, COLIN Xavier, AUDOUIN Ludmila, VERDU Jacques; LIM-ENSAM de Paris; France
MONCHY-LEROY Carole; EDF R&D; Moret-sur-Loing, France
A numerical method for 3D-description of scattered characteristic aging data from multistress aged XLPE-cable insulation
REUTER Mark, GOCKENBACH Ernst, BORSI Hossein; Schering Inst., Leibnitz Universität; Hannover, Germany
Understanding and optimization of long term ageing in cable industry
STUHLDREIER Thomas, FOURNIER Jérôme; NEXANS Research Center; Lyon, France
PLANES Émilie; MATEIS UMR CNRS 5510 INSA Lyon; France
Electrical and physico-chemical analysis of Belgium medium voltage cables data bank
CASTELLON Jérôme, AGNEL Serge, NOTINGHER Petru jr, TOUREILLE Alain; IES-UM2, Université de Montpellier; France
BEAUGUITTE Dimitri, PLATBROOD Gerard, TITS Yvan; Laborelec; Linkebeek, Belgium
Development of diagnostic procedures for XLPE cables with water trees
FOOTTIT Frith, LYALL Jim, OYEGOKE Bolarin, BIRTHWHISTLE David; Queensland University of Technology (QUT); Australia
Effect of cross-linking and antioxidant on the conductivity of the polyethylene
HOUABES M.; University Badji Mokhtar of Annaba; Algeria
Annealing effect on the conductivity of XLPE insulation in power cable
BELANA Juan, ÒRRIT Jordi, DIEGO José Antonio, MUDARRA Miguel; Universidad de Catalunya (ETSEIAT); Barcelona, Spain
FRUTOS Fabián, ACEDO Miguel; Universidad de Sevilla (ETSII); Spain
Effect of the dielectric strength test on dielectric properties
TAMUS Z. Á., NEMETH E. N; Budapest University of Technology; Hungary
Space charge measurements in XLPE insulated mid-voltage cable: correlation with cable performance
TAMAYO Idalberto, ÒRRIT Jordi, DIEGO José Antonio; Universidad Politècnica de Catalunya (ETSEIAT); Barcelona, Spain
Water treeing test results for different XLPE compounds obtained with needle techniques
SHUVALOV Mikhail, OVSIENKO Vladimir, OBRAZTOV Yuri; VNIIKP; Moscow, Russia
URBANCZYK Andrzej; BOREALIS; Poznan, Poland
BOSTRÖM Jan-Ove; BOREALIS AB; Stenungsund, Sweden
Crosslinking and water treeing in polyethylene insulation
CIUPRINA Florin; ELMAT lab. Politehnica University of Bucharest; Romania
FILIPPINI Jean César, TEISSEDRE Gisèle; LEMD-CNRS / UJF; Grenoble, France
CAMPUS Alfred, SMEDBERG Annika; BOREALIS AB; Stenungsund, Sweden
Initiation site analysis of vented water trees growing from the conductor screen of service and laboratory aged XLPE cable insulation
HVIDSTEN Sverre, FAREMO Hallvard, SELSJORD Mildrid; SINTEF Energy Karl; Stenungsund, Sweden
JÄGER Michael, SMEDBERG Annika, NILSSON Ulf H.; BOREALIS AB; Stenungsund, Sweden
KVANDE Stine; NTNU, Dept. of Physics; Trondheim, Norway
KALKNER Wilfried; Technische Universität Berlin; Germany
Insulation diagnosis of high voltage power cables
GULSKI Edward, SMIT Johan J., CICHECKI Piotr; Delft University of Technology ; Delft, The Netherlands
DE VRIES Frank; Nuon Tecno, Alkmaar; The Netherlands
SEITZ Paul P., QUAK Ben; Seitz Instruments AG; Niederrohrdorf, Switzerland
PETZOLD Frank; SebaKMT; Baunach, Germany
Novel method for on-site testing and diagnosis of transmission cables up to 250 kV
SEITZ Paul P., QUAK Ben; Seitz Instruments AG; Niederrohrdorf, Switzerland
GULSKI Edward, SMIT Johan J., CICHECKI Piotr; Delft University of Technology ; Delft, The Netherlands
DE VRIES Frank; Nuon Tecno; Alkmaar, The Netherlands
PETZOLD Frank; SebaKMT; Baunach, Germany
Partial discharge diagnosis on live EHV power cable using planar UWB antenna
LWIN Kyaw-Soe, SHIN Dong-Hoon, YIM Youn-Chan, PARK Noh-Joon, PARK Dae-Hee; Wonkwang University; Iksan, South Korea
HWANG Doo-Hyun, LIM Jong-Cheon; Taihan Electric Wire; Seoul, South Korea
Leak location in oil paper cables
LANDUCCI Laurent; RTE; Courbevoie, France
LANZARONE Lucien; RTE; Vitry-sur-Seine, France
Dominique Meurice; EDF R&D; Moret-sur-Loing, France
Hydrogen elimination from a 225 kV HPOF pipe-type line
LINOIS Pierre; RTE-TENP - GIMR; Nanterre, France
BONNARDOT Gilles; RTE-TENP - GETSO; Guyancourt, France
GAZARIAN Serge; RTE-TENP; France
Cable rejuvenation; past, present and future
STAGI William, CHATTERTON Wayne; UtilX Corporation; Kent, WA, USA
Monitoring based maintenance for underground cables utilizing sensor networks
MIN Byoung-Woon, CHOI Ho-Woong, MYOUNG Hee-Chul, KIM Jung-Han; Hyundai Heavy Industries; Kyounggi, South Korea
NAM Sang-Bum; NeoTelecom; Seoul, South Korea
Condition assessment of power cable systems in the energized state
SRINIVAS N. Nagu; UtilX Corporation; Kent, WA, USA
BERNSTEIN Bruce; Bruce S. Bernstein Consulting LLC; USA
Diagnostic testing of MV accessories by Time Domain Spectroscopy (TDS)
POTVIN Carl, JEAN Daniel, LALANCETTE Daniel, PARPAL Jean-Luc, DRAPEAU Jean-François, L'ÉCUYER Richard; IREQ; Varennes Québec, Canada
BERNIER Simon; Ecole de Technologie Supérieure (ETS); Canada
Wireless sensor network based partial discharges monitoring of underground cable systems
CHOI Ho-Woong, MIN Byoung-Woon, MYOUNG Hee-Chul, LEE Byoung-Ho; Hyundai Heavy Industries; Kyounggi, South Korea
CHO Sang-Moon; NeoTelecom Co.Ltd,; Seoul, South Korea
Feasibility study on application of WIMAX technology to underground cables data acquisition
MYOUNG Hee-Chul, CHOI Ho-Woong, MIN Byoung-Woon, PARK Dong-Ho; Hyundai Heavy Industries; Kyounggi, South Korea
KIM Yong-Joo;NeoTelecom Co. Ltd,; Seoul, South Korea
Advanced solution for on-site diagnosis of distribution power cables
GULSKI Edward, SMIT Johan J.; Delft University of Technology; Delft, The Netherlands
PETZOLD Frank; SebaKMT; Baunach, Germany
SEITZ Paul P., QUAK Ben; Seitz Instruments AG; Niederrohrdorf, Switzerland
DE VRIES Frank; Nuon Tecno; Alkmaar, The Netherlands
Experiences with offline PD-diagnosis on MV cables – knowledge rules for asset decisions
PETZOLD Frank, BEIGERT Michael; SebaKMT; Baunach, Germany
GULSKI Edward; Delft University of Technology; Delft, The Netherlands
Sensitivity verification procedure of VHF PD detection systems
MEIJER Sander, LADDE Ruben C., JONGEN Rogier A., SMIT Johan J.; Delft University of Technology (TU Delft); Delft, The Netherlands
HERMANS Theo J.W.H., LAMBALLAIS Lawrence; PRYSMIAN C&S; Delft, The Netherlands
50 Hz Partial Discharge Diagnostics - Experience of N-Ergie AG. Minimizing cable failures by Reliability-Centered Maintenance of Networks
CHRISTL Hans-Jürgen; NexaTec GmbH; Germany
LINK Stefen; N-Ergie; Germany
Translation: Frank Verschraegen; IMCORP Europe BVBA; Lochristi, Belgium
UHF Partial discharge diagnosis of plug-in cable terminations
DENISSOV Denis, KÖHLER Wolfgang, TENBOHLEN Stefan; University of Stuttgart; Germany
GRUND Ruben, KLEIN Thomas; PFISTERER Kontaktsysteme GmbH; Winterbach, Germany
On-site partial discharge testing of distribution class cables using VLF and power frequency excitation
Detlev W. Gross, Markus Söller; Power Diagnostix Systems GmbH; Aachen, Germany
© Copyright Jicable